Designed for use as a recovery heater having its own storage tank. Available in
upright standard models (DEN) and lowboy models (DEL).
GLASSLINED TANK
• Thirteen sizes; 6 thru 119 gallon
capacity. Tank interior is coated with
glass specially designed by A. O. Smith
for water heater use.
CSA CERTIFIED AND ASME RATED
T&P RELIEF VALVE
SIMPLIFIED CIRCUITRY, COLOR
CODED FOR EASE OF SERVICE
ANODE ROD FOR MAXIMUM
ELEMENTS
• Zinc plated copper sheaths for longer
life. Medium watt density means lower
surface temperature to minimize scale
build-up and more surface to heat
water. Element sizes from 1.5 to 6 KW.
Maximum input 12 KW (see chart).
STANDARD VOLTAGES
• 120, 277 single phase and 208, 240
and 480V unbalanced three-phase
delta; easily converted to single-phase at
terminal block (except 208V with 5500
watt elements). Single element heaters,
single-phase only.
TERMINAL BLOCK
• Factory-installed. Just bring the service
to heater and connect to block. Terminal
block not supplied on 120V & 277 volt
models. (No junction box on DEL6-20)
CONTROLS
• Temperature control (adjustable
through a range of 130° to 170°F on
single element and 120° to 181°F on
dual element) and manual reset high
temperature cutoff per element
CORROSION PROTECTION
CABINET HAS BONDERIZED
UNDERCOAT WITH BAKED
ENAMEL FINISH
TOP INLET AND OUTLET OPENINGS
DRAIN VALVE
(EXCLUDES DEL 6-20)
UL APPROVED FIELD CONVERSION
PROGRAM
COMPLIANCE
• Meets the standby loss Requirements
of the U.S. Department of Energy and
current edition of ASHRAE/IES 90.1.
LIMITED WARRANTY OUTLINE
• If the tank should leak any time during
the first three years, under the terms of
the warranty, A. O. Smith will furnish a
replacement heater; installation, labor,
handling and local delivery extra. THIS
OUTLINE IS NOT A WARRANTY. For
complete information consult the written
warranty or A. O. Smith Water Products
Company.
Recovery capacities at 100° F rise equal: for non-simultaneous element operation = 4.1 gal. x kW of one element; for simultaneous element operation = 4.1 gal. x 2/3 kW of both elements.
For other rises multiply element kW as previously explained by 410 and divide by temperature rise. Full load current for single phase = total watts/voltage.
U. S. Gallons/Hr and Litres/Hr at Temperature Rise Indicated
SPECIFICATION
The water heaters(s) shall be Dura-Power™ Model(s) No. ______ as manufactured by A. O. SMITH or an approved equal. Heater(s) shall be rated at
_____kW, _____volts, _____-phase, 60 cycle AC, and listed by Underwriters’ Laboratories. Models shall meet the standby loss requirements of the U.S.
Department of energy and current edition of ASHRAE/IES 90.1. Tank(s) shall be _____gallon capacity. Heater(s) shall have 150 psi working pressure and
be equipped with extruded high density anode rod. All internal surfaces of the heater(s) exposed to water shall be glasslined with an alkaline borosilicate
composition that has been fused-to-steel by firing at a temperature range of 1400°F to 1600°F. Electric heating elements shall be medium watt density
with zinc plated copper sheath. Each element shall be controlled by an individually mounted thermostat and high temperature cutoff switch. The outer
jacket shall be of backed enamel finish and shall enclose the tank with foam insulation. Electrical junction box with heavy duty terminal block shall be
provided (except on 120V & 277V {no junction box on DEL-6 thru 20}). The drain valve shall be located in the front for ease of servicing. Heater tank shall
have a three year limited warranty as outlined in the written warranty. Fully illustrated instruction manual to be included.
For technical information, call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.