A. O. Smith DEL-10 User Manual

Commercial Electric
®
Water Heaters
TM
Designed for use as a recovery heater having its own storage tank. Available in upright standard models (DEN) and lowboy models (DEL).
GLASSLINED TANK
glass specially designed by A. O. Smith for water heater use.
ELEMENTS - Zinc plated copper sheaths for longer life. Medium watt density means lower surface
temperature to minimize scale build-up and more surface to heat water. Element sizes from 1.5 to 6 KW. Maximum input 12 KW (see chart on back).
STANDARD VOLTAGES - 120, 277 single phase and 208, 240 and 480V unbalanced three-phase
delta; easily converted to single-phase at terminal block (except 208V with 6000 watt elements). Single element heater, single-phase only.
TERMINAL BLOCK - Factory-installed. Just bring the service to heater and connect to block.
Terminal block not supplied on 120V & 277 volt models. (No junction box on DEL6-20)
CONTROLS - Temperature control (adjustable through arange of 110° to 170°F on single element
and 120° to 180°F on dual element) and manual reset high temperature cutoff per element (dual element models). Factory-wired for non-simultaneous operation; easily converted to simultaneous element operation (three phase models only).
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE
SIMPLIFIED CIRCUITRY, COLOR CODED FOR EASE OF SERVICE
ANODE ROD FOR MAXIMUM CORROSION PROTECTION
CABINET HAS BONDERIZED UNDERCOAT WITH BAKED ENAMEL FINISH
TOP INLET AND OUTLET OPENINGS
DRAIN VALVE (EXCLUDES DEL 6-20)
DEN/DEL
MODELS
®
®
®
UL APPROVED FIELD CONVERSION PROGRAM
models are UL listed to UL 174 and the 30 through 120 models are listed to UL 1453.
COMPLIANCE
Department of Energy and current edition of ASHRAE/IESNA 90.1.
LIMITED WARRANTY OUTLINE
three years, under the terms of the warranty, A. O. Smith will furnish a replacement heater; installation, labor, handeling and local delivery extra. THIS OUTLINE IS NOT A WARRANTY. For complete information consult the written warranty or A. O. Smith Water Products Company.
Revised August 2013
- Meets the standby loss Requirements of the U.S.
- If the tank should leak any time during the first
- The 6 through 20
Low Lead Content
Page 1 of 2
AOSCE15400
Commercial Electric
®
Water Heaters
TM
PRODUCT SPECIFICATIONS
ROUGH-IN DIMENSIONS
Models No. of Tank Capacity A B C D Dimensions Elements US Gals. Litres inches mm inches mm inches mm inches mm Lbs. Kg.
DEL-6 1 6 23 15 1/2 394 14 1/4 362 11 279 - - 35 15.9
DEL-10 1 10 38 18 1/4 464 18 457 12 1/2 318 - - 54 24.5
DEL-15 1 15 57 26 660 18 457 20 1/2 521 - - 58 26.3
DEL-20 1 20 76 22 1/4 565 21 3/4 552 15 3/8 391 - - 73 33.1 DEL-30 2 30 114 30 7/8 784 21 3/4 552 24 1/8 613 8 203 100 45.4 DEL-40 2 40 151 32 1/4 819 24 610 25 9/16 649 8 203 125 56.7 DEL-50 2 50 189 32 1/4 819 26 1/2 673 25 1/8 638 8 203 166 75.3 DEN-30 2 30 114 34 1/2 876 20 1/2 521 - - 8 203 98 44.5 DEN-40 2 40 151 45 1/8 1146 20 1/2 521 - - 8 203 113 51.3 DEN-52 2 50 189 54 7/8 1394 20 1/2 521 - - 8 203 131 59.4 DEN-66 2 66 250 60 3/4 1543 21 3/4 552 - - 8 203 176 79.8
DEN-80 2 80 303 59 3/8 1508 24 610 - - 8 203 211 95.7
DEN-120 2 119 450 62 7/16 1586 29 3/8 746 - - 8 203 326 147.9
RECOVERY CAPACITIES
Element U.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED Wattage INPUT F° (Upper/Lower)
NON-SIMULATANEOUS OPERATION /1500 GPH 17 15 11 10 8 8 7 6 6 5 5
/2000 GPH 23 20 15 14 11 10 9 8 8 7 6
/2500 GPH 28 25 19 17 14 13 11 10 9 8 8
3000/3000 GPH 34 30 23 20 17 15 14 12 11 10 10
4000/4000 GPH 45 41 30 27 23 20 18 16 15 14 13
4500/4500 GPH 51 46 34 30 25 23 20 18 17 15 14
5000/5000 GPH 56 51 38 34 28 25 23 20 19 17 16
6000/6000 GPH 68 61 45 41 34 30 27 24 23 20 19
SIMULATANEOUS OPERATION
3000/3000
4000/4000
4500/4500
5000/5000
6000/6000
Recovery capacities at 100° F rise equal: for non-simultaneous element operation = 4.1 gal. x kW of one element; for simultaneo us element operation = 4.1 gal. x 2/3 kW of both elements. For other rises multiply element kW as previously explained by 410 and divide by temperature rise. Full load current for single phase = total watts :- voltage.
KW C° 20C° 22.2C° 30C° 33.3C° 40C° 44.4C° 50C° 55.5C° 60C° 66.6C° 70C°
1.5 LPH 64 58 43 38 32 29 26 23 21 19 18
2.0 LPH 85 77 57 51 43 38 34 31 28 26 24
2.5 LPH 107 96 71 64 53 48 43 38 36 32 30
3.0 LPH 128 115 85 77 64 58 51 46 43 38 37
4.0 LPH 170 153 114 102 85 77 68 61 57 51 49
4.5 LPH 192 173 128 115 96 86 77 69 64 58 55
5.0 LPH 213 192 142 128 107 96 85 77 71 64 61
6.0 LPH 256 230 170 153 128 115 102 92 85 77 73
6 LPH 256
8 LPH 341
9 LPH 384
10 LPH 426
12 LPH 51
36F° 40F° 54F° 60F° 72F° 80F° 90F° 100F° 108F° 120F° 126F°
61 45
GPH 68
GPH 90
GPH 101
GPH 11
GPH 135
230 170 153 128 11
81 60
307 227 205 170 153 136 123 114 102 97
91 68 61 51 46 41
345 256 230 192 173 153 138 128 115 110
3
101 75 68 56 51 45 41 38 34 32 384 284 256 213 192 170 153 142 128 122 122 90 81 68 61 54 49 45
1 460 341 307 256 230 205 184 170 153
41 34 30 27 24 23 20
54 45 41 36 32 30 27 26
5 102 92 85 77 73
36 34 30
Shipping Weight.
19
29
41 39
146
SUGGESTED SPECS
The water heaters(s) shall be Dura-Power™ Model(s) No. as manufactured by A. O. SMITH or an approved equal. Heater(s) shall be rated at kW, volts, phase, 60 cycle AC, and listed by Underwriters’ Laboratories. Models shall meet the standby loss requirements of the U.S. Department of energy and current edition of ASHRAE/IESNA 90.1. Tank(s) shall be gallon capacity. Heater(s) shall have 150 psi working pressure and be equipped with extruded high density anode rod. All steel by firing at a temperature range of 1600°F. Electric heating elements shall be medium watt density with zinc plated copper sheath. Each element shall be controlled by an individually mounted thermostat and high temperature cutoff switch. The outer jacket shall be of backed enamel finish and shall enclose the tank with foam insulation. Electrical junction box with heavy duty terminal block shall be provided (except on 120V & 277V {no junction box on DEL-6 thru 20}). The drain value shall be located in the front for ease of servicing. Heater tank shall have a three year limited warranty as outlined in the written warranty. Fully illustrated instruction manual to be included.
For Technical Information and Automated Fax Service, call 800-527-1953. A. O. Smith Corporation reserves the right to make prod uct changes or improvements without prior notice.
Revised August 2013
www.hotwater.com
Page 2 of 2
AOSCE15400
Loading...