Commercial Gas Water Heaters
MODULATING BURNER ADVANCES THE
CYCLONE TO HIGHER LEVELS OF EFFICIENCY
FEATURES
The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to
provide years of dependable service and feature industry leading technology. Models are
available from 120,000 to 500,000 Btu/h and all deliver thermal efficiencies of 95% and
higher. The unique helical coil heat exchanger limits weld joints for optimal service life
while maximizing heat transfer.
Cyclone is the industry leader in high efficiency commercial water heating with over a quarter
million Cyclones sold since 1996. The current Mxi modulating models adjust firing rate to the
specific demand further increasing efficiency and money savings.
BTH-120(A)
through
BTH-500(A)
INTELLIGENT CONTROL SYSTEM WITH LCD DISPLAY
nExclusive A. O. Smith designed control system
nProvides detailed water heater status information
nPrecise temperature control adjustable from 90 to 180 degrees
nBuilt-in diagnostics
nRun history information
nCyclone water heaters are compatible with the iCOMM™ remote
monitoring system. Call 1.888.928.3702 for more information.
SUBMERGED COMBUSTION CHAMBER, WITH HELICAL HEAT EXCHANGER COIL
nPositioned in center of tank, surrounded by water to virtually eliminate radiant heat
loss from chamber
nDirect spark ignition
nSpiral heat exchanger keeps hot burner gases swirling, uses centrifugal force to maximize
efficiency of heat transfer to water in tank
nSpiral heat exchanger reduces lime scale from forming on water-side surfaces, which
maintains energy efficiency over time
POWERED ANODES STANDARD ON ALL MODELS
nProvides long-lasting tank protection in varying water conditions
nPowered anodes are non-sacrificial
nAutomatically adjusts output needed to properly protect the tank
PERMAGLAS® ULTRA COAT™ GLASS LINING
nGlass coating is applied using a liquid slush coating technique to ensure uniform coating
nHeat exchanger coil is glassed both externally and internally for optimum protection
MECHANICAL VENTING VERSATILITY
nConventional power venting or direct venting
nVents vertically or through a sidewall
nFront located exhaust and condensate connections allow for easy install and access
nVents with low cost PVC Schedule 40 intake and exhaust pipe. Approved for optional
CPVC Schedule 40, Polypropylene and AL29-4C stainless steel vent materials
nDirect-vent intake and exhaust pipe can terminate separately outside building or through
single opening, using concentric vent assembly
nCanadian installations require ULC S636 PVC/CPVC, ULC S636 Polypropylene and AL29-4C
stainless steel pipe for intake and exhaust
1.888.WATER02
Model Shown:
100 Gallon
ANSl/NSF-5
HIGH EFFICIENCY MODULATING PRE-MIX POWERED BURNER
n Down-fired pre-mix burner provides optimum efficiency and quiet operation
n Top-mounted burner position prevents condensation from affecting burner operation
Revised June 2014
Page 1 of 4
AOSCG10210
Commercial Gas Water Heaters
OTHER CYCLONE Mxi FEATURES
SPACE-SAVING DESIGN FOR INSTALLATION FLEXIBILITY
nReduced footprint, ease of service, protection from water damage in case of flooding
nEasy-to-remove top cover for convenient access to serviceable parts
n0˝ installation clearances on sides and rear, 1-1/2˝ installation clearance on top
nHandhole cleanout allows easy access to tank interior for cleaning
n0˝ clearance to combustibles, approved for installation on combustible floors
CODES AND STANDARDS
nCSA certified and ASME rated T&P relief valve
nMaximum hydrostatic working pressure: 160 PSI
nAll models are design certified by Underwriters Laboratories (UL), Inc., to ANSI Z21.10.3 - CSA 4.3 Standards
nMeets the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition ASHRAE/IESNA 90.1
nDesign-certified by Underwriters Laboratories to NSF standard 5 for 180°F (62°C) water
nComplies with SCAQMD Rule 1146.2 and other Air Quality Management Districts with similar requirements for low-NOx emissions
nASME tank construction optional on 120-500 model sizes
THREE-YEAR LIMITED TANK WARRANTY
nFor complete warranty details, consult written warranty shipped with heater, or contact A. O. Smith
(5-year tank extended warranty is optional)
OPTIONIAL KITS
nOptional Concentric Vent Kits
BTH-120 - 250 vent kit p/n 9006328005
BTH-300 - 500 vent kit p/n 9006144005
nOptional Low Profile Termination Vent Kits
3˝ Flush Mount Vent Kit p/n 9008933005
4˝ Flush Mount Vent Kit p/n 9008934005
6˝ Flush Mount Kit p/n 9008935005
nOptional Condensate Neutralization Kits
BTH-120-199 kit p/n 9007959005
BTH-250-500 kit p/n 9007960005
VENTING REQUIREMENTS
BTH-120(A) - 250(A)
NUMBER OF 90°
ELBOWS INSTALLED
One (1) 45 feet (13.7 meters) 115 feet (35.0 meters)
Two (2) 40 feet (12.2 meters) 110 feet (33.5 meters)
Three (3) 35 feet (10.7 meters) 105 feet (32.0 meters)
Four (4) 30 feet (9.1 meters) 100 feet (30.5 meters)
Five (5) N/A 95 feet (29.0 meters)
Six (6) N/A 90 feet (27.4 meters)
3 INCH PIPE 4 INCH PIPE
MAXIMUM FEET (METERS) MAXIMUM FEET (METERS)
BTH-300(A) - 500(A)
NUMBER OF 90°
ELBOWS INSTALLED
One (1) 65 feet (19.8 meters) 115 feet (35.0 meters)
Two (2) 60 feet (18.2 meters) 110 feet (33.5 meters)
Three (3) 55 feet (16.8 meters) 105 feet (32.0 meters)
Four (4) 50 feet (15.2 meters) 100 feet (30.5 meters)
Five (5) 45 feet (13.7 meters) 95 feet (29.0 meters)
Six (6) 40 feet (12.2 meters) 90 feet (27.4 meters)
4 INCH PIPE 6 INCH PIPE
MAXIMUM FEET (METERS) MAXIMUM FEET (METERS)
GAS PRESSURE REQUIREMENTS
MODEL
BTH-120(A) 0˝ W.C. (0 kPa) 0˝ W.C. (0 kPa) 4.4˝ W.C. (1.10 kPa) 8.5˝ W.C. (2.12 kPa) 14˝ W.C. (3.49 kPa) 14˝ W.C. (3.49 kPa)
BTH-150(A) 0˝ W.C. (0 kPa) 0˝ W.C. (0 kPa) 4.4 ˝ W.C. (1.10 kPa) 8.5˝ W.C. (2.12 kPa) 14˝ W.C. (3.49 kPa) 14˝ W.C. (3.49 kPa)
BTH-199(A) 0˝ W.C. (0 kPa) 0˝ W.C. (0 kPa) 4.4 ˝ W.C. (1.10 kPa) 8.5˝ W.C. (2.12 kPa) 14˝ W.C. (3.49 kPa) 14˝ W.C. (3.49 kPa)
BTH-250(A) 0˝ W.C. (0 kPa) 0˝ W.C. (0 kPa) 4.4 ˝ W.C. (1.10 kPa) 8.5˝ W.C. (2.12 kPa) 14˝ W.C. (3.49 kPa) 14˝ W.C. (3.49 kPa)
BTH-300(A) 0˝ W.C. (0 kPa) 0˝ W.C. (0 kPa) 4.8 ˝ W.C. (1.19 kPa) 8.5˝ W.C. (2.12 kPa) 14˝ W.C. (3.49 kPa) 14˝ W.C. (3.49 kPa)
BTH-400(A) 0˝ W.C. (0 kPa) 0˝ W.C. (0 kPa) 4.8 ˝ W.C. (1.19 kPa) 8.5˝ W.C. (2.12 kPa) 14˝ W.C. (3.49 kPa) 14˝ W.C. (3.49 kPa)
BTH-500(A) 0˝ W.C. (0 kPa) 0˝ W.C. (0 kPa) 4.8 ˝ W.C. (1.19 kPa) 8.5˝ W.C. (2.12 kPa) 14˝ W.C. (3.49 kPa) 14˝ W.C. (3.49 kPa)
MANIFOLD PRESSURE MINIMUM SUPPLY PRESSURE MAXIMUM SUPPLY PRESSURE
NATURAL GAS PROPANE GAS NATURAL GAS PROPANE GAS NATURAL GAS PROPANE GAS
For Technical Information and Automated Fax Service, call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
www.hotwater.com
Page 2 of 4
AOSCG10210