A.O. Smith ATI-110-N, ATI-110-P, ATI-310-P, ATI-510-P, ATO-110-N Technical Documents

...
Residential Gas Tankless Water Heaters
TANKLESS RESIDENTIAL MODELS
Fully modulating, gas fired, tankless water heater convertible to sealed combustion with power-vented flue. Supplies hot water to domestic hot water systems (directly or indirectly).
FEATURES
CONTINUOUS MAXIMUM FLOW RATES UP TO 6.6 GPM
ENERGY STAR
AVAILABLE FOR NATURAL GAS OR PROPANE
MODELS INCLUDE REMOTE CONTROL AND POWER CORD AS STANDARD FEATURES
SAFETY FEATURES:
Built in Freeze Protection Manual Reset Hi Limit (Set at 194°F) Overheat Cutoff Fuse Inlet and Outlet Thermistors for Constant Temperature Monitoring Flue Backdraft Pressure Switch GFI Power Supply Connection Flame Sensor
QUALIFIED
ATI-110-N
ATI-110-P
VENTING AND COMBUSTION
4” Category III Stainless Steel Vertical or Horizontal Installation 50’ Max Length, 5 elbows max (90° elbows = 5’ equivalent length) Power Vent Electronic Ignition - No Pilot Light 3” Combustion Air Intake (with optional kit)
OPTIONAL ACCESSORIES
Complete line of Stainless Steel Venting Pipe Cover Direct Vent Conversion Kit Isolation Valve Kits
Concentric Vent Kits Isolation Valve Kit (includes Pressure Relief Valve)
WARRANTY
15-year limited warranty on heat exchanger in residential applications 5-year warranty on all parts
ANSI Z21.10.3
CSA 4.3
May 2013
Page 1 of 2
CANRG46815
Residential Gas Tankless Water Heaters
TANKLESS RESIDENTIAL MODELS
GAS
CONSUMPTION
INPUT
MODEL
NUMBER
FUEL TYPE
MIN.
BTU/H
MAX.
BTU/H
ATI-110-N Natural 19,500 140,000
ATI-110-P Propane 19,500 140,000
INLET GAS
ENERGY
FACTOR
(EF)
PRESSURE
MIN.
W.C.
MAX.
W.C.
MAX
GPM**
0.82 5.0 10.5 6.6 20-1/4 13-3/4 7-3/4 120 0.61 4” O.D. 3.0” O.D. 3/4” NPT 38
0.83 8.0 14.0 6.6 20-1/4 13-3/4 7-3/4 120 0.61 4” O.D. 3.0” O.D. 3/4” NPT 38
DIMENSIONS
IN INCHES
HEIGHT WIDTH DEPTH
All dimensions are in inches. 15-150 psi water pressure. 40 psi or above recommended for maximum flow. * Category III required **Current numbers based on factory testing, 0.4 GPM required for continuous fire after initial ignition. Pressure only relief valve requires (Min. 200,000 BTUs. 150 PSI).
Pressure Loss
7
6
5
Pressure
Loss (psi)
Head
Feet
4
3
2
Flow Rate (GPM)
1
0
0 20 40 60 80 100 120 140
HOT/
COLD/
VOLT AMP FLUE*
Comparison of Flow Rates vs. Temperature Rise
(OPTIONAL)
Temperature Rise (°F)
INTAKE
GAS
CONN.
APPROX.
SHIPPING
WEIGHT
(LBS)
CLEARANCES: Top 12”, Bottom 12”, Front 24”, Back 1”, Sides 2”
DIMENSIONS
4" (102mm)
2-1/4" (57mm)
1" (26mm)
2-1/4" (56 mm) COLD
3-7/8" (98mm) GAS 4-7/8" (123mm) 120V 4-7/8" (124mm) HOT 7-3/4" (196mm)
1-3/4"(45mm)
21-3/8" (544mm)
1-7/8" (47mm)
COLD 3-1/8" (79mm) HO T5-1/4" (133mm)
20-1/4" (520mm)
13-3/4" (350mm)
10" (254mm)
For Technical Information call 1-888-479-8324. A. O.Smith Corporation reserves the right to make product changes or improvements without prior notice.
Ø 3-9/8" (101 mm)
1-3/4" (45mm)
2-1/4" (56mm)
120V 1-3/8" (36mm) GAS 4-7/8" (124mm)
May 2013 Page 2 of 2
www.hotwatercanada.ca CANRG46815
Loading...