A.O. Smith ATI-510-N, ATO-510-N Technical Documents

Residential/Light Commercial Gas Tankless Water Heaters
TANKLESS RESIDENTIAL/LIGHT COMMERCIAL MODELS
Fully modulating, gas fired, tankless water heater specifically designed for residential and light commercial applications. Capable of supplying hot water for domestic hot water systems or combination heating and domestic heating applications (local codes dictate proper compliance). Features HRS35 copper alloy and a thicker heat exchanger drum for added durability. Up to four units can be easily linked, using the Easy-Link system, without a multi-unit controller in systems for larger applications.
FEATURES
HEAT EXCHANGER IS CONSTRUCTED OF HRS35 COPPER
Stronger than standard copper and more resilient against erosion and heat stress
CONTINUOUSMAXIMUM FLOW RATES UP TO 10.0 GPM
CAN BE USED IN BOTH RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS
®
ENERGY STAR
MODELS INCLUDE REMOTE CONTROL AND POWER CORD AS STANDARD FEATURES
EASY-LINK UP TO4UNITS
With no additional partsor accessories needed
Includes Temperature Controller
SAFETY FEATURES:
Built in Freeze Protection
Manual Reset Hi Limit(Set at 194°F)
Overheat CutoffFuse
Inlet, Outlet&Mixing Thermistors for Constant Temperature Monitoring
Surge Bar Power Supply Connection
Flame Sensor
VENTING AND COMBUSTION
4” Category III Stainless Steel
Air Fuel Ratio Rod
VerticalorHorizontal Installation
50’Max Length,5elbowsmax (90° elbows=5’ equivalent length)
Power Vent
Electronic Ignition -No Pilot Light
3” Combustion Air Intake (with optional kit)
OPTIONAL ACCESSORIES
Direct Vent Conversion Kits
Complete Line of Stainless SteelVenting
Pipe Cover
Isolation Valve Kits (includes Pressure Relief Valve)
Concentric Termination Kits
WARRANTY
15-year limited warranty on heat exchangerin residential applications
10-year limited warranty on heat exchangerin commercial applications
5-year warranty on all parts
QUALIFIED
ATI-510-N
ATI-510-P
ANSI Z21.10.3 CSA 4.3
January 2013
Page 1of2
CANBG45000
Residential/Light Commercial Gas Tankless Water Heaters
TANKLESS RESIDENTIAL/LIGHT COMMERICAL MODELS
GAS CONSUMPTION
INPUT
MODEL
NUMBER
FUEL TYPE
MIN.
BTU/H
MAX.
BTU/H
ENERGY
FACTOR
0.83
ATI-510-P Propane 11,000 199,000 0.82 8.0 14.0 10.0
All dimension are in inches. 15-150 psi water pressure.40psi or above recommended for maximum flow. *Current numbers basedon factory testing, 0.4 GPM required for continuous fire after initial ignition. **Category III Required Pressure only relief valve requires(Min. 200,000 BTUs. 150 PSI).
510 Pressure Loss
Pressure
Loss (psi)
Flow Rate (gpm)
INLET GAS PRESSURE
MIN.
MAX.
W.C.
W.C.
MAX
HEIGHT WIDTH DEPTH
GPM*
20-1/2 13-3/4 8-1/2
20-1/2 13-3/4 8-1/2
Head
Feet
DIMENSIONS
CLEARANCES:Top 12”, Bottom 12”, Front 24”, Back 1”, Sides2”
(INCHES)
VOLT AMP FLUE**
INTAKE
(OPTIONAL)
HOT/COLD
GASCONN.
0.75
120 0.75
4” O.D. 3” O.D. 3/4” NPT 45
Comparison of Flow Rate vs. Temperature Rise
12.0
11.0
10.0
9.0
8.0
7.0
6.0
FlowRate (gpm)
5.0
4.0
3.0
2.0
1.0
0.0
020406080100 120140
Temperature Rise (°F)
SNOISNEMID
APPROX.
SHIPPING
WEIGHT
(LBS)
13-3/4" (350mm)
1-3/4" (45mm) 1-3/4" (45mm)
21-3/8" (544mm)
1-7/8" (47mm)
COLD 3-1/4" (84mm)
HOT 5-1/4" (133mm)
10" (254mm)
20-1/4" (520mm)
Ø4 " (101 mm)
1-3/8" (36mm)
120V 1-3/8" (36mm)
GAS 4-7/8" (124mm)
COLD 2-7/8" (71mm)
120VAC3-7/8"(99mm)
GAS 5-1/4" (135mm) HOT6-1/2"(164mm)
4-3/8" (113mm)
1-5/8" (43mm)
19-3/8"(493mm)
1" (26mm)
9-1/2" (241mm)
Specification
Water heater(s) shall be Model _________________ as manufactured by A. O. Smith. The water heater(s) shall be a copper coil integral fin and tube construction with quick release brass or bronze waterways. Heater(s) will be factory assembled and tested. The heater shall be vented with 4” Stainless steel Category III vent pipe a distance not to exceed 50’ (equivalent) feet terminating vertically or horizontally as prescribed. Intake air with optional direct vent kit may be of such material as ULC s636 PVC or CPVC, galvanized B-Vent, corrugated aluminum or stainless steel or Category IV stainless steel not to exceed a total of 50’ (equivalent). The heater(s) shall be controlled by onboard solid state printed circuit board monitoring incoming and outgoing temperatures with factory-installed thermistors, sensing and controlling flow rate to set point temperature with control both air and gas mixture inputs to maintain thermal combustion efficiency. Unit also consists of, inline fusing, spark ignition and sensor system, aluminized stainless steel burners, air-fuel ratio rod, Hi limit switch, modulating and proportional gas valves, freeze protection sensor and heating blocks and overheat cutoff fuses. The water heater(s) shall be CSA listed, exceeds the energy efficiency requirements of ASHRAE 90. 1b-1992.
For Technical Information call 1-888-479-8324. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
January 2013 Page 2of2
www.hotwatercanada.ca CANBG45000