A. J. ANTUNES & CO. 180 Kehoe Blvd., Carol Stream, Illinois 60188
Bin Drain Water Outlet
< 12 o'clock position >
(To Floor Drain)
Bin Drain
Connection #3
Connection #2
Connection #4
Water Inlet
(From Bin Drain)
Tap Water Outlet
(To ice machine inlet)
(insulate)
Alternate Bin Drain Water Outlet
< 6 o'clock position >
(Install included plug)
Tap Water Inlet
Connection #1
(From Wall or Filter)
CHILL ICE-S INSTALLATION INSTRUCTIONS (P/N 9700923)
SUGGESTED MATERIALS AND EQUIPMENT NEEDED:
• (10 ft.) 3/4” PVC Pipe
• (4) 3/4” PVC Elbow Fitting
• (10 ft.) 3/8” OD Copper Tubing
• Multipurpose glue for ABS, PVC, and CPVC
• Tubing Cutter
• PVC Pipe Cutter
• Screwdriver or Drill with Bits
• Channel-Lock Pliers
• Adjustable Wrench
• Measuring Tape
General
If you experience any problems with these instructions,
contact the Technical Service Department at 630-784-1000
or toll free in the U.S. at 877-392-7854.
Figure 1. Connections
Warranty Information
All ICE-S units will be free from defects in materials and workmanship for a period of five years.
Installing the ICE-S
To ensure material compatibility, a multipurpose glue for ABS,
PVC, and CPVC must be used. This will ensure a proper bond
between the 3/4” PVC and the black ABS Bin Drain Water Inlet
(Connection #3).
If a water filter is being used, install the ICE-S unit between the
filter and the ice machine.
The ICE-S unit has two Bin Drain Water Outlets on the top of
the cap to allow position of the unit on either side of the ice
machine.
1. Turn off the ice machine and the water supply.
NOTE: The ICE-S unit must be installed to the underside of
the bin or to the wall below the bin drain level.
2. Place the ICE-S on its side (horizontally) and attach it to
the ice bin with mounting straps.
3. Position the ICE-S unit so the two 3/4” PVC Drain Water
Outlets are oriented in the 12 o’clock and 6 o’clock positions.
4. Glue the PVC plug in the 6 o’clock PVC Drain Water Outlet.
7. Connect the tap water line to the Tap Water Inlet on the
ICE-S (Connection #1) with 3/8” copper tubing. Be sure to
push the tubing 3/4” into the quick connector so the tubing is
fully seated.
NOTE: The ICE-S unit uses 3/8” quick connectors instead of
flared or compression fittings.
NOTE: Use caution when cutting the copper tubing to not flatten or pinch the ends to be inserted into the quick connectors.
NOTE: To remove the copper tubing, hold down the dark gray
gripper ring next to the tubing, then push the tubing in and
pull out in one continuous motion.
8. Connect the ice machine inlet to the Tap Water Outlet on the
ICE-S (Connection #2) with 3/8” copper tubing.
9. Use the included insulation material to insulate the tubing
running from the Tap Water Outlet on the ICE-S to the ice
machine inlet.
10. Check for any water leaks.
5. Connect the ice bin drain line to the Bin Drain Water Inlet on
6. Install a PVC drain line from the Bin Drain Water Outlet on
1-877-392-7836 Fax: 630-784-1000 Page 1 of 1 P/N 1011077 Rev. A 05/10
the ICE-S (Connection #3).
the ICE-S (Connection #4) to the drain.