Central heating furnace designs are
certified by the American Gas Association for both natural and L.P. gas.
Limit setting and rating data were established and approved under standard rating conditions using American
National Standards Institute standards.
Safe Operation
The Integrated System Control has
solid state devices, which continuously monitor for presence of flame,
when the system is in the heating
mode of operation. Dual solenoid combination gas valve and regulator provide extra safety.
Quick Heating
Durable, cycle tested, heavy gauge
aluminized steel heat exchanger
quickly transfers heat to provide warm
conditioned air to the structure.
Burners
Multi-port In-shot burners will give
years of quiet and efficient service. All
models can be converted to L.P. gas.
Integrated System Control
Exclusively designed operational program provides total control of furnace
limit sensors, blowers, gas valve,
flame control and includes self-diagnostics for ease of service. Also contains connection points for E.A.C./
Humidifier.
Air Delivery
The multispeed, direct drive blower
motor, with sufficient airflow range for
most heating and cooling requirements, will switch from heating to
cooling speeds on demand from room
thermostat. The blower door safety
switch will prevent or terminate furnace operation when the blower door
is removed.
Styling
Heavy gauge steel and “wrap-around”
cabinet construction is used in the
cabinet with baked-on enamel finish
for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass
insulation. This results in quiet and efficient operation due to the excellent
acoustical and insulating qualities of
fiberglass.
Features And General Operation
The FREEDOM 80 High Efficiency
Gas Furnaces employ a Hot Surface
Ignition system, which eliminates the
waste of a constant burning pilot. The
integrated system control lights the
main burners upon a demand for heat
from the room thermostat. Complete
front service access.
a. Low energy power venter.
b. Vent proving differential switch.
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DUCT CONN.
DIMENSIONS
Crated (In.)
Uncrated
WEIGHT
Shipping (Lbs.)/Net (Lbs.)
1
Central Furnace heating designs are certified by AGA and ETL.
2
For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian
applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3
Based on U.S. government standard tests.
4
The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DUCT CONN.
DIMENSIONS
Crated (In.)
Uncrated
WEIGHT
Shipping (Lbs.)/Net (Lbs.)
1
Central Furnace heating designs are certified by AGA and ETL.
2
For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian
applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3
Based on U.S. government standard tests.
4
The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DUCT CONN.
DIMENSIONS
Crated (In.)
Uncrated
WEIGHT
Shipping (Lbs.)/Net (Lbs.)
1
Central Furnace heating designs are certified by AGA and ETL.
2
For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian
applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3
Based on U.S. government standard tests.
4
The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
4
AUD2C100A9612A
3
3
ALUMINIZED STEEL TYPE 1
REDUNDANT - TWO STAGE
65000
52000
100000
79000
81.1
30 - 60
DIRECT
10 x 10
1
4
SEE FAN PERF. TABLE
3/4
1075
115/1/60
CENTRIFUGAL
DIRECT - 2
1/50 - 3000
115/1/60
0.93
YES
HIGH VELOCITY
1 - 24 X 25 - 1 IN.
4 ROUND
20
5 - 45
5 - 56
HOT SURFACE
IN-SHOT
5
115/1/60
12.8
15
1/2
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 26-1/2 X 30-1/2
SEE OUTLINE DRAWING
175/163
AUD2D120A9542A
78000
62400
120000
94000
80.0
35 - 65
DIRECT
11 x 10
1
4
SEE FAN PERF. TABLE
3/4
1075
115/1/60
CENTRIFUGAL
DIRECT - 2
1/50 - 3000
115/1/60
.95
YES
HIGH VELOCITY
1 - 20 X 25 - 1 IN.
4 ROUND
ALUMINIZED STEEL TYPE 1
20
6 - 45
6 - 56
REDUNDANT - TWO STAGE
HOT SURFACE
IN-SHOT
6
115/1/60
12.8
15
1/2
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 23 X 30-1/2
SEE OUTLINE DRAWING
176/165
AUD2D120A9602A
78000
62400
120000
95000
80.0
30 - 60
DIRECT
11 x 10
1
4
SEE FAN PERF. TABLE
3/4
1075
115/1/60
CENTRIFUGAL
DIRECT - 2
1/50 - 3000
115/1/60
.95
YES
HIGH VELOCITY
1 - 24 X 25 - 1 IN.
4 ROUND
ALUMINIZED STEEL TYPE 1
20
6 - 45
6 - 56
REDUNDANT - TWO STAGE
HOT SURFACE
IN-SHOT
6
115/1/60
12.8
15
1/2
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 26-1/2 X 30-1/2
SEE OUTLINE DRAWING
186/174
AUD2D140A9602A
91000
72800
140000
111000
80.0
40 - 70
DIRECT
11 x 10
1
4
SEE FAN PERF. TABLE
3/4
1075
115/1/60
CENTRIFUGAL
DIRECT - 2
1/50 - 3000
115/1/60
.95
YES
HIGH VELOCITY
1 - 24 X 25 - 1 IN.
4 ROUND
ALUMINIZED STEEL TYPE 1
20
7 - 45
7 - 56
REDUNDANT - TWO STAGE
HOT SURFACE
IN-SHOT
7
115/1/60
13.0
15
1/2
SEE OUTLINE DRAWING
H X W X D
41-3/4 X 26-1/2 X 30-1/2
SEE OUTLINE DRAWING
193/181
812-1263-02
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.