Amcor D950E, D850E User Manual

D850E D950E
DEHUMIDIFIER - LUFTENTFEUCHTER
DESHUMIDIFICATEUR - LUCHTONTVOCHTIGER
• Instruction manual
• Bedienungsanleitung
• Notice d’emploi
• Gebruiksaanwijzing
ENGLISH
NEDERLANDS
FRANÇAIS
Allgemeine Sicherheit
For safety reasons, read this manual carefully before operating. Persons who are not familiar with this manual must not use this dehumidifier. We strongly recommend keeping this manual in a safe place for future reference.
Für Ihre Sicherheit: Gebrauchsanweisung vor Inbetriebnahme sorgfältig lesen! Personen, die mit der Gebrauchsanweisung nicht vertraut sind, dürfen den Luftentfeuchter nicht bedienen. Wir empfehlen Ihnen, diese Anleitung an einem sicheren Ort aufzubewahren.
Veuillez bien étudier ce mode d’emploi et respecter les consignes de sécurité. Les personnes n’ayant pas lu ce mode d’emploi ne doivent pas utiliser ce déshumidificateur. Nous vous conseillons vivement de conserver ce manuel dans un endroit sûr pour future référence.
Sécurité en général
General safety
Veiligheid algemeen
Bestudeer voor de veiligheid deze gebruiksaanwijzing zorgvuldig! Personen, die met de gebruiksaanwijzing niet vertrouwd zijn, mogen deze luchtontvochtiger niet gebruiken. Wij raden u aan deze gebruiksaanwijzing op een veilige plaats te bewaren voor latere raadpleging.
2
4
fig. 1 fig. 2
fig. 3
fig. 4
Filter
Dry air Trockene Luft Air sechée Droge lucht
Moist air Feuchte Luft Air humide Vochtige lucht
Fan Ventilator Ventilateur Ventilator
Compressor Kompressor Compresseur Compressor
Outlet Auslaß Evacuation Afvoer
Cooling elements Kühlelemente Eléments refroidisseurs Koelelementen
2
5
1
6
3
2
3
3
4
fig. 5
Back cover Rückwand Panneau Achterpaneel
Wall Wand Mur Muur
1
3 2
4
5
3
Thank you!
It is important that you read these instructions before using your new dehumidifier and we strongly recommend keeping them in a safe place for future reference.
Thank you for choosing this innovative Amcor dehumidifier. The instruction manual describes the many benefits and advanced features that this unique product has to offer.
The Amcor dehumidifier is a large capacity unit designed to run highly efficiently in places such as: restaurants, bars, printing presses, indoor swimming pools, jacuzzis, garages, animal enclosures, cellars, stores, boat sheds,
This appliance must be earthed and should only be connected to an earthed 230 V/50 Hz mains. The installation must be in accordance with the regulations of the country where the unit is used. The unit is designated for indoor operation.
• The dehumidifier is safe. It has been approved by many safety institutions around the world. However, as with other electrical appliance, use it with care.
• Keep out of reach of children.
• Do not clean the dehumidifier by spraying it or immersing it in water.
• Do not insert any object into the opening of the dehumidifier.
• Disconnect from the mains before cleaning the unit or any of its components.
• Never connect to an electrical outlet using an extension cord. If an outlet is not available, one should be installed by a licenced electrician.
• Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to do so could result in a loss of warranty.
• When the unit is placed in a (swimming) pool, connect to the mains via a transformer or a breaking switch, conform the regulations regarding electrical installations.
Your Amcor dehumidifier is supplied with an electrical cable and an earthed plug. Should it be necessary to replace this plug at any time, you must use an earthed electrical plug.
Warning Never operate this appliance if it has a damaged cord or plug.
If the supply cord is damaged, it must be replaced by an approved service representative or a similar qualified person in order to avoid any hazards.
There should be direct access to the electrical plug after connecting the power!
GB
Thank you!
Safety
Safety
Instruction manual
Instruction manual
The first time that you use this dehumidifier please ensure that it has been standing for 24 hours in an upright position before it is switched on.
weekend cottages, archives, etc.
For over 50 years, Amcor has specialised in complete indoor environment control, manufacturing: dehumidifiers, portable air conditioners, coolers, air purifiers/ionisers and aromatherapy products. These world class products incorporate the latest technological developments and are designed to create a quality environment.
4
GB
See page 3, fig. 3
Your Amcor dehumidifier controls the Relative Humidity by passing the air through the unit forcing the excess moisture to condensate over the cooling elements.
This condensate water then flows safely
How it works
How it works
Your Amcor dehumidifier can be installed in any area with a too high relative humidity, such as cellar, playing area, shed, archive or swimming pool.
The dehumidifier will begin to protect from the harmful effects of excess moisture as soon as it is plugged in and switched on.
When positioning your Amcor dehumidifier, ensure that it is placed on a level surface.
Positioning the dehumidifier
Positioning the dehumidifier
into a fixed drain.
The dried air then passes through a final heat exchanger where it is slightly warmed and re-enters the area at a slightly elevated temperature.
The level of demoistering is set with the humidistat control.
Best results are obtained when windows and doors are closed, thus preventing the possible influx of fresh, too humid, air.
When the unit is placed in a (swimming) pool, connect to the mains via a transformer or a breaking switch, conform the local regulations regarding electrical installations.
When the dehumidifier is in operation, open outside doors and windows only when necessary.
There must be free space of at least 30 cm between any other object and the front and the top of the unit.
See page 3, fig. 5
The unit can stand on the floor or hung on a wall. All necessary items for wall mounting are supplied in the plastic bag.
Fix the supporting bracket with at least 5 screws horizontally to the wall, use the plugs for better fastening.
Wall mounting
Wall mounting
Hang the unit on the bracket, the two tongues fit into the slots on the unit’s rear panel.
Make sure the two rubber pads (3) on the tongues and the two rubber supports (4) on the lower part of the rear panel are properly placed.
5
GB
There are four optional outlets for the drainage tube. To change the outlet of the drainage tube the rear panel should be dismounted. When remounting the rear panel care should be taken to return all the screws and washers to their original location.
Connecting the permanent outlet
• Connect the pipe to an outlet tube with
the correct diameter.
Drainage
Drainage
See page 3, fig. 4
ON/OFF (1) The unit is switched on and off by pressing the ON/OFF button (1). When the unit is on, the fan runs in the set speed.
Humidity (2) Press the HUMIDITY button (2) repeatedly to choose the desired level of relative humidity in the area. The corresponding control lights (2) will indicate the selected percentage. The yellow CNT control light (5) indicates that the unit is running continuously, disregarding the relative humidity level in the area.
Ventilator speed (3) Press the SPEED button (3) to select low or high speed. The corresponding control light (3) will indicate this, Lo=low or Hi=high.
Controls
Controls
Digital display (4) The digital display (4) will show the measured relative humidity in the area.
Compressor (6) The COMP control light (6) will be on when the compressor is running. An automatic time delay of five minutes before the compressor can (re-)start working is a safegarde against damage.
IMPORTANT:
This dehumidifier should not be used in temperatures below 7 °C or above 35 °C.
Defrost Control
The dehumidifier is equipped with an automatic de-icing mode to defrost the refrigeration coil during low temperature operation. The compressor is switched off whilst the ventilator continues to run.
• Push the other end of the tube into a drain, making sure that the tubing cannot be twisted or folded.
• The entire length of the tube must be slightly inclined.
• Ensure that the outlet of the drainage pipe is NOT under the water level in the drain.
NOTE: In very cold weather conditions precautions should be taken to prevent the drainage pipe from freezing.
6
Loading...
+ 14 hidden pages