Thank You ……………………………………………………… 1

Safety Instructions …………………………………………… 1-2

Specifi cations …………………………………………………… 3

Parts …………………………………………………………… 4

AutoDrain NanoMist TechnologyAssembly …………………… 5

Positioning ……………………………………………………… 6

Operation …………………………………………………… 7-8

Emptying the Water Container ………………………………… 9

Cleaning …………………………………………………………10

Installation of the Filters …………………………………………10

Storage……………………………………………………………11

Troubleshooting …………………………………………………12

Limited Warranty …………………………………………………14

Thank You!

Thank you for purchasing an AMCOR Portable Air Conditioner.

AMCOR is a leading brand in indoor air treatment. We would like you to enjoy the many benefits this unit offers, so please read this manual carefully and take full advantage of the many advanced features that your AMCOR Air Conditioner offers you.

AMCOR has specialized in complete indoor environment control, manufacturing

world-class heaters, air conditioners, dehumidifiers and air purifiers with innovative technology.

In designing these advanced products, we have listened carefully to our customers and have passed their views on to our research and development laboratories.

We wish you many years of enjoyable use.

After reading this manual, please keep it in a safe place for future reference.

Read this entire instruction manual before use.

Please keep your receipt. Your receipt is your Proof of Purchase and is necessary for warranty service.

Safety Instructions

IMPORTANT!

The unit is designed for indoor operation.

Rating: This unit must be connected to a 115V/60Hz grounded outlet.

The installation must be in accordance with regulations of the country where the unit is used.

If you are in any doubt about the electrical installation, have it checked and if necessary modified by a qualified electrician.

The air conditioner is safe. However, as with other electrical appliances, use it with care.

Keep out of the reach of children.

Do not clean the unit by spraying it or immersing it in water.

Do not insert any object into the openings of the unit.

Disconnect the unit from the outlet before cleaning the unit or any of its components.

Never connect the unit to an electrical outlet using an extension cord.

If an outlet is not available, one should be installed by a licensed electrician.

WARNING!

Never operate this appliance if it has a damaged cord or plug. Do not lead the cord over sharp edges.

A damaged supply cord should be replaced by the manufacturer, its service agent or a qualified person in order to avoid a hazard.

Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to do so could result in a loss of warranty.

1

Safety

Do not use your air conditioner:

If the power cable wires are frayed or cut

When small children may be

 

On a slope or uneven surface

Close to a heat source

left unattended

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This products is not made for DIY repair

If there is a risk of liquid falling on the unit

Inside unit exposed to the weather outdoors

In a permanent very humid environment

If an extension lead may become overloaded

Where the power cable may be damaged

Where it may be damaged by chemicals

Where there is a risk of interference by foreign objects

Reminder:

Waste electrical products must not be disposed of with household waste. This product should be taken to our local recycling center for safe treatment.

2

Specifications

Model

 

CF14000E

 

 

 

Cooling Capacity (BTU/hr)

 

14,000

 

 

 

Cooling Power Consumption

/ Current

1150W/10.2A

 

 

 

Heating Power Consumption

 

Feature not available

 

on this model

 

 

Dehumidification in Cooling Mode

62 Pints / 24h

 

 

 

Moisture Removal in Heating

Mode

N/A for this model

 

 

 

Power Supply

 

115V / 60Hz

 

 

 

Refrigerant

 

R22

 

 

 

Compressor

 

Rotary

 

 

 

Fan Speeds

 

2

 

 

 

Thermostat

 

62º - 90º F

 

 

 

Timer

 

1 - 12 Hours

 

 

 

Dimensions

 

12"W x 18"D x 30"H

 

 

 

Weight

 

63 lbs.

 

 

 

Subject to modifications without prior notice.

Please refer to the rating label for greater precision.

The cooling capacity of the unit may be affected by the height of your ceiling, quality of your insulation,or number of windows in your room. There is no current testing statute for portable air conditioningproducts in the United States, yet we have made every effort to design engineer a superior qualityportable air conditioning unit that effectively and efficiently cools select areas of the home or office.These portable air conditioning units are designed engineered to provide supplemental air conditioning.To gain a better understanding of the performance capabilities of your new Amcor portable AC unit,you can visit us online at: www.amcorgroupusa.com/portableacdisclaimer

3

Amcor CF14000E User Manual

Parts

1

2

3

4

5

6

7

4

8

9

 

1.

Handle

 

2.

Control panel

10

3.

Air outlet

11

4.

Air inlet with filter

5.

Exhaust hose

 

 

6.

Power cord hanger

 

7.

Exhaust air outlet

 

8.

Water stopper (plug inside)

 

9.

Casters

14

10.

Adjustable Window Slide Bar

12

11.

Flexible Drain Hose

13

12.

Exhaust hose

 

15

13.

IR Ergonomic Remote Control

16

 

 

 

14.

Exhaust Hose Window

 

 

Slide Bar Connector

 

15.

Insulation tape

 

16.

Spiral water pipe with connector

4

AutoDrain NanoMist TechnologyAssembly

1

Stretch end of

2

the hose slightly.

 

Attach Window

 

 

Slide Bar

 

 

Connector to

 

 

Exhaust Hose by

 

 

twisting as shown.

 

Put spiral water pipe into hot air flexible hose.

3

5

7

Connect the

4

female half of the

quick connector

 

at the end of the

 

spiral water pipe

 

to the male part

 

in the hot air

 

outlet pipe.

 

Stretch end of

 

 

6

the hose slightly.

Assemble the hot

 

air hose on the

 

unit by screwing

 

in clockwise.

 

 

 

Unfold flexible

hose with attached 8 hose adapter

connector, and snap into Window Slide Bar.

Turn the connector 90º clockwise

until it is locked in place.

Clip on the water atomizer at the end of the spiral pipe to the holder.

Only

Required For

Disassembly.

In order to unlock the quick connector, push the tab and turn the connector counterclockwise.

5

Positioning

This unit can easily be moved from one room to another. In doing so keep this in mind:

The air conditioner must stand upright on an even surface.

Do not position near bath, sink, or other permanent wet or damp area.

Keep unit at least 18" from wall, curtains, draperies, to insure adequate air circulation.

1

2a

2b

Installing Exhaust Hose to Window Slide Bar

After assembling Innovative AutoDrain NanoMist Technologyper instructions on page 5, make sure hose is firmly attached to oval connecter that fits into window slide bar.

Snap hose connecter into window slide bar opening. See Illustration 1.

Extend window slide bar to fit your window opening, either vertical or horizontal, depending on how the window opens. See Illustrations 2a-2b.

Important

The flexible exhaust hose can be extended from 12" to 60" for mounting.

This length has been designed especially according to the specifications of the air conditioner.

Do not use an extension or exchange for a different hose as that may lead to malfunctioning.

The exhaust air must flow freely, any blockage can lead to overheating of the air conditioner. Take care to prevent any kink or bend in the exhaust hose.

6

WATER FULL

Operation

5

1

 

 

 

 

HI

 

 

 

 

LOW

WATER

AUTO

 

 

COMP

FULL

COOL

FAN

MODE

2

4

1. ON/OFF

3

Press the ON/OFF-button to switch the unit on or off.

2. Setting the Timer

Press the TIMER button, which will start the timer counter function.

Each press of the timer button will advance the timer setting by 1 hour, for setting 1-12 hours. If you pass the desired hour setting, you must advance the numbers completely through 12, to start timer count from 1. When set, the TIMER LED will light up.

When the set hours have elapsed, the unit will turn off automatically.

The display will show the hour(s) remaining when you press the TIMER button.

By pressing the TIMER button but without turning the unit on, you can pre-set in how many hour(s) the unit will switch on automatically.

3. Setting the Operating Mode

Select the required operating mode: COOL, FAN, or AUTO. The corresponding LED will lit. In AUTO mode the unit will select cooling or fan depending on the ambient temperature.

4. Fan Speed

Select the fan speed, the corresponding LED will lit: LOW or HIGH.

5. Increase UP or DOWN

When the unit is ON, the display always shows the room temperature.

Press button UP or DOWN to see the current set temperature and adjust if necessary, in the range of 62ºF to 90ºF. After 8 seconds, the room temperature will be displayed.

Warning lights COMPRESSOR and WATER FULL

When the water container is full, the unit automatically stops, the warning light

will flash to signal that the container must be emptied (see page 9, “Emptying The Water Container”).

When the unit is cooling, the compressor light will be on. If this light is off further cooling is not needed at this time, or the compressor may be de-icing its coils.

The fan can still be on.

7

Operation

Remote control

The air conditioner responds to all signals that are sent by the remote control. Two AAA-batteries are required to use the remote control. Point the remote control hand set towards the control panel of the unit and press the relevant button, the red LED on the hand set will flash whenever a button is pressed.

Note: the air flow direction can not be adjusted with the remote control.

Air flow

Adjust the left-right direction of the outflowing air by turning the roller on the front of the air outlet grill.

Adjust the up/down air flow by rotating the air outlet grill.

Important:

The compressor will start approximately 3 minutes after the unit is turned on (this will help prolong the life of the compressor). After switching the unit off, please wait at least 3 minutes before turning the unit back on.

The compressor will switch off when the room temperature is lower than the set temperature. The fan will however continue to work. When ambient temperature rises above the set temperature, the cooling will resume.

8