Amcor AM-45 User Manual

AM-45
Air Purier
空氣淨化機
空气净化器
GB
TC
說明書
SC
用户手册
www.amcorgroup.com
GB
Thank You!
Thank you for choosing this innovative Amcor air Purier. We suggest that you keep this manual in a safe place for future reference. It describes the many benets and advanced features this unique product has to offer. Before you use your new air Purier you should carefully read these instructions to maximise this product’s performance.
For over 50 years Amcor has specialised in complete indoor environmental control, manufacturing and marketing dehumidiers, portable air conditioners, coolers, air puriers, ionisers and aroma therapy scent diffusers. These world class products incorporate the latest technological developments.
Energy Saving Tips
• Do not locate the Air Purier where furniture or other objects can obstruct the airow.
• Follow the maintenance instructions in order to keep the lters clean.
Do not use your air purier under the following conditioners:
If the power cable wires are frayed or cut
This product is not made for DIY repair
If an extension cord is needed to reach an outlet
When small children may be left unattended
If there is a risk of liquid falling on the unit
Where the power cable may be damaged
On a slope or uneven surface
Inside unit exposed to the weather outdoors
Where it may be damaged by chemicals
Close to a heat source
In a permanent very humid environment
Where there is a risk of interference by foreign objects
GB
This manual has been prepared to acquaint you with the proper installation, operation and maintenance of your AM-45 Air Purier. We urge you to read this publication carefully and to follow the recommendations to help assure the most enjoyable and trouble free operation of your Amcor unit. When it comes to service, remember that Amcor knows its product best. Please do not attempt to open, repair and/or clean any of the internal parts of the AM-45 Air Purier yourself. This could result in loss of the warranty. We would like to take this opportunity to thank you for choosing an Amcor product, and to assure you of our continuing interest in your comfort, pleasure and health.
Safety
• The AM-45 Air Purier is safe. It is TUV certied product and it has been designed with special attention to safety. However, as with other electrical appliances, use it with care.
• Do not clean the AM-45 Air Purier by spraying it or immersing it in water.
• Do not insert any object into the openings of the AM-45 Air Purier.
• Disconnect the product from the electrical outlet before cleaning the unit or any of its components.
• Do not connect the AM-45 Air Purier to an electric outlet using an extension cord.
If there is no accessible outlet, a licensed electrician should install one.
• WHEN NOT IN USE, STORE OUT OF REACH OF CHILDREN!
• The unit is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Warning
• Any service, other than regular cleaning or lter replacement should be performed by an authorized service representative. Failure to do so could result in loss of warranty.
• To reduce the risk of electric shock,if the plug does not t fully in the outlet, contact qualied personnel to install the proper outlet. Do not alter the plug in any way.
• If the supply cord becomes damaged, it must be replaced by the manufacturer or its service agent or similarly qualied person in order to avoid a hazard.
GB
Features and Benets
• High performance air purier/ioniser for large areas and extended use.
• Electronic Control
• Three Speeds
• A timer that allows the user to operate the unit continuously, or at 1, 2, 4 or 8 hour increments
• Quiet Operation
• Mesh pre-lter
• Electrostatic lter captures even the smallest airborne particles
• Granulated Active Carbon Filter
• PCO (Photo Catalytic Oxidation) lter working in conjunction with a UVA lamp to kill bacteria, viruses and reduce odors.
• Negative air ioniser
Placement of the AM-45 Air Purier
Attention: Before deciding on a location for your AM-45 Air Purier, carefully read all the operating instructions as well as all the following information.
1. Do not place this unit in close proximity to electronic devices that are sensitive to
electrical elds.
2. Do not place this unit on metal shelving or on any electrical device. The AM-45
Air Purier may be placed on the oor, nightstand, table or desk with its air outlet facing the user in order to allow proper air ow.
. In order to prevent dirt build-up it is recommended to keep the unit at least 1.5
ft.(45cm) from any non-washable surface.
The principle upon which the ioniser works is Ionization. The process of ionizing accelerates the fallout of pollutants from the air. These pollutants may adhere to surrounding surfaces, causing a dark smudge. Therefore placement of the unit away from all non-washable surfaces is a must!
4
Control Panel and Remote Control Operation
GB
1. Plug the unit into a 220-240V mains outlet and press the POWER (A) button. The unit will start operating in the lowest speed. The UV lamp and Ioniser will be on. Note that these are always the initial conditions when the unit has been disconnected from the mains power. If the unit is turned on while having remained connected to power, it will turn on with the same UV lamp and Ioniser settings as when it was turned off. The speed setting will also be kept, if the unit is turned on with the TIMER (B) button or Remote Control.
2. With each press on the POWER (A) button, the unit will cycle through the following sequence:
Speed 1 (Lowest speed), Speed 2, Speed 3, Off, Speed 1… The selected speed will be
indicated by the green light next to the “1”, “2”, or “3” printing.
3. With each press on the IONISER (C) button, the Ioniser will cycle on and off. When the Ioniser is on, the green light next to the IONISER (C) button is lit.
4. With each press on the UV (D) button, the UV lamp will cycle on and off. When the UV lamp is on, the green light next to the UV (D) button is lit.
5. The Timer functions, which are controlled by the TIMER (B) button, are as follows:
a. With each press on the TIMER (B) button, the Timer will cycle through the following
sequence:1hr, 2hrs, 4hrs, 8hrs, Timer off (but the unit keeps operating), 1hr…The selected Timer interval (in hours) will be indicated by the green light next to the “1”, “2”, “4” or “8” printing.
D: UV
C: IONISER
B: TIMER
A: POWER
b. The unit will operate for the selected Time interval (1 hr, 2 hrs, 4 hrs or 8 hrs) and then
turn off the unit. After the appropriate time period has passed the green light will move to the next lower position in order to show the remaining time.
6. The Remote Control turns the unit on and off (see point 1 above). For long operating distance the Remote Control should be pointed at the area just below the POWER (A) button.
5
GB
Cleaning and Maintenance
Always disconnect the unit from the electrical outlet prior to cleaning or servicing the unit!
Note that the servicing intervals mentioned in this section are based on air purier use of 12 hours per day in a normal household environment. If your use of the air purier differs from that described above, then you can adjust the servicing intervals accordingly.
1. Clean the outside of the AM-45 and the area around the air purier with a soft damp cloth once every 2 weeks. If you are not using the Ionizer, then this interval can be increased to once a month.
2. Access to the AM-45 lters and serviceable components is by removing the rear cover. To remove the rear cover, push the button above the rear cover while pulling back on the rear cover. The rear cover will pivot away from the main unit and then it can be lifted up and away. The rear cover is reinstalled by tting the projection at the bottom of the rear cover into the slot at the back of the main unit and then closing the top of the rear cover until it snaps into place.
3. The Pre-Filter is removed from the rear cover, by sliding it out the upper edge of the rear cover. The Pre-Filter is reinstalled by sliding it back in the slot from where it was removed. The Pre-Filter should be washed in warm soapy water or with a water spray once a month.
Make sure that the Pre-Filter is completely dry before reinstalling it.
4. Inside the rear cover facing the front of the unit are 6 ionizing needles that work together with the Aluminum Mesh Filter to make the Electrostatic Filter. The needles are inside protective cylinders and the needles should be cleaned with a brush once a month.
5. The Aluminum Mesh Filter is visible looking at the open back side of the main unit. The Aluminum Mesh Filter frame holds both the Aluminum Mesh Filter and the Granulated Active Carbon Filter. Remove the Aluminum Mesh Filter frame by lifting the tab above the
lter and then by pulling backwards towards the user on the upper part of the lter. The Granulated Active Carbon Filter is removed from the Aluminum Mesh Filter frame, by sliding it out the upper edge of the Aluminum Mesh Filter frame. Note that this needs to be done before washing the Aluminum Mesh Filter. The Granulated Active Carbon Filter is reinstalled by sliding it back in the slot from where it was removed. The Aluminum Mesh Filter frame is reinstalled by tting the bottom of the lter frame into its place at the back of the main unit and then closing the top of the lter frame until it snaps into place.
a. The Aluminum Mesh Filter should be washed in warm soapy water once a month.
Make sure that the Aluminum Mesh Filter is completely dry before sliding the Granulated Active Carbon Filter into its place in the Aluminum Mesh Filter frame and reinstalling the lter pair into its place at the back of the main unit.
b. The Granulated Active Carbon Filter should be replaced once a year.
If the Granulated Active Carbon Filter is dusty, it can be cleaned gently with a vacuum cleaner.
g. 1 g. 
GB
c. While the Aluminum Mesh Filter frame is out of the unit, the interior of the unit should
be wiped with a soft dry cloth.
6. The UV lamp (g. 1) is visible looking at the open back side of the main unit after the Aluminum Mesh Filter has been removed. The UV lamp is removed by rotating it 1/4 turn and then sliding it out of the top and bottom lamp sockets.
The UV lamp is reinstalled by sliding it into the top and bottom lamp sockets and rotating it 1/4 turn. The UV lamp should be replaced once a year.
7. The PCO lter (g. 2) is accessible, when the Aluminum Mesh Filter and UV lamp are out of the unit. The PCO lter is removed by lifting the tab above the lter and then by pulling backwards towards the user on the fabric strip at the upper part of the lter. The PCO lter is reinstalled by tting the bottom of the lter into its place at the back of the main unit and then closing the top of the lter until it snaps into place. The PCO lter should be washed in warm soapy water when replacing the UV lamp.
Make sure that the PCO lter is completely dry before reinstalling it.
8. The Carbon Cord which is the negative ion emitting element is accessible at the front grill of the unit. The Carbon Cord should be wiped lightly with a soft piece of paper tissue once every 6 months. The paper tissue should be thrown away after using it.
GB
Specications
Model Number AM-45
Power consumption w 25
UV-lamp, manufactured by Philips Actinic BL ,15W
Power supply 230V / 50Hz
Fan speeds 3
Timer hr 1, 2, 4 or 8
Recommended room size m
Weight kg 4.1
Dimensions (W x H x D) mm 195 x 710 x 235
Nominal Ionization Output: -5.5KV
Total negative ions: 2.5 x 10
12
= 2.5 trillion negative ions per second.
2
50
Safety:
The AM-45 Air Purier is an TUV certicated product.
Ozone:
The ozone level is much lower than permissible by CE safety standards.
• For the most updated specications please refer to the rating label on your machine.