The Amana™ brand RHF TempAssure™ Heat Pumps
offer energy effi ciencies and operating sound
levels that are among the best in the heating and
cooling industry. Our pioneering cubed-coil design
provides superior heating and cooling comfort.
Reliable components, quality manufacturing, high
effi ciency, easy installation and maintenance,
make this unit one of the best values on the market.
High-effi ciency Copeland Scroll Compressor with a Factory-
installed Sound Blanket. Fewer compressor parts mean less
wear and tear to give your unit longer life. This compressor is
hermetically sealed and features safeguards to protect it from
excessive temperatures, pressure and abnormal electrical
currents. In addition, an energy-saving design reduces internal
resistance and friction and increases operating effi ciency.
Internal parts are spring isolated, and the entire compressor is
mounted on rubber cushions to help absorb vibrations. A heavygauge sound blanket is factory installed to further reduce sound.
Effi ciency and Performance. Simplicity of design and
construction make this unit economical to operate. The
balance of economy and effi ciency makes RHF units ideal for
replacement or new construction. The RHF line delivers SEERs up
to 15 and Heating Season Performances (HSPF) up to 8.5 when
paired with high-effi ciency Amana® brand blower coils, which
can help reduce your cooling and heating costs.
System Protection. Compressor internal overload, high-pressure
switch, and a pressure-relief valve protects the compressor
and other components from damage. A low-pressure cutoff
switch has been added on the suction line to detect a loss of
refrigerant charge. A protective time delay works to prevent
short cycling. A 5-minute delay occurs whenever the power
supply or the indoor thermostat’s signal is interrupted.
Factory-installed Bi-Flow Liquid Line Filter Drier. Standard
protection adds to reliability by helping to keep refrigerant clean
and dry. Clean and dry refrigerant ensures longer life for the
compressor and expansion devices.
Quiet Condenser Fan with Vertical Air Discharge. Quiet, effi cient
fan and motor reduce operating sounds and large blades move
high volumes of air with lower power requirement. Draw through
air fl ow directs operating sound and hot air away from neighbors,
shrubs and buildings for increased installation versatility.
Effi cient Cubed Coil. This space-saving design provides more
active square feet of cooling surface for increased cooling
effi ciency. The compact cubed coil forms the body of the unit.
The unit's compact footprint allows for versatile applications.
Matched Indoor Blower Coils and A-Coils. These coils, in
combination with Amana® brand systems, make for optimum
operating performance and effi ciency. Plastic drain pans used
on the indoor section are threaded for easy attachment of drain
lines. All coils are fully leak tested before leaving the factory.
Service Valves. Solid brass service valves and gauge port are
angled at 30° with enough clearance to easily and quickly
service unit. The service panel swings open at the corner for
effective service from 2 directions. Inside, a pre-wired control
panel speeds installation. Minimal quantity of numbered and
color-coded wires to assure fast fi eld wiring. Compressor and
tubing access from side and top give plenty of internal room for
installation and removal of parts.
Cabinet and Construction. The high-quality sheet metal cabinet
has a long-lasting, corrosion-resistant painted fi nish. A premium
coil grille adds rigidity to better protect the unit as well as
improving appearance. When properly anchored, meets
the 2001 Florida Building Code unit integrity requirements for
hurricane-type winds.
*Unit is charged with refrigerant for 15' of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge
Procedure.
** Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
*Unit is charged with refrigerant for 15' of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge
Procedure.
** Installer will need to supply ⅞” to 1⅛” adapters for suction line connections.
Dimensions
Square BaseHeight
RHF24C2C29½”29½”
RHF30C2C29½”29½”
RHF36C2C35⅝”33½”
RHF42C2C35⅝”33½”
RHF48C2C35⅝”33½”
4
www.amana-hac.com
Page 5
Cooling Specifi cations
Specifi cation Sheet
RHF24C2* / BBA24A2A + CHA30TCC
Conditions: 80° ID DB, 67° ID WB @ 800 CFM
Outdoor
Temp. °F
75°26,40018,4807,9201,790
80°26,05018,4967,5551,845
85°25,70018,5047,1961,900
90°25,40018,5426,8581,950
95°25,10018,5746,5262,000
100°24,45018,4605,9902,040
105°23,80018,3265,4742,410
110°22,95017,6725,2792,120
115°22,10017,0175,0832,160
95°23,30018,4074,8931,920
Total BTUH
TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
Sensible
BTUH
Latent BTUH Total Watts
RHF30C2* / BBA36A2A + CHA36TCC
Conditions: 80° ID DB, 67° ID WB @ 1,050 CFM
Outdoor
Temp. °F
75°30,50020,43510,0652,160
80°30,10020,4689,6322,225
85°29,70020,4939,2072,290
90°29,35020,5458,8052,350
95°29,00020,5908,4102,410
100°28,30020,5187,7832,460
105°27,60020,4247,1762,950
110°26,55019,6476,9032,550
115°25,50018,8706,6302,590
95°26,90020,4446,4562,320
Total BTUH
TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
Sensible
BTUH
Latent BTUH Total Watts
RHF36C2* / BBA48A2A + CHA42TCC
Conditions: 80° ID DB, 67° ID WB @ 1,200 CFM
Outdoor
Temp. °F
75°38,40025,72812,6722,590
80°37,95025,80612,1442,670
85°37,50025,87511,6252,750
90°37,05025,93511,1152,815
95°36,60025,98610,6142,880
100°35,70025,8839,8182,940
105°34,80025,7529,0483,600
110°33,50024,7908,7103,050
115°32,20023,8288,3723,100
95°33,90025,7648,1362,270
Total BTUH
TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
Sensible
BTUH
Latent BTUH Total Watts
RHF42C2* / BBA60A2A + CHA60TCC
Conditions: 80° ID DB, 67° ID WB @ 1,400 CFM
Outdoor
Temp. °F
75°43,60030,08413,5162,970
80°43,05030,13512,9153,060
85°42,50030,17512,3253,150
90°42,00030,24011,7603,230
95°41,50030,29511,2053,310
100°40,45030,13510,3153,375
105°39,40029,9449,4564,200
110°37,95028,8429,1083,500
115°36,50027,7408,7603,560
95°18,20014,3783,8221,460
Total BTUH
TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
Sensible
BTUH
Latent BTUH Total Watts
RHF48C2* / BBA60A2A + CHA60TCC
Conditions: 80° ID DB, 67° ID WB @ 1,600 CFM
Outdoor
Temp. °F
75°50,00034,00016,0003,480
80°49,40034,08615,3143,585
85°48,80034,16014,6403,690
90°48,20034,22213,9783,785
95°47,60034,27213,3283,880
100°46,40034,10412,2963,960
105°45,20033,90011,3005,040
110°43,55032,66310,8884,105
115°41,90031,42510,4754,170
95°38,50030,0308,4703,180
Total BTUH
TVA Conditions @ 95° OD DB, 75° ID DB, 63° ID WB
Sensible
BTUH
Latent BTUH Total Watts
www.amana-hac.com
5
Page 6
Specifi cation Sheet
Heating Specifi cations
RHF24C2* / CHA30TCC / BBA24A2A
Conditions: 800 CFM Indoor Air @ 70° db
Basic Unit Without
Outdoor
Ambient
°F.
6529,5004.1645,90062,30078,700N/A
6027,9004.0244,30060,70077,100N/A
5526,3003.8642,70059,10075,500N/A
5024,5003.6940,90057,30073,700N/A
4522,7003.4939,10055,50071,900N/A
4021,1003.3137,50053,90070,300N/A
3519,5003.1235,90052,30068,700N/A
3018,1002.8634,50050,90067,300N/A
2516,7002.7033,10049,50065,900N/A
2015,4002.5531,80048,20064,600N/A
1514,5002.3730,90047,30063,700N/A
1012,5002.1928,90045,30061,700N/A
511,1001.9927,50043,90060,300N/A
09,7001.7826,10042,50058,900N/A
-58,3001.5624,70041,10057,500N/A
-106,8001.3123,20039,60056,000N/A
Auxiliary Heat
Capacity
Btuh
C.O.P.4.8 kW9.6 kW 14.4 kW
Capacity of Unit
With Auxiliary Heat
19.2, 24
& 28.8
kW
RHF30C2* / CHA36TCC / BBA36A2A
Conditions: 000 CFM Indoor Air @ 70° db
Basic Unit Without
Outdoor
Ambient
°F.
6537,0004.2653,40069,800 86,200N/A
6035,0004.1251,400 67,80084,200N/A
5532,9003.9549,300 65,70082,100N/A
5030,8003.7747,200 63,60080,000N/A
4528,5003.5744,900 61,30077,700N/A
4026,5003.3842,900 59,30075,700N/A
3524,4003.1940,800 57,20073,600N/A
3022,7002.6439,100 55,50071,900N/A
2520,9002.5037,300 53,70070,100N/A
2019,3002.3635,700 52,10068,500N/A
1517,5002.2033,900 50,30066,700N/A
1015,7002.0232,100 48,50064,900N/A
-510,4008.5026,800 43,20059,600N/A
-108,5001.2224,900 41,30057,700N/A
Auxiliary Heat
Capacity
Btuh
513,9001.8430,300 46,70063,100N/A
012,2001.6528,600 45,00061,400N/A
C.O.P.4.8 kW9.6 kW 14.4 kW
Capacity of Unit
With Auxiliary Heat
19.2,
24 &
28.8 kW
RHF36C2* / CHA42TCC / BBA48A2A
Conditions: 1,200 CFM Indoor Air @ 70° db
Basic Unit
Outdoor
Ambient
°F.
6544,7004.0661,100 77,500 93,900 110,300 N/A
6042,3003.9258,700 75,100 91,500 107,900 N/A
5539,8003.7656,200 72,600 89,000 105,400 N/A
5037,2003.5953,600 70,000 86,400 102,800 N/A
4534,5003.3950,900 67,300 83,700 100,100 N/A
4032,0003.2148,400 64,800 81,200 97,600N/A
3529,5003.0345,900 62,300 78,700 95,100N/A
3028,3002.8844,700 61,100 77,500 93,900N/A
2526,1002.7242,500 58,900 75,300 91,700N/A
2024,0002.5640,400 56,800 73,200 74,840N/A
1521,9002.3838,300 54,700 71,100 87,500N/A
1019,6002.1936,000 52,400 68,800 85,200N/A
517,4001.9933,800 50,200 66,600 83,000N/A
015,2001.7831,600 48,000 64,400 80,800N/A
-512,9001.5629,300 45,700 62,100 78,500N/A
-1010,6001.3127,000 43,400 59,800 76,200N/A
Without
Auxiliary Heat
Capacity
C.O.P. 4.8 kW 9.6 kW
Btuh
6
Capacity of Unit
With Auxiliary Heat
14.4 kW19.2
kW
www.amana-hac.com
24 &
28.8
kW
RHF42C2* / CHA60TCC / BBA60A2A
Conditions: 1,400 CFM Indoor Air @ 70° db
Basic Unit
Outdoor
Ambient
°F.
6551,800 4.3568,200 84,600 101,000 117,400 N/A
6049,000 4.2065,400 81,800 98,200 114,600 N/A
5546,100 4.0362,500 78,900 95,300 111,700 N/A
5043,100 3.8559,500 75,900 92,300 108,700 N/A
4539,900 3.6356,300 72,700 89,100 105,500 N/A
4037,100 3.4453,500 69,900 86,300 102,700 N/A
3534,200 3.2550,600 67,000 83,400 99,800 N/A
3030,900 3.0447,300 63,700 80,100 96,500 N/A
2528,600 2.8745,000 61,400 77,800 94,200 N/A
2026,300 2.7042,700 59,100 75,500 77,140 N/A
1523,900 2.5140,300 56,700 73,100 89,500 N/A
1021,500 2.3137,900 54,300 70,700 87,100 N/A
519,000 2.1035,400 51,800 68,200 84,600 N/A
016,600 1.8833,000 49,400 65,800 82,200 N/A
-514,2001.64 30,600 47,000 63,400 79,800N/A
-1011,600 1.3828,000 44,400 60,800 77,200 N/A
Without
Auxiliary Heat
Capacity
C.O.P. 4.8 kW 9.6 kW 14.4 kW19.2 kW
Btuh
Capacity of Unit
With Auxiliary Heat
28.8 kW
24 &
Page 7
Heating Specifi cations (cont.)
RHF48C2* / CHA60TCC / BBA60A2A
Conditions: 1,600 CFM Indoor Air @ 70° db