Always refer to the wire diagram(s) included with the unit
for most current version.
Warranty
Transportation Damage and Claims ............. Back Cover
Limited Warranty .......................................... Back Cover
DELIVERY
UNPACKING
This Alto-Shaam appliance has been
thoroughly tested and inspected to insure only
the highest quality unit is provided. Upon
receipt, check for any possible shipping damage
and report it at once to the delivering carrier.
See Transportation Damage and Claims section
located in this manual.
This appliance, complete with unattached
items and accessories, may have been delivered
in one or more packages. Check to ensure that all
standard items and options have been received
with each model as ordered.
Save all the information and instructions
packed with the appliance. Complete and return
the warranty card to the factory as soon as possible
to assure prompt service in the event of a warranty
parts and labor claim.
This manual must be read and understood by
all people using or installing the equipment model.
Contact the Alto-Shaam service department if
you have any questions concerning installation,
operation, or maintenance.
NOTE: All claims for warranty must include the
full model number and serial number of
the unit.
1. Carefully remove the
appliance from the
carton or crate.
®
NOTE: Do not discard the
carton and other
packaging material
until you have
inspected the unit
for hidden damage
and tested it for
proper operation.
2. Read all instructions in this manual carefully
before initiating the installation of this appliance.
DO NOT DISCARD THIS MANUAL.
This manual is considered to be part of the
appliance and is to be provided to the owner
or manager of the business or to the person
responsible for training operators. Additional
manuals are available from the Alto-Shaam
service department.
3. Remove all protective plastic film, packaging
materials, and accessories from the appliance
before connecting electrical power. Store any
accessories in a convenient place for future use.
®
Q U I C K CH I L LE R • IN S T AL L A TI O N /O P E RA T I O N/ S E RV I C E M AN U A L • 1.
NOTE
SAFETY PROCEDURES
AND PRECAUTIONS
Knowledge of proper procedures is essential to the
safe operation of electrically and/or gas energized
equipment. In accordance with generally accepted
product safety labeling guidelines for potential
hazards, the following signal words and symbols
may be used throughout this manual.
DANGER
Used to indicate the presence of
a hazard that WILL cause severe
personal injury, death, or substantial
property damage if the warning
included with this symbol is ignored.
WARNING
Used to indicate the presence of
a hazard that CAN cause personal
injury, possible death, or major
property damage if the warning
included with this symbol is ignored.
1. This appliance is intended to chill or freeze
foods for the purpose of human consumption.
No other use for this appliance is authorized
or recommended.
2. This appliance is intended for use in commercial
establishments where all operators are
familiar with the purpose, limitations, and
associated hazards of this appliance. Operating
instructions and warnings must be read and
understood by all operators and users.
3. Any troubleshooting guides, component views,
and parts lists included in this manual are for
general reference only and are intended for use
by qualified technical personnel.
4. This manual should be considered a permanent
part of this appliance. This manual and all
supplied instructions, diagrams, schematics,
parts lists, notices, and labels must remain with
the appliance if the item is sold or moved to
another location.
CAUTION
Used to indicate the presence of a
hazard that can or will cause minor or
moderate personal injury or property
damage if the warning included with
this symbol is ignored.
CAUTION
Used to indicate the presence of a hazard that
can or will cause minor personal injury, property
damage, or a potential unsafe practice if the
warning included with this symbol is ignored.
NOTE: Used to notify personnel of
installation, operation, or
maintenance information that is
important but not hazard related.
For equipment delivered for use
in any location regulated by the
following directive:
DO NOT DISPOSE OF ELECTRICAL
OR ELECTRONIC EQUIPMENT WITH
OTHER MUNICIPAL WASTE.
Q U I C K CH I L LE R • IN S T AL L A TI O N /O P E RA T I O N/ S E RV I C E M AN U A L • 2.
INSTALLATION
DANGER
IMPROPER INSTALLATION,
ALTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH,
OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
Position the Quickchiller
to allow sufficient air
ventilation through the
condensing unit(s). The
rear of unit should be no
closer than 6" (152mm)
to any wall or structure.
Avoid installing the
chiller immediately
adjacent to fryers,
charbroilers, or any other
equipment producing
grease laden air; heat
producing equipment
such as ovens and
ranges; and steam discharging equipment such
as steamer ovens and kettles. Do not locate the
Quickchiller in direct sunlight.
Allow sufficient front clearance for serviceability
and for easy maneuvering of food trolleys in and
out of the cabinet.
INSTALLATION
Prior to moving the Quickchiller to the installation
site, check the dimensions of doors, passageways, and
ceiling heights in the areas through which the cabinet
must be moved. Also check the turning radius if the
cabinet must be moved around an existing structure.
The use of a fork lift or pallet lift truck is required for
moving and leveling most Quickchiller models.
NOTE: In certain instances, it may be necessary
to remove doors and door hardware to
negotiate tight spaces.
®
CAUTION
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
SITE INSTALLATION
CLEARANCE REQUIREMENTS
BACK: 6" (152mm) TOP: 6" (152mm)
SIDES: 4" (102mm) minimum at both sides.
18" (457mm) M iNiMu Mc leara Nc e
fr oM he atp ro duc iN ge qui pM eNt.
INSTALLATION REQUIREMENTS
Unit must NOT be tipped on its side
at any time.
Tipping will cause damage to the unit
and void the warranty.
One (1) Floor Drain: 1/2" (12,7mm) diameter
— Appliance must be installed level.
— The appliance must not be installed in any area
where it may be affected by steam, grease, dripping
water, extreme temperatures, or any other severely
adverse conditions.
In order to maintain standards established by the
National Sanitation Foundation, all counter mounted
equipment must be sealed to the counter with a NSF
listed silicone sealant.
5-Year Limited
Warranty on
self-contained
compressor
Effective from date of
shipment. (e xclu desl abor )
Q U I C K CH I L LE R • IN S T AL L A TI O N /O P E RA T I O N/ S E RV I C E M AN U A L • 3.
SITE INSTALLATION
INSTALLATION
INSTALLATION REQUIREMENTS
The model QC-3 is a counter mounted unit and
must be sealed to the counter with a NSF listed
silicone sealant.
For all other
models, install
the appliance
on a smooth and
level floor surface. Use the adjustable
cabinet legs to level the Quickchiller.
Adjust from front-to-back and from side-to-side
with the use of a spirit level to evenly distribute
the cabinet weight and avoid pulling the cabinet
alignment out of square.
After leveling the cabinet of cart equipped models,
check the height relationship of the roll-in cart
to the cabinet. Adjust the Quickchiller height as
needed to accommodate the cart and to securely
close the Quickchiller door(s).
DOOR SEAL:
Check the door gasket to make certain it is sealing
properly and that the gasket provides an even and
positive seal around the entire door frame.
WATER DRAINAGE
DRAINAGE:
QC-3 QC-20 QC-40
EVAPORATOR PANS: NO INSTALLATION REQUIRED
QC-50 QC-100
ONE (1) FLOOR DRAIN:
1/2" (12,7mm) DIAMETER
A 1/2" I.D. (12,7mm) PVC pipe is furnished with
each QC-50 and QC-100 model. Use PVC glue
to attach the pipe into the drain opening at the
rear of the unit. Insert the PVC pipe into the
drain opening with a 1/4" (6mm) clockwise turn.
Connect the PVC pipe to discharge through an
indirect waste pipe into an open-site drain by
means of a 2" (51mm) air gap. Connection must
be within 10' (3m) of the unit.
NOTE: In the U.S.A., this equipment is to
be installed to comply with the Basic
Plumbing Code of the Building Officials
and Co de Administrators International,
Inc. [BOCA], and the Food Service
Sanitation Manual of the Food & Drug
Administration [FDA].
CAUTION
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
Q U I C K CH I L LE R • IN S T AL L A TI O N /O P E RA T I O N/ S E RV I C E M AN U A L • 4.
drainopening
atrear
INSTALLATION
SITE INSTALLATION
TROLLEY GUIDE INSTALLATION
Trolley Guide Installation
1. Align each guide rail with the holes located under
the cabinet.
2. Loosely fasten each guide rail with a washer, lock washer
and bolt.
3. Push the roll-in cart (trolley) into the Quickchiller, center
the cart right-to-left, and close the door.
4. Slide both guide rails toward the center of the
Quickchiller until they make contact with the roll-in cart.
Lock the guide rails into position by tightening the bolts.
At the front of the Quickchiller, make certain contact
has been made between the Quickchiller and the cart
along the total width of the door to create a complete
seal. When a full seal has been determined, recheck each
connection to make certain it has been fully tightened.
Q U I C K CH I L LE R • IN S T AL L A TI O N /O P E RA T I O N/ S E RV I C E M AN U A L • 5.
SUB TITLE
SITE INSTALLATION
INSTALLATION
TITLE
QC-3
26-1/2" (673mm)
29-3/4" (756mm)
54-3/4" (1391mm)
3"
(76mm)
28" (711mm)
5-1/4" (133mm)
Electrical Connection
29-3/4" (756mm)
28-1/2" (724mm)
14-3/4"
(375mm)
34" (864mm)
WEIGHT
net : 350 lb (159 kg) sh ip : 405 lb (184 kg)
car ton di men si ons: (lxw xh)40" x 34" x 43"
(1016mm x 864mm x 1092mm)
REFRIGERATION
R404a Refrigerant
One (1) 3/4 hp Condensing Unit:
3,810 BTU's per hour at -5°F (-21°C) in the freeze mode
7,260 BTU's per hour at +20°F (-7°C) in the chill mode
Q U I C K CH I L LE R • IN S T AL L A TI O N /O P E RA T I O N/ S E RV I C E M AN U A L • 6.
PRODUCT\PAN CAPACITY
Approximately 36 lb (16 kg) Ma xiM u M
vo luM e Max iMu M: 2 2-1/ 2 q uar ts (28,5 l ite rs)
full-si zepaNs: gastroN orM 1/1:
Three (3) 20" x 12" x 2-1/2" (530 x 325 x 65mm)
capa cityfo ruptothree (3) opti oNalst aiNless steelwir eshel ves
SUB TITLE
SITE INSTALLATION
QC-20
INSTALLATION
51-1/4" (1302mm)
TITLE
49-1/2" (1257mm)
16-1/4"
(413mmm)
20-1/4"
(514mm)
38" (965mm)
36-1/8" (918mm)
34" (864mm)
Evaporator
Pan
WEIGHT
ne t: 601 lb (273 kg)sh ip : 665 lb (302 kg)
ca rt ondim en sions : ( lx wxh)
64" x 45" x 45"
(1626mm x 1143mm x 1143mm)
REFRIGERATION
R404a Refrigerant
One (1) 1 hp Condensing Unit:
fre eze Mode: 4,790 BTU's per hour at -5°F (-21°C)
chi llMode: 8,600 BTU's per hour at +20°F (-7°C)
52-1/2" (1334mm)
Electrical Connection
PRODUCT\PAN CAPACITY
Ma xiM u Mch il liN gca pac ity :
Approximately 72 lb (33 kg)
vo luM e Max iMu M: 4 5 q uar ts (42,6 l ite rs)
full-s ize p ans oN wireshe lves:gastroNo rM 1/1:
Five (5) 20" x 12" x 2-1/2" (530 x 325 x 65mm)
full-s izesheetp aNs :
Ten (10)* 18" x 26" x 1"
capacit yforuptofour (4) addit ioNalstaiNl ess
steelwireshelves a saNoptioN
17"
(431mm)
6" (152mm)
36-1/2" (927mm)
30-1/2" (774mm)
42-1/2" (1079mm)
Q U I C K CH I L LE R • IN S T AL L A TI O N /O P E RA T I O N/ S E RV I C E M AN U A L • 7.
SUB TITLE
SITE INSTALLATION
QC-40
64" (1626mm)
INSTALLATION
TITLE
39-7/8" (1013mm)
38-1/2" (978mm)
1-1/2"
(38mm)
ALTO SHAAM
13-1/2"
(343mm)
64-1/4" (1632mm)
70-1/4" (1784mm)
6"
(152mm)
39-7/8" (1013mm)
35-3/8" (899mm)
WEIGHT
net : 676 lb (307 kg)sh ip :977 lb (443 kg)
car ton di men si ons: (lxw xh)44" x 47" x 79"
(1118mm x 1194mm x 2007mm)
REFRIGERATION
R-404a Refrigerant
One (1) 1-1/2 hp Condensing Unit:
fr ee zeMod e: 7,200 BTU's per hour at -5°F (-21°C)
ch il lM ode : 11,400 BTU's per hour at +20°F (-7°C)
Q U I C K CH I L LE R • IN S T AL L A TI O N /O P E RA T I O N/ S E RV I C E M AN U A L • 8.
PRODUCT\PAN CAPACITY
Approximately 144 lb (65 kg) Max iMu M
vo luM e Max iMu M: 9 0 q uar ts (85 li ter s)
full-si zepaNs: gastroN orM 1/1:
Twelve (12) 20" x 12" x 2-1/2" (530 x 325 x 65mm)
full-si zesheetpa Ns:
Six (6)* 18" x 26" x 1" on wire shelves only
*additi oNalsh elvesrequ ired
TITLE
SUB TITLE
SITE INSTALLATION
INSTALLATION
QC-50QC-50 Remote
(705mm)*
41-5/8" (1057mm)*
* Door opening
30-1/2"
(775mm)
75" (1905mm)
51" (1295mm)
27-3/4"
41-1/8" (1045mm)
35-1/2" (902mm)
20-1/4"
(514mm)
76-1/2" (1943mm)
ADJUSTABLE
8" (203mm)
51" (1295mm)
9"
(229mm)
27-3/4"
(705mm)*
41-5/8" (1057mm)*
* Door opening
65-1/2" 1664mm)
8" (229mm) ADJUSTABLE
WEIGHT
ca bi netco nd enser pa nc art
ne t 557 lb (253 kg) 202 lb (92 kg) 120 lb (54 kg)
sh ip ping 862 lb (391 kg) 302 lb (137 kg) 150 lb (68 kg)
re mo tero ll -in
cr at eddi mensi ons : ( lx wxh)
48" x 55-1 /4" x 7 0-1/4" (1219mm x 1397mm x 1778mm)
48-7/16" (1229mm)
41-1/8"
(1045mm)
35-1/2"
(902mm)
ELECTRICAL CONNECTION
35-3/16" (893mm)
Width: 28-1/8" (714mm)
WEIGHT ( a p p r o x im a t e )
ne t 590 lb (268 kg) 120 lb (54 kg)
sh ip ping 900 lb (408 kg) 150 lb (68 kg)
ca bi net ro ll -inpa nc art
cra ted di men si ons: (lxwxh)
48" x 55-1 /4" x 7 9-1/2" (1219mm x 1403mm x 2248mm)
REFRIGERATION
R404a Refrigerant
One (1) 2-1/4 hp Compressor:
fr ee zeMod e: 9,030 BTU's per hour at -5°F (-21°C)
ch il lM ode : 17,500 BTU's per hour at +20°F (-7°C)
Q U I C K CH I L LE R • IN S T AL L A TI O N /O P E RA T I O N/ S E RV I C E M AN U A L • 9.
PRODUCT\PAN CAPACITY
Ma xi MuMpr od uctc apaci ty -
288 lb (131 kg), 180 quarts (228 liters)
Ma xi MuMch il liNgc ap acity -
Approximately 144 lb (65 kg), 90 qts (114 liters)
ful l-siz ep aNs: ga st roNor M 1/1:
Twenty-four (24) 20" x 12" x 2-1/2" (530 x 325 x 65mm)
ful l-siz es heetp aN s:
Twelve (12)* 18" x 26" x 1"
* onwir es helve so nly. e xt rao pt ional wi re
sh el vesre qu iredf or ma xi mumca pa city
sh ow na bov e.
TITLE
65-1/4" (1657mm) DOOR
75" (1905mm)
SUB TITLE
SITE INSTALLATION
INSTALLATION
QC-100QC-100 Remote
51" (1295mm)
27-3/4"
(705mm)*
58-1/2" (1486mm)*
DOOR NOT
SHOWN FOR
CLARITY
* Door opening
30-1/2"
(775mm)
20-1/4"
(641mm)
93-1/2" (2375mm)
8" (203mm)
ADJUSTABLE
41-1/8" (1045mm)
35-1/2" (902mm)
ELECTRICAL CONNECTION
* Door opening
51" (1295mm)
27-3/4"
(705mm)*
58-1/2" (1486mm)*
DOOR NOT
SHOWN FOR
CLARITY
9"
(229mm)
9" (229mm)
ADJUSTABLE
41-1/8" (1045mm)
83-1/4" (2089mm)
35-1/2"
(902mm)
WEIGHT
ca bi netcon den se rpa nc art
ne t 902 lb (409 kg) 250 lb (113 kg) 120 lb (54 kg)
sh ip ping 1200 (544 kg) 380 lb (172 kg) 161 lb (73 kg)
ca rt ondim en sions : ( lx wxh)
re mo tero ll -in
48" x 55" x 98" (1219mm x 1397mm x 2489mm)
ELECTRICAL CONNECTION
WEIGHT ( a p p r o x im a t e )
cabin et roll-in pa nc art
ne t 1152 lb (523 kg) 120 lb (54 kg)
sh ip ping 1450 lb (658 kg) 161 lb (73 kg)
car ton di men si ons: (lxw xh)
55" x 47" x 99" (1397mm x 1194mm x 2515mm)
REFRIGERATION
One (1) 3-1/2 hp Condensing Unit:
fr ee zeMod e: 20,940 BTU's per hour at -5°F (-21°C)
ch il lM ode : 35,800 BTU's per hour at +20°F (-7°C)
R404a Refrigerant
Q U I C K CH I L LE R • IN S T AL L A TI O N /O P E RA T I O N/ S E RV I C E M AN U A L • 10.
65-11/16" (1668mm)
33-1/4"
(714mm)
PRODUCT\PAN CAPACITY
Ma xi MuMpr od uctc apaci ty -
Approximately 480 lb (218 kg), 300 quarts (380 liters)
Ma xi MuMch il liNgc ap acity -
Approximately 240 lb (109 kg), 150 qts (190 liters)
ful l-siz ep aNs: ga st roNor M 1/1:
Forty (40) 20" x 12" x 2-1/2" (530 x 325 x 65mm)
ful l-siz es heetp aN s:
Twenty (20)* 18" x 26" x 1"
* onwir es helve so nly. e xt rao pt ional wi re
sh el vesre qu iredf or ma xi mumca pa city
sh ow na bov e.
Q U I C K CH I L LE R • IN S T AL L A TI O N /O P E RA T I O N/ S E RV I C E M AN U A L • 11.
TITLE
DANGER
SUB TITLE
ELECTRICAL
INSTALLATION
This appliance must be branch circuit protected
with proper ampacities, in accordance with the
wiring diagram. The Quickchiller must be properly
grounded in accordance with the National Electrical
Code and applicable local codes. Wire size for the
main incoming power to the unit must match the
minimum size listed in the specifications applicable
to the specific Quickchiller model. For supply
connections, locate the wire size listed in this manual.
Before operating the chiller, check all cable connections
in the electrical connection area for tightness since
connections can loosen during transport.
NOTE: After electrical connections have been
completed, operate the appliance in any
chilling mode for a period of 15 minutes
and recheck the main power connections
at the terminal block to make certain they
remain tight.
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.
DANGER
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
ELECTRICAL SPECIFICATIONS
vo ltag eph as ecy cl e/hz
SELF-CONTAINED
208-240VAC 1 ph 50/60 Hz
re co MMeNd ed ci rcu it aM per ag e:
re co MMeNd ed wi res iz e:
vo ltag eph as ecy cl e/hz
SELF-CONTAINED
208-240VAC 3 ph 50/60 Hz
re co MMeNd ed ci rcu it aM per ag e:
re co MMeNd ed wi res iz e:
380-415VAC 3 ph 50/60 Hz
re co MMeNd ed ci rcu it aM per ag e:
re co MMeNd ed wi res iz e:
vo ltag eph as ecy cl e/hz
REMOTE COMPRESSOR
(Cabinet Only)
208-240VAC 1 ph 50/60 Hz
re co MMeNd ed ci rcu it aM per ag e:
re co MMeNd ed wi res iz e:
QC-3QC-20QC-40QC-50QC-100
20 amps
12/2 w.g.
QC-3QC-20QC-40QC-50QC-100
No ta vaila bl eNot av ai lableNot av ail ab le
No ta vaila bl eNot av ai lable
QC-3QC-20QC-40QC-50QC-100
No ta vaila bl eNot av ai lableNot av ail ab le
20 amps
12/2 w.g.
n o c o r d a n d p l u g
n o c o r d a n d p l u g
n o c o r d a n d p l u g
30 amps
10/2 w.g.
30 amps
10/2 w.g.
40 amps
8/2 w.g.
20 amps
12/3 w.g.
No ta vaila bl e
20 amps
12/2 w.g.
60 amps
6/2 w.g.
40 amps
8/3 w.g.
30 amps
10/2 w.g.
30 amps
10/2 w.g.
Wire diagrams are located near the top of the unit, close to the compressor or control panel.
Q U I C K CH I L LE R • IN S T AL L A TI O N /O P E RA T I O N/ S E RV I C E M AN U A L • 12.
TITLEOPERATION
OPERATING INTRODUCTION
The Alto-Shaam® Quickchiller™ is a processing refrigeration
system designed to rapidly and uniformly decrease the
temperature of hot foods to either a chilled or frozen state.
This process provides enhanced safety, longer storage life and
better production efficiency.
Rapid reduction in the temperature of hot foods inhibits the
growth of bacteria and provides a safe, five-day chilled food
refrigerated storage period from the time of preparation to the
time of service. Enhanced storage time offers the food service
operation considerable production efficiency. As an example,
a daily menu item can be reduced from daily preparation to a
preparation schedule consisting of two days per week.
The Alto-Shaam Quickchiller can be effectively utilized in
several types of food service programs:
1. TRADITIONAL COOK-SERVE KITCHENS —
Quick chilling can be used to help streamline production in operations where foods are prepared for
immediate service. Preparation of labor intensive entrées can be scheduled for production several
days before service. Chilling foods provides the ability to rethermalize these items at a later date
while maintaining both safety and product quality.
2. MODIFIED COOK-CHILL OPERATIONS—
where a significant portion of food is cooked for immediate service and a smaller portion of more labor
intensive, hot food items are prepared in advance, chilled and reheated when required for service.
3. FULL COOK-CHILL OPERATIONS —
where all hot food production is prepared in advance of service requirements and held in refrigerated
prepared food inventories. Hot food preparation takes place over a five-day production schedule.
The Quickchiller cooling or freezing process
is accomplished with the utilization of large
compressors and fans that are electronically
controlled through the parameters entered by the
operator on the control panel located at the front
of the cabinet. The Quickchiller provides the
operator with the ability to chill food products
to a set cavity temperature by time or by internal
product temperature using one or more food
probes. When the specified chill time has elapsed
or the probe temperature(s) has been reached the
Quickchiller will convert to a holding mode at a
temperature specified for either refrigeration or
frozen product maintenance. The Quickchiller
control maintains a record of the length operating
time used for each current cycle. After the chill
cycle has ended and the unit is maintaining a
holding temperature mode, the chiller control will
initiate an automatic defrost cycle when required.
Q U I C K CH I L LE R • IN S T AL L A TI O N /O P E RA T I O N/ S E RV I C E M AN U A L • 13.