W164 N9221 Wat er Str eet • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-045 0 USA
PHONE: 262.251.3800 • 800.558.8744
US A/C AN ADAFAX: 262.251.7067 • 800.32 9.8744 U.S.A. ONLY
www.alto-shaam.com
®
ASF-60G shown with
asic control and optional
b
automatic basket lifts
G A SF R Y E R
F r y Te c hS e r i e s
ASF-60Gand
ASF-75G
GasFryers
ASF-75G shown with
basic control and optional
automatic basket lifts
P RI N TE D IN U . S .A .
•INSTALLATION
•OPERATION
•MAI NTENANCE
M N - 2 8 6 4 1 • 1 0 / 0 8
D E L I V E R Y
T
his Alto-Shaam appliance has been
t
horoughly tested and inspected to insure only the
highest quality unit is provided. Upon receipt,
check for any possible shipping damage and report
it at once to the delivering carrier. See
Transportation Damage and Claims section
located in this manual.
This appliance, complete with unattached
items and accessories, may have been delivered in
one or more packages. Check to ensure that all
standard items and options have been received
with each model as ordered.
Save all the information and instructions
packed with the appliance. Complete and return
the warranty card to the factory as soon as
possible to assure prompt service in the event of a
warranty parts and labor claim.
This manual must be read and understood by
all people using or installing the equipment
model. Contact the Alto-Shaam service
department if you have any questions concerning
installation, operation, or maintenance.
N O T E :All claims for warranty must include the
full model number and serial number of
the unit.
U N P A C K I N G
1. Carefully remove the
appliance from the
carton or crate.
N O T E : Do not discard the
carton and other
packaging material
until you have
inspected the unit
for hidden damage
and tested it for
proper operation.
2. Read all instructions in this manual carefully
before initiating the installation of this appliance.
DO NOT DISCARD THIS MANUAL.
This manual is considered to be part of the
appliance and is to be provided to the owner or
manager of the business or to the person
responsible for training operators. Additional
manuals are available from the Alto-S haam
service departme nt.
3. Remove all protective plastic film, packaging
materials, and accessories from the appliance
before connecting electrical power. Store any
accessories in a convenient place for future use.
®
®
®
W A R N I N G
In the event of loss of power to the
appliance, turn the “burner control
knobs” to the OFF position. Remove
food product from the unit. If burner
control fails to extinguish the flame,
shut off main gas valve located in
rear of unit.
D A N G E R
BEFORE STARTING THE
APPLIANCE, MAKE CERTAIN
YOU DO NOT DETECT THE
ODOR OF GAS.
IF THE ODOR OF GAS IS DETECTED:
• DO NOT attempt to light any appliance.
• DO NOT touch any electrical switches.
• Extinguish any open flame.
• Use a telephone OUTSIDETHE
PROPERTY & IMMEDIATELY
contact your gas supplier.
• If unable to contact your gas supplier,
contact the fire department.
KEEP THIS MANUAL IN A CONVENIENT L O C AT I O N FOR REFERENCE.
Ga s Fry e r Op e r ati o n & C a re M a nua l • 1
I N S TA L L A T I O N
1. This appliance is intended to cook, hold or
process foods for the purpose of human
consumption. No other use for this appliance is
authorized or recommended.
2. This appliance is intended for use in commercial
establishments where all operators are familiar
with the purpose, limitations, and associated
hazards of this appliance. Operating
instructions and warnings must be read and
understood by all operators and users.
3. Any troubleshooting guides, component views,
and parts lists included in this manual are for
general reference only and are intended for use
by qualified technical personnel.
4. This manual should be considered a permanent
part of this appliance. This manual and all
supplied instructions, diagrams, schematics,
parts lists, notices, and labels must remain with
the appliance if the item is sold or moved to
another location.
N O T E : Used to notify personnel of
installation, operation, or
maintenance information that is
important but not hazard related.
C A U T I O N
Used to indicate the presence of a hazard that can
or will cause minor personal injury, property
damage, or a potential unsafe practice if the
warning included with this symbol is ignored.
C A U T I O N
Used to indicate the presence of a
hazard that can or will cause minor or
moderate personal injury or property
damage if the warning included with
this symbol is ignored.
D A N G E R
Used to indicate the presence of a
hazard that WILL cause severe
personal injury, death, or substantial
property damage if the warning
included with this symbol is ignored.
W A R N I N G
Used to indicate the presence of a
hazard that CAN cause personal injury,
possible death, or major property
damage if the warning included with
this symbol is ignored.
SAFETY PROCEDURES
AND PRECAUTIONS
K
nowledge of proper procedures is essential to the
s
afe operation of electrically and/or gas energized
equipment. In accordance with generally accepted
product safety labeling guidelines for potential
hazards, the following signal words and symbols
may be used throughout this manual.
N O T E
For equipment delivered for use
in any location regulated by the
following directive:
DO NOT DISPOSE OF ELECTRICAL
OR ELECTRONIC EQUIPMENT WITH
OTHER MUNICIPAL WASTE.
Ga s Fry e r Op e r ati o n & C a re M a nua l • 2
I N S TA L L A T I O N
6
0-1/16" (1525mm)
Electrical
Gas
Connection
1/2" NPT
24-13/16" (630mm)
9"
(229mm)
Do
o
r ope
n
s
12
0
°
51-5/16" (1302mm) LIFT UP
45-5/16" (1150mm) LIFT DOWN
37-7/8" (961mm)
60-1/16" (1525mm)
OIL
TROLLEY
12-7/16" (315mm)
3-1/2"
(89mm)
A S F - 7 5 G S P E C I F I C A T I O N S
DI MENS IONS EXTERIOR H x W x D:
45-5/16" x 24-13/16" x 37-7/8"
(1150mm x 630mm x 961mm)
BASKE T DIMEN SIONS (H X W X D)
11-1/2" x 12-3/4" x 21-3/4"
(292mm x 324mm x 552mm)
C A PA CI T Y
SHORTENING/OIL:
73 lb (33 kg) MA XI MU M
LOAD CAPACITY:
13 lb (6 kg)
MA XI MU M
WE IGHT EST.
NE T W EIGHT:360 lb(163 kg)
SHIP WEIGH T:520 lb(236 kg)
CA RTON DIMEN SIONS: H x W x D
57" x 34" x 47"
(1448mm x 864mm x 1194mm)
STA NDAR D A CCES SORI ES
■■
Basket, Half-Size (2 I
Brush Set
■■
■■
■■
Filter, Paper
■■
■■
(O NE 3-BRUSH S ET INCLUDED A S S TANDARD)
AN GL E BR USHBH-28692
SC RU B BR USHBH-28693
ST RA IG HT BRUSHBH-28691
APER FILTE RS IN CLUDED AS STANDARD
(7 P
7 COU NT REF ILL PAC KAGEFI-27791
OUN T RE FILL PACKA GE
100 C
NC LU DE D AS STA NDAR D
)BS-27140
)
FI-27794
O P TI O N S
■■
Basket, Full-Size (
FILTERS
■■
■■
Fry Pot Cover5005136
■■
Mobile Drawer Cover5006073
■■
Strainer/SkimmerCE-27400
■■
■■
Oil Discard HoseHO-27686
48
HI CK EN PIECE CA PACIT Y
C
)
BS-26998
Charcoal/Carbon (3 0 CO UN T PKG.)FI-27648
Reusable Mesh (SINGL E F ILTER)FI-27014
Ga s Fry e r Op e r ati o n & C a re M a nua l • 3
I N S TA L L A T I O N
33-5/8" (854mm)
23-1/4"
(590mm)
47-1
/2
"
(1
206mm
)
6-9/16"
(167mm)
6-3/8"
(162mm) Gas Connection
32-3/8" (822mm)
Electrical Connection
2-7/8"
(72mm)
15
0°
15-3/4"
(400mm)
4
5
-
1
/
8
"
(
1
1
4
6
m
m
)
5
6
-
1
/
8
"
(
1
2
9
8
m
m
)
l
if
t
u
p
A S F - 6 0 G S P E C I F I C A T I O N S
DI MENS IONS E XT ERIOR H x W x D:
45-1/8" x 15-3/4" x 33-5/8"
(1146mm x 400mm x 854mm)
BA SK ET D IMENSIO NS (H X W X D )
5-7/8" x 5-3/16" x 13-13/16"
(149mm x 131mm x 351mm)
CA PACIT Y
SHORTENING/OIL: 62 lb (28 kg)
WE IGHT
NE T WE IG HT:248 lb (113 kg)
SH IP W EI GHT:330 lb (150 kg) ES T
CA RTO N DI ME NSIONS
:39" x 22" x 55" ES T
(991mm x 559mm x 1397mm) EST
MA XI MU M
STA NDAR D ACC ESSO RIES
■■
Basket, Half-Size (2 INCLUDED AS STA NDAR D)BS-27963
Brush Set (O NE 3-BR USH SET INCLUDED AS STA NDAR D)
■■
AN GL E BR USHBH-28692
■■
CR UB B RU SH
S
■■
ST RA IG HT BRUSHBH-28691
BH-28693
O P TI O N S
Fry Pot Cover5007596
■■
■■
Strainer/SkimmerCE-27400
Ga s Fr y er O per a t io n & Ca r e M a nua l • 4
I N S TA L L A T I O N
D A N G E R
I
MPROPER INSTALLATION,
ALTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH
OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.
D A N G E R
AVERTISSEMENT : UNE INSTALLATION,
UN AJUSTEMENT, UNE ALTÉRATION,
UN SERVICE OU UN ENTRETIEN NON
CONFORME AUX NORMES PEUT CAUSER
DES DOMMAGES À LA PROPRIÉTÉ, DES
BLESSURES OU LA MORT.
LIRE ATTENTIVEMENT LES DIRECTIVES
D’OPÉRATION ET D’ENTRETIEN AVANT
DE FAIRE L’INSTALLATION, OU
L’ENTRETIEN DE CET ÉQUIPEMENT.
C A U T I O N
DO NOT USE FORKLIFT FROM
FRONT OR REAR OF UNIT.
USE FORKLIFT FROM SIDE ONLY.
C A U T I O N
METAL PARTS OF THIS EQUIPMENT
BECOME EXTREMELY HOT WHEN IN
OPERATION. TO AVOID BURNS,
ALWAYS USE HAND PROTECTION
WHEN OPERATING THIS APPLIANCE.
S I T E I N S T A L L A T I O N
NOTE: To avoid equipment damage, remove the
Mobile Oil Trolley before moving this
appliance with a forklift or pallet lift.
MINIMUM CLEARANCE REQUIREMENTS
CO M B U STIB L ENON -C OMBU S T IBLE
SUR FA C E SSUR FA C E S
RIG H T SI D E0" (152mm)0"(0mm)
LEF T SID E0" (0mm)0"(0mm)
BAC K6" (152mm)6" (152mm)
FRO N T25" (635mm)
PL US : 6" (152mm) minimum between the element swing in the
extended position and the lower edge of the exhaust hood
and filter media.
ENT RY CL EARA N C E: 30" (762mm)
Ne pas installer à une distance inférirure à celle
ind i quée ce-dessou s d'une parol en matiére
combustible: Côtés 6 pouches, Arriére 6 pouches.
UN CR ATE D
MINIMUM CLEARANCES MUST
REMAIN UNOBSTRUCTED.
DO NOT place insulation or any other
type of materials in clearance areas.
Ga s Fr y er O per a t io n & Ca r e M a nua l • 5
I N S TA L L A T I O N
C A U T I O N
TO PREVENT PERSONAL INJURY,
USE CAUTION WHEN MOVING OR
LEVELING THIS APPLIANCE.
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
S I T E I N S T A L L A T I O N
.It is the responsibility of the installer to verify that this
1
fryer installation is in compliance with the
specifications listed in this manual and with local code
requirements.
2.Hood installation is required.
3.Both cooking and cleaning functions require
unobstructed access. The frypot, control panel, and
front access door must be maintained free from
obstruction. The access door must be accessible for
service and maintenance.
4.Locate the fryer on a firm, level surface ONLY. The
area surrounding the fryer must be kept clear of all
combustible materials.
5.FOR YOUR SAF ETY DO NOT store or use any
flammable liquids or allow flammable vapors in the
vicinity of this fryer or any other appliance.
6.FOR YOUR SAF ETY DO NOT place insulation
or any other type of materials in clearance areas.
7.When properly installed, the electric fryer is designed
for operation adjacent to non-combustible floors and
walls with a 6" clearance at the back. Clearances from
all combustible construction is a minimum of 6"
(152mm) at the back and both sides. Concrete, tile,
terrazzo, or metal surfaces are recommended. Metal
over a combustible material may not meet code for
non-combustible surfaces. Verify site selection with
local codes for specific requirements.
Doit être utilisé seulement sur des planchers non
inflammables.
8.Adequate means must be provided to limit the
movement of this appliance. A restraining device is
required for field installation.
9.DO NOT install this fryer in any area where it may be
affected by any adverse conditions such as steam or
ripping water, etc. DO NOT install the fryer over a
d
drain.
10.ASF-75 G L EVELIN G: Make certain the
ryer is positioned firmly on all four
f
supporting casters. Level fryer front-toback and side-to-side by loosening the jam
nut on each leveling caster and turning the
caster. Restraining ties can be used for
stabilization if necessary.
LOCKING SCREW
twist the caster to the unlocked position.
To relock, repeat this action and twist the
caster until the pin resets back into the
locked position.
11.AS F-60G LEVELI N G: Make
certain the fryer is positioned firmly
on all four supporting casters. Level
fryer front-to-back and side-to-side
by holding lower collar (#2) while
twisting upper collar (#1).
Restraining ties can be used for
stabilization if necessary. Use an allen
wrench (#3) to lock caster in position.
BURN WARNING: Make certain the
fryer is stabilized before operation to
prevent any movement or tipping and
the possibility of severe burns caused
by hot, splashing shortening or oil.
Locking casters are located at the
front of the fryer. To unlock the
front casters, pull the locking pin
away from the caster assembly and
1
2
3
Fire may be the result of improper
installation. Carefully read and follow
all installation instructions located in
this manual.
Ga s Fr y er O per a t io n & Ca r e M a nua l • 6
I N S TA L L A T I O N
D A N G E R
Installation, air adjustment and/or
service work must be in accordance
with all local codes and must be
performed by a certified service
technician qualified to work on
gas appliances.
C A U T I O N
To prevent malfunction or cause
negative back draft, DO NOT obstruct
exhaust flues or attach any flue
extension that will impede proper
burner operation.
V E N T I L A T I O N
An adequate ventilation system is required for commercial cooking equipment. Information may be obtained by writing
to the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. When writing refer to NFPA No. 96.
1.A single ASF-75G or ASF-60G auto-lift gas fryer
requires a minimum of 120 CFM make-up air for
natural gas and 48 CFM for propane gas. Kitchen
ventilation must be of sufficient capacity to prevent a
negative-pressure condition. DO
restrict ventilation nor the air flow required to support
combustion.
2.DO
NO T obstruct the flow of the exhaust flue at the
top rear of the fryer. It is especially critical that gas
supply piping and electrical support cord and/or
receptacle be routed away from the path of the hot
combustion fumes.
NO T obstruct or
3.This fryer cannot be direct vented.
4.Install the fryer under a ventilation hood meeting all
applicable code requirements. Combustion fumes
must be vented in accordance with local, state, or
national codes.
FAILURE TO VENT THIS FRYER PROPERLY MAY BE
HAZARDOUS TO THE HEALTH OF THE OPERATOR.
Equipment damage and operational problems may
also be the consequence of improper venting. Any
damages sustained by a failure to properly vent this
fryer are not covered under warranty.
Ven t i l at i ng h oo d s a nd e xh a us t sy st e m s s ha l l b e
permi tted to b e u s e d t o v e n t a p p l i a nces installed in
comme rcial applic ations.
Whe re au t o matic a lly op e rated a pplian c es ar e vent e d
thro ugh a v entilating ho od or e xhaust system e qui ppe d with
a damper or with a power means of e xha ust, p ro vis ion s
shall be mad e to allow the flo w of gas to the mai n burner s
only wh en the damper is open to a pos iti on to properly v ent
the applia nce and when the power me ans of exha ust is in
operation.
MA SSA CHU SETT S ON LY
IN AC CORD ANC E WIT H NFPA 54 C OMM ONW EALTH OF
.
Ga s Fr y er O per a t io n & Ca r e M a nua l • 7
I N S TA L L A T I O N
D A N G E R
CONNECTING TO THE WRONG GAS
SUPPLY COULD RESULT IN FIRE OR
AN EXPLOSION CAUSING SEVERE
INJURY AND PROPERTY DAMAGE.
W A R N I N G
TO AVOID SERIOUS PERSONAL
INJURY, installation of this appliance
must conform to local, state, and
national codes; the current edition of
the American National Standard
Z223.1, National Fuel Gas Code, and
all local municipal building codes. In
Canada, installation must be in
accordance with Standard CAN/CSA
B 149.1 and Installation Codes - Gas
Burning Appliances, and local codes.
G A S S P E C I F I C A T I O N S
The Alto-Shaam open gas fryer has been set to operate
with either natural gas or propane as indicated on the
fryer identification name plate.
The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2
psi. The appliance must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psi.
NOTE: Customer/installer must provide manual gas shut-
off valve in accordance with local code
requirements.
GAS P RES S UR E CHA RT
The fryer has been factory adjusted according to
the gas type specified on the fryer identification
name plate.
GAS FRYER TECHNICAL SPECIFICATIONS
G A S SP E C I FI C AT IO N S
■■
NATURAL G AS
120,000 BTU/hr. I NPUT120,000 BTU/hr. I NPUT
I N STA L LAT I O N RE Q U I RE M EN T S
GA S CO NN ECTION: 1/2" NPT
CH EC K PL UMBING CO DE S FO R PR OPER SUPPLY L INE SI ZING TO
ATTAIN MIN IM UM B URNER MANIF OL D PR ESSURE SHOW N
NATUR AL GAS: 5.0" W.C.
PR OPANE GAS : 10.0" W.C.
MA XI MU M INLET PRE SS UR E: 14" W.C.
■■
PR OPAN E GAS
:
NO TE: If a flexible gas line is used, it must be AGA
approved, commercial type and at least 3/4" I.D.
HO OD INSTALLATIO N IS REQUIRED
Ga s Fr y er O per a t io n & Ca r e M a nua l • 8
N at u r al G a s
Min. Connected Pressure5.0" W.C.1.2 kPa
Max. Connected Pressure14.0" W.C.3.5 kPa
Gas Consumption120 CFM
Gross Thermal Output120,000 Btu/hr
Pro pan e G as
Min. Connected Pressure10.0" W.C.2.5 kPa
Max. Connected Pressure14.0" W.C.3.5 kPa
Gas Consumption48 CFM
Gross Thermal Output120,000 Btu/hr
Use an approved gas
I
NCORRECTCORRECT
A
B
C
D
E
F
G
H
D A N G E R
I
nstallation, air adjustment and/or
service work must be in accordance
with all local codes and must be
performed by a certified service
technician qualified to work on
gas appliances.
D A N G E R
NEVER USE AN OPEN
FL AME TO LEAK T EST.
pipe sealant at all
external threaded
connections, gas
piping used on gas
connections must
avoid sharp bends
that may restrict the
flow of gas to the
appliance. If the
connected pressure exceeds 14.0" W.C. (3.5 kPa), a
step-down regulator is required to be supplied by the
owner/operator.
Clo s e t h e i n divi d ual manua l sh u t-off val v e t o
iso l ate the frye r from the gas supply piping system
during any pressure testing at test pressures equal to
or less than
individual shut-off valve mus t be dis c onne c te d
1
/
psig. (3.4 kPa). The fryer and
2
from the gas supply piping system during
any pressure testing at pressures in
excess of 1/2 psig. (3,4 kPa).
I N S TA L L A T I O N
G A S C O N N E C T I O N
In the U.S.A. , installation must conform to local
codes or, in the absence of local cod es, with the
current edition of the Nati onal Fuel Gas Code,
NFPA-54 and ANSI Z83.11a CSA 1.8a 2004 (or
latest editio n). In Canada, installation must be in
accordanc e with local codes, CAN/CGA-B149.1,
Ins tallatio n f or Natural Gas Burni n g Applianc es
and E q uipment (latest edition) o r CAN/CGA-B149.2 Instal l ation for Propane Burning
App liances and Equipm e nt (latest edition ).
The in l et s upply lin e mu s t b e pro p erly siz e d to
acc o mmod a te a ll i ndivi du al a ppli a nces
sim u ltan e ously use d on the sam e li n e b u t m u st
nev e r b e sm a ller tha n 3/ 4 " I . D.
LEAK TESTING
Installation requires gas leak testing on all gas
piping and fittings. Use an approved electronic leak
device or a soap and water solution at all gas
connections. If bubbling appears when using a soap
and water solution, the connection must be refitted.
Never use an open flame to leak test.
GAS INTAKE
A-G Installation elbow
B Wall Valve
C-D Three-piece union fitting
(minimum 1 per installation)
E-F End connector for the flexible tube
H Marking line
Ga s Fr y er O per a t io n & Ca r e M a nua l • 9
I N S TA L L A T I O N
W A R N I N G
RISK OF ELECTRIC S HOCK.
Appliance must be secured
to building structure.
R E S T R A I N T R E Q U I R E M E N T S - M O B I L E E Q U I P M E N T
The fryer must be supplied with a connector that
complies with all state and local installation codes.
Any appliance that is not furnished with a power
supply cord but that includes a set of casters must be
tethered. Adequate means must be provided to limit
the movement of this appliance without depending
on or transmitting stress to the electrical conduit.
The following requirements apply:
1. Casters must be a maximum height of 4-inches (102mm).
Such mobile appliances must be installed with
2.
the use of a flexible connector secured to the
building structure.
A mounting connector for a restraining device is
located on the lower back flange of the appliance
chassis, approximately 7-inches (178mm) from the
floor. A flexible connector is not supplied by nor is it
available from the factory.
Ga s Fr y er O per a t io n & Ca r e M a nua l • 1 0
An electrical wiring diagram is located in the front access
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
door of the fryer. The fryer must be installed by a
qualified electrician. This appliance must be branch circuit
protected with proper ampacities, in accordance with the
wiring diagram located in the fryer. The fryer must be
properly grounded in accordance with the National
Electrical Code and applicable local codes. A means to
disconnect the unit must be incorporated into the fixed
wiring in accordance with wiring codes.
I N S TA L L A T I O N
E L E C T R I C A L R E Q U I R E M E N T S
locate the wire size posted on the label located on the
electrical control box cover, behind the service panel or
elsewhere listed in this manual.
Before operating the fryer, check all cable connections in
the electrical connection area for tightness since
connections can loosen during transport.
230V:
To prevent an electrical shock hazard between the
appliance and other appliances or metal parts in close
vicinity, an equalization-bonding stud is provided. An
equalization bonding lead must be connected to this
stud and the other appliances / metal parts to provide
sufficient protection against potential difference. The
terminal is marked with the following symbol.
Wire size for the main incoming power to the unit must
match the minimum size listed in the specifications
applicable to the specific fryer. For supply connections,
EL ECTR ICAL • ASF- 60G W IT H BASI C C O NTR O L
VOLTAGEPHASE CYCLE/HZ AMPSKW
120 (AG CY )1601.21.5
230 (AG CY )1 50/601.02.3
EL ECTR ICAL • ASF- 60G W IT H DELU X E C O NT R O L
VOLTAGEPHASE CYCLE/HZ AMPSKW
120 (AG CY )1601.21.5
230150/601.02.3
N EM A 5-15P
15A-125V
C EE 7 /7
220-230V
N EM A 5-15P
15A-125V PLUG
C EE 7 /7
220-230V PLUG
PLUG
PLUG
Ga s Fr y er O per a t io n & Ca r e M a nua l • 1 1
EL ECTR ICAL • ASF- 75G W IT H BASI C C O NTR O L
VOLTAGEPHASE CYCLE/ HZ AMPSKW
120 (AG CY )1607.20.864
230 (A GC Y)1 50/604.00.92
EL ECTR ICAL • ASF- 75G W IT H DELU X E C ONT R O L
VOLTAGEPHASE CYCLE/ HZ AMPSKW
120 (AG CY )1607.20.864
230 (A GC Y)1 50/604.00.92
NN EE MM AA
15A-125V Plug
C EE 7 /7
220-230V PLUG
NN EE MM AA
15A-125V Plug
C EE 7 /7
220-230V
5-15P
5-15P
PLUG
O P E R A T I O N
FIRE OR EQUIPMENT DAMAGE CAN RESULT
FROM IMPROPER SHORTENING LEVELS.
THE LEVEL OF SHORTENING MUST ALWAYS
BE ABOVE THE HEATING ELEMENTS WHEN
THE FRYER IS OPERATING.
THE REQUIRED SHORTENING LEVEL
MUST ALWAYS BE ABOVE THE
MINIMUM HOT OIL FILL LINE.
MAXIMUM HOT OIL FILL LINE
M
INIMUM
H
OT OIL FILL LINE
TOP BEND INSIDE
OIL KETTLE
FR
O
NT
OF KETTL
E
COLD OIL or SHORTENING EXPANDS AS
THE TEMPERATURE INCREASES. TO AVOID
INJURY AND EQUIPMENT DAMAGE ALLOW
FOR EXPANSION BY FILLING
1
/2" (13mm)
BELOW THE MAXIMUM HOT OIL FILL LINE.
THE FLASH POINT OF SHORTENING
OCCURS AT A LOWER TEMPERATURE
THE LONGER THE SHORTENING IS
USED. DISCARD ANY SHORTENING
SHOWING SIGNS OF DETERIORATION
TO AVOID SERIOUS BURNS, FIRE AND
PROPERTY DAMAGE.
FLASH
POINT
C A U T I O N
METAL PARTS OF THIS EQUIPMENT
BECOME EXTREMELY HOT WHEN IN
OPERATION. TO AVOID BURNS,
ALWAYS USE HAND PROTECTION
WHEN OPERATING THIS APPLIANCE.
O I L / S H O R T E N I N G R E Q U I R E M E N T S
IL/SHORTENING REQUIREMENTS
O
The ASF-75G requires 73-pounds (33 kg) of oil or
shortening in the frypot and the ASF-60G requires
62-pounds (28 kg) of oil or shortening. Use only
quality, high-grade oil/shortening in the fryer. The high
moisture content of many lower grade shortening will
result in excessive foaming and boil over. The cold
oil/shortening level requirement for the fryer is indicated
below.
NOTE: ALWAYS maintain the proper level of
shortening by adding fresh oil/shortening
to the frypot whenever needed.
Check the quality of the oil/shortening in the frypot on a
aily basis for signs of deterioration. Use an approved test
d
kit. Signs of shortening deterioration include excessive
boiling, smoking, foaming, bad taste, and rancid odor.
Discard any shortening before it degrades to the point of
affecting product quality. Always filter the oil on a regular
basis and keep the frypot clean.
Remove ice crystals and ensure that food is dry before
frying. Excessive water and ice can cause oil to splatter or
overflow. Do not over fill the basket. Food needs to be
surrounded by oil for best frying results.
BASIC CONTROL
Maximum shortening life is achieved by turning the fryer
stations off when not in use. In multiple-station units, heat
only the component fryers necessary to meet cooking
needs.
OIL /S HORT E NING
LEV E L S
FAILURE TO PLACE SOLID SHORTENING
DIRECTLY ON THE BOTTOM OF THE
FRYPOT C AN C AUS E SERIOUS
ENSURE THERE IS NO WATER IN THE FRYPOT
BEFORE FILLING WITH OIL/SHORTENING.
WHEN COOKING COMPOUNDS ARE HEATED
TO COOKING TEMPERATURE, WATER IN THE
FRYPOT WILL CAUSE OIL TO SPLATTER AND
MAY BE A BURN HAZARD.
E Q UI P M E NT D A MA G E .
DELUXE CONTROL
Maximum shortening life is achieved by lowering the
temperature of the fryer to 250°F (121°C) whenever the
fryer is not being used. This is an automatic program
function through the control program
designation of “IdleMode.” The factory
default is set at a period of 30 minutes of
non use before triggering a temperature
decrease, however; this time period can be adjusted
between “0” and “60” minutes. (
CONTROL)
Ga s Fr y er O per a t io n & Ca r e M a nua l • 1 2
3 0 : 0 0
Id leMo de
SEE PROGRAMMING THE
O P E R A T I O N
D A N G E R
BEFORE STARTING THE
APPLIANCE, MAKE CERTAIN
YOU DO NOT DETECT THE
ODOR OF GAS.
IF THE ODOR OF GAS IS DETECTED:
• DO NOT attempt to light any appliance.
• DO NOT touch any electrical switches.
• Extinguish any open flame.
• Use a telephone OUTSIDE THE
PROPERTY & IMMEDIATELY
contact your gas supplier.
• If unable to contact your gas supplier,
contact the fire department.
B A S I C C O N T R O L S T A R T U P & G E N E R A L O P E R A T I O N
NOTE: Because each fryer station is controlled
eparately, the following procedures
s
must be followed for every component
fryer in multiple-station units.
3.Open front access door and ensure drain valve is
closed. The handle should be rotated clockwise
until it stops.
4.Fill frypot with frying compound as indicated.
(S EE ILLUSTRAT IO N O N T HE OI L/SHORTE NI NG REQUIREMENTS
PAGE
)
5.The Master Power Switch is located behind the
front access door. Turn Master Power Switch
“ O N . ”
NOTE: Perform an initial Boil-Out to clean and
sanitize the fryer station before
operating. (See page 15.)
1.Service is to be performed by an authorized
Alto-Shaam service agent.
2.Ensure all local electrical codes, fire codes, and
all other requirements such as hood installation
have been met in the process of installation.
A S F - 6 0 G
KETTLE DRAIN
CLOSED
SELECTOR
OPEN
OIL
HI-LIMIT
RESET
ELEMENT
HI-LIMIT
ALARM
ELEMENT
HI-LIMIT
RESET
MASTER
POWER
SWITCH
Ga s Fr y er O per a t io n & Ca r e M a nua l • 1 3
6.Press E L E M E N T HI RE SE T button.
7.The L E D display on the basic control panel will
indicate “ - A S - ” , the software version, and then
“ C Y ” .
8.When the fryer has reached 135°F, the melt cycle
is complete and the L E D display on the control
panel will indicate “ HE At ”.
9.When the fryer displays the set-point
temperature, product can be fried.
10. More detailed operating guidelines along with
information on programming are located within
this manual.
11. To shutdown the fryer, turn the Master Power
Switch located behind the front access door to
the “ O F F ” position.
NOT E:FORYOUR PROT E C TION The fryer station is
furnished with a hi-limit safety shutoff that
will disengage the control if the fryin g
compound temperature in the frypot would
ever exceed 415°F (213°C). The L E D will
display “ H i ” , the heat will shut off, the
timer will be cancelled, and a constant alarm
will sound. In this event, allow the frying
compound temperature to drop below 415°F
(213°C). Open the front access door and
press the OIL HI -LIMIT RESET button for
a period of 3-seconds to restart the control.
O P E R A T I O N
D A N G E R
BEFORE STARTING THE
APPLIANCE, MAKE CERTAIN
YOU DO NOT DETECT THE
ODOR OF GAS.
IF THE ODOR OF GAS IS DETECTED:
• DO NOT attempt to light any appliance.
• DO NOT touch any electrical switches.
• Extinguish any open flame.
• Use a telephone OUTSIDE THE
PROPERTY & IMMEDIATELY
contact your gas supplier.
• If unable to contact your gas supplier,
contact the fire department.
D E L U X E C O N T R O L S T A R T U P & G E N E R A L O P E R A T I O N
NOTE: Perform an initial Boil-Out to clean and
anitize the fryer before operating. (See
s
page 16.)
1.Service is to be performed by an authorized
Alto-Shaam service agent.
2.Assure all local electrical codes, fire codes, and
all other requirements such as hood installation
have been met in the process of installation.
3.Open front access door and insure drain valve is
in the “ C L O S E D ” position. The handle should
be rotated clockwise until it stops.
4.Fill frypot with frying compound as indicated.
(S EE ILLUSTRAT IO N O N T HE OI L/SHORTE NI NG REQUIREMENTS
AG E
)
P
5.The Master Power Switch is located behind the front
access door. Turn Master Power Switch “ON.”
6.Push the E L E M E N T H I L IM IT reset button.
7.Both “ LE D” displays on the control panel will
indicate “ O F F ” when the Master Power Switch
is initially turned to the “ ON ” position.
11. For fryer “Shu tdown” press the Power Key on
the main control panel to the “ OF F” position.
urn the Master Power Switch located behind the
➧ T
front access door to the “ OF F” position.
NOT E:
F
The fryer is
OR YOUR PROT E C TION
furnished with a hi-limit safety shutoff that
will disengage the control if the oil
temperature in the frypot would ever
exceed 432°F (222°C). In this event, the oil
temperature must be allowed to decrease to
375°F (191°C) before restarting the
appliance. After allowing the oil
temperature to decrease, open the front
access door and press the RES ET BU TTON for
a period of 3-seconds to restart the control.
8.Press and hold the Power “ O N ” Key on the
main control panel for 3 seconds. Both “ LE D”
displays on the control panel will indicate actual
oil temperature or ambient room temperature.
The bottom of alpha/numeric display will
indicate “M ELT-C YCLE.” It is recommended to
allow the fryer to complete the "Melt Cycle"
when using solid shortening; however, if liquid
shortening is used the "Melt Cycle" may be
bypassed by pressing Temperature Key
for 3 seconds.
9.After fryer has reached the factory-set oil
temperature of 350°F (177°C) or the temperature
set by the operator, product can be fried.
10. More detailed operating guidelines along with
information on presets and other options are
located within this manual.
BYPASSING THE "MELT-CYCLE" WHEN
USING SOLID SHORTENING CAN RESULT
IN MAJOR EQUIPMENT DAMAGE AND
WILL VOID ALL WARRANTIES.
Ga s Fr y er O per a t io n & Ca r e M a nua l • 1 4
A S F - 7 5 G W I T H O I L F I LT R A T I O N
OPEN
NOZZLE
KETTLE
SELECTOR
CLOSED
NOZZLE
CONNECTION
PUMP
OIL
HI
-LIMIT
RESET
MASTER
POWER
SWITCH
CONTROL
RESET
IGNITION
ALARM
DRAIN
NOTE: Perform an initial Boil-Out to clean and
anitize the fryer station before
s
operating.
Carbonized deposits along with an accumulation of
oil will eventually build-up on the interior of the
frypot as well as fryer accessories. It is important to
periodically remove these deposits, not only to
maintain fryer efficiency, but also to provide the
highest product quality.
NOTE: Because each fryer station is controlled
separately, the following procedure must
be followed for every component fryer in
multiple-station units.
O P E R A T I O N
B A S I C C O N T R O L B O I L - O U T
. Turn the Master Power Switch located behind the
7
front access door to the “ O F F ” position.
8.Attach the drain pipe and direct boil-out solution
into a heat-resistant container.
9.Open the D R A I N . The handle should be
rotated counterclockwise until it stops.
10. Allow the boil-out solution to completely drain.
Discard boil-out solution.
11. Rotate the drain valve clockwise to the
“CL OSED” position and follow the
manufacturers additional boil-out instructions to
rinse the frypot in order to neutralize boil-out
cleaner residue. Discard rinse solution.
when the actual temperature of the
frypot is less than 230°F (110°C).
1.Close the D R A I N . The handle should be
rotated clockwise until it stops.
2.Fill the fryer to the maximum oil fill line with a
mixture of cold water and fryer boil-out solution.
Carefully follow the manufacturer ’s directions
for mixing the boil-out solution.
3.Turn the Master Power Switch (located within
the front access door) to the “ ON ” position.
4.Push the E L E M E N T H I L IM IT reset button.
5.Wait until the L E D reads “ H E A t ”, then press
the B O I L O U T buttonon the control
panel.
6.When 192°F (89°C) is reached, the L E D will
display “ bO IL ” and that temperature will be
maintained. Using a separate timer, allow the
frypot to boil-out for 10 minutes.
8.Following the boil-out procedure, rinse, and cool
down period, wipe all accessible metal surfaces
in the interior and wipe all interior accessories
with a clean, dry cloth to remove remaining
rinsing solution. Clean and dry the fry baskets
separately.
9.Wipe the exterior of the fryer cabinet with a
degreaser/sanitizer suitable for use on food
contact surfaces. Always follow the
manufacturer's instructions and/or mixing
directions for proper solution strengths.
Wipe exterior stainless steel surfaces with the
grain of the metal and avoid the use of abrasive
pads, steel wool, or metal implements.
TO PR O TEC T T H E P UMP FR O M
PO S SIB L E W AT E R D A MA G E A F TER
TH E B O ILO U T P ROC E DUR E , F I LL
TH E K E TTL E W I TH OIL AN D C Y C LE
TH R OUG H T O R E MOV E A N Y
EX C ESS WAT E R.
DO NOT leave the fryer unattended during the boilout process. The fryer must be continuously
monitored for boil-over conditions, particularly in
high-altitude locations. If boil-over occurs,
immediately turn the Master Power Switch located
behind the front access door to the “OFF” position
and allow the solution to cool. When the solution
has cooled, re-enter the boil-out mode.
Ga s Fr y er O per a t io n & Ca r e M a nua l • 1 5
ENSURE THERE IS NO WATER IN THE FRYPOT
BEFORE FILLI NG WI TH OIL/SHO RTENI NG.
WHEN COOKING COMPOUNDS ARE HEATED
TO COOKING TEMPERATURE, WATER IN THE
FRYPOT WILL CAUSE OIL TO SPLATTER AND
MAY BE A BURN HAZARD.
O P E R A T I O N
M
AXIMUM HOT OIL FILL LINE
M
INIMUM
HOT OIL FILL LINE
TOP BEND INSIDE
OIL KETTLE
FRO
N
T
O
F
KE
TTLE
D E L U X E C O N T R O L B O I L - O U T
NOTE: Perform an initial Boil-Out to clean and
sanitize the fryer before operating..
Carbonized deposits along with an accumulation
of oil will eventually build-up on the interior of the
frypot as well as fryer accessories. It is important to
periodically remove these deposits, not only to
maintain fryer efficiency but also to provide the
highest product quality.
Before entering this program, make certain the frypot is
empty of all oil or shortening. Close the frypot drain.
Carefully follow the manufacturer's mixing directions
and fill the frypot with a mixture of cold water and fryer
boil-out solution.
A S F - 7 5 G W I T H O I L F I LT R A T I O N
OIL
-LIMIT
HI
RESET
CONTROL
RESET
NOZZLE
KETTLE
SELECTOR
OZZLE
N
CONNECTION
1.Open the front access door. With the
Kettle/Nozzle selector in the “K E TTLE”
position, rotate the drain valve clockwise until
rotation stops and the drain valve is
“C L OSED.”
2.Fill the fryer to the maximum hot oil fill line
with a mixture of cold water and fryer boil-out
solution. Carefully follow the manufacturer's
directions for mixing the boil-out solution.
3.Turn the Master Power Switch (located within
the front access door) to the “ON” position.
4.Push the E L E M E N T H I L IM IT reset button.
Within a few seconds, both LED's on the
operational control panel will display
“O F F” when the Master Power Switch is
initially engaged.
OPEN
CLOSED
PUMP
Of f
DO NOT leave the fryer unattended during the
boil-out process. The fryer must be continuously
monitored for boil-over conditions, particularly in
high-altitude locations. If boil-over occurs,
immediately press the power key to the “
OFF ”
position and allow the solution to cool. When the
solution has cooled, re-enter the boil-out mode.
NO TE:
To protect the pump from possible water
damage after the boilout procedure, fill the
kettle with oil and cycle through to remove
any excess water.
MASTER
POWER
SWITCH
NOTE: In i tial acc ess to the
IGNITION
ALARM
program ming mode
mus t start with the
DRAIN
con trol in the “OFF ”
pos ition.
Ga s Fr y er O per a t io n & Ca r e M a nua l • 1 6
O P E R A T I O N
BOIL-OUT SOLUTION AND SURROUNDING
METAL SURFACES BECOME EXTREMELY
HOT. TO AVOID BURNS, ALWAYS USE HAND
PROTECTION WHEN PERFORMING THE
BOIL-OUT FUNCTION AND FOLLOW THE
MANUFACTURER'S SAFETY INSTRUCTIONS
FOR THE BOIL-OUT PRODUCT BEING USED.
D E L U X E C O N T R O L B O I L - O U T
5.Press and hold the Program Key for
10 seconds.
“ B o i l ” wi ll al w ays appe a r a s th e
fir s t i t em i n t h e d i spla y
whe n ever the “ P R O G R A M ”
key is ini t ially pre s sed.
Bo il
Press the Right arrow key
to enter the “Bo il” program.
The display will indicate “READY ?”. Press the
arrow key to start the boil-out function.
Right
The boil-out solution will begin to heat to a
temperature of 195°F (91°C). When the
temperature has been reached, the appliance
will begin a 10 minute countdown.
NO TE: THE COUN TDO WN PERIO D W ILL
NO T S HOW IN T HE DIS PLAY
.
At the end of the boil-out period, an alarm will
sound and the control will revert to the “OFF”
state.
6.Rotate the drain to the “OP EN” position.
Allow the boil-out solution to completely drain.
Discard boil-out solution and return the trolley
to the fully inserted position beneath the fryer.
8.Following the boil-out procedure and rinse,
wipe all accessible metal surfaces in the interior
nd wipe all interior accessories with a clean,
a
dry cloth to remove remaining rinsing solution.
Clean and dry the fry baskets separately.
9.Wipe the exterior of the fryer cabinet with a
degreaser/sanitizer suitable for use on food
contact surfaces. Always follow the
manufacturer's instructions and/or mixing
directions for proper solution strengths.
Wipe exterior stainless steel surfaces with the
grain of the metal and avoid the use of abrasive
pads, steel wool, or metal implements.
10. Replace the oil filter.
ENSURE THERE IS NO WATER IN THE FRYPOT
BEFORE FILLI NG WI TH OI L/SHO RTENI NG.
WHEN COOKING COMPOUNDS ARE HEATED
TO COOKING TEMPERATURE, WATER IN THE
FRYPOT WILL CAUSE OIL TO SPLATTER AND
MAY BE A BURN HAZARD.
7.Rotate the drain valve clockwise to the
“CL OSED” position and follow the
manufacturers additional boil-out instructions to
rinse the frypot in order to neutralize boil-out
cleaner residue. Discard rinse solution.
Ga s Fr y er O per a t io n & Ca r e M a nua l • 1 7
O P E R A T I O N
D A N G E R
DISCONNECT UNIT FROM
POWER SOURCE BEFORE
CLEANING OR SERVICING.
D A N G E R
AT NO TIME SHOULD THE INTERIOR
OR EXTERIOR BE STEAM CLEANED,
HOSED DOWN, OR FLOODED WITH
WATER OR LIQUID SOLUTION OF
ANY KIND. DO NOT USE WATER JET
TO CLEAN.
SEVERE DAMAGE OR
ELECTRICAL HAZARD
COULD RESULT.
WARRANTY BECOMES VOID IF
APPLIANCE IS FLOODED
C A U T I O N
TO PROTECT STAINLESS STEEL
SURFACES, COMPLETELY AVOID
THE USE OF ABRASIVE CLEANING
COMPOUNDS, CHLORIDE BASED
CLEANERS, OR CLEANERS
CONTAINING QUATERNARY SALTS.
NEVER USE HYDROCHLORIC ACID
(MURIATIC ACID) ON STAINLESS
STEEL. NEVER USE WIRE
BRUSHES, METAL SCOURING
PADS OR SCRAPERS.
N
O
S
C
R
A
P
E
R
S
N
O
W
I
R
E
B
R
U
S
H
E
S
N
O
S
T
E
E
L
P
A
D
S
C L E A N I N G & M A I N T E N A N C E
THOROUGHLY CLEAN DAILY
The cleanliness and appearance of this unit
will contribute considerably to operating
efficiency and savory, appetizing food.
Good equipment kept clean works better
and lasts longer.
1. Disconnect unit from power source, and let cool.
2. Remove all detachable items. Clean these items
separately with a good grease solvent or
commercial detergent. Rinse well and dry.
3. Clean control panel, door vents, door handles,
and door gaskets thoroughly since these areas
harbor food debris. Rinse by wiping with
sponge and clean warm water. Wipe dry with
a clean cloth.
4. To help maintain the protective film coating on
polished stainless steel, clean the exterior of the
unit with a cleaner recommended for stainless
steel surfaces. Spray the cleaning agent on a
clean cloth and wipe with the grain of the
stainless steel.
NOTE: Avoid the use of abrasive cleaning,
compounds, chloride based cleaners,
or cleaners containing quaternary salts.
Never use hydrochloric acid (muriatic acid)
on stainless steel.
Always follow appropriate state or local health
(hygiene) regulations regarding all applicable cleaning
and sanitation requirements for foodservice equipment.
Ga s Fr y er O per a t io n & Ca r e M a nua l • 1 8
O P E R A T I O N
TO AVOID PERSONAL INJURY,
USE CAUTION WHEN SURFACES
BECOME SLIPPERY DUE TO
SPILLED OR DRIPPING OIL.
C A U T I O N
METAL PARTS OF THIS EQUIPMENT
BECOME EXTREMELY HOT WHEN IN
OPERATION. TO AVOID BURNS,
ALWAYS USE HAND PROTECTION
WHEN OPERATING THIS APPLIANCE.
A S F - 7 5 G O I L / S H O R T E N I N G F I LT R A T I O N
Careful observation of the finished food product will
help determine optimal filtering frequency. Filtering
he cooking oil at regular intervals will help ensure
t
food quality.
F O R B ES T R ES ULT S
: Do not allow thetemperature of the oil to decrease below the “Idl e
Mo d e” temperature of 250°F (121°C) when filtering.
Op erators must be made aware of t he
hazards involved in the operation of a hot
oil filtering system. On-site supervision
du ring the filt ration proce ss and the
cleaning process is strongly recommended.
A S F - 7 5 G W I T H O I L F I LT R A T I O N
H
-L
I
R
IL
O
IMIT
ESET
CONTROL
RESET
NOZZLE
KETTLE
SELECTOR
NOZZLE
CONNECTION
1. Open the front access door. With the
Kettle/Nozzle selector in the “N OZZLE OFF ”
osition, rotate the drain valve counterclock-
p
wise until rotation stops and the drain valve is
in the “OP EN” position. Power to the main
control panel will automatically switch “OFF.”
2. Allow contents of the fryer to completely drain.
3. Press the P UMP “ ON” to allow the oil to
circulate through the drain system to flush
crumbs. Using the brushes provided, brush the
sides and bottom of the fryer while the oil is
circulating through the system. Use the angle
brush under the heat exchangers.
4. Press the P UMP “ OFF” and allow contents of
the fryer to completely drain.
5. Rotate the drain valve clockwise to the
“CL OSED” position.
6. Press the P UMP “ ON” and allow the fryer to
refill to the recommended level adding
additional oil/shortening as required to
maintain proper fill level.
MASTER
POWER
SWITCH
IGNITION
ALARM
DRAIN
CLOSED
OPEN
PUMP
7. Press the P U M P “ OF F ” button.
8. After the frypot has completely refilled, pull
out the mobile oil trolley and discard the filter
into a proper receptacle. Clean the filter
assembly and oil trolley, if needed.
9. Replace the oil filter and return the trolley to
the proper position beneath the fryer.
10. Push the E L E M E N T H I L IM IT reset button.
11. Press and hold the “ON/OFF ” key on
the main control panel for 1-1/2 to 2 seconds to
energize the fryer. Continue normal fryer
operation after the preheat function has been
completed.
Ga s Fr y er O per a t io n & Ca r e M a nua l • 1 9
O P E R A T I O N
B FILTER
3 FILTER
FRAME
A FILTER
CARTRIDGE
CL
IP
FRA
M
E
L
IP
A S F - 7 5 G O I L / S H O R T E N I N G F I LT R A T I O N
FILTER REPLACEMENT
. With the D RAIN in the “ CLOSED” position, pull the trolley from the fryer and disconnect the hose
1
from the fryer.
2.Pushing down on filter frame
clip, pull side
of filter cartridge closest to clip upwards.
Slide opposite edge of filter cartridge out from
beneath the filter frame lip.
3.Remove and discard used filter .
4.Place new filter next to screen on underside of
filter cartridge and reverse step 2 above.
5.Reconnect hose to fryer and return trolley to
the full position under the fryer.
STANDARD AND OPTIONAL FILTERS
PART NO.DESCRIPTION
FI-27791PAPER (STANDARD WITH FRYER) 7-count package
FI-27794PAPER (STANDARD WITH FRYER) 100-count package
FI-27648CHARCOAL/CARBON FILTER 30-count pkg.
FI-27014REUSABLE MESH FILTER, single
Ga s Fr y er O per a t io n & Ca r e M a nua l • 2 0
TO AVOID PERSONAL INJURY,
USE CAUTION WHEN SURFACES
BECOME SLIPPERY DUE TO
SPILLED OR DRIPPING OIL.
C A U T I O N
METAL PARTS OF THIS EQUIPMENT
BECOME EXTREMELY HOT WHEN IN
OPERATION. TO AVOID BURNS,
ALWAYS USE HAND PROTECTION
WHEN OPERATING THIS APPLIANCE.
A S F - 7 5 G O I L / S H O R T E N I N G F I LT R A T I O N
FILTER CLEANING & MAINTENANCE
O P E R A T I O N
NOTE:
R E U S A B L E M E S H FI LTE R O PT IO N:
Clean the reusable mesh filter ( FI-27014) by
spraying thoroughly with hot water. DO NOT clean
in the dishwasher. DO NOT use detergents to clean.
Detergents and detergent residues will significantly
reduce the life of oil and shortening products.
Make certain the filter is performing efficiently by
inspecting the filter each time it is cleaned.
Examine for cuts and holes. For the best results,
replace the filter whenever necessary.
Make certain to use hand protection when
working with hot surfaces.
A WORN F ILTER WILL A FFEC T
PR ODUC T FRYING R ESULTS .
To discard deteriorated oil/shortening, the trolley
can be pulled from the fryer and can be rolled to a
convenient location for use with a pumping device.
ALWAYS MAKE CERTAIN THE TROLLEY IS
PRO P E R LY POSITIO N E D BENEATH THE
FRYER BEFORE OPERATION .
TO P REVE NT FI LTER DAM AGE, D O
NO T USE S HARP I MPLE MENT S TO
RE MOVE S CRAP S FRO M THE F ILTER.
Make certain the filter is securely fastened to the
support basket before returning the assembly to
the trolley.
Ga s Fr y er O per a t io n & Ca r e M a nua l • 2 1
O P E R A T I O N
TO AVOID SERIOUS PERSONAL
INJURY DO NOT STAND ON THE
FRYER OR FRYER COVER. THE
FRYER COVER IS DESIGNED TO
HOLD A MAXIMUM OF 10-POUNDS
(4,5 Kg) OF WEIGHT.
A S F - 7 5 G O I L / S H O R T E N I N G F I LT R A T I O N
CLEANING & MAINTENANCE
O I L D IS CA R D HO SE O P T I O N :
The oil discard hose option (HO-27686) is available
as an option to assist both the boil-out and
filtration operation.
With the discard hose attached to the nozzle
connection, place the Kettle/Nozzle selector
in the “NOZ ZLE ON” position.
NOZZLE
POSITION
NOZZLE
CONNECTION
The drain can be placed in the “OPEN” or
“C L OSED” position as required.
Disconnect hose following use and return the
selector to the “N OZZLE OFF” position.
Nozzle will contain a small amount of oil after use.
Dispose of properly.
Ga s Fr y er O per a t io n & Ca r e M a nua l • 2 2
O P E R A T I O N
S U GG E ST E D F R Y IN G TI M ES
I T E MM I N U T E STE MP E R AT U R ED I S P L AY
THE TIMES AND TEMPERATURES ARE SUGGESTED GUIDELINES ONLY. ALL COOKING SHOULD BE BASED ON INTERNAL PRODUCT TEMPERATURES. DUE TO VARIATIONS IN PRODUCT QUALITY,
WEIGHT, AND DESIRED DEGREE OF DONENESS, THE COOKING TIMES AND TEMPERATURES MAY NEED TO BE ADJUSTED ACCORDINGLY. ALWAYS FOLLOW LOCAL HEALTH (HYGIENE)
REGULATIONS FOR ALL INTER NAL TEMPERATURE REQUIREMENTS.
P R O G R A M K E Y S
AL L SUGG EST ED FRYING T IME S ARE B ASE D ON A FULL LOA D OF PRODU CT
Remove ice crystals and ensure that food is dry before frying. Excessive water and ice can cause oil to splatter or overflow. Do not
over fill the basket. Food needs to be surrounded by oil for best frying results.
Ga s Fr y er O per a t io n & Ca r e M a nua l • 2 3