TABLE OF CONTENTS
Introduction.........................................................................
Thank you for purchasing one of
Alpine’s Cyclone pumps.
At Alpine, our goal is to supply our customers with
quality products that provide convenience and value to your life. We hope you enjoy your purchase and thank you for choosing Alpine: Your One Stop
Shop for all your Solar, Gift, Garden and Pond Supplies.
Our Cyclone pumps are ideal for heavy duty waterfall or lter systems, as they have the needed power to move large quantities of water through your water feature. They are designed for continuous operation even in the harshest pond environments.
2
Safety Information.............................................................
Components and Pump Parts........................................
Installation............................................................................
Operation and Maintenance..........................................
Replacing the Impeller.....................................................
Winter Pump Care..............................................................
Troubleshooting.................................................................
Replacement Parts List.....................................................
2
3
4
6
7
9
9
10
LIMITED 3 YEAR WARRANTY
At their own discretion, Alpine Corporation will repair or replace any pump found to have Manufacturer’s defects as
follows: Pump body, cover, lter and accessories within three years of original purchase. Impeller and internal moving parts are warranted for one year of original purchase. This warranty does not cover any replaceable ltering material supplied with the pump or lter as it is considered expendable. Proof of purchase is required. Warranty does not cover damage resulting from negligent handling, misuse or lack of reasonable maintenance or care. Warranty is valid against defects due to material and the company’s workmanship only. The sole obligation is at Alpine’s discretion to replace/repair the defective unit with a suitable replacement part. Units should be checked for proper operation prior to returning as defective. No liability for loss or damage of any nature or kind, whether arising out of or from the use of the product, whether defective or not defective, is assumed by Alpine Corporation or its aliates. Damaging, cutting or altering power cord, removing or defacing product labels voids any warranty consideration. Damages or injuries resulting from negligence or misuse of the product are not covered by warranty.
For more information about our company or products, please visit our website at www.alpine4u.com or call us (USA) 1-877-710-0162
1
INTRODUCTION
The Cyclone pump is ideal for pond owners looking for energy-ecient performance, ow, and ease of maintenance. The Cyclone pumps come with a high-performance, extremely sturdy, asynchronous motor and 33­foot cord. This versatile pump can be used vertically, horizontally, and in or out of water. The pump features simple maintenance, with a removable rotor assembly, water-resistant ceramic bearings for continuous and trouble-free use. Your Alpine Cyclone pump is oil-free, magnetic-driven and is epoxy protected, with a ceramic shaft for long lasting dependable performance. This pump is equipped with a pre-lter cage which handles solids up to a quarter inch in size. For a car to stay in great condition, proper maintenance is required. Therefore, Alpine suggests that once a week, you verify that the pump is performing satisfactorily. If you detect a drop in pump performance (such as a decrease in water ow from the pump or to the waterfall), rst clean the pump’s pre-lter cage and the tubing connected to the pump. If the water ow is still not fully restored to its original performance, simply clean the impeller and internal pump
(See page 6 for maintenance instructions)
body.
SAFETY INFORMATION
WARNING: Risk of electric shock – This pump has not been approved for use in swimming pool or marine areas WARNING: To provide continued protection against risk of electric shock, connect to properly grounded, ground
fault circuit interrupter (GFCI) outlets only, using the following guidelines:
(A) Read and follow all safety instructions and all the important notices on the appliance before using the pump. Failure to do so may result in loss of sh life and/or damage to this appliance. (B) Have a qualied electrician install a properly grounded receptacle outlet, acceptable for outdoor use and protected from snow and rain. (C) Any wiring of pumps should be performed by a qualied electrician to ensure code compliance and user safety. (D) This is a pond pump. This pump has been evaluated for use with water only. Do not use this pump for other than intended use (i.e.: do not use in swimming pools, aquariums, etc. Not to be used as a sump pump.) (E) Do not use this pump in swimming pools or other situations where people are immersed (F) If an extension cord is necessary, ensure connection is watertight and dust proof. A cord with proper rating should be used. A cord rated for less amps or watts than the appliance rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled. The connection should be carried out by a qualied electrical installer. (G) Unplug pump at receptacle outlet when not in use or before removal from pond. (H) To reduce risk of electrical shock, all wiring and junction connections should be made per local codes. Requirements may vary depending on usage and location. (I) Inspect the power cable before using. The power cable should be protected at all times to avoid punctures, cuts, bruises and abrasions. Never cut the cord. (J) Never handle power cords with wet hands. (K) To avoid injury, do not touch moving or hot parts. (L) Do not use power cable to lift pump. (Figure 1.1)
IMPORTANT: Alpine Corporation is not responsible for losses, injury, or death resulting from a failure to observe
these safety precautions, misuse or abuse of pumps or equipment.
For more information about our company or products, please visit our website at www.alpine4u.com or call us (USA) 1-877-710-0162
Figure 1.1
2
COMPONENTS AND PUMP PARTS
v
u
w
x
uPump Body zRubber Fitting For
Multi-Hose Adapter For Models:
•PAL2100 •PAL5200
•PAL3100 •PAL6550
•PAL4000 •PAL8000
vO-Ring {Multi-Hose Adapter-
0.75”-1.5
For Models:
•PAL2100 •PAL5200
•PAL3100 •PAL6550
•PAL4000 •PAL8000
y
(Figure 2.1)
wImpeller |Multi-Hose Adapter-
1”-1.25
For Models:
•PAL2100 •PAL5200
•PAL3100 •PAL6550
•PAL4000 •PAL8000
xPump Body Cover }1 3/4” Adapter Fitting
A. (PAL2100 - PAL3100) B. (PAL4000 - PAL8000)
yPump Pre-lter Cage ~3 1/2” Adapter Fitting
For Model:
•PAL10300
3
For more information about our company or products, please visit our website at www.alpine4u.com or call us (USA) 1-877-710-0162
(Chart 1.1)