Alpha FPR1207-F Quick Start Guide

Specifi cations
Input
AC Input Volt age:
Input Freq uency: 50/60Hz
Output
Operational O utput Powe r: 7W (ONT load)
Output Voltage: 12Vdc Nomina l (Batte ry volt age upon l oss of AC)
Conne ction: F-type coax ial (Cor ning Gilbert R G6 or sma ller)
Battery
Typ e: 7.2 Ah AG M
Rech arge T ime 18 Hours to 9 0%
Battery Backup
Provide s approxi mately 20 H ours of backup at 3.5 W*
Provide s approxi mately 12 Hou rs of backup at 7W*
*Base d on new, fully -cha rged bat tery
Physical
Housin g Size (in/mm): 8.75W x 7.75H x 3.0D/222W x 197H x 76D
Weight (lb./kg): 1.3/0.59
Batter y 7.2Ah (lb. /kg): 5.7/2.6
Visual Status Indicators
Green LE D: AC mode
Green LE D Flashin g: Batter y mode
Red LED: Replace batter y
Red LED fl ashing: Batter y miss ing/L ow battery
Audible Status Indicators
Loss of In put Power: Si ngle, one second b eep
Low Batt ery: Single 0.5 second beep ever y 15 secon ds at 25% SOC
Replace Batter y: Double b eep every 15 minutes
Push Buttons
Silenc e Alar m: Suppre sses the audible a larm for 24 hours
Battery Emer gency Use: Acces ses res erve bat tery capaci ty
Agency Compliance
Safety (US): NRTL certifi ed to UL/CSA 60950-1 Ed. 2 (ITE) (Pollution Degree 2, Overvoltage Cat-
Safety (other): IEC 60950-1:2005 + National Deviations. (Pollution Degree 2, Overvoltage
Safety (EU): CE, EN 60950-1:2006
EMC (US): FCC part 15 subpart b, Class B
EMC (EU): CE, EN 55022:2006 (CISPER 22) (Emissions) Class B, EN 55024:1998 +A1 +A2
Environment
Storag e Temperatur e: -20°C to +50° C (-4°F to +122°F)
Operating Tempera ture: 0°C to 40°C (32°F to 10 4°F)
Note: Ope rating temperat ures based on AX-LONGBAT-7
Humidi ty: 5% to 95%
Elevation Operation (max.):
Elevation Storage (ma x.): 50,000ft (15,000m)
Battery Stor age: -20°C to + 40°C (- 4°F to +104°F)
Warrant y
FlexPoin t FPR1207-F: 3-year, repair o r replac e
Batter y: Contac t Alpha Tech nologi es for model-s pecifi c warrant y coverage
120Vac /240Vac
egory II), LPS Output, SELV
Category II), LPS Output, SELV
(Immunity), EN 61000-3-2:2006 (Harmonics), EN 61000-3-3 (Fluctuations and Flicker) CE, RoHS compliant
0 to 10,000ft (0 to 3,000m) — derate 2 °C per 1,000f t (305m) above 6,000ft (1830 m)
(six month s max. sto rage dur ation at 25°C / 77°F wi thout a re charge)
FlexPoint™ FPR1207-F Quick Start Guide
FTTx UPS System for ONTs — Model FPR1207-F
Review the drawings and illustrations contained in this guide
before proceeding. For additional details on installation and
operation, visit www.alpha.com and download a copy of the FlexPointTM FPR1207-F/FPR1207-F Technical Manual.
The FPR1207-F is an optical network terminal (ONT) power supply that provides 7W of primary and standby power at 12Vdc. The FPR1207-F converts customer supplied 120Vac/240Vac, 50/60Hz outlet voltage to a 12Vdc output. Status reporting is provided locally via audible and visual alarms. Standby power is provided by one 7.2Ah battery installed in the FPR1207-F. Upon loss of AC power the FPR1207-F supports the load until the battery reaches 25% remaining usable capacity. At that point, the FPR1207-F enters sleep mode preserving capacity for emergency calls. Pressing the Emergency Use button accesses the remaining capacity.
ONT
Up to 6' (1.8m)
FlexPoint
FPR1207-F
TM
FPR1207-F RG6 or
similar home coax
cabling. Up to 50'
(15m)
Network
Area
Customer
Area
Fig. 1, System Block Diagram
CAUTION!
The power supply cord is used as the main disconnect device. Verify the socket/outlet is located/ installed near the equipment and is easily accessible.
Installing and Connecting the FPR1207-F
1. Unpack and inspect the FPR1207-F.
2. The unit is designed for use in a sheltered environment protected from rain and snow. Its operating temperature range is 0°C to 40°C / 32°F to 104°F (ambient). Install the unit near an AC outlet.
3. Remove battery compartment door by pressing tab and opening door. Remove the door and set aside until the installation process is complete.
4. Determine the necessary cable length to provide appropriate service loops between the FPR1207-F, the ONT, and the outlet. Plug the line cord into the receptacle on the back of the FPR1207-F. Do not plug the FPR1207-F into an AC outlet until the last step of the installation procedure.
5. Mount the FPR1207-F to the wall with #12 fasteners or equivalent, using the keyholes for easy mounting. For applications (with 7.2Ah battery only) with higher seismic requirements, use the round holes in the back of the unit for direct fastening to a stud or other structural feature.
6. Connect Coax cable to F-type connector. Torque to between 4.1 in-lbs and 6.1 in-lbs.
010-344-B0-001 Rev. B (2/2014)
14
.200"
2
Ø.380"
Ø.250"
1
2
1
3.0"
8.7"
221mm
Mounting holes for customer-supplied #12 hardware or equivalent
1 2
"Keyhole" slots for easy mounting
76mm
2.5"
63.5mm
1.3"
33mm
3.0"
76mm
2.4"
61mm
7.8"
198mm
WARNING!
Risk of explosion if battery is replaced by an incorrect type. Recycle spent batteries in accordance with local regulations.
Battery Installation / Replacement Procedure
1. (Failed Battery Replacement) For units with Alpha part number 010-344-20-001 (note that the fi nal
three digits in bold are the key indicator), disconnect the AC line cord from the AC power outlet before beginning battery replacement.
2. (Battery Replacement / Failed Battery Replacement) Disconnect the wire harness to the battery.
3. Connect the wire harness to the charged battery (a fully charged battery reads about 13Vdc).
4. Install the battery in the cradle as shown in Fig. 8. The locking tab secures it in place.
5. Replace the battery compartment door. To replace the front cover, align the hinges with the hinge sockets
and press them in with the door perpendicular with the main housing. Rotate the door closed until the closure door latches.
6. Plug the FPR1207-F into an AC power outlet. The Green LED should light.
7. Verify the unit is functioning properly by unplugging the unit. The alarm should sound for one second and
the Green LED should fl ash. The unit will be running on standby battery power.
8. Re-plug the FPR1207-F into an AC power outlet. The unit is ready to be placed into service.
Fig. 2, FPR1207-F Dimensions (in/mm)
(Viewed From Back)
Silence
Alarm
Battery
Emergency
Use
Silence
Alarm
Battery
Emergency
Use
Fig. 3, RF Cable Connection Fig. 5, AC Power Cord Connection
Fig. 4, Push Button Detail
(Viewed From Back)
2
Fig. 6, 7.2Ah Battery
Fig. 7, Battery Compartment,
With Wire Harness
FPR1207-F Controls and Indicators
VISUAL STATUS INDICATORS
Green LED: AC mode
1
1
Green LED fl ashing: Battery mode
2
Red LED: Replace battery
2
Red LED fl ashing: Battery missing / Low battery
010-344-B0-001 Rev. B (2/2014)010-344-B0-001 Rev. B (2/2014)
R
Fig. 8, Battery
Installed
Remove cover to access silence alarm and battery emergency use buttons.
1
2
3
Loading...