Specifications
Input |
|
AC Input Voltage: |
120Vac/240Vac |
Input Frequency: |
50/60Hz |
Output |
|
Operational Output Power: |
7W (ONT load) |
Output Voltage: |
12Vdc Nominal (Battery voltage upon loss of AC) |
Connection: |
F-type coaxial (Corning Gilbert RG6 or smaller) |
Battery |
|
Type: |
7.2Ah AGM |
Recharge Time |
18 Hours to 90% |
Battery Backup |
|
Provides approximately 20 Hours of backup at 3.5W* |
|
Provides approximately 12 Hours of backup at 7W* |
|
*Based on new, fully-charged battery |
|
Physical |
|
Housing Size (in/mm): |
8.75W x 7.75H x 3.0D/222W x 197H x 76D |
Weight (lb./kg): |
1.3/0.59 |
Battery 7.2Ah (lb./kg): |
5.7/2.6 |
Visual Status Indicators |
|
Green LED: |
AC mode |
Green LED Flashing: |
Battery mode |
Red LED: |
Replace battery |
Red LED flashing: |
Battery missing/Low battery |
Audible Status Indicators |
|
Loss of Input Power: |
Single, one second beep |
Low Battery: |
Single 0.5 second beep every 15 seconds at 25% SOC |
Replace Battery: |
Double beep every 15 minutes |
Push Buttons |
|
Silence Alarm: |
Suppresses the audible alarm for 24 hours |
Battery Emergency Use: |
Accesses reserve battery capacity |
Agency Compliance |
|
Safety (US): |
NRTL certified to UL/CSA 60950-1 Ed. 2 (ITE) (Pollution Degree 2, Overvoltage Cat- |
|
egory II), LPS Output, SELV |
Safety (other): |
IEC 60950-1:2005 + National Deviations. (Pollution Degree 2, Overvoltage |
|
Category II), LPS Output, SELV |
Safety (EU): |
CE, EN 60950-1:2006 |
EMC (US): |
FCC part 15 subpart b, Class B |
EMC (EU): |
CE, EN 55022:2006 (CISPER 22) (Emissions) Class B, EN 55024:1998 +A1 +A2 |
|
(Immunity), EN 61000-3-2:2006 (Harmonics), EN 61000-3-3 (Fluctuations and Flicker) |
|
CE, RoHS compliant |
Environment |
|
Storage Temperature: |
-20°C to +50°C (-4°F to +122°F) |
Operating Temperature: |
0°C to 40°C (32°F to 104°F) |
Note: Operating temperatures based on AX-LONGBAT-7 |
|
Humidity: |
5% to 95% |
Elevation Operation (max.): |
0 to 10,000ft (0 to 3,000m) — derate 2°C per 1,000ft (305m) above 6,000ft (1830m) |
Elevation Storage (max.): |
50,000ft (15,000m) |
Battery Storage: |
-20°C to +40°C (-4°F to +104°F) |
|
(six months max. storage duration at 25°C / 77°F without a recharge) |
Warranty |
|
FlexPoint FPR1207-F: |
3-year, repair or replace |
Battery: |
Contact Alpha Technologies for model-specific warranty coverage |
Alpha Technologies 3767 Alpha Way Bellingham, WA 98226 USA Tel: +1 360 647 2360 Fax: +1 360 671 4936 www.alpha.com Alpha Technologies Ltd. 7700 Riverfront Gate Burnaby, BC, V5J 5M4 CANADA Tel: +1 604 436 5900 Fax: +1 604 436 1233 Due to continuing product improvements, Alpha reserves the right to change specifications without notice.
Copyright © 2014 Alpha Technologies, Inc. All rights reserved. Alpha is a registered trademark of Alpha Technologies. 010-344-B0-001 Rev. B (2/2014)
FlexPoint™ FPR1207-F Quick Start Guide
FTTx UPS System for ONTs — Model FPR1207-F
Review the drawings and illustrations contained in this guide before proceeding. For additional details on installation and operation, visit www.alpha.com and download a copy of the FlexPointTM FPR1207-F/FPR1207-F Technical Manual.
The FPR1207-F is an optical network terminal (ONT) power supply that provides 7W of primary and standby power at 12Vdc. The FPR1207-F converts customer supplied 120Vac/240Vac, 50/60Hz outlet voltage to a 12Vdc output. Status reporting is provided locally via audible and visual alarms. Standby power is provided by one 7.2Ah battery installed in the FPR1207-F. Upon loss of AC power the FPR1207-F supports the load until the battery reaches 25% remaining usable capacity. At that point, the FPR1207-F enters sleep mode preserving capacity for emergency calls. Pressing the Emergency Use button accesses the remaining capacity.
ONT
|
FlexPointTM |
|
Network |
Customer |
|
FPR1207-F |
|
Area |
Area |
Up to 6' (1.8m) |
|
|||
FPR1207-F RG6 or |
|
|||
|
|
|||
|
|
similar home coax |
|
|
|
|
cabling. Up to 50' |
|
|
|
|
(15m) |
|
Fig. 1, System Block Diagram
CAUTION!
The power supply cord is used as the main disconnect device. Verify the socket/outlet is located/ installed near the equipment and is easily accessible.
Installing and Connecting the FPR1207-F
1.Unpack and inspect the FPR1207-F.
2.The unit is designed for use in a sheltered environment protected from rain and snow. Its operating temperature range is 0°C to 40°C / 32°F to 104°F (ambient). Install the unit near an AC outlet.
3.Remove battery compartment door by pressing tab and opening door. Remove the door and set aside until the installation process is complete.
4.Determine the necessary cable length to provide appropriate service loops between the FPR1207-F, the ONT, and the outlet. Plug the line cord into the receptacle on the back of the FPR1207-F. Do not plug the FPR1207-F into an AC outlet until the last step of the installation procedure.
5.Mount the FPR1207-F to the wall with #12 fasteners or equivalent, using the keyholes for easy mounting. For applications (with 7.2Ah battery only) with higher seismic requirements, use the round holes in the back of the unit for direct fastening to a stud or other structural feature.
6.Connect Coax cable to F-type connector. Torque to between 4.1 in-lbs and 6.1 in-lbs.