AT-WDM02
Management Module
Installation Guide
Allied Telesyn, Inc.
960 Stewart Drive, Suite B
Sunnyvale, CA 94085 USA
Tel 1 (408) 730-0950 • Fax 1 (408) 736-0100
Visit our web site at: www.alliedtelesyn.com
Related Documents
The Allied Telesyn web site at www.alliedtelesyn.com contains the most
recent documentation, software, and technical information for all of our
products. For details on the features and functions of your Allied Telesyn
AT-WD1008 chassis, refer to the following manuals from our web site:
❑ AT-WD1008 Gigabit Ethernet Wavelength Division Multiplexer
Installation Guide
PN 613-50367-00
❑ AT-S47 Management Software User’s Guide
PN 613-50371-00
Package Contents
Make sure the following items are included in the shipping package. If any
item is missing or damaged, contact your Allied Telesyn sales
representative.
❑ One AT-WDM02 Management Module
❑ One management cable
❑ This installation guide
❑ Warranty card
3. Remove the AT-WDM02 Management Module from the shipping
package.
Caution
The management module can be damaged by static electricity. Be
sure to observe all electrostatic discharge (ESD) precautions to
avoid damaging the module. You should wear an antistatic wrist
strap and handle the module only by the edges or the front
faceplate.
4. If you intend to manage the multiplexer from a remote
management workstation on your network, set the 10Base-T port on
the module to either MDI or MDI-X using the switch located on the
module behind the 10Base-T port. This will eliminate the need for a
crossover cable. If you will be connecting the 10Base-T port to an
Ethernet switch or hub, the correct setting in most cases will be MDI.
MDIMDI-X
Overview
The AT-WDM02 module is an optional management module for the
AT-WD1008 Wavelength Division Multiplexer. The module allows you to
manage the multiplexer from a terminal connected to the management
module or from a management station on your network. With the module
you can monitor the status of the ports on the multiplexer, enable or
disable ports, run diagnostics, and more. The AT-S47 Management
Software and the management interface, a menu-oriented program that
makes managing the multiplexer simple and easy, come pre-installed on
this optional management module.
TERMINAL
COL
10BASE-T PORT
RX
LNK
RS-232
PO
W
ER
STA
TU
S
RES
ET
Installing the AT-WDM02 Management Module
1. Power OFF the AT-WD1008 Multiplexer using the ON/OFF power
switches on the back panel of the unit. If the unit contains a
Redundant Power Supply (RPS), be sure to power OFF the RPS as well.
Caution
Installing the AT-WDM02 Management Module with the multiplexer
powered ON can damage the management module.
2. Using a flathead screwdriver, loosen the captive screw that secures the
blank faceplate over the management module expansion slot and
remove the faceplate.
CH 3
TX
RX
POWER
SUPPLY A
RX TX
CH 4
TX
RX
LNK
TS
T
TX
WEST
R
X
LN
NO
SNMP MODULE
EAST
K
RM
EAST
LN
TST
RX
K TST
TX
R
X
A
L
CH 5
TX
POWER
SUPPLY B
RX
TX
RX
C
TERMINAL
COL
RX
10BASE-T PORT
LNK
RS-232
STATUS
POWER
RESET
5. Slide the management module into the expansion slot.
CH 3
10BASE-T PORT
TX
RX
POWER
SUPPLY A
C
O
L
R
X
L
N
K
RX TX
TERMINAL
RS-232
TX
CH 4
S
T
A
T
RX
P
O
W
E
R
U
S
R
E
S
E
T
LNK
TST
TX
W
EST
RX
SNMP MODULE
EAST
LNK
EAST
LN
K
TS
N
O
RM
AL
RX
TS
T
TX
RX
T
TX
CH 5
POWER
SUPPLY B
RX
TX
R
X
C
PN 613-50368-00 Rev A 1
2
3
6. Using a flathead screwdriver, secure the module to the AT-WD1008
chassis by tightening the captive screw.
CH 3
TX
RX
POWER
SUPPLY A
RX TX
CH 4
TX
RX
10B
A
SE
-T P
O
LNK TST
TX
WEST
RX
COL
RX
LNK
R
T
SNMP MODULE
EAST
LNK TST
EAST
LNK TST
NORMAL
TE
R
M
IN
A
R
S
-232
RX
CH 5
TX
POWER
SUPPLY B
RX
TX
RX
C
TX
RX
L
POWER
STATUS
RESET
9. If you are installing the AT-WD1008 Multiplexer for the first time, refer
to the AT-WD1008 Installation Guide for instructions on how to
complete the installation. Otherwise, power ON the AT-WD1008
Multiplexer. If the multiplexer contains an RPS unit, power ON the RPS
unit as well.
This completes the installation procedure for the management module.
For instructions on how to establish a management session, refer to the
AT-S47 Management Software User’s Guide, available from the Allied
Telesyn web site.
Port Pinouts
1234567 8 7 6
52413
RJ-45 RS-232
RJ-45 Port Pinouts
MDI Setting MDI-X Setting
Pin Signal Pin Signal
7. Attach the MiniDIN8 connector on the management cable to the
RS-232 port on the management module. Attach the other end
of the cable to a terminal or a personal computer with a terminal
emulator program.
CH 3
TX
RX
POWER
SUPPLY A
RX TX
CH 4
TX
RX
10BASE-T PORT
LNK TST
TX
W
EST
RX
LNK TST
NORMAL
TERMINAL
COL
RX
LNK
RS-232
SNMP MODULE
LNK TST
EA
ST
EAST
TX
RX
STATUS
RX
TX
CH 5
POW
ER
RESET
POWER
SUPPLY B
RX
TX
RX
C
8. To manage the multiplexer from a remote management station,
connect a Category 3 or better twisted pair cable with an RJ-45
connector to the 10Base-T port on the management module.
Connect the other end of the twisted pair cable to a half-duplex
10 Mbps or 10/100 Mbps port on an Ethernet hub or switch.
CH 3
TX
RX
POWER
SUPPLY A
RX TX
CH 4
TX
RX
10BASE-T PORT
L
NK
TST
T
X
WEST
R
X
TERMINAL
COL
RX
LNK
RS-232
SNMP MODULE
EAST
LN
EAST
LN
K TS
N
OR
M
RX
K
TST
TX
RX
T
A
L
POWER
STATUS
RESET
CH 5
TX
POWER
SUPPLY B
RX
TX
RX
C
Reset Button
On the front panel of the management module is a Reset button. Pressing
the button resets the AT-WDM02 Management Module. Resetting the
management module does not interrupt the flow of data traffic through
the multiplexer.
Management Module LEDs
LED Color Description
COL Flashing
Yellow
RX Flashing
Green
LNK Solid Green A valid link has been detected on the
STATUS Solid Green The module is functioning normally.
Solid Amber The module is performing a self-test.
Flashing
Amber
Solid Red The module or management software is
POWER Solid Green The management module is receiving
Note
For information on the AT-WD1008 LEDs, refer to the AT-WD1008
Installation Guide.
Collisions are occurring between the
10Base-T port on the management
module and the Ethernet hub or switch
to which the port is connected.
The 10Base-T port is receiving packets.
RJ-45 port.
The module is downloading firmware
from a host PC.
malfunctioning.
power.
1Transmit +1Receive +
2Transmit -2Receive -
3 Receive + 3 Transmit +
6 Receive - 6 Transmit -
RS232 Port Pinouts
Pin Signal Pin Signal
1 NOT USED 5 DSR - Data Set Ready
2 DTR - Data Terminal
6 SG - Signal Ground
Ready
3 TX - Transmit Data 7 RTS - Request To Send
4 RX - Receive Data 8 CTS - Clear To Send
Electrical Safety and Emission Statement
Standards: This product meets the following standards when installed in compliant host equipment.
U.S. Federal Communications Commission
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital
device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with this instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can
void your right to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing
Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel
brouilleur du Canada.
Emission FCC Class A, EN55022 Class A, VCCI Class A, EN6100-3-2, EN6100-3-3
WARNING: In a domestic environment this product may cause radio interfer ence in which case
the user may be required to take adequate measures.
Immunity EN55024
Electrical Safety UL60950 (cULus), EN60950 (TUV)
Copyright 2003 Allied Telesyn, Inc. All rights reserved.
No part of this publication may be reproduced without prior written permission from Allied Telesyn Inc.
4 5 6