Allied Telesis AT-MR820TR User Manual

Page 1

CentreCOM

®

AT-MR420TR AT-MR820TR

Multiport Micro Repeaters

Installation Guide

PN 613-10625-00 Rev A
Page 2
Copyright 1997 Allied Telesyn International Corp. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesyn International Corp.
Allied Telesyn International Corp. reserves the right to make changes in specifications and other information contained in this document without prior written notice. The information provided herein is subject to change without notice. In no event shall Allied Telesyn International Corp. be liable for any incidental, special, indirect, or consequential damages whatsoever, including but not limited to lost profits, arising out of or related to this manual or the information contained herein, even if Allied Telesyn International Corp. has been advised of, known, or should have known, the possibility of such damages.
Trademarks: Ethernet is a registered trademark of Xerox Corporation. UNIX is a registered trademark of UNIX System Laboratories. Novell and NetWare are registered trademarks of Novell, Inc. Microsoft and MS-DOS are registered trademarks and LAN Manager and Windows for Workgroups are trademarks of Microsoft Corporation. 3Com is a registered trademark of 3Com. PC-NFS is a trademark of Sun Microsystems, Inc. PC/TCP is a registered trademark of FTP Software, Inc. DECnet is a registered trademark of Digital Equipment Corporation.
All company names, logos, and product designations that are trademarks or registered trademarks are the property of their owners.
Page 3

Electrical Safety and Installation Requirements

U.S. Federal Communications Commission

RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved by the manufacturer or the FCC can void your right to operate this equipment.

Canadian Department of Communications

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appariel numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
STANDARDS: RFI Emission WARNING:
in which case the user may be required to take adequate measures.
Immunity
These products have been safety tested by UL to Standard UL 1950, CSA to CSA 950 and by TUV to EN60950.
SAFETY ELECTRICAL NOTICES
WARNING: ELECTRIC SHOCK HAZARD To prevent ELECTRIC shock, do not remove cover. No user-serviceable parts inside. This unit contains HAZARDOUS VOLTAGES and should only be opened by a trained and qualified technician. To avoid the possibility of ELECTRIC SHOCK, disconnect electric power to the product before connecting or disconnecting the LAN cables.
LIGHTNING DANGER DANGER
LIGHTNING ACTIVITY.
CAUTION
ENERGISE EQUIPMENT, disconnect the power cord.
This product meets the following standards
: EN55022 Class A
In a domestic environment this product may cause radio interference
: EN50082-1
: DO NOT WORK on equipment or CABLES during periods of
: POWER CORD IS USED AS A DISCONNECTION DEVICE. TO DE-
iii
Page 4
INSTALLATION ELECTRICAL
This product will automatically adjust to any voltage between the ranges shown on the label.
ELECTRICAL—TYPE CLASS 1 EQUIPMENT
THIS EQUIPMENT MUST BE EARTHED. Power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts.
ELECTRICAL
Use power cord, maximum 4.5 meters long, rated 6 amp minimum, 250V, made of HAR cordage molded IEC 320 connector on one end and on the other end a plug approved by the country of end use.
MOUNTING INSTRUCTIONS CAUTION
VERTICAL MOUNTING must not be done without the use of an Allied Telesyn vertical mount chassis designed for this purpose.
CAUTION
ambient air for cooling.
CAUTION
vertical mounting chassis is being used.
OPERATING TEMPERATURE
This product is designed for a maximum ambient temperature of 40° C.
ALL COUNTRIES:
Electrical Codes.
—AUTO VOLTAGE ADJUSTMENT
—CORD NOTICE
: These models are designed for operation in the HORIZONTAL position.
: Air vents must not be blocked and must have free access to the room
: DO NOT detach rubber feet from the product unless an Allied Telesyn
Install product in accordance with local and National
NORMEN: Hochfrequenzstörung: WARNUNG:
hervorrufen. In diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen.
Störsicherheit:
Die Sicherheitsprüfung dieser Produkte wurde von Underwriters Laboratories Inc. gemäß Norm 1950, CSA nach CSA 950 und gemäß TÜV nach EN60950 durchgeführt.
SICHERHEIT ACHTUNG: Das Gehäuse nicht öffnen. Das Gerät enthält keine vom Benutzer wartbaren Teile. Das Gerät steht unter Hochspannung und darf nur von qualifiziertem technischem Personal geöffnet werden. Vor Anschluß der LAN-Kabel, Gerät vom Netz trennen.
GEFAHR DURCH BLITZSCHLAG GEFAHR
ausführen.
VORSICHT
STROMVERSORGUNG. ZUR TRENNUNG VOM NETZ, KABEL AUS DER STECKDOSE ZIEHEN.
INSTALLATION AUTOMATISCHE SPANNUNGSEINSTELLUNG
Dieses Gerät stellt sich automatisch auf die auf dem Etikett aufgeführten Spannungswerte ein.
Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen.
EN55022 Klasse A
Bei Verwendung zu Hause kann dieses Produkt Funkstörungen
EN50082-1
GEFÄHRLICHE SPANNUNG
: Keine Arbeiten am Gerät oder an den Kabeln während eines Gewitters
: DAS NETZKABEL DIENT ZUM TRENNEN DER
iv
Page 5
KLASSE 1 GERÄTE
DIESE GERÄTE MÜSSEN GEERDET SEIN. Der Netzstecker darf nur mit einer vorschriftsmäßig geerdeten Steckdose verbunden werden. Ein unvorschriftsmäßiger Anschluß kann das Metallgehäuseteile unter gefährliche elektrische Spannungen setzen.
NETZKABEL
Das Netzkabel sollte eine maximale Länge von 4,5 Metern, einen Nennwert von mindestens 6 A und 250 V haben, aus HAR-Material hergestellt und mit einer gepreßten, IEC 320 entsprechenden, Anschlußverbindung an einem Ende, und am anderen Ende mit einem im Land des Endverbrauchers geprüften Stecker ausgestattet sein.
MONTAGEANWEISUNGEN VORSICHT
worden. Das Gerät darf NICHT OHNE Gebrauch eines dafür entworfenen Allied Telesyn-Vertikalmontagegestells in VERTIKALER POSITION montiert werden.
VORSICHT
zum Kühlen freien Zugang zur Raumluft haben.
VORSICHT
Allied Telesyn-Vertikalmontagegestells.
BETRIEBSTEMPERATUR
Dieses Produkt wurde für den Betrieb in einer Umgebungstemperatur von nicht mehr als 40˚ C entworfen.
ALLE LÄNDER:
Vorschriften entsprechen.
: Diese Modelle sind für Betrieb in horizontaler Position entworfen
: Die Entlüftungsöffnungen dürfen nicht versperrt sein und müssen
: Die Gummifüße NICHT ENTFERNEN, außer bei Gebrauch des
Installation muß örtlichen und nationalen elektrischen
Radiofrekvens forstyrrelsesemission ADVARSEL:
Bliver det tilfældet, påkræves brugeren muligvis at tage tilstrækkelige foranstaltninger.
Immunitet:
Disse produkter er blevet sikkerhedstestet af UL til Standard 1950, CSA til CSA 950 og af TUV til EN60950.
SIKKERHED ELEKTRISKE FORHOLDSREGLER ADVARSEL: RISIKO FOR ELEKTRISK STØD
For at forebygge ELEKTRISK stød, undlad at åbne apparatet. Der er ingen indre dele, der kan repareres af brugeren. Denne enhed indeholder LIVSFARLIGE STRØMSPÆNDINGER og bør kun åbnes af en uddannet og kvalificeret tekniker. For at undgå risiko for ELEKTRISK STØD, afbrydes den elektriske strøm til produktet, før LAN-kablerne monteres eller afmonteres.
FARE UNDER UVEJR
FARE: UNDLAD at arbejde på udstyr eller KABLER i perioder med LYNAKTIVITET.
ADVARSEL
STRØMMEN. SKAL STRØMMEN TIL APPARATET AFBRYDES, tages ledningen ud af stikket.
INSTALLATION ELEKTRISK
Dette apparat vil automatisk tilpasse sig enhver spænding indenfor de værdier, der er angivet på etiketten.
I et hjemligt miljø kunne dette produkt forårsage radio forstyrrelse.
EN50082-1
: DEN STRØMFØRENDE LEDNING BRUGES TIL AT AFBRYDE
—AUTOMATISK SPÆNDINGSREGULERING
: EN55022 Klasse A
v
Page 6
ELEKTRISK—KLASSE 1-UDSTYR
DETTE UDSTYR KRÆVER JORDFORBINDELSE. Stikket skal være forbundet med en korrekt installeret jordforbunden stikkontakt. En ukorrekt installeret stikkontakt kan sætte livsfarlig spænding til tilgængelige metaldele.
ELEKTRISK
Anvend ledning af maksimum 4,5 meters længde, med en kapacitet på minimum 6 amp., 250 v, bestående af en IEC 320 connector med indstøbt HAR ledning i den ene ende og et stik i den anden ende godkendt der er af myndighederne i brugerlandet.
INSTRUKTIONER FOR OPSTILLING ADVARSEL
(vandret). VERTIKAL OPSTILLING (lodret) må IKKE FORETAGES uden brug af et Allied Telesyn vertikalt monteringsstel konstrueret til dette formål.
ADVARSEL
omgivende luft i rummet for afkøling.
ADVARSEL
anvendes et Allied Telesyn vertikalt monteringsstel.
BETJENINGSTEMPERATUR
Dette apparat er konstrueret til en omgivende temperatur på maksimum 40 grader C.
ALLE LANDE:
national lovgivning for elektriske installationer.
—LEDNING
: Disse modeller er konstrueret til at betjenes i HORISONTAL position
: Ventilationsåbninger må ikke blokeres og skal have fri adgang til den
: UNDLAD at fjerne gummisoklerne fra apparatet, med mindre der
Installation af produktet skal ske i overensstemmelse med lokal og
RFI Emissie: WAARSCHUWING:
welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen.
Immuniteit:
De veiligheid van deze produkten is door UL getest volgens norm 1950, CSA tot CSA 950 en door TUV volgens EN60950.
VEILIGHEID WAARSCHUWINGEN MET BETREKKING TOT ELEKTRICITEIT WAARSCHUWING
Gelieve het deksel niet te verwijderen, teneinde ELEKTRISCHE schokken te voorkomen. Binnenin bevinden zich geen onderdelen die door de gebruiker kunnen worden onderhouden. Dit toestel staat onder GEVAARLIJKE SPANNING en mag alleen worden geopend door een daartoe opgeleide en bevoegde technicus. Om het gevaar op ELEKTRISCHE SCHOKKEN te vermijden, moet u het toestel van de stroombron ontkoppelen alvorens de LAN-kabels te koppelen of ontkoppelen.
GEVAAR VOOR BLIKSEMINSLAG GEVAAR
WAARSCHUWING
STROOMKABEL TE ONTKOPPELEN. OM HET TOESTEL STROOMLOOS TE MAKEN: de stroomkabel ontkoppelen.
INSTALLATIE ELEKTRISCH
Dit toestel past zich automatisch aan elke spanning aan, tussen de waarden op het label vermeld.
ELEKTRISCHE—TOESTELLEN VAN KLASSE 1
DIT TOESTEL MOET GEAARD WORDEN. De stekker moet aangesloten zijn op een juist geaarde contactdoos. Een onjuist geaarde contactdoos kan de metalen onderdelen waarmee de gebruiker eventueel in aanraking komt onder gevaarlijke spanning stellen.
EN55022 Klasse A
Binnenshuis kan dit product radiostoring veroorzaken, in
EN50082-1
: GEVAAR VOOR ELEKTRISCHE SCHOKKEN
: NIET aan toestellen of KABELS WERKEN bij BLIKSEM.
: HET TOESTEL WORDT UITGESCHAKELD DOOR DE
—AUTOMATISCHE AANPASSING VAN DE SPANNING
vi
Page 7
ELEKTRISCHE
Gebruik een elektrisch snoer, maximum 4,5 meter lang, berekend voor ten minste 6 ampère, 250 V, uit HAR vervaardigd, met aan het ene uiteinde een gevormde IEC 320 stekker en aan het andere uiteinde een stekker die goedgekeurd is door het land waar het toestel zal worden gebruikt.
MONTAGE-INSTRUCTIES WAARSCHUWING
HORIZONTALE stand. VERTICALE MONTAGE mag NIET UITGEVOERD WORDEN, tenzij een daartoe speciaal ontworpen Allied Telesyn chassis voor verticale montage wordt gebruikt.
WAARSCHUWING
omgevingslucht ongehinderd toelaten voor afkoeling.
WAARSCHUWING
behalve wanneer een chassis voor vertikale montage van Allied Telesyn wordt gebruikt.
BEDRIJFSTEMPERATUUR
De omgevingstemperatuur voor dit produkt mag niet meer bedragen dan 40 graden Celsius.
ALLE LANDEN:
elektrische voorschriften.
—SNOEREN
: Deze modellen zijn ontworpen om te werken in
: De ventilatiegaten mogen niet worden gesperd en moeten de
: De rubberen voetjes NIET van het produkt LOSMAKEN
het toestel installeren overeenkomstig de lokale en nationale
NORMES: Emission d'interférences radioélectriques: MISE EN GARDE:
des interférences radioélectriques. Auquel cas, l'utilisateur devra prendre les mesures adéquates.
Immunité:
La sécurité de ces matériels a été testée par UL conformément à la norme UL 1950, CSA à CSA 950 et par TUV conformément à la norme EN60950.
SECURITE INFORMATION SUR L’ELECTRICITE AVERTISSEMENT: DANGER D’ELECTROCUTION
Pour empêcher les dangers d’ELECTROCUTION, ne pas enlever le couvercle. L’équipement ne contient aucun élément réparable par l’utilisateur. Cet appareil comprend des TENSIONS DANGEREUSES et ne doit être ouvert que par un technicien dûment qualifié. Pour éviter tout risque d’ELECTROCUTION, débrancher l’appareil de la prise de courant avant de connecter ou de déconnecter les câbles LAN.
DANGER DE FOUDRE DANGER
d’activité orageuse.
ATTENTION
POUR COUPER L’ALIMENTATION DE L’APPAREIL, débranchez le cordon.
INSTALLATION ELECTRICITE—REGLAGE DE TENSION AUTOMATIQUE
Ce produit peut s’ajuster automatiquement sur n’importe quelle tension comprise dans la plage indiquée sur le label.
ELECTRICITE—EQUIPEMENT DE CLASSE 1
CET APPAREIL DOIT ETRE MIS A LA TERRE. La prise de courant doit être branchée dans une prise femelle correctement mise à la terre. Sinon, des tensions dangereuses risqueraient d’atteindre les pièces métalliques accessibles à l’utilisateur.
ce produit est conforme aux normes de suivantes :
EN55022 Classe A
dans un environnement domestique, ce produit peut provoquer
EN50082 - 1
: NE PAS MANIER l’équipement ou les CABLES pendant les périodes
: LE CORDON D’ALIMENTATION SERT DE MISE HORS CIRCUIT
vii
Page 8
ELECTRICITE
Utiliser un cordon secteur de 4,5 mètres de long maximum, calibré à 6 ampères minimum, 250V, et fabriqué en câblage HAR avec connecteur IEC 32C moulé à une extrémité et à l’autre extrémité, une prise de courant mâle répondant aux normes du pays d’utilisation.
INSTRUCTIONS DE MONTAGE ATTENTION
L’appareil NE DOIT PAS être utilisé en MONTAGE VERTICAL sans employer un châssis de montage vertical Allied Telesyn conçu à cet effet.
ATTENTION
ambiant de circuler librement pour le refroidissement.
ATTENTION
d’utiliser un châssis de montage vertical Allied Telesyn.
TEMPERATURE DE FONCTIONNEMENT
Ce produit est capable de tolérer une température ambiante maximum de 40 degrés Celsius
POUR TOUS PAYS:
nationales et locales.
—INFORMATION SUR LE CORDON
: Ces modèles sont destiné à fonctionner en position horizontale.
: Ne pas bloquer les fentes d’aération, ce qui empêcherait l’air
: NE PAS ôter les pattes d’attache en caoutchouc du produit, à moins
Installer le produit conformément aux normes électriques
Radioaaltojen häirintä: VAROITUS:
missä tapauksessa laitteen käyttäjän on mahdollisesti ryhdyttävä tarpeellisiin toimenpiteisiin.
Kestävyys:
UL on turvatestannut nämä tuotteet Standard 1950 mukaisesti, CSA standardin CSA 950 mukaisesti ja TUV standardin EN60950 mukaisesti.
TURVALLISUUS SÄHKÖÖN LIITTYVIÄ HUOMAUTUKSIA VAROITUS: SÄHKÖISKUVAARA
Estääksesi SÄHKÖISKUN älä poista kantta. Sisällä ei ole käyttäjän huollettavissa olevia osia. Tämä laite sisältää VAARALLISIA JÄNNITTEITÄ ja sen voi avata vain koulutettu ja pätevä teknikko. Välttääksesi SÄHKÖISKUN mahdollisuuden katkaise sähkövirta tuotteeseen ennen kuin liität tai irrotat paikallisverkon (LAN) kaapelit.
SALAMANISKUVAARA HENGENVAARA
SALAMOINNIN AIKANA.
HUOMAUTUS
VIRTA KATKAISTAAN irrottamalla virtajohto.
ASENNUS SÄHKÖ—AUTOMAATTINEN JÄNNITTEENSÄÄTÖ
Tämä tuote säätää automaattisesti mihin tahansa jännitteeseen ohjetarrassa annettujen arvojen välillä.
SÄHKÖ—TYYPPILUOKAN 1 LAITTEET
TÄMÄ LAITE TÄYTYY MAADOITTAA. Pistoke täytyy liittää kunnollisesti maadoitettuun pistorasiaan. Virheellisesti johdotettu pistorasia voi altistaa metalliosat vaarallisille jännitteille.
SÄHKÖ—JOHTOON LIITTYVÄ HUOMAUTUS
Käytä seuraavanlaista virtajohtoa: maksimipituus 4,5 metriä, minimiteho 6 ampeeria, 250 V, valmistettu HAR-johdostosta, muovattu IEC 320 -liitin toisessa päässä ja käyttömaassa hyväksytty pistoke toisessa päässä.
Kotiolosuhteissa tämä laite voi aiheuttaa radioaaltojen häiröitä,
EN50082-1
: VIRTAJOHTOA KÄYTETÄÄN VIRRANKATKAISULAITTEENA.
EN55022 Luokka A
: ÄLÄ TYÖSKENTELE laitteiden tai KAAPELEIDEN KANSSA
viii
Page 9
ASENNUSSOHJEET HUOMAUTUS
PYSTYASENNUSTA EI SAA TEHDÄ ilman Allied Telesyn -pystykiinnitysalustaa, joka on suunniteltu tähän tarkoitukseen.
HUOMAUTUS
ympäröivään huoneilmaan, jotta ilmanvaihto tapahtuisi.
HUOMAUTUS
pystykiinnitysalusta ole käytössä.
KÄYTTÖLÄMPÖTILA
Tämä tuote on suunniteltu ympäröivän ilman maksimilämpötilalle 40° C.
KAIKKI MAAT:
sähköturvallisuusmääräysten mukaisesti.
: Nämä mallit on suunniteltu käytettäviksi VAAKA-asennossa.
: Ilmavaihtoreikiä ei pidä tukkia ja niillä täytyy olla vapaa yhteys
: ÄLÄ irroita kumijalkoja tuotteesta, ellei Allied Telesyn-
Asenna tuote paikallisten ja kansallisten
Emissione RFI (interferenza di radiofrequenza): AVVERTENZA:
interferenza. In questo caso potrebbe richiedersi all'utente di prendere gli adeguati provvedimenti.
Immunità:
Questi prodotti sono stati sottoposti a collaudi di sicurezza dai seguenti enti: dalla UL in conformità allo standard 1950, dalla CSA in conformità allo standard CSA 950 e dal TUV in conformità allo standard EN60950.
NORME DI SICUREZZA AVVERTENZE ELETTRICHE ATTENZIONE: PERICOLO DI SCOSSE ELETTRICHE
Per evitare SCOSSE ELETTRICHE non asportare il coperchio. Le componenti interne non sono riparabili dall’utente. Questa unità ha TENSIONI PERICOLOSE e va aperta solamente da un tecnico specializzato e qualificato. Per evitare ogni possibilità di SCOSSE ELETTRICHE, interrompere l’alimentazione del dispositivo prima di collegare o staccare i cavi LAN.
PERICOLO DI FULMINI PERICOLO
PRECIPITAZIONI TEMPORALESCHE.
ATTENZIONE
DI DISATTIVAZIONE. PER TOGLIERE LA CORRENTE AL DISPOSITIVO staccare il cavo di alimentazione.
INSTALLAZIONE ELETTRICITÀ
Questo prodotto regolerà automaticamente la tensione ad un valore compreso nella gamma indicata sull’etichetta.
ELETTRICITÀ
QUESTO DISPOSITIVO DEVE AVERE LA MESSA A TERRA. La spina deve essere inserita in una presa di corrente specificamente dotata di messa a terra. Una presa non cablata in maniera corretta rischia di scaricare una tensione pericolosa su parti metalliche accessibili.
ELETTRICITÀ
Usare un cavo della lunghezza massima di metri 4,5, con capacità minima di 6 A, 250 V, di filo HAR, dotato di connettore stampato IEC 320 ad un’estremità e di spina approvata dal paese di destinazione all’altra.
in ambiente domestico questo prodotto potrebbe causare radio
EN50082-1
: NON LAVORARE sul dispositivo o sui CAVI durante
: IL CAVO DI ALIMENTAZIONE È USATO COME DISPOSITIVO
—REGOLAZIONE AUTOMATICA DELLA TENSIONE
—DISPOSITIVI DI CLASSE 1
—AVVERTENZA SUL CAVO
EN55022 Classe A
ix
Page 10
ISTRUZIONI PER IL MONTAGGIO ATTENZIONE
ORIZZONTALE. NON È POSSIBILE EFFETTUARE IL MONTAGGIO VERTICALE senza utilizzare l’apposito telaio per il montaggio verticale Allied Telesyn.
ATTENZIONE
ricircolo dell’aria ambiente per il raffreddamento.
ATTENZIONE
utilizzi il telaio Allied Telesyn per il montaggio verticale.
TEMPERATURA DI FUNZIONAMENTO
Questo prodotto è concepito per una temperatura ambientale massima di 40 gradi centigradi.
TUTTI I PAESI:
elettriche nazionali.
: questi modelli sono concepiti per il funzionamento in posizione
: le prese d’aria non vanno ostruite e devono consentire il libero
: NON staccare il piedino in gomma dal prodotto tranne qualora si
installare il prodotto in conformità alle vigenti normative
RFI stråling: ADVARSEL:
forårsake radioforstyrrelse. Hvis dette skjer, må brukeren ta de nødvendige forholdsregler.
Immunitet:
Disse produktene er blitt sikkerhetstestet av UL i forhold til standard 1950, CSA i forhold til CSA 950, og av TUV i forhold til EN60950.
SIKKERHET ELEKTRISKE MEDDELELSE ADVARSEL: FARE FOR ELEKTRISK SJOKK
For å unngå ELEKTRISK sjokk, må dekslet ikke tas av. Det finnes ingen deler som du kan bruke på innsiden. Denne enheten inneholder FARLIGE SPENNING, og må kun åpnes av en opplært, kvalifisert tekniker. For å unngå muligheten av ELEKTRISK SJOKK, må den elektriske strømmen til produktet være av når du slår LAN-ledninger av og på.
FARE FOR LYNANTENNELSE FARE
gang.
FORSIKTIG
DU VIL DEAKTIVISERE UTSTYRET, må du fjerne strømledningen.
INSTALLASJON ELEKTRISK
Dette produktet vil automatisk bli tilpasset hvilken som helst strøminnstilling i de områdene som vises på etiketten.
ELEKTRISKE—TYPE 1. KLASSE UTSTYR DETTE UTSTYRET MÅ JORDES
korrekt jordet grunnstøpselkontakt. En støpselkontakt som ikke er jordet på rett måte, kan tilføre farlig spenning til lett tilgjengelige metalldeler.
ELEKTRISKE
Bruk en strømledning av maksimal størrelse 4,5 m i lengde, vurdert for minst av 6 amp, 250V, fremstilt av HAR ledning IEC 320 koplingsstykke på den ene kanten og på den andre kanten en plugg som har blitt godkjent i det landet hvor den siste brukeren befinner seg.
BRUKSANVISNINGER FOR MONTERING FORSIKTIG
VERTIKAL MONTERING må IKKE UTFØRES uten bruk av et Allied Telesyn vertikal monteringschassis som er spesiallaget til dette formål.
EN55022 Klasse A
Hvis dette produktet benyttes til privat bruk, kan produktet
EN50082-1
: MÅ IKKE BRUKES på utstyr eller ledninger mens LYN-AKTIVITET er i
: STRØMLEDNINGEN BRUKES TIL Å SLÅ APPARATET AV. HVIS
—AUTO SPENNINGSTILPASSING
. Strømkontakten må være tilkoplet en
—MEDDELELSE OM LEDNINGER
: Disse modellene er beregnet til bruk i HORISONTAL stilling.
x
Page 11
FORSIKTIG: MEKANISK LASTNING
utføres på slik måte at ingen farlige situasjoner oppstår som en følge av ujevn lastning.
FORSIKTIG
romtemperatur for avkjøling.
FORSIKTIG
Telesyn vertikal monteringschassis er i bruk.
DRIFTSTEMPERATUR
Dette produktet har blitt fremstilt til bruk med maksimum romtemperatur på 40 grader celsius.
ALLE LAND:
elektriske koder.
: Luftventilene må ikke blokkeres og må ha fri tilgang til luft med
: Gummiføttene må IKKE fjernes fra produktet med mindre en Allied
Produktet må installeres i samsvar med de lokale og nasjonale
Installering av utstyret på hyllen må
Emissão de interferência de radiofrequência: AVISO:
Num ambiente doméstico este produto pode causar interferência na radiorrecepção e, neste caso, pode ser necessário que o utente tome as medidas adequadas.
Imunidade:
Estes produtos foram testados pela UL quanto a aspectos de segurança no Padrão 1950, CSA a CSA 950, e pela TUV no EN60950.
SEGURANÇA AVISOS SOBRE CARACTERÍSTICAS ELÉTRICAS ATENÇÃO:
Para evitar CHOQUE ELÉTRICO, não retire a tampa. Não contém peças que possam ser consertadas pelo usuário. Este aparelho contém VOLTAGENS PERIGOSAS e só deve ser aberto por um técnico qualificado e treinado. Para evitar a possibilidade de CHOQUE ELÉTRICO, desconecte o aparelho da fonte de energia elétrica antes de conectar e desconectar os cabos da LAN.
PERIGO DE CHOQUE CAUSADO POR RAIO PERIGO:
suscetíveis de QUEDAS DE RAIO.
CUIDADO
DISPOSITIVO DE DESCONEXÃO. PARA DESELETRIFICAR O EQUIPAMENTO desconecte o cabo de alimentação.
INSTALAÇÃO ELÉTRICO
Este produto ajustar-se-á automaticamente a qualquer voltagem que esteja dentro dos limites indicados no rótulo.
ELÉTRICO—EQUIPAMENTOS DO TIPO CLASSE 1
DEVE SER FEITA LIGAÇÃO DE FIO TERRA PARA ESTE EQUIPAMENTO. O plugue deve ser conectado a uma tomada com ligação de fio terra. Tomadas sem ligação de fio terra podem transmitir voltagens perigosas a peças metálicas expostas.
ELÉTRICO
Use cabo de alimentação com comprimento máximo de 4, 5 metros, com uma capacidade mínima de 6 amp e 250 V, fabricado de material para cabo HAR com conector moldado IEC 320 em uma extremidade e, na outra extremidade, um plugue aprovado para uso no país em questão .
EN50082-1
PERIGO DE CHOQUE ELÉTRICO
NÃO TRABALHE no equipamento ou nos CABOS durante períodos
: O CABO DE ALIMENTAÇÃO É UTILIZADO COMO UM
—AJUSTE AUTOMÁTICO DE VOLTAGEM
—AVISO SOBRE O CABO DE ALIMENTAÇÃO
EN55022 Classe A
xi
Page 12
INSTRUÇÕES DE INSTALAÇÃO CUIDADO: Este modelos foram projetados para funcionar na posição
HORIZONTAL. NÃO DEVE SER EFETUADA INSTALAÇÃO VERTICAL sem o uso de um chassis de montagem vertical Allied Telesyn projetado para este fim específico.
CUIDADO: CARREGAMENTO - O equipamento deverá ser montado no suporte de montagem de forma a não causar perigo devido a carregamento não-uniforme.
CUIDADO: As entradas de ar não devem ser bloqueadas e devem ter acesso livre ao ar ambiente para arrefecimento adequado do aparelho.
CUIDADO: NÃO RETIRE os calços de borracha do produto a menos que esteja sendo usado um chassis de montagem vertical Allied Telesyn.
TEMPERATURA DE FUNCIONAMENTO
Este produto foi projetado para uma temperatura ambiente máxima de 40 graus centígrados.
TODOS OS PAÍSES: Instale o produto de acordo com as normas federais e locais para instalações elétricas.
Emisión RFI: EN55022 Clase A ADVERTENCIA: en un entorno doméstico, este producto puede causar
radiointerferencias, en cuyo caso, puede requerirse del usuario que tome las medidas que sean convenientes al respecto.
Inmunidad: EN50082-1 La seguridad de estos productos ha sido probada por UL conforme con la Norma
1950, CSA a CSA 950, y por TUV conforme con EN60950.
SEGURIDAD AVISOS ELECTRICOS ADVERTENCIA: PELIGRO DE ELECTROCHOQUE
Para evitar un ELECTROCHOQUE, no quite la tapa. No hay ningún componente en el interior al cual puede prestar servicio el usuario. Esta unidad contiene VOLTAJES PELIGROSOS y sólo deberá abrirla un técnico entrenado y calificado. Para evitar la posibilidad de ELECTROCHOQUE desconecte la corriente eléctrica que llega al producto antes de conectar o desconectar los cables LAN.
PELIGRO DE RAYOS PELIGRO: NO REALICE NINGUN TIPO DE TRABAJO O CONEXION en los
equipos o en LOS CABLES durante TORMENTAS DE RAYOS ATENCION: EL CABLE DE ALIMENTACION SE USA COMO UN
DISPOSITIVO DE DESCONEXION. PARA DESACTIVAR EL EQUIPO, desconecte el cable de alimentación.
INSTALACION ELECTRICO—AUTO-AJUSTE DE TENSION
Este producto se ajustará automáticamente a cualquier tensión entre los valores máximos y mínimos indicados en la etiqueta.
ELECTRICO—EQUIPO DEL TIPO CLASE 1
ESTE EQUIPO TIENE QUE TENER CONEXION A TIERRA. El cable tiene que conectarse a un enchufe con tierra debidamente instalado. Un enchufe que no está correctamente instalado podría ocasionar tensiones peligrosas en las partes metálicas están expuestas.
ELECTRICO—ADVERTENCIA SOBRE EL CABLE Use un cable eléctrico con un máximo de 4, 5 metros de largo, con una capacidad mínima de 6 amperios, 250 V, hecho de cable HAR, con el conector moldeado IEC 320 en un extremo y con un enchufe que está aprobado por el país de uso final en el otro.
xii
Page 13
INSTRUCCIONES DE MONTAJE
ATENCION: Estos modelos están diseñados para operar en posición HORIZONTAL. NO SE DEBEN MONTAR VERTICALMENTE sin el uso de un chasis de montaje vertical de Allied Telesyn que se ha diseñado para este fin.
ATENCION: CARGA MECANICA - El montaje del equipo en el bastidor debe realizarse de manera tal que no cause una condición peligrosa debido a la distribución desigual del peso.
ATENCION: Las aberturas para ventilación no deberán bloquearse y deberán tener acceso libre al aire ambiental de la sala para su enfriamiento.
ATENCION: NO separe las patas de goma del producto a menos que se esté usando un chasis de montaje vertical de Allied Telesyn.
TEMPERATURA REQUERIDA PARA LA OPERACIÓN
Este producto está diseñado para una temperatura ambiental máxima de 40 grados C.
PARA TODOS LOS PAÍSES: Monte el producto de acuerdo con los Códigos Eléctricos locales y nacionales.
Radiostörning: EN55022 Klass A VARNING: Denna produkt kan ge upphov till radiostörningar i hemmet, vilket
kan tvinga användaren till att vidtaga erforderliga åtgärder. Immunitet: EN50082-1 Dessa produkter har säkerhetstestats av UL i enlighet med Standard 1950, av CSA
i enlighet med CSA 950, och av TUV i enlighet med EN60950.
SÄKERHET TILLKÄNNAGIVANDEN BETRÄFFANDE ELEKTRICITETSRISK: RISK FÖR ELEKTRISK STÖT
För att undvika ELEKTRISK stöt, ta ej av locket. Det finns inga delar inuti som behöver underhållas. Denna apparat är under HÖGSPÄNNING och får endast öppnas av en utbildad kvalificerad tekniker. För att undvika ELEKTRISK STÖT, koppla ifrån produktens strömanslutning innan LAN-kablarna ansluts eller kopplas ur.
FARA FÖR BLIXTNEDSLAG FARA: ARBETA EJ på utrustningen eller kablarna vid ÅSKVÄDER.
VARNING: NÄTKABELN ANVÄNDS SOM STRÖMBRYTARE FÖR ATT
KOPPLA FRÅN STRÖMMEN, dra ur nätkabeln.
INSTALLATION ELEKTRISKT—AUTOMATISK SPÄNNINGSJUSTERING
Denna produkt justeras automatiskt till alla spänningar inom omfånget som indikeras på produktens märkning.
ELEKTRISKT—TYP KLASS 1 UTRUSTNING
DENNA UTRUSTNING MÅSTE VARA JORDAD. Nätkabeln måste vara ansluten till ett ordentligt jordat uttag. Ett felaktigt uttag kan göra att närliggande metalldelar utsätts för högspänning. Apparaten skall anslutas till jordat uttag, när den ansluts till ett nätverk.
ELEKTRISKT—ANMÄRKNING BETRÄFFANDE KABELN
Använd en kabel med maximum längd 4,5 meter och minimum 6 amp nominal, 250V, av HAR kabelfabrikat med ett specialutformat IEC 320-kontaktdon i ena änden och i den andra en plugg som godkänts i landet där produkten används.
xiii
Page 14
MONTERINGSINSTRUKTIONER VARNING: Dessa modeller är konstruerade för användning i
HORISONTALLÄGE. VERTIKALMONTERING får EJ UTFÖRAS utan att ett Allied Telesyn specialkonstruerat vertikalt monteringschassi används.
VARNING: MEKANISK BELASTNING: Utrustningen ska installeras i chassit på så sätt att fara inte uppstår p g a ojämn belastning.
VARNING: Luftventilerna får ej blockeras och måste ha fri tillgång till omgivande rumsluft för avsvalning.
VARNING: Ta ej bort gummifötterna från produkten om inte ett Allied Telesyn vertikalt monteringschassi används.
DRIFTSTEMPERATUR
Denna produkt är konstruerad för rumstemperatur ej överstigande 40 grader Celsius.
ALLA LÄNDER: Installera produkten i enlighet med lokala och statliga bestämmelser för elektrisk utrustning.
xiv
Page 15

Table of Contents

Electrical Safety and Installation Requirements . . . . . . . . . . . . . . . . . .iii
About This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xix
Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xx
Contacting ATI Technical Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xx
Telephone and Fax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xx
Bulletin Board Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xx
Internet Mail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xxi
CompuServe Forum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxi
World Wide Web . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xxi
Chapter 1
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
AT-MR420TR Faceplates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Backbone Network Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
10Base2/AUI Backbone Port Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Backbone Enable Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Media Select Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Chapter 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Site Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Quick Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
RJ45 Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
AUI Network Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
BNC Network Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
LED Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Network Load Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Port Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Hub Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
System Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
xv
Page 16
Chapter 3
Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Four Media Connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
AC Power Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
10Base-T Network Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
AUI Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
BNC Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Twisted Pair (RJ45) Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Chapter 4
Topology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Standalone Topology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Cascade Topology. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
BNC Terminator Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Backbone Networks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
MDI/MDI-X Switch and Uplink Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
10Base5 Backbone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
10Base2 Backbone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Fiber Optic Backbone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Appendix A
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
The AT-MR420TR/AT-MR820TR Specifications . . . . . . . . . . . . . . . . . . . . . . . 31
Physical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Electrical Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Connector Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Diagnostic LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
10Base-T Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Straight-through Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Crossover Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
5 - 4 - 3 Rule. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Appendix B
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Appendix C
Technical Support Fax Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
xvi
Page 17
Appendix D
CentreCOM AT-MR420TR/AT-MR820TR Guide Feedback . . . . . . . . . 45
Appendix E
Where To Find Us . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Appendix F
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
xvii
Page 18
Page 19

About This Guide

This guide is written for system administrators who are responsible for configuring, monitoring, and maintaining a Local Area Network (LAN) of which Allied Telesyn’s AT-MR420TR and AT-MR820TR Micro Repeaters are components. This guide serves as an installation guide and reference guide for both products.
The contents of each chapter are described below:
Chapter 1, “Product Description,” provides an overview of the
AT-MR420TR/AT-MR820TR Micro Repeaters including the backbone network ports and switches.
Chapter 2, “Installation,” describes the site requirements,
quick installation as well as conventional installation procedures, connections, and LED Status Indicators.
Chapter 3, “Connectivity,” provides instructions associated
with the four media connectors and ports.
Chapter 4, “Topology,” describes uplink and cascading
capabilities in a backbone network topology as well as the MDI/ MDI-X and BNC Termination Switches.
Appendix A, “Technical Specifications,” includes specifications
and basic 10Base-T cabling pin assignments.
Appendix B, “Glossary,” provides a glossary of terms that are
product and industry specific to the AT-MR420TR/ AT-MR820TR.
Appendix C is a “Technical Support Fax Order.” Appendix D, “Guide Feedback,” offers a means to transmit your
comments and/or suggestions for improving the documentation.
Appendix E, “Index,” is an index to this guide. Appendix F, “Where To Find Us,” provides Technical Support
information.
xix
Page 20
About This Guide

Document Conventions

The following conventions are used in presenting information in this guide:
Note
A note provides additional information or describes the possible consequence of a specific action you can perform.

Contacting ATI Technical Support

If you are having problems with your AT-MR420TR/AT-MR820TR, you can contact ATI’s Technical Support staff by:
Telephone Bulletin board services Electronic mail via the Internet CompuServe forum
When you contact Technical Support, you should have the following information available:
Serial number of the AT-MR420TR/AT-MR820TR Power-up test codes, if any Diagnostic test codes, if any
Telephone and Fax
Refer to Appendix E on page 47 for a complete listing of Technical Support Telephone and Fax numbers.
Bulletin Board Services
A bulletin board is available. The number is:
206-483-7979
Modem settings for the bulletin board is: 8 bits; no parity; 1 stop bit.
xx
Page 21
AT-MR420TR and AT-MR820TR Installation Guide
The process is straightforward: Once the BBS is accessed, it requests that you register either as a new user or as a current user. It then provides instructions on the various features and functions available. This is followed by a list and description of all available technical notes and files that can be downloaded.
Internet Mail
You can send electronic mail via the Internet to:
tech_support@centre.com
CompuServe Forum
ATI has a forum on CompuServe. You can reach us by typing go allied at the CompuServe prompt (!).
World Wide Web
You can access Allied Telesyn at our Web Site using the following:
http: //www.alliedtelesyn.com
xxi
Page 22
Page 23
Chapter 1

Product Description

Overview
Allied Telesyn’s multiport AT-MR420TR/AT-MR820TR Micro Repeaters represent a compact, inexpensive solution for Local Area
Network (LAN) applications. AT-MR420TR/AT-MR820TR Micro Repeaters combine 10 Mbps of
10Base-T Ethernet connectivity with the same features and functionality of larger, more expensive repeaters. At the same time, they support full-length cable segments with the maximum number of supported devices allowed within IEEE standards.
While identical in structure, the AT-MR420TR Micro Repeater differs from the AT-MR820TR Micro Repeater in that the former has 4 Shielded/Unshielded Twisted Pair (STP/UTP) ports whereas the latter has 8 STP/UTP ports. You can use any one of the STP/UTP ports for connection to a 10 megabit Ethernet node using Category 3-5 STP/UTP cabling. The Uplink port provides cascading capabilities to the second 10Base-TX Ethernet hub.
AT-MR420TR Faceplates
Figure 1 and Figure 2, respectively show the front and back panel of the AT-MR420TR and AT-MR820TR Micro Repeaters. The front panel consists of eight Network Load LEDs indicating the percentage of network utilization, and 16 or 8 (depending on version) Link and Receive status LEDs for each network port. Three additional LEDs indicate Activity, Collision, and Power for the repeater itself.
1
Page 24
Product Description
Figure 1: AT-MR420TR and AT-MR820TR Front Panels
Figure 2: AT-MR420TR and AT-MR820TR Rear Panels
On the back panel are four/eight STP/UTP RJ45 network ports, including Port 4/8, an uplink port, as well as the 10Base5 and 10Base2 backbone network ports, Figure 1 and Figure 2 also show the three-pin AC power receptacle.
2
Page 25
AT-MR420TR and AT-MR820TR Installation Guide
Features
The AT-MR420TR/AT-MR820TR Micro Repeaters have incorporated the latest technologies, including a custom Application Specific Integrated Circuit (ASIC) and Surface Mount Technology (SMT). These result in enhanced functionality, increased reliability, improved performance, and lower cost.
The AT-MR420TR/AT-MR820TR Micro Repeaters have the following features:
IEEE 802.3 compliant 10Base-T and Ethernet Version 1.0 and 2.0 compatible AUI and a BNC ports for connectivity to a network backbone as
well as four/eight twisted pair cable connections
user-selectable AUI or BNC Backbone switch user-selectable Backbone Network Enable/Disable switch Network Load LEDs (network utilization) automatic packet regeneration, error detection and correction test link capability auto-partitioning and jabber lock-up protection status and diagnostic LEDs STP/UTP uplink port supported for network cascading
Packet Regeneration. Packet regeneration is a high-performance network feature that includes the regenerating of the packet preamble, retiming of data packets, and the extension of collision fragments.
Link Integrity. The IEEE 802.3 defined link integrity test function continually monitors the twisted pair cable to ensure link continuity of the receive pair between the user node and the repeater.
Auto-partitioning. Also known as segmentation, each segment is automatically partitioned whenever 32 consecutive collisions are seen on the segment. One valid packet will reset the segment and reconnect it.
Jabber Lock-up Protection. Jabber lock-up protects the repeater from being overrun with data packets by isolating segments with transmitted packets that exceed the maximum packet length. That is,
3
Page 26
Product Description
jabber lock-up automatically prevents transmitted data from reaching the repeater if the transmitted data time exceeds a specified duration (usually 5 ms).
Backbone Network Port
There are two user-selectable network media options which can be used to connect to a backbone network: 10Base2 and 10Base5.
These network ports are located on the back panel. See Figure 3.
Figure 3: Network Media Options
These media alternatives are:
10Base2 (Bayonet Nut Couple [BNC])
— 10Base2 requires a thin coaxial cable, RG58U, which is a 10
MHz baseband cable that uses BNC-series connectors. The cable must be terminated at both ends with 50 terminators and grounded at one end. Maximum segment length is 185 meters (606 ft.). Internal termination is provided via the BNC Terminator Switch. See Chapter 4 “BNC Terminator Switch” for details concerning this switch.
4
Page 27
AT-MR420TR and AT-MR820TR Installation Guide
10Base5 (Attachment Unit Interface [AUI])
— Located to the right of the BNC port, the 10Base5 network
port connects the repeater to the network using standard ( thick) Ethernet cable and AUI-series connectors. Alternatively, you can fit an Allied Telesyn 802.3 transceiver into this port for alternative media connections, for example fiber optics.
Although both network ports are always available, only one can be active at a time and, since there is no default port, you determine the active port by using the Backbone Enable and Media Select switches — both of which will be discussed next.
10Base2/AUI Backbone Port Switches
There are two user-selectable switches: a Backbone Enable and Media Select. See Figure 4.
Figure 4: Backbone Switches
5
Page 28
Product Description
Backbone Enable Switch
This dual-position switch allows you to activate the backbone network AUI and BNC ports.
When this switch is ON (default position), it is depressed below the surface of the chassis. The ON position (enabled) indicates that both 10Base2 and AUI ports have a backbone network capability.
Deactivating the switch to OFF (disabled) means that the switch is flush with the surface of the chassis. As a result, the ports are not capable of connecting to a backbone network.
Media Select Switch
The Media Select switch is only active after the Backbone Enable switch is activated. It functions as the name implies — you have the ability to determine the medium of connectivity to the network backbone: either the 10Base2 (BNC) port or the 10Base5 (AUI) port (but not both).
The default position is AUI (the switch is flush with the surface of the chassis).
The AUI port also allows you to attach an optional, inexpensive external micro transceiver for additional LAN connectivity using thinnet, twisted pair or fiber optic cable.
When the switch is pressed below the surface of the chassis, the 10Base2 port is selected. Notice that the 10Base2 backbone port also includes a user-selectable 50 terminator switch. The use of the terminator switch is discussed in Chapter 4.
6
Page 29
Chapter 2

Installation

Site Requirements

Ventilation

AT-MR420TR/AT-MR820TR Micro Repeaters have grilled openings on both sides for ventilation. Although they do not require an internal fan to aid in cooling, adequate ventilation is required. Ensure that the ventilation openings located on the sides of the chassis are never blocked.
Note
Maximum ambient operating temperature is 104o F (40o C).

Power

Be sure that the voltage and frequency is either 100-120 or 200-240 VAC and 60 or 50 Hz respectively. Since there is no external power switch, power is applied when the power cord is connected.
Note
For countries other than the United States and Canada: use a power cord that is rated at 6 amp, 250 VAC. Also note that this cord cannot exceed 4.6 meters (15 ft.) in length and must be made of HAR cordage with IEC fittings that are approved by the country of end use.
7
Page 30
Installation

Quick Installation

1. Carefully remove the AT-MR420TR/AT-MR820TR Micro Repeaters from their packaging materials. Keep the packing
materials until you have successfully installed the product.
2. Place them in a location with adequate ventilation and power receptacles.
3. Apply power by plugging in the AC cord and ensure that the POWER LED on the front panel is illuminated.
4. If you are connecting to a backbone network, prepare either the AUI or BNC cable for attachment.
5. Attach your 10Base-T STP/UTP cables, with RJ45 connectors to the 10Base-T ports. If the UPLINK port is not used for cascading, you may connect a standard 10Base-T cable to port 4/8.
6. If the AT-MR420TR/AT-MR820TR Micro Repeaters are to be connected to an external transceiver, attach a transceiver to the 15-pin AUI connector on the back panel. Ensure that the external transceiver has its Signal Quality Error (SQE)/Heartbeat Test function disabled. When power is applied to the AT-MR420TR/ AT-MR820TR Micro Repeaters, the external transceiver should also have power.
Note
Because of the default switch positions, you do not have to changes any switches.
8
Page 31
AT-MR420TR and AT-MR820TR Installation Guide

Connections

The AT-MR420TR/AT-MR820TR Micro Repeaters have the following connectors:
RJ45 AUI BNC

RJ45 Ports

Attach an RJ45 10Base-T STP/UTP cable to port 1. The respective segment LINK OK LED located on the front panel should light when the 10Base-T network adapter card in the device on the opposite end of the STP/UTP segment is operational. If not, check that the card on the opposite end of the STP segment is operational, then ensure that the proper cable is being used.
Attach a second 10Base-T STP RJ45 connector to 10Base-T network port 2. The port 2 LINK OK LED on the front panel should light, provided the 10Base-T device on the opposite end of the STP/UTP cable is operational.

AUI Network Port

Each AT-MR420TR/AT-MR820TR Micro Repeater has one AUI port to accommodate a 10Base5 (standard or thick Ethernet cable) connection to the network backbone using an AUI or convert the media type, for example fiber optics.

BNC Network Port

Each AT-MR420TR/AT-MR820TR Micro Repeater has one BNC port to accommodate a 10Base2 (cheapernet or thin Ethernet cable) connection to the network backbone.
9
Page 32
Installation

LED Status Indicators

The front panel indicators are grouped into the following categories:
Network Load Port Status Hub Status

Network Load Indicators

Eight Network Load LEDs indicating the percentage of network utilization, are located on the front panel. Figure 5 shows these LEDs.
Figure 5: Network Load Indicators

Port Status Indicators

Two Port Status indicators are associated with each 10Base-T (RJ45) network port. Located on the front panel of the repeater, these LEDs indicate whether the port is linked, receiving data, or both. See Figure 6.
10
Page 33
AT-MR420TR and AT-MR820TR Installation Guide
Note
A data packet is too fast for the human eye to distinguish on an LED, therefore the LEDs will not reflect real-time activity. The repeater artificially stretches the LED on time for easier observation.
Figure 6: Port Indicators
Each RJ45 repeater port has two LEDs — LINK OK and Receive:
LINK OK
— No light—Indicates typically a physical connection problem.
The device at the other end of the cable may be powered off, the cable may be loose or disconnected, or the cable has been wired incorrectly. Check the crossover cable.
— Green (Steady)—Indicates a valid link exists.
Receive
— Amber (Flashing)—Link is OK, port is not partitioned and
there is activity on the port. Brief flashes indicate low traffic levels.
In short, port status LEDs show the functionality of the port. If the LINK OK status light is green and the Receive status is flashing amber, a signal is being received and the segment attached to the port is functional.
11
Page 34
Installation
If there is no link light, there is no signal continuity.
Check that the attached Data Terminal Equipment (DTE) is ON and that the proper cable is being used.
If this check does not identify the problem, it may indicate that a repeater or the device connected to the port is faulty. Move the cable to the adjacent ports to further isolate the problem to the repeater or to the attached device. It may be necessary to change cables to isolate the fault to a particular cable.

Hub Status Indicators

Three Hub status LEDs at the far right of the front panel indicate the overall status of the repeater. Figure 7 shows the location of these indicators.
Figure 7: Hub Status LEDs
12
Page 35
AT-MR420TR and AT-MR820TR Installation Guide
Table 1: Hub Status LEDs
LED Color Description
Power green lights when AC power is applied Collision
1
amber flashes indicating an SQE or frame collisions on a
segment. This may be caused by an overloaded segment, faulty cable, or loose connection.
Activity green indicates that the repeater is functional and is
transmitting packets
1
Occasional collisions are normal in Ethernet networks. A constantly illuminated Collision
LED may indicate that there is a prt with excessive traffic problems. If the Collision LED is flashing steadily, and you are using an external transceiver on the AUI backbone port, make certain that the SQE/Heartbeat Test function is disabled. Repeaters do not function properly when the SQE/Heartbeat Test is active.

System Check

1. Check the LINK OK LED on the front panel for the first 10Base-T port that is connected. A steady green LED indicates continuity. A valid network connection must be made from the connected port to a host or workstation on another port.
2. After a successful connection, disconnect the active 10Base-T connector and connect it to the next successive port. Continue this process until all 10Base-T ports have been validated with good network connections.
3. Establish a connection from a device connected to port 1 to a device connected to port 2.
4. Once the connection between devices attached to ports 1 and 2 has been successfully established, remove the RJ45 connector from port 2 and connect it to each of the subsequent repeater’s 10Base-T ports, 3 through 4/8, to verify their functions.
5. If all ports test successfully, install the rest of the 10Base-T RJ45 connections and ensure that the LINK LED for each port is illuminated. Remember, the 10Base-T device on the opposite end of the STP/UTP cable must be operational.
13
Page 36
Installation
Note
The LINK LED validates the receive pair only. The opposite end of the STP segment is responsible for validating the transmit pair.
14
Page 37
Chapter 3

Connectivity

Four Media Connectors

This repeater has four types of ports and media connectors:
AC input power connector 10Base5 (AUI) network backbone port 10Base2 (BNC) network backbone port Four/Eight STP/UTP 10Base-T (RJ45) ports
These four types of connecting media are described in the following sections.

AC Power Connector

While it is common to use dedicated power circuits or power conditioners to supply power to network devices, the source must be able to provide AC power at 100-120 VAC, 0.5A, and/or 200-240VAC,
0.25A, and 60/50 Hz (for North American models). This aids in isolating
the network equipment from electrical power “noise.” The AC power connector is located on the back panel and provides
connectivity for an internal power supply. It accepts 100-120 or 200-240 VAC from the rear IEC power entry port. The three-pin power receptacle, shown in Figure 8, requires a three-pin male connector.
15
Page 38
Connectivity
Figure 8: Power Connector
16
Page 39
AT-MR420TR and AT-MR820TR Installation Guide

10Base-T Network Specifications

Table 2 provides an overview of the IEEE 802.3 specifications for 10Base-T network configurations using thick, thin, and twisted-pair wiring.
Table 2: IEEE 802.3 Network Specifications
10Base-T 10Base2 10Base5
Media Twisted Pair
Cable
Thin Coaxial
Cable
Thick Coaxial Cable
Topology Star, Tree Bus Bus
External Devices Network
Adapter Card
Network
Adapter Card
Network Adapter
Card and External
Transceiver
Maximum
Segment Length
Maximum
100 meters
(328 ft.)
185 meters
(605 ft.)
_ 30 100
457 meters
(1,500 ft.)
Devices per
Segment
Maximum
_ 1,024 1,024
Devices per
Network

AUI Port

The AUI port is a 15-pin D-sub female connector, located on the back panel. This AUI backbone port connects the repeater to the network using a standard AUI drop cable. See Figure 9. Alternatively, you can fit any of a variety of Allied Telesyn’s 802.3 transceivers into this port should you select a different medium such as fiber optics.
17
Page 40
Connectivity
Figure 9: AUI Network Port
10Base5 (Thick) Ethernet Cable. When configuring 10Base5 coax
segments, IEEE 802.3 specifications allow a maximum of 100 MAU attachments, spaced at multiples of 2.5 meters (8.2 ft.) measured accurately from the cable end (50terminator included). The 10Base5 cable segment should not exceed 500 meters (1,640 ft.). Worst-case “end-to-end” propagation delay of a 10Base5 coax segment is 2165 ns. Propagation delay of 10Base5 Ethernet coax is calculated at 4.33 ns/ meter. Both ends of the segment must be terminated with a 50 termination with a power rating of 0.5 watts or greater. Earth grounding of the segment shield is allowed at only one point on the cable.
AUI Drop Cables. AUI or drop cables should not exceed 50 meters (164 ft.) each. Attachments may be made only to the cable ends at the 15-pin D-shell connector. AUI cables may have a maximum 257 ns propagation delay, as used for computing the worst-case propagation delay of a cable system. AUI cable propagation delay is approximately
18
Page 41
AT-MR420TR and AT-MR820TR Installation Guide
5.13 ns/meter. This cable internally consists of four shielded twisted
pair wires with an overall shield and drain wire; a 15-pin D-shell male connector at one end and a 15-pin D-shell female connector at the other end. Cable impedance is nominally 78 . The AUI cable typically connects a transceiver attached to a coaxial segment to a DTE (workstation).

BNC Port

10Base2 requires an RG58U, thin coaxial cable. This cable is a 10 Mbits/sec baseband with 50 impedance. See Figure 10. Connected with BNC-series connectors, the maximum segment length is 185 meters (606 ft.).
10Base2 (Thin) Ethernet. When configuring thin coax segments, IEEE
802.3 specifications allow 30 or fewer MAUs per cable segment spaced
at no less than 0.5 meter (1.64 ft.). The 10Base2 cable length cannot exceed 185 meters (606 ft.) per 10Base2 cable segment. The worst case propagation delay for a 185 meters (606 ft.) thin Ethernet segment is
950.9 ns. The propagation delay for 10Base2 Ethernet cable is 5.14 ns/
meter. Both ends of the segment must be terminated with a 50 termination with a power rating of 0.5 watts or greater. The AT-MR420TR and AT-MR820TR repeaters provide internal 50 terminator with a slide switch. Earth grounding of the segment shield is required at only one point on the cable.
Figure 10: BNC-T Connector
19
Page 42
Connectivity

Twisted Pair (RJ45) Connector

Figure 11 shows a twisted pair cable with RJ45 connectors. For a 10Base-T link between a repeater and a Medium Attachment Unit (MAU) or Network Interface Controller (NIC), the cable is wired straight through.
Figure 11: RJ45 Connector
10Base-T STP cables can be up to 100 meters (328 ft.) in length. The cable should be 22 to 26 AWG TP wire with 100 impedance and rated at Category 3, 4, or 5. The AT-MR420TR/AT-MR820TR Micro Repeaters use RJ45 modular connectors for 10Base-T connections.
10Base-T Cable. The AT-MR420TR/AT-MR820TR Micro Repeaters support full-length, fully repeated transmission and maximum node attachments which, for the STP/UTP link, enables transmissions to 100 meters (328 ft.).
A serious problem exists concerning identification of modular cable. There are various grades of voice-quality and data-quality cables available. These can appear to be similar, but their high-speed data transmission characteristics are significantly different. Some suppliers have sold purportedly data-quality cables manufactured with voice­quality cabling.
If any voice-quality cabling is used in a 10Base-T network system, data movement is slow, collision-prone or non-existent. To confuse the issue, the Link indicator on the interface usually indicates a valid link.
20
Page 43
AT-MR420TR and AT-MR820TR Installation Guide
10Base-T connections require Category 3, 4, or 5. In most cases, if a cable type is flat, it is typically untwisted and can cause problems. Generally, cable that is more or less round in section, gives better results.
Hub to MAU Wiring. The most typical TP cable for the AT-MR420TR/ AT-MR820TR Micro Repeaters is TP Hub to TP transceiver Data
Terminal Equipment (DTE). To configure your own cables, see Appendix A, “Technical
Specifications.”
21
Page 44
Page 45
Chapter 4

Topology

Standalone Topology
Figure 12 shows a standalone topology. Four workstations are connected directly to the repeater through the repeater’s RJ45 ports.
100 Meters
TP cable
wired 
Pin to Pin
10BaseT
Tranciever
Figure 12: AT-MR420TR Standalone Topology
Cascade Topology
A shared Ethernet network can be expanded by interconnecting repeaters (cascading) through the UTP ports. Figure 13 shows a cascaded topology using four repeaters which is the maximum number of micro repeaters and nodes in a single segment: four micro repeaters with ten (AT-MR420TR)/twenty-six (AT-MR820TR) ports. Its design complies with the four-repeater rule. Additional UTP ports are available if the AUI port is used for cascading.
23
Page 46
Topology
Figure 13: AT-MR820TR Four Cascaded Repeaters
The Four-Repeater Rule. The IEEE 802.3 standard provides general
rules for 10Base-T cable length and network connections on single segments of cable or on point-to-point links with media attenuation and signal propagation delays. The basic rule applies for all networks. The maximum number of repeaters in the data path between any two nodes cannot exceed four.
BNC Terminator Switch
The BNC Terminator switch is located on the rear panel to the left of the BNC connector. Use this switch to enable or disable internal termination at this end of the 10Base2 segment.
If you are installing BNC-T connectors in the center of a segment, the termination switch must be disabled (OFF). The general rule is to terminate at each end of the cable segment. If the cable is connected directly into the port without a T-connector (end of segment), turn ON
24
Page 47
AT-MR420TR and AT-MR820TR Installation Guide
the termination switch. Figure 14 shows the location of the two­position 50 Terminator switch. The switch is either ON (the default) or OFF.
Figure 14: Terminator Switch
OFF (disabled) — When installing a hub at an intermediate point of a thinnet cable, a BNC-T connector must be used to connect the cable to the backbone port and the terminator switch must be disabled. See Figure 14.
ON (enabled) — When installing a hub at the end of the cable, if you need to remove the BNC-T connector and the terminator, the backbone port must be connected directly to the thinnet cable. The terminator switch must be enabled. This provides the 50 ohm termination that is required.
Use the OFF position to disable termination if you are
installing a link segment with a BNC-T connector on this port.
Use the ON position to enable termination if you are installing
a link segment without a BNC-T connector at this port, and if the unit is at the end of the cable.
25
Page 48
Topology
Backbone Networks
The most straightforward topology is a backbone network. Figure 15 show a backbone network topology with the AUI port attaching to a coaxial Ethernet cable.
Coaxial Backbone
100 Meters
maximum
Category 3-5
STP/UTP cable
wired Pin to Pin
AUI cable
Ethernet
Transceiver
Figure 15: AT-MR820TR Backbone Topology
In a backbone network topology, each workgroup has its own local network and the backbone is used to link the various workgroups through the bridges. The advantages of a backbone network topology are twofold:
When the backbone network is operating correctly, any
problem within a sub-network does not affect other sub­networks.
Since faults are isolated to a single sub-network, they are
easier to locate.

MDI/MDI-X Switch and Uplink Port

While any RJ45 port can be used to cascade repeaters, port 4/8 has been specifically designed with an uplink (cascading) capability, by providing a Media Dependent Interface (MDI/MDI-X) switch.
Cascading through port 4/8 means if a single, standalone AT-MR420TR/AT-MR820TR Micro Repeater can support 4/8 ports, when a second AT-MR420TR/AT-MR820TR Micro Repeater is uplinked (cascaded) using the port 4/8 of the first unit to any port of a
26
Page 49
AT-MR420TR and AT-MR820TR Installation Guide
second unit. A maximum of four repeaters (the four repeater rule) can be interconnected. The network effectively consists of 6 nodes for the AT-MR420TR and 14 nodes for the AT-MR820TR. The Uplink port is located on the back panel, as shown in Figure 16.
Figure 16: Uplink Port for MR420TR/820TR
Port 4/8 has the ability to become a dedicated uplink port. To facilitate this process, it uses a Media Dependent Interface (MDI/MDI-X) switch.
An MDI/MDI-X switch is a crossover/straight-through cable selection slide switch. As shown in Figure 16, the MDI/MDI-X switch converts the 10Base-T (RJ45) Port 4/ 8, to an uplinkable port that allows one repeater to connect to another repeater without requiring special crossover cables.
The default setting for the RJ45 pinout switch is MDI-X (standard RJ45 port), which means the slide switch is to the right.
In the default MDI-X configuration you can connect the
10Base-T port to a workstation or to any other DTE (that is, node).
27
Page 50
Topology
In the MDI configuration — the slide switch is to the left — you
can connect the 10Base-T port to another 10Base-T internal crossover port, that is, a repeater using straight-through twisted pair cable to form an interrepeater link. See Figure 16.
If you use this port to connect repeaters to each other, the RJ45 pinout switch must be set to MDI. The MDI position is a repeater pinout which automatically swaps the TX and RX pinouts so that they do not conflict with the TX and RX ports at the other end of a straight-through cable.
If you connect a straight-through cable to another repeater or DTE and the Link LEDs on the respective units are not on, change the position of the MDI/MDI-X switch to obtain continuity as indicated by active Link lights. The repeater will not be damaged if the MDI/MDI-X switch is in the wrong position.
In general, if you install an RJ45 port cable, and the Link LED does not light, then simply change the position of the MDI/MDI-X slide switch and see if the Link LED lights.

10Base5 Backbone

Figure 17 illustrates a single multiport 10Base-T AT-MR820TR Micro Repeater connecting to a thick Ethernet backbone using a transceiver.
100 Meters
maximum
Category 3-5 STP/UTP cable wired Pin to Pin
28
Coaxial Backbone
AUI cable
Figure 17: 10Base5 Backbone Topology
Ethernet
Transceiver
Page 51
AT-MR420TR and AT-MR820TR Installation Guide

10Base2 Backbone

A maximum of 30 AT-MR420TR/AT-MR820TR Micro Repeaters can be connected in a network using 10Base2 (thin Ethernet). When you use the BNC port, you avoid using transceivers to complete the linkage. See Figure 18.
Figure 18: AT-MR820TR on a Backbone Using the BNC Network Port
29
Page 52
Topology

Fiber Optic Backbone

By attaching a fiber optic transceiver, the AUI port can connect your network to a fiber optic (10Base-FL/FOIRL) cable backbone.
100 Meters
maximum
Category 3-5
UTP cable
wired 
Pin to Pin
Fiber Optic Transceiver
Fiber Optic cable
Figure 19: AT-MR820TR on a Fiber Optic Backbone
The advantages of fiber optic cable are as follows:
immune to electromagnetic interference spans longer distances without attenuation eliminates grounding problems secure from unauthorized taps
10Base-FOIRL. The IEEE FOIRL (fiber-optic inter-repeater link) standard limit of a fiber segment is 1 km. The fiber optic cable that connects two repeaters is limited to 1 km.
10Base-FL. The more recent IEEE 10Base-FL standard extends a fiber segment length to 2 km. This applies only to topologies in which one 10Base-FL node connects to another 10Base-FL node.
30
Page 53
Appendix A
Technical Specifications
The AT-MR420TR/AT-MR820TR Specifications

Physical

Height 37.6 mm (1.55 in.) Width 332 mm (13 in.) Depth 112 mm (4.4 in.) Installation options Tabletop or rack-mount

Electrical Rating

Input voltage 100-120 or 200-240 VAC Frequency 50 or 60 Hz Amperage 0.5/0.25 Amp

Connector Ports

4/8 RJ45 Ethernet ports (MDI-X) 1 AUI D-type, 15-pin female port 1 BNC female port

Environmental

Operating temperature 0˚ to +40˚ C (32˚ to 104˚ F) Relative humidity 0% to 95%, non-condensing
31
Page 54
Technical Specifications

Diagnostic LEDs

Individual port link status (4/8) Individual port receive activity (4/8) Hub status (3), specifying:
Both Transmit and Receive activity Collision Power

Certification

Safety UL 1950, CSA 22.2 No. 950 (Canadian
Standards Association), TUV EN60950
Emission FCC Part 15 Class A, VCCI Class 1,
CDOC Class A, EN55022 (CISPR 22) Class A

10Base-T Pin Assignments

An Ethernet twisted-pair link segment requires two pairs of wires. Each wire pair is identified by solid and striped colored wires. For example, one wire in the pair might be red and the other wire, red with white stripes.
32
Page 55
AT-MR420TR and AT-MR820TR Installation Guide

Connectors

Notice how the pins are numbered in Figure 20. Be sure to hold the connectors in the same orientation when connecting the wires to the pins.
8
1
8
1
Figure 20:
Connector Pin Numbers
Each twisted-pair link segment must have a male connector attached to both ends. According to the 10Base-T specification, pins 1 and 2 on the connector are used for transmitting data; pins 3 and 6 are used for receiving data, as shown in Table 3. The TX and the RX in Table 3 represent Transmitted Data and Ready Data, respectively.
Table 3: Pin Assignments
Pin Assignment *
1 TX+ 2 TX­3 RX+ 6 RX-
*The “+” and “-” signs are used to represent the polarity of the two wires that make up each
wire pair.
33
Page 56
Technical Specifications

Straight-through Wiring

If the twisted-pair link segment is to join two ports on a switch, and only one of the ports has an internal crossover, the two pairs of wires must be straight-through, as shown in Table 4.

Table 4: Straight-through RJ45 Pin Assignments

Hub Device

1 (TX+) 1 (TX+)

2 (TX-) 2 (TX-) 3 (RX+) 3 (RX+) 6 (RX-) 6 (RX-)

Crossover Wiring

Two AT-MR420TR/AT-MR820TR Micro Repeaters can communicate only if the transmitter on one unit is connected to the receiver on the other unit. This reversal, or crossover function, can be implemented either in the wiring or in the device itself using the MDI/MDI-X switch. When connecting AT-MR420TR/AT-MR820TR Micro Repeaters, a crossover must be used in the wiring when using any port other than 4/8. See Table 5 for crossover pin assignments.

Table 5: Crossover RJ45 Pin Assignments

AT-MR420TR/MR820TR AT-MR420TR/MR820TR

1 (TX+) 3 (RX+)

2 (TX-) 6 (RX-)

3 (RX+) 1 (TX+)

6 (RX-) 2 (TX-)

34
Page 57
AT-MR420TR and AT-MR820TR Installation Guide

5 - 4 - 3 Rule

In addition to the requirements outlined in Chapter 3, Table 2, follow the “5-4-3 rule” to ensure that your configuration does not exceed the maximum 10Base-T data transmission path (the longest path through any given network).
The 5-4-3 rule describes the maximum path between any two devices or nodes (PCs or other stations) on the network. There can be:
Up to five segments in series Up to four repeaters or multiport hubs Up to three populated segments (that is, segments attached to
two or more PCs)*
* The remaining two segments are unpopulated; these are known as inter-repeater links or IRLs. This distinction between populated and unpopulated segments is significant for coax networks only.
Note
This rule is completely consistent with the IEEE 802.3 specification, and is meant only to summarize the configuration specification.
35
Page 58
Page 59
Appendix B

Glossary

10Base2—Also called thin Ethernet, thinnet or CheaperNet, a 10 MHz baseband specification. Cable impedance is 50 Ω and maximum coaxial segment length is 185 meters (607 ft.).
10Base5—Also called thick Ethernet, a 10 MHz baseband specification. Cable impedance is 50 and maximum coaxial segment is 500 meters (1,640 ft.). The cable is commonly referred to as yellow cable. Thick Ethernet cable is typically used as a trunk or backbone path of the network.
10Base-T—IEEE 802.3 STP/UTP Ethernet. Low-cost Level 3 or better STP/ UTP wiring affords 100 meters (328 ft.) of point-to-point link segments. STP/ UTP uses RJ45 connectors and sometimes 50-pin Telco connectors to a patch panel and runs at 10 MHz.
ATTACHMENT UNIT INTERFACE (AUI)—Connection between a MAU (transceiver) and a DTE (typically a workstation). Includes a 15-pin D-sub connector and sometimes a 15-conductor twisted pair cable. Maximum length is 50 meters (164 ft.).
BASEBAND COAXIAL SYSTEM—A system whereby information is directly encoded and impressed on the coaxial transmission medium. At any point on the medium, only one information signal at a time can be present without disruption.
BAYONET NUT COUPLE (BNC) CONNECTOR—A 10Base2 thin coax connector with push-on BNC locking lug that quickly locks into place with a half twist.
BIT RATE (BR)—The rate of data throughput on the medium in bits per second. Ethernet specifies 10 million bits per second.
BIT TIME—The duration of one bit symbol (1/BR). Ethernet specifies a bit time of 100 ns.
CARRIER SENSE—In a LAN, an ongoing activity of a data station to detect whether another station is transmitting.
CARRIER SENSE MULTIPLE ACCESS with COLLISION DETECT (CSMA/CD)—This is the access method employed by IEEE 802.3 LAN
transceivers, by which multiple stations compete for use of the transmission
37
Page 60
Glossary
medium (coax cable) for data packet transmission. It provides for a level of error detection should that transmission be corrupted or impeded by contention for the transmission medium.
COAX SEGMENT—A segment of Ethernet cable that contains MAUs. COAXIAL CABLE—A two-conductor (center conductor, shield system),
concentric, constant impedance transmission line used as the trunk medium in the baseband system.
COAXIAL CABLE SEGMENT—A length of coaxial cable sections and coaxial connectors, terminated at each end in its characteristic impedance.
COLLISION—An unwanted condition that results from concurrent transmissions on the physical medium.
COMPATIBILITY INTERFACE—The MDI coaxial cable interface and the AUI branch cable interface, the two points at which hardware compatibility is defined to allow connection of independently designed and manufactured components to the baseband transmission system.
CROSSOVER—Wiring used when connecting a 10Base-T MAU to another 10Base-T MAU or a 10Base-T hub to another 10Base-T hub. For example, one 10Base-T MAU has the TD (Transmitted Data) pair on the same pins as another 10Base-T MAU. If pins were wired straight, there would be two transmitters on one pair and no receiver. As a solution, the crossover cable crosses the TD pair with the RD (Ready Data) pair, to connect the TD pins on one end to the RD pins at the other end.
D-SUB CONNECTOR—The AUI cable uses 15-pin D-sub connectors. “D” refers to the shape of the connector shell. Also called miniature D, DB15, or DIX connectors.
DATA COMMUNICATION EQUIPMENT (DCE)—In RS-232 specification, a module, such as a modem, for connecting a DTE to other equipment. A repeater connected to a terminal or workstation for Omega management use is wired as a DCE.
DATA TERMINAL EQUIPMENT (DTE) —In RS-232 specification, a module typically at the end of a segment (i.e., uninterrupted length of Ethernet cable). The DTE could be an Ethernet workstation, repeater or bridge.
DIX CONNECTOR—See D-Sub Connector HEARTBEAT—See Signal Quality Error HOUSE WIRING—House wiring is the existing wiring inside a building. This
wiring generally originates from one or more wiring closets, such as a telephone room. Some older buildings may have wiring unsuitable for 10 megabit data rates. In these circumstances, it is recommended that the wiring be tested with a 10Base-T signal/wire tester.
38
Page 61
AT-MR420TR and AT-MR820TR Installation Guide
HUB/REPEATER—A hub is a central signal distributor. It is used in a wiring topology consisting of several point-to-point segments originating from a central point. The term hub is often used interchangeably with the term repeater. Multiport 10Base-T, 10Base2 and fiber optic (10Base-FL, FOIRL) repeaters are considered hubs. See Repeater.
HUB-to-HUB WIRING—See MAU-to-MAU Wiring HUB-to-MAU WIRING—STP/UTP cables for 10Base-T hub-to-MAU or NIC
cards are wired straight-through. An RJ45 receptacle at the hub would wire pin-to-pin to the RJ45 receptacle at the MAU.
IMPEDANCE—An electrical characteristic of a circuit dealing with the combination of the AC and DC resistance and the appearance of that resistance to attached circuits.
JABBER LOCK-UP—The MAU’s ability to automatically inhibit the transmit data from reaching the medium if the transmit data time exceeds a specified duration. This duration is in the range of 20 ms to 150 ms. Jabber lock-up protects the medium from being overrun with data packets from a possibly defective device.
JAM—This is a term used to describe the collision reinforcement signal output by the repeater to all ports. The jam signal consists of 96 bits of alternating 1s and 0s. The purpose is to extend a collision sufficiently so that all devices cease transmitting.
JITTER—The shift of the data bit in respect to a standard clock cycle. Jitter is undesirable and must be minimized.
LINK SEGMENT—The link segment of coaxial cable is a segment that has no MAU devices, but links together two LAN devices such as repeaters.
LINK TEST—In 10Base-T Ethernet there is a link test function that validates the STP/UTP link. This consists of a pulse transmitted from point A on one pair that is validated at point B. Point B also transmits a pulse on the second pair to be validated by point A. These pulses occur during media idle states (in between packets).
MAU—See Medium Attachment Unit MAU-to-MAU, HUB-to-HUB WIRING—10Base-T MAU-to-MAU or hub-to-
hub wiring generally requires a cross-over cable located somewhere along the STP/UTP cable run. This may commonly occur at the punch-down block or between the RJ45 wall receptacle and the workstation.
MAU/TRANSCEIVER—An Ethernet transceiver is a MAU. A 10Base-T MAU interfaces the STP/UTP media to an AUI port on a workstation, repeater, bridge or other Ethernet device.
MDI/MDI-X—See Medium Dependent Interface
39
Page 62
Glossary
MEDIUM ATTACHMENT UNIT (MAU) —In a LAN, a device used in a data station to couple the DTE to the transmission medium.
MEDIUM DEPENDENT INTERFACE (MDI)—The mechanical and electrical interface between a hub and a transceiver (MAU). MDI-X is another version of the interface that enables hubs to connect using different pin-outs, thereby avoiding conflicts that occur when receiving and transmitting packets use the same pin-out.
N-SERIES—A barrel shaped, threaded connector used on 10Base5 (thick Ethernet) coaxial cable.
PATCH PANEL—A 10Base-T patch panel may be used between a punch­down block and STP/UTP workstation. The patch panel generally has a female RJ45 connector on the front for each workstation and a Telco (RJ21) connector on the back, which is wired to a punch-down block. This provides a convenient way for the installer or network manager to connect the hub 10Base-T ports into the desired building locations.
POLARITY CORRECTION—Many 10Base-T STP/UTP ports have a polarity correction function. If the STP/UTP wiring has RD- and RD+ inadvertently crossed, the polarity correction function will sample the signal and electrically swap the wires. If the TD- and TD+ wires are crossed, the correction would occur at the MAU on the other end of the STP/UTP link. This occurs within a single pair and should not be confused with the crossover cable.
PROPAGATION DELAY—The time it takes a signal to travel from the input of a system component to the output. Usually measured in nanoseconds. IEEE
802.3 has specific propagation delay maxima for computing propagation budgets when designing a LAN. Cable length plays a major role in propagation delay; for example, a 50-meter (164-foot) AUI cable has a maximum allowable propagation delay of 257 ns. The propagation delay of cable depends on the length and velocity factor of the cable type. There are also propagation delays associated with electronics attached to the system.
PUNCH-DOWN BLOCK—The punch-down block is the wiring panel where the house wiring from the building’s offices terminates. This is where many 10Base-T hubs would be located. Wiring installers use a special punch-down tool to insert the STP/UTP wire for data and voice applications.
REPEATER—A device used to extend the length, topology, or interconnectivity of the physical medium beyond that imposed by a single segment, up to the maximum allowable end-to-end trunk transmission line length. Repeaters perform the basic actions of restoring signal amplitude, waveform and timing applied to normal data and collision signals.
RJ45—This connector is a 10Base-T standard for connecting STP/UTP cabling. SIGNAL QUALITY ERROR (SQE)—Also referred to as Collision or Collision
Presence. This occurs when two devices attempt to transmit at the same time, which is an illegal condition. All ATI transceivers test for SQE.
40
Page 63
AT-MR420TR and AT-MR820TR Installation Guide
SQE TEST—Commonly referred to as Heartbeat, is a special 802.3 signal sent by the MAU to the DTE to test the collision detection function. Some DTE want SQE and others do not. Repeaters do not want the SQE Test.
STRAIGHT-THROUGH—A type of wiring connection where the pins of one connector connect to the same pins of another connector. For example, pin 1 of one connector connects to pin 1 of another connector.
THICK ETHERNET—See 10Base5 THIN ETHERNET—See 10Base2 TRUNK CABLE—The coaxial cable used to distribute signals over long
distances throughout a cable system. UNSHIELDED TWISTED PAIR (UTP)—A cable used in 10Base-T wiring
that consists of at least two twisted pairs of 22 to 26 AWG wire. The pairs should have at least 3 twists per foot and have an impedance of 100 Ω. Level 3, Level 4 and Level 5 UTP cables fit these criteria.
41
Page 64
Page 65
Appendix C
Technical Support Fax Order
Name__________________________________________________________________ Company _______________________________________________________________ Address ________________________________________________________________ City ________________________State/Province _______________________________ Zip/Postal Code ___________________ Country _______________________________ Phone _______________________________Fax _______________________________
Incident Summary
Model number of Allied Telesyn product I am using _____________________________ Network software products I am using________________________________________
______________________________________________________________________
Brief summary of problem _________________________________________________
______________________________________________________________________
Conditions (List the steps that led up to the problem.) ___________________________
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
Detailed description (Use separate sheet, if necessary)
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
When completed, fax this sheet to the appropriate ATI office. Fax numbers can be found on page 47.
43
Page 66
Page 67
Appendix D
CentreCOM A T-MR420TR/A T -MR820TR Guide Feedback
Please tell us what additional information you would like to see discussed in the guide. If there are topics you would like information on that were not covered in the guide, please photocopy this page, answer the questions and fax or mail this form back to Allied Telesyn International Corp. The mailing address and fax number are at the bottom of the page. Your comments are valuable when we plan future revisions of the guide.
I found the following the most valuable _______________________________________
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
I would like the following more developed _____________________________________
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
I would find the guide more useful if _________________________________________
______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________ ______________________________________________________________________
Please fax or mail your feedback. Fax to 1-206-481-3790. Or mail to: Allied Telesyn International Technical Communications Department 19015 North Creek Parkway, #200 Bothell, WA 98011 USA
45
Page 68
Page 69
Appendix E
Where To Find Us
For Technical Support or Service
Location Phone Fax
Asia
Singapore, Taiwan, Thailand, Malaysia, Indonesia, Korea, Philippines, China, India
Australia
Australia, New Zealand
France
France, Belgium, Luxembourg, The Netherlands, Middle East, Africa
Germany
Germany, Switzerland, Austria, Eastern Europe
Hong Kong (+852) 2-529-4111 (+852) 2 529-7661
Italy
Italy, Spain, Portugal, Greece, Turkey, Israel
Japan (+81) 3-3443-5640 (+81) 3-3443-2443
North America
United States, Canada, Mexico, Central America, South America
United Kingdom
United Kingdom, Denmark, Norway, Sweden, Finland, Iceland
Technical Bulletin Board Service 1 (206) 483-7979
CompuServe Go ALLIED
World Wide Web http://www.alliedtelesyn.com
(+65) 3815-613 (+65) 3833-830
(612) 416-0619 (612) 416-9764
(+33) 1-60-92-15-32 (+33) 1-69-28-37-49
(+49) 30-435-900-126 (+49) 30-435-70-650
(+39) 2-416047 (+39) 2-419282
1 (800) 428-4835 1 (206) 481-3790
(+44) 1-235-442560 (+44) 1-235-442490
For Information Regarding Allied Telesyn International Corp.
Allied Telesyn International Corp.
19015 North Creek Parkway Suite 200 Bothell, WA 98011 Tel: 1 (206) 487-8880 Fax: 1 (206) 489-9191
Allied Telesyn International Corp.
950 Kifer Road Sunnyvale, CA 94086 Tel: 1 (800) 424-4284 (USA and Canada) Fax: 1 (408) 736-0100
47
Page 70
Where To Find Us
For Sales Information
Australia Lindfield, NSW
Tel: (612) 416-0619, Fax: (612) 416-9764
Canada Rexdale, Ontario
Tel: (416) 675-6738, Fax: (416) 675-0057
Richmond, British Columbia
Tel: (604) 244-0678, Fax: (604) 270-3644
England Abingdon, Oxon
Tel: (+44) 1235-442500, Fax: (+44) 1235-442590
France Les Ulis
Tel: (+33) 1-60921525, Fax: (+33) 169-28-37-49
Germany Berlin
Tel: (+49) 30-435-90-00, Fax: (+49) 30-435-706-50
Freising
Tel: (+49) 8161-9906-0, Fax: (+49) 8161-9906-22
Hong Kong Wanchai
Tel: (+852) 2-529-4111, Fax: (+852) 2-529-7661
Italy Milano
Tel: (+39) 2-416047, Fax: (+39) 2-419282
Japan Machida-shi, T okyo
Tel: (+81) 427-21-8141, Fax: (+81) 427-21-8848
Yodogawa-ku, Osaka
Tel: (+81) 6-391-6310, Fax: (+81) 6-391-6325
Singapore
Tel: (+65) 383-3832, Fax: (+65) 383-3830
United States Scottsdale, AZ
Tel: (602) 423-7087 Fax: (602) 423-7088
Los Angeles, CA
Tel: (310) 412-8684, Fax: (310) 412-8685
Mission Viejo, CA
Tel: (714) 699-0628, Fax: (714) 699-0276
San Diego, CA
Tel: (619) 279-3899, Fax: (619) 279-3897
Santa Ana, CA
Tel: (714) 838-0434, Fax: (714) 838-9721
Clearwater, FL
Tel: (813) 726-0022, Fax: (813) 726-0234
Norcross, GA
Tel: (770) 448-7214, Fax: (770) 448-2600
Reading, MA
Tel & Fax: (617) 944-3492
Eden Prairie, MN
Tel: (612) 829-7506, Fax: (612) 903-5284
St. Louis, MO
Tel: (314) 894-6160, Fax: (314) 894-3773
Dover, NH
Tel: (603) 743-3010, Fax: (603) 743-6327
Plaistow, NH
Tel: (603) 382-0815, Fax: (603) 382-0818
Portsmouth, NH
Tel: (603) 431-6461, Fax: (603) 431-1649
Morrisville, NC
Tel: (919) 468-0831, Fax: (919) 468-0829
Lake Oswego, OR
Tel: (503) 699-3130, Fax: (503) 636-6575
Austin, TX
Tel: (512) 261-6378, Fax: (512) 261-6379
Dallas, TX
Tel: (214) 365-9471, Fax: (214) 365-9472
San Antonio, TX
Tel: (210) 646-8744
Vienna, V A
Tel: (703) 506-0196, Fax: (703) 506-1986
48
Page 71
Appendix F
Index
Numerics
50 terminator switch 4, 6
802.3 transceiver 5
A
ambient temperature 7 application specific integrated circuit
(ASIC) 3
B
backbone
10Base5 29 fiber optic 30
backbone network ports 2
C
cabling
10Base2 4, 6, 17, 19 10Base2 (thin) ethernet 19 10Base5 5, 9, 15, 17 10Base5 (thick) ethernet 18 10Base-FL 30 10Base-T 8, 9, 13, 15, 17, 20,
27 5 - 4 - 3 rule 35 AUI drop 18 connectors 33 crossover 34 data-quality 20 four repeater rule 24 straight-through 33 voice-quality 20
connections 9 connectivity 15 connectors
power 15 RG58U 19 UTP (RJ45) 20
D
data terminal equipment 12
E
external transceiver 8
F
features 3
auto partitioning 3 jabber lock-up protection 3 link integrity 3 regeneration 3
G
ground 4
I
indicators
activity 1 collision 1 hub status 12 link 1 link ok 9, 11, 13 port 10 power 1, 8 receive 1, 11
installation 7
power 7 quick 8 ventilation 7
L
LED 1 local area network (LAN) 1
M
Maximum segment length 4 media dependent interface (MDI) 26 medium attachment unit (MAU) 19, 20
N
network interface controller (NIC) 20
O
overview 1
P
pins
10BASE-T pin assignments 32
ports
49
Page 72
Index
10Base2/AUI backbone switches 5 AUI 17 AUI network 9 backbone 17 backbone network 4 BNC 19 BNC network 9 network backbone 15 RJ45 9 uplink 2, 8
power conditioners 15 product description 1
R
RJ45 network ports 2
S
segmentation 3 signal quality error (SQE) 8 site requirements 7 specifications
10Base-T Network 17 certification 32 connector ports 31 diagnostic LEDs 32 electrical 31 environmental 31 physical 31
surface mount technology (SMT) 3 switches
backbone enable 5, 6 BNC terminator 24 MDI/MDI-X 27 media select 5, 6
T
technical support services