Alcatel OmniSwitch 6250-24, OmniSwitch 6250-P24, OmniSwitch 6250-24M, OmniSwitch 6250-24MD, OmniSwitch 6250-8M operation manual

Part No. 060303-10, Rev. F September 2015
OmniSwitch 6250
Hardware Users Guide
enterprise.alcatel-lucent.com
This user guide documents the OmniSwitch 6250 for AOS Release 6.7.1.
This user guide documents OmniSwitch 6250 hardware, including chassis and associated components. The specifications described in this guide are subject to change without notice.
26801 West Agoura Road
Calabasas, CA 91301
(818) 880-3500 FAX (818) 880-3505
Service & Support Contact Information
North America: 800-995-2696
Latin America: 877-919-9526
EMEA: +800 00200100 (Toll Free) or +1(650)385-2193
Asia Pacific: +65 6240 8484
Web: service.esd.alcatel-lucent.com
Email: esd.support@alcatel-lucent.com

Contents

About This Guide ..............................................................................................................ix
Supported Platforms ..........................................................................................................ix
Who Should Read this Manual? ........................................................................................xi
When Should I Read this Manual? ....................................................................................xi
What is in this Manual? .....................................................................................................xi
What is Not in this Manual? ..............................................................................................xi
How is the Information Organized? ................................................................................. xii
Documentation Roadmap ......................................................................................... .... ... .xii
Related Documentation ...................................................................................................xiv
Product Documentation ....................................................................................................xv
Technical Support ............................................................................................................xv
Documentation Feedback .................................................................................................xv
Chapter 1 OmniSwitch 6250 ............................................................................................................ 1-1
Chassis Configurations ....................................................................................................1-2
OmniSwitch 6250 Feature Overview ..............................................................................1-3
Security Features .............................................................................................................1-3
Applications ....................................................................................................................1-3
Availability Features .......................................................................................................1-4
Software Rollback ................................................................. .... ...............................1-4
Hot Swapping ...........................................................................................................1-4
Hardware Monitoring ............................................. .... ..............................................1-5
Backup Power Supplies ............................................................................................1-5
Chapter 2 Getting Started ...............................................................................................................1-1
Installing the Hardware ...................................................................................................1-1
Items Required ........................................................... .... ..........................................1-1
Site Preparation ........................................................................................................1-1
Environmental Requirements ............................................................................1-1
Electrical Requirements .....................................................................................1-1
Unpacking and Installing the Switch .......................................................................1-2
Items Included ........................................................................................ .... .......1-2
Weight Considerations ......................................................................................1-2
Airflow Considerations .....................................................................................1-3
Mounting the Switch .......................................................................................................1-3
OmniSwitch 6250 Hardware Users Guide September 2015 iii
Contents
Connections and Cabling ................................................................................................1-4
Serial Connection to the Console Port ...............................................................1-4
Serial Connection Default Settings ...................................................................1-4
Booting the Switch ..........................................................................................................1-5
Component LEDs ..............................................................................................1-5
Your First Login Session ................................................................................................1-6
Logging In to the Switch ..........................................................................................1-6
Unlocking Session Types .............................................................. .... .... ...................1-7
Changing the Login Password ..................................................................................1-8
Setting the System Time Zone .................................................................................1-8
Setting the Date and Time ........................................................................................1-8
Setting Optional Parameters ................... ..................................................................1-9
Specifying an Administrative Contact ........................................ .... .... .... ...........1-9
Specifying a System Name ................................................................................1-9
Specifying the Switch’s Location ......................................................................1-9
Viewing Your Changes ............................................................................................1-9
Saving Your Changes ...............................................................................................1-9
Chapter 3 OmniSwitch 6250 Chassis and Hardware Components ................................................3-1
OmniSwitch 6250-8M .....................................................................................................3-3
OmniSwitch 6250-8M Rear Panel .................................................... .... .... ...............3-5
OmniSwitch 6250-24M/24MD .......................................................................................3-7
OmniSwitch 6250-24M/24-MD Rear Panel ............................................................3-9
OmniSwitch 6250-24 ....................................................................................................3-12
OmniSwitch 6250-24 Rear Panel ...........................................................................3-14
OmniSwitch 6250-P24 ..................................................................................................3-16
OmniSwitch 6250-P24 Rear Panel .........................................................................3-18
LED Status ............................................................................................................3-20
OS6250 - Power Supplies .............................................................................................3-21
Internal AC Power Supply .....................................................................................3-22
Internal DC Power Supply .....................................................................................3-23
PS-42W-AC Power Brick ......................................................................................3-24
PS-30W-DC Power Brick ......................................................................................3-25
PS-225W-AC-P PoE Power Supply Module .........................................................3-26
Power Supply Tray .................................................................................................3-27
AC Power Cords ...........................................................................................................3-28
Specifications .........................................................................................................3-28
DC Power Specifications ..............................................................................................3-29
OS6250-24MD Internal DC Power Supply ...........................................................3-29
Backup DC Power Brick ........................................................................................3 -29
Stacking Cables .............................................................................................................3-30
Console Port ..................................................................................................................3-31
iv OmniSwitch 6250 Hardware Users Guide September 2015
Contents
Port Pinouts .................................................................................. .................................3-32
RJ-45 Console Port – Connector Pinout ................................................................3-32
10/100 Ethernet Port – RJ-45 Pinout (non-PoE) .................................................... 3-32
Gigabit Ethernet Port – RJ-45 Pinout .....................................................................3-32
10/100/1000 Mbps Power over Ethernet Port – RJ-45 Pinout ..............................3-33
Overtemp Condition ................... ... .... ....................................................... .... .................3-33
Dying Gasp ....................................................................................................................3-34
Scenarios ................................................................................................................3-34
SNMP Trap ......................................................................................................3-34
Syslog Message ...............................................................................................3-34
Link OAM PDU ..............................................................................................3-35
Chapter 4 Mounting OS6250 Switches ............................................................................................4-1
Chassis Components ................................................................................................4-1
Available Mounting Kits ..........................................................................................4-2
General Installation Recommendations ..........................................................................4-3
Cooling Recommendations ......................................................................................4-3
Recommended Clearances .......................................................................................4-4
Mechanical Loading .................................................................................................4-4
Circuit Overloading ..................................................................................................4-4
Reliable Earthing ......................................................................................................4-4
Power Supply Information ..............................................................................................4-5
Assembling OS6250 Switches ........................................................................................4-6
Assembly Guidelines ................................................................................................4-6
Attaching the Power Supply Tray on Side of Chassis .............................................4-6
OS6250-RM-19 - Power supply tray side installation ......................................4-6
OS6250-DUAL-MNT - Attaching Two Chassis Side-by-Side ..............................4-10
Attaching Power Supply Tray to Rear of Chassis ..................................................4-12
Securing Power Supplies in Power Supply Tray ...................................................4-13
Power Supply Brick Installation ......................................................................4-13
Power Supply Module Installation ..................................................................4-14
Mounting OS6250 Switches .........................................................................................4-15
Rack-Mounting OS6250 Switches .........................................................................4-15
General Rack-Mounting Guidelines ................................................................4-15
Rack-Mounting Installation .............................................................................4-15
Power Supply Tray - Removeable Section ...................................................... 4 -17
OS6250-RM-19-L - Mounting Instructions ....................................................4-18
OS6250-REAR-MNT - Mounting Instructions ...............................................4-19
Steps ......................................................................................................................4-19
Completed Assembly .............................................................................................4-20
Table-Mounting OS6250 Switches ........................................................................4-21
General Table-Mounting Guidelines ............................................................... 4-21
Table-Mounting Installation ............................................................................4-21
Wall-Mounting the OS6250-8M ............................................................................4-23
General Wall-Mounting Guidelines ................................................................4-23
OS6250-WALL-MNT - Wall-Mounting Installation ......................................4-24
OmniSwitch 6250 Hardware Users Guide September 2015 v
Contents
Connecting Chassis to Power Source ............................................................................4-26
AC Power Supply Connections ..............................................................................4-26
Powering On a Chassis .................................... .... ............................................4-26
OS6250-24MD Internal DC Power Supply Connections ................................4-27
Backup DC Power Brick Connections ............................................................4-27
Securing the Redundant DC Power Supply Connector ...................................4-28
Installing DC Power Source Wire Leads .........................................................4-29
Hot-Swapping Power Supplies ...................................................................... .........4-31
Chapter 5 Booting 6250 Switches ....................................................................................................5-1
Booting an OmniSwitch 6250 ..................................................................................5-1
Console Port ....................................................................................................................5-2
Serial Connection Default Settings ..........................................................................5-2
Modifying the Serial Connection Settings ...............................................................5-2
Viewing the Power Supply Status ..................................................................... 5-4
Monitoring the Chassis ...................................................................................................5-5
Checking the Overall Chassis Status ........................................................................5-5
Checking the Temperature Status ............................................................................5-5
Checking the Fan Status ...........................................................................................5-6
Checking the Power Supply Status ..........................................................................5-6
Additional Monitoring Commands ..........................................................................5-6
Using LEDs to Visually Monitor the Chassis ..........................................................5-7
Installing SFP and XFP Transceivers .......................................................................5-7
Chapter 6 Managing Power over Ethernet (PoE) ...........................................................................6-1
In This Chapter ................................................................................. .... .... .... ...................6-2
Power over Ethernet Specifications ................................................................................6-3
Viewing PoE Power Supply Status .................................................................................6-4
Configuring Power over Ethernet Parameters .................................................................6-5
Power over Ethernet Defaults ..................................................................................6-5
Understanding and Modifying the Default Settings .................................................6-5
Setting the PoE Operational Status ....................................................................6-5
Configuring the Total Power Available to a Port ............................... ...............6-6
Configuring the Total Power Available to a Switch .........................................6-6
Setting Port Priority Levels ...............................................................................6-7
Understanding Priority Disconnect .................................................................................6-8
Setting Priority Disconnect Status ............................................................................6-8
Disabling Priority Disconnect ...........................................................................6-8
Enabling Priority Disconnect ............................................................................6-8
Monitoring Power over Ethernet via CLI .....................................................................6-11
vi OmniSwitch 6250 Hardware Users Guide September 2015
Contents
Chapter 7 Managing OmniSwitch 6250 Stacks ............................................................................... 7-1
In This Chapter ................................................................................. .... .... .... ...................7-2
OmniSwitch 6250 Stacking Specifications .....................................................................7-3
Changing Stacking Mode on Metro Models ............................................................7-3
OmniSwitch 6250 Stack Overview .................................................................................7-4
Roles Within the Stack ....................................................................................................7-4
Primary and Secondary Management Modules .......................................................7-4
Primary Management Module Selection ...........................................................7-7
Secondary Management Module Selection ..................................................... 7-10
Idle Module Role ....................................................................................................7-12
Pass-Through Mode ...............................................................................................7-13
Recovering from Pass-Through Mode (Duplicate Slot Numbers) ..................7-14
Stack Cabling ............................. ... .... .... ................................................... .... .... .............7-17
Redundant Stacking Cable Connection ..................................................................7-18
Checking Redundant Stacking Cable Status ..........................................................7-19
Slot Numbering .............................................................................................................7-20
Dynamic Slot Number Assignment ........................................................................7-21
Manual Slot Number Assignment ..........................................................................7-23
Reverting to the Dynamic Slot Numbering Model ..........................................7-24
Hot-Swapping Modules In a Stack ...............................................................................7-25
Removing Switches from an Existing Stack ..........................................................7-25
Inserting Switches Into an Existing Stack ..............................................................7-25
Merging Stacks .......................................................................................................7-26
Reloading Switches .......................................................................................................7-27
Reloading the Primary Management Module ........................................................7-27
Reloading the Secondary Management Module ....................................................7-29
Reloading Switches with Idle Roles .......................................................................7-31
Reloading Switches in Pass-Through Mode ..........................................................7-31
Reloading All Switches in a Stack .........................................................................7-32
Software Synchronization During a Full Reload .............................................7-32
Effects of Saved Slot Number Information on the Reload Process .................7-32
Avoiding Split Stacks .............................................................................................7-34
Changing the Secondary Module to Primary ................................................................7-35
Synchronizing Switches in a Stack ...............................................................................7-37
Automatic Synchronization During a Full Reload .................................................7-37
Stack Split Detection (SSP) ..........................................................................................7-38
Stack Split Key Components and Terms ................................................................7-38
Basic Operation .............................................................. ... .... .................................7-39
Protection States .....................................................................................................7-39
Stack Split Recovery .......................................................................................7-39
Monitoring the Stack .....................................................................................................7-41
Visually Monitoring the Stack ...............................................................................7-42
OmniSwitch 6250 Hardware Users Guide September 2015 vii
Contents
Appendix A Regulatory Compliance and Safety Information ................................................... .........A-1
Declaration of Conformity: CE Mark .............................................. .... .... ......................A-1
China RoHS: Hazardous Substance Table .....................................................................A-2
California Proposition 65 Warning ................................................................................A-3
Waste Electrical and Electronic Equipment (WEEE) Statement ...................................A-4
Standards Compliance ....................................................................................................A-5
Safety Agency Certifications ..................................................................................A-5
EMI/EMC Standards ...............................................................................................A-5
FCC Class A, Part 15 ..............................................................................................A-6
Canada Class A Statement ............................................. ... ......................................A-6
JATE ........................................................................................................................A-6
CISPR22 Class A warning ......................................................................................A-6
Korean Emission Statement .................................................................................... A-7
VCCI .......................................................................................................................A-7
Class A Warning for Taiwan and Other Chinese Markets ......................................A-7
Network Cable Installation Warning .............................................................................A-8
Translated Safety Warnings ...........................................................................................A-8
Chassis Lifting Warning .................. .................................................................A-8
Electrical Storm Warning ................................................................................. A-8
Installation Warning .........................................................................................A-9
Invisible Laser Radiation Warning ...................................................................A-9
Power Disconnection Warning .........................................................................A-9
Proper Earthing Requirement Warning ..........................................................A-10
Read Important Safety Information Warning ................................................. A-11
Restricted Access Location Warning .............................................................A-11
Wrist Strap Warning .......................................................................................A-12
Instrucciones de seguridad en español .........................................................................A-13
Advertencia sobre el levantamiento del chasis ...............................................A-13
Advertencia de las tapaderas en blanco ..........................................................A-13
Advertencia en caso de tormenta eléctrica ..................................................... A-13
Advertencia de instalación .............................................................................A-13
Advertencia de radiación láser invisible .........................................................A-13
Advertencia de la batería de litio ....................................................................A-13
Advertencia sobre la tensión de operación .....................................................A-13
Advertencia sobre la desconexión de la fuente ..............................................A-13
Advertencia sobre una apropiada conexión a tierra .......................................A-14
Leer “información importante de seguridad” ................................................. A-14
Advertencia de acceso restringido ..................................................................A-14
Advertencia de pulsera antiestática ................................................................A-14
Clase de seguridad ............................... ....................................................... ....A-14
viii OmniSwitch 6250 Hardware Users Guide September 2015

About This Guide

This OmniSwitch 6250 Hardware Users Guide describes your switch hardware components and basic switch hardware procedures.

Supported Platforms

The information in this guide applies to the following products:
OmniSwitch 6250-8M
OmniSwitch 6250-24M
OmniSwitch 6250-24MD
OmniSwitch 6250-24
OmniSwitch 6250-P24
OmniSwitch 6250 Hardware Users Guide September 2015 page ix
Supported Platforms About This Guide
Unsupported Platforms
The information in this guide does not apply to the following products:
OmniSwitch (original version with no numeric model name)
OmniSwitch 6400 Series
OmniSwitch 6600 Series
OmniSwitch 6800 Series
OmniSwitch 6850 Series
OmniSwitch 6855 Series
OmniSwitch 7700
OmniSwitch 7800
OmniSwitch 8800
OmniSwitch 9000 Series
OmniStack
OmniAccess
page x OmniSwitch 6250 Hardware Users Guide September 2015
About This Guide Who Should Read this Manual?

Who Should Read this Manual?

The audience for this users guide is network administrators and IT support personne l who need to config­ure, maintain, and monitor switches and routers in a live network. However, anyone wishing to gain knowledge on the OmniSwitch 6250 hardware will benefit from the material in this guide.

When Should I Read this Manual?

Read this guide as soon as you are ready to familiarize yourself with your switch hardware components. You should have already stepped through the first login procedures and read the brief hardware overviews in the OmniSwitch 6250 Getting Started Guide.
You should already be familiar with the very basics of the switch hardware, such as module LEDs and module installation procedures. This manual will help you understand your switch hardware components (e.g., chassis, stacking and cables, backup power supplies, etc.) in greater depth.

What is in this Manual?

This users guide includes the following hardware-related information:
Descriptions of switch configurations.
Descriptions of “availability” features.
Descriptions of chassis types (e.g., the OS6250-24).
Instructions for mounting the chassis.
Descriptions of hardware components (status LEDs, chassis, cables, backup power supplies, etc.).
Managing a chassis.
Hardware-related Command Line Interface (CLI) commands

What is Not in this Manual?

The descriptive and procedural information in this manual focuses on switch hardware. It includes infor­mation on some CLI commands that pertain directly to hardware configuration, bu t it is not intended as a software users guide. There are several OmniSwitch 6250 users guides that focus on switch software configuration. Consult those guides for detailed information and examples for configuring your switch software to operate in a live network environment. See “Documentation Roadmap” on page -xii and
“Related Documentation” on page -xiv for further information on software configuration guides available
for your switch.
OmniSwitch 6250 Hardware Users Guide September 2015 page xi
How is the Information Organized? About This Guide

How is the Information Organized?

This users guide provides an overview of OmniSwitch 6250 switches, specificat ions of the hardware components, steps for setting up and managing OmniSwitch 6250 switches, and an overview and proce­dures for managing Power over Ethernet (PoE).

Documentation Roadmap

The OmniSwitch user documentation suite wa s design ed to supply you with information at several critical junctures of the configuration process.The following section outlines a roadmap of the manuals that will help you at each stage of the configuration process. Under each stage, we point you to the manual or manuals that will be most helpful to you.
Stage 1: Using the Switch for the First Time
Pertinent Documentation: Getting Started Guide
Release Notes
The Getting Started Guide provides all the information you need to get your switch up and running the first time. This guide provides information on unpacking the switch, installing power supplies, unlocking access control, setting the switch’s IP address, and setting up a password. It also includes succinct over­view information on fundamental aspects of the switch, such as hardware LEDs, the software directory structure, stacking, CLI conventions, and web-based management.
At this time you should also familiarize yourself with the Release Notes that accompanied your switch. This document includes important information on feature limitations that are not included in other user guides.
Stage 2: Gaining Familiarity with Basic Switch Functions
Pertinent Documentation: Hardware Users Guide
Switch Management Guide
Once you have your switch up and running, you will want to begin investigating basic aspects of its hard ware and software. Information about switch hardware is provided in the Hardware Users Guide. This guide provide specifications, illustrations, and descriptions of all hardware components—e.g., chassis, backup power supplies, etc.
The Switch Management Guide is the primary user guide for the basic software features on a switch. This guide contains information on the switch directory structure, basi c fi le and directory utilities, switc h access security, SNMP, and web-based management. It is recommended that you read this guide before connect­ing your switch to the network.
page xii OmniSwitch 6250 Hardware Users Guide September 2015
About This Guide Documentation Roadmap
Stage 3: Integrating the Switch Into a Network
Pertinent Documentation: Network Configuration Guide
When you are ready to connect your switch to the network, you will need to learn how the OmniSwitch implements fundamental softwa re features, such as 802.1Q, VLANs, and Spanning Tree. The Network Configuration Guide contains overview information, procedures and examples on how standard network­ing technologies are configured in the OmniSwitch 6250.
Anytime
The OmniSwitch CLI Reference Guide contains comprehensive information on all CLI commands supported by the switch. This guide includes syntax, default, usage, example, related CLI command, and CLI-to-MIB variable mapping information for all CLI commands supported by the switch. This guide can be consulted anytime during the configuration process to find detailed and specific information on each CLI command.
OmniSwitch 6250 Hardware Users Guide September 2015 page xiii
Related Documentation About This Guide

Related Documentation

The following are the titles and descriptions of all the OmniSwitch 6250 user manuals:
OmniSwitch 6250 Getting Started Guide
Describes the hardware and software procedures for getting an OmniSwitch 6250 switch up and running. Also provides information on fundamental aspects of OmniSwitch software.
OmniSwitch 6250 Hardware Users Guide
Detailed technical specifications and procedures for the OmniSwitch 6250 chassis and components. This manual also includes comprehensive information on assembling and managing stacked configura­tions.
OmniSwitch 6250/6450 CLI Reference Guide
Complete reference to all CLI commands supported on the OmniSwitch Series of products. Includes syntax definitions, default values, examples, usage guidelines and CLI-to-MIB variable mappings.
OmniSwitch 6250/6450 Switch Management Guide
Includes procedures for readying an individual switc h for integ ration into a ne twork. To pics in clud e the software directory architecture, image rollback protections, authenticated switch access, managing switch files, system configuration, using SNMP, and using web management software (WebView).
OmniSwitch 6250/6450 Network Configurat ion Guide
Includes network configuration procedures and descriptive information on all the major software features and protocols included in the base software package. Chapters cover Layer 2 information (Ethernet and VLAN configuration), Layer 3 information (routing protocols, such as RIP), security options (authenticated VLANs), Quality of Service (QoS), and link aggregation.
OmniSwitch 6250/6450 Transceivers Guide
Includes SFP and XFP transceiver specifications and product compatibility information.
Technical Tips, Field Notices
Includes information published by Alcatel-Lucent’s Customer Support group.
Release Notes and Upgrade Instructions
Includes open problem reports, feature exceptions, and other important information on the features supported in the current release and any limitations to their support.
page xiv OmniSwitch 6250 Hardware Users Guide September 2015
About This Guide Product Documentation

Product Documentation

All products are shipped with a Product Documentation Card that prov ides details for downloading docu­mentation for all OmniSwitch and other Alcatel-Lucent data enterprise products. All user guides for the OmniSwitch Series are included on the Alcatel-Lucent public website. This website also includes user guides for other Alcatel-Lucent Enterprise products. The latest user guides can be found on our website at:
http://enterprise.alcatel-lucent.com/UserGuides

Technical Support

An Alcatel-Lucent service agreement brings your company the assurance of 7x24 no-excuses technical support. You’ll also receive regular software updates to maintain and maximize your Alcatel-Lucent prod­uct’s features and functionality and on-site hardware replacement through our global network of highly qualified service delivery partners. Additionally, with 24-hour-a-day access to Alcatel-Lucent’s Service and Support web page, you’ll be able to view and update any case (open or closed) that you have reported to Alcatel-Lucent’s technical support, open a new case or access helpful release notes, technical bulletins, and manuals. For more information on Alcatel-Lucent’s Service Programs, see our web page at service.esd.alcatel-lucent.com, call us at 1-800-995-2696, or email us at esd.support@alcatel-lucent.com.

Documentation Feedback

Alcatel-Lucent values comments on the quality and usefulness of the documentation. To send comments on the OmniSwitch documentation use the following email address: feedback.osdocs@alcatel-lucent.com.
For document identification it's helpful to include the Document Title, Part Number and Revision (which can be found on the title page) with any comments.
OmniSwitch 6250 Hardware Users Guide September 2015 page xv
Documentation Feedback About This Guide
page xvi OmniSwitch 6250 Hardware Users Guide September 2015

1 OmniSwitch 6250

OS6250-24
OS6250-8M
OS6250-P24
OS6250-24M
OS6250-24MD
The Alcatel-Lucent OmniSwitch 6250 is a set of stackable switches designed for Enterprise and Metro applications providing Fast Ethernet connectivity with Advanced Layer 2 software and basic routing.
OS6250 Switches
OmniSwitch 6250 Hardware Users Guide September 2015 page 1-1
Chassis Configurations OmniSwitch 6250

Chassis Configurations

OmniSwitch 6250 (OS6250) switches offer port densities of up to 24 Fast Ethernet ports. The following OS6250 chassis configurations are available:
Metro Models
OS6250-8M: Provides eight (8) Fast Ethernet ports, two (2) combo ports, two (2) non-combo fiber
ports, and an internal AC power supply.
OS6250-24M: Provides twenty-four (24) Fast Ethernet ports, two (2) combo ports, two (2) non-combo
fiber ports, an internal AC power supply, and optional redundant external power supply.
OS6250-24MD: Provides twenty-four (24) Fast Ethernet ports, two (2) combo ports, two (2) non-
combo fiber ports, an internal DC power supply, and optional redundant external power supply.
Enterprise Models
OS6250-24: Provides twenty-four (24) Fast Ethernet ports, two (2) combo ports, two HDMI stacking
ports, an internal AC power supply, and optional external redundant power supply.
OS6250-P24: Provides twenty-four (24) PoE Fast Ethernet ports, two (2) combo ports, two (2) HDMI
stacking ports, and external primary and redundant power supplies.
Combo Ports
Combo ports are individually configurable to be 10/100/1000BaseT or 100/1000X that can support SFP transceivers for short, long and very long distances.
Non-combo Fiber Ports
The non-combo fiber ports provide uplink or stacking capability through the use of the SFP+ ports.
HDMI Ports
The HDMI ports provide stacking capability through the use of Alcatel-Lucent proprietary stacking cables.
page 1-2 OmniSwitch 6250 Hardware Users Guide September 2015
OmniSwitch 6250 OmniSwitch 6250 Feature Overview

OmniSwitch 6250 Feature Overview

Security Features

OmniSwitch 6250 switches offer extensive security features for network access control, policy enforce­ment and attack containment, enabling fully secure networks and OmniVista Network Management System (NMS) support.

Applications

Well-suited for traditional enterprise network applications as well as Metro deployments.
Small and Medium sized Enterprise (SME)
Metro Ethernet Access
Residence and business deployments
Carrier Ethernet (e.g., Telco, CityNets, Metro access)
OmniSwitch 6250 Hardware Users Guide September 2015 page 1-3
Availability Features OmniSwitch 6250

Availability Features

OmniSwitch 6250 switches incorporate advanced Alcatel-Lucent Operating System (AOS) protocol s to ensure high availability for mission critical applications. Availability features are hardware- and software­based safeguards that help to prevent the loss of data flow in the unlikely event of a subsystem failure.
In addition, some availability features allow users to maintain or replace hardware components without powering off the switch or interrupting switch operations. Combined, these features provide added resiliency and help to ensure that the switch or virtual chassis is consistently available for high-impact network operations.
Hardware-related availability features include:
Software Rollback
Hot Swapping
Hardware Monitoring
Backup Power Supplies

Software Rollback

Software rollback (also referred to as image rollback) essentially allows the switch to return to a prior “la st known good” version of software in the event of a system software problem. The switch controls software rollback through its resilient directory structure design (i.e., /flash/working and /flash/certified).
For detailed information on the software rollback feature, as well as the switch’s /flash/working and
/flash/certified directories, refer to the “Managing CMM Directory Content” chapter in the Switch Management Guide.

Hot Swapping

Hot swapping refers to the action of adding, removing, or replacing components without powering off switches or disrupting other components.This feature facilitates hardware upgrades and maintenance and allows users to easily replace components in the unlikely event of hardware failure.
The following components can be hot swapped:
Backup power supplies
Power supply connector cables
SFPs
Note. For instructions on hot swapping backup power supplies, refer to Chapter 4, “Mounting OS6250
Switches” For instructions on hot swapping combo connector SFPs, refer to the instruction card provided
with the SFP.
page 1-4 OmniSwitch 6250 Hardware Users Guide September 2015
OmniSwitch 6250 Availability Features

Hardware Monitoring

Automatic Monitoring
Automatic monitoring refers to the switch’s built-in sensors that automatically monitor operations. If an error is detected (e.g., over-threshold temperature), the switch immediately sends a trap to the user. The trap is displayed on the console in the form of a text error message.
LEDs
LEDs, which provide visual status information, are provided on the chassis front panel. LEDs are used to indicate conditions such as hardware and software status, temperature errors, link integrity, data flow, etc. For detailed LED descriptions, refer to Chapter 3, “OmniSwitch 6250 Chassis and Hardware Compo-
nents.”
User-Driven Monitoring
User-driven hardware monitoring refers to CLI commands that are entered by the user in order to access the current status of hardware components. The user enters “show” commands that output information to the console. Monitoring information for chassis components, such as the optional back up power supply, chassis temperature sensor, and chassis fans is provided in Chapter 3, “OmniSwitch 6250 Chassis and
Hardware Components.” The show commands for all the features are described in detail in the OmniS-
witch CLI Reference Guide.

Backup Power Supplies

Some OmniSwitch 6250 switches support an optional backup power supply. Backup power supplies oper­ate in active standby mode. If the primary power supply fails unexpectedly, the backup power supply auto­matically takes up the full power load without disrupting the switch.
Note. For more information on power supplies, refer to Chapter 3, “OmniSwitch 6250 Chassis and Hard-
ware Components.”
OmniSwitch 6250 Hardware Users Guide September 2015 page 1-5
Availability Features OmniSwitch 6250
page 1-6 OmniSwitch 6250 Hardware Users Guide September 2015

2 Getting Started

Installing the Hardware

Items Required

Grounding wrist strap
Phillips screwdriver
Flat-blade screwdriver

Site Preparation

Environmental Requirements
OmniSwitch 6250 switches have the following environmental and airflow requirements:
The installation site must maintain a temperature between 0° and 45° Celsius (32° and 113° Fahrenhe it)
and not exceed 95 percent maximum humidity (non-condensing) at any time.
Be sure to allow adequate room for proper air ventilation at the front, back, and sides of the switch.
Refer to “Airflow Considerations” on page 2-3 for minimum clearance requirements. No clearance is necessary at the top or bottom of the chassis.
Electrical Requirements
Note. Alcatel-Lucent switches must be installed by a professional installer. It is the responsibility of the installer to ensure that proper grounding is available and that the installation meets applicable local and national electrical codes.
OmniSwitch 6250 switches have the following general electrical requirements:
Each switch requires one grounded electrical outlet for the chassis power supply. OmniSwitch 6250
switches offer AC power supply support only. Refer to the following chapters for more information.
Each supplied AC power cord is 2 meters (approx. 6.5 feet). Do not use extension cords.
Redundant AC Power. It is recommended that each AC outlet resides on a separate circuit. With
redundant AC, if a single circuit fails, the switch’s remaining power supplies (on separate circuits) can remain operational.
OmniSwitch 6250 Hardware Users Guide September 2015 page 2-1
Installing the Hardware Getting Started

Unpacking and Installing the Switch

To protect your switch components from damage, read all unpacking recommendation s and instructions carefully before beginning.
Unpack your OmniSwitch 6250 chassis as close as possible to the location where it will be in stalled.
Items Included
Your OmniSwitch 6250 includes the following items:
OmniSwitch chassis
Transceivers, per order
Rack mount brackets
Country-specific power cord(s)
Assorted instructional cards, anti-static bags and additional packaging
Weight Considerations
The OmniSwitch 6250 chassis weighs approximately 1.72 kg (3.80 lb).
page 2-2 OmniSwitch 6250 Hardware Users Guide September 2015
Getting Started Mounting the Switch
}
}
Rear. 6 inches minimum at rear of chassis.
Front. 6 inches minimum at front of chassis.
Sides. 2 inches minimum at left and right sides.
Airflow Considerations
To ensure proper airflow, be sure that your switch is placed in a well-ventilated area and provide minimum recommended clearance at the front, back and sides of the switch.
Never obstruct chassis air vents.
Chassis Top View
Note. Clearance is not required at the top and bottom of the chassis.

Mounting the Switch

For information on mounting OmniSwitch 6250 switches, refer to Chapter 3, “OmniSwitch 6250 Chassis and
Hardware Components.”
OmniSwitch 6250 Hardware Users Guide September 2015 page 2-3
Connections and Cabling Getting Started

Connections and Cabling

Once your switch is properly installed, you should connect all network and management cables required for your network applications. Connections may include:
DB9-to-RJ-45 cable to the console connector
Cables to 10/100/1000 Ethernet or SFP ports
Note. For additional information on cabling connections, refer to the OmniSwitch AOS Release 6 Switch
Management Guide.

Serial Connection to the Console Port

The console port provides a serial connection to the switch using a USB connector and is required when logging into the switch for the first time. By default, this connector provides a DCE console connection.

Serial Connection Default Settings

baud rate 9600 parity none data bits (word size) 8 stop bits 1
For information on modifying these settings, refer to the OmniSwitch AOS Release 6 Switch Management Guide.
page 2-4 OmniSwitch 6250 Hardware Users Guide September 2015
Getting Started Booting the Switch

Booting the Switch

Now that you have installed the switch components and connected network and management cables, you can boot the switch. To boot the switch, plug the po wer supply cord into an easily-accessible, properly grounded power outlet. (Do not use extension cords.) The switch will power on and boot automatically.

Component LEDs

During the boot process, component LEDs will flash and change color, indi cating different stages of the boot. Following a successful boot, chassis LEDs should display as follows:
OK1 Solid Green PRI Solid Green PWR Solid Green
Note. If the LEDs do not display as indicated, make sure the boot process is complet e. If t he LEDs do not
display as indicated following a complete boot sequence, contact Alcatel-Lucent Customer Support. For information on LED states, refer to “Chassis Status LEDs” on page 3-19.
Once the switch has completely booted and you have accessed your computer’s terminal emulation software via the console port, you are ready to lo g in to the switch’s Command Line Interface (CLI) and configure basic information. Continue to “Your First Login Session” on page 2-6.
OmniSwitch 6250 Hardware Users Guide September 2015 page 2-5
Your First Login Session Getting Started

Your First Login Session

In order to complete the setup process for the switch, you must complete the following steps during your first login session:
Log in to the switch
Unlock session types
Change the login password
Set the date and time
Set optional system information
Save your changes
Important. You must be connected to the switch via the console port before initiating your first
login session.

Logging In to the Switch

When you first log in to the switch, you will be prompted for a login name and password. Use the switch’s default settings:
Login: admin
Password: switch
The default welcome banner, which includes informatio n such as the current software version and system date, is displayed followed by the CLI command prompt:
Welcome to the Alcatel-Lucent OmniSwitch 6250 Software Version 6.7.1.80.R01 Development, July 08, 2015.
Copyright(c), ALE USA Inc., 2015. All Rights reserved.
OmniSwitch(TM) is a trademark of Alcatel-Lucent Enterprise registered in the United States Patent and Trademark Office.
->
Note. A user account includes a login name, password, and user privileges. Privileges determine whether the user has read or write access to the switch and which commands the user is authorized to execute. For detailed information on setting up and modifying user accounts, refer to the OmniSwitch AOS Release 6
Switch Management Guide.
page 2-6 OmniSwitch 6250 Hardware Users Guide September 2015
Getting Started Your First Login Session

Unlocking Session Types

Security is a key feature on OmniSwitch 6250 switches. As described on page 2-6, when you access the switch for the first time, you must use a direct console port connection. All other session types (Telnet, FTP, WebView, and SNMP) are locked out until they are manually unlocked by the user.
The CLI command used to unlock session types is aaa authentication.
Note. When you unlock session types, you are granting switch access to non-local sessions (e.g., Telnet). As a result, users who know the correct user login and password will have remote access to th e switc h. For more information on switch security, refer to the OmniSwitch AOS Release 6 Switch Management Guide.
Unlocking All Session Types
To unlock all session types, enter the following command syntax at the CLI prompt:
-> aaa authentication default local
Unlocking Specified Session Types
You can also unlock session types on a one-by-one basis. For example, to unlock Telnet sessions only, enter the following command:
-> aaa authentication telnet local
To unlock WebView (HTTP) sessions only, enter the following command:
-> aaa authentication http local
You cannot specify more than one session type in a single command line. However, you can still unlock multiple session types by using the aaa authentication command in succession. For example:
-> aaa authentication http local
-> aaa authentication telnet local
-> aaa authentication ftp local
Refer to the OmniSwitch CLI Reference Guide for complete aaa authentication command syntax options.
OmniSwitch 6250 Hardware Users Guide September 2015 page 2-7
Your First Login Session Getting Started

Changing the Login Password

Change the login password for admin user sessions by following the steps below:
1 Be sure that you have logged into the switch as user type admin (see “Logging In to the Switch” on
page 2-6).
2 Enter the keyword password and press Enter. 3 Enter your new password at the prompt.
Note. Be sure to remember or securely record all new passwords; overriding configured passwords on an
OmniSwitch is restricted.
4 You will be prompted to re-enter the password. Enter the password a second time.
New password settings are automatically saved in real time to the local user database; the user is not required to enter an additional command in order to save the password information. Also note that new password information is retained following a reboot. All subsequent login sessions, including those through the console port, will require the new password to access the switch.
For detailed information on managing login information, including user names and passwords, refer to the OmniSwitch AOS Release 6 Switch Management Guide.

Setting the System Time Zone

The switch’s default time zone is UTC. If you require a time zone that is spe cifi c to y ou r region , or if you nee d to enable Daylight Savings Time (DST) on the switch, you can configure these settings via the system timezone and system daylight-savings-time commands.
For detailed information on configuring a time zone for the switch, refer to the OmniSwitch AOS Release 6 Switch Management Guide.

Setting the Date and Time

Set the current time for the switch by entering system time, followed by the current time in hh:mm:ss.
To set the current date for the switch, enter system date, followed by the current date in mm/dd/yyyy.
page 2-8 OmniSwitch 6250 Hardware Users Guide September 2015
Loading...
+ 146 hidden pages