The Ether-GSH2404W, 24x10/100/1000Base-TX plus 4 x Mini-GBIC Web Managed
Switch, is a multi-port Switch that can be used to build high-performance switched
workgroup networks. This switch is a store-and-forward device that offers low latency
for high-speed networking. The switch is targeted at workgroup, department or
backbone computing environment.
The Ether-GSH2404W has 24 auto-sensing 10/100/1000 Base-TX RJ-45 ports and 4
Mini-GBIC slots for higher connection speed.
1.1 Features
Conform to IEEE802.3 10BASE-T, IEEE802.3u 100BASE-TX Fast Ethernet, IEEE
802.3ab 1000Base-T, IEEE 802.3z Gigabit Fiber, IEEE802.3x Flow control and
Back pressure, IEEE802.1d Spanning tree protocol, IEEE 802.s Rapid Spanning
Tree, IEEE 802.3ad Port trunk with LACP, IEEE802.1p Class of service,
IEEE802.1Q VLAN Tagging
Store-and-Forward Switching Architecture
Auto-MDIX on all ports
48Gbps Back-Plane
8K MAC Address Table
500Kbytes memory buffer
N-Way Auto-Negotiation
True Non-Blocking Switching
10K Jumbo Frame support
Back Pressure with half duplex
Flow Control with full duplex
Support Port Based VLAN and Tag VLAN
Support IGMP Snooping
Support Class of Service
Support Port Mirror
Support Port Trunk
1
AirLive Ether-GSH2404W User’s Manual
Page 5
1. Introduction
Support Rapid Spanning Tree
Supports ingress packet filter and egress rate limit
Support IP address security to prevent unauthorized intruder
Provides Web interface management and one default button for system default
setting
Support Bandwidth control
1.2 Software Feature
Management
Firmware update
Port
configuration
Port Trunk
Port statistics
Web Management
TFTP firmware upgrade
Port enable/disable
Port speed
Full /half duplex
Flow control
IEEE802.3ad port trunk with link aggregation control
protocol (LACP)
The trunk group up to 8 and maximum trunk port member
up to 24 ports
Several of counters for TX and RX packet.
Port based VLAN
VLAN
Quality of
Service
Class of Service
AirLive Ether-GSH2404W User’s Manual
Tag VLAN and GVRP protocol
The VLAN entry up to 4K and VID up to 4094
Port based
Tag based
IPv4 ToS
IPv6 DSCP
Per port support 4 priority queues
2
Page 6
1. Introduction
Spanning Tree
Port Mirror
IGMP
Broadcast Storm
Bandwidth
Control
IEEE802.1w rapid spanning tree
Compatible with IEEE 802.1d
RX packet mirror
IGMP V1, V2
Multicast groups up to 8K
Disable /5%/10%/20%
Per port support Bandwidth control. Per level 128 Kbps.
AirLive Ether-GSH2404W User’s Manual
3
Page 7
1. Introduction
1.3 Package Contents
Unpack the contents of the
Ether-GSH2404W
and verify them against the
checklist below:
24x10/100/1000Base-TX plus 4 x Mini-GBIC Web Managed Switch
Power Cord
Four Rubber Pads
QIG
CD
Rack-mounted kit
Switch
Four Rubber Pads CD
Rack-mounted Kit Power Cord QIG
Compare the contents of your Ether-GSH2404W package with the standard checklist
above. If any item is missing or damaged, please contact the local dealer for service.
AirLive Ether-GSH2404W User’s Manual
4
Page 8
2. Hardware Description
Chapter 2: Hardware Description
This section mainly describes the hardware of Ether-GSH2404W and gives a physical
and functional overview on the certain switch.
2.1 Physical Dimension
Ether-GSH2404W’s physical dimensions is
440mm x 161mm x 44mm (Lx W x H).
2.2 Front Panel
The Front Panel of the Ether-GSH2404W consists of 24x 10/100/1000 Base-TX RJ-45
ports (Auto MDI/MDIX) and 4 Mini GBIC slots which can insert the Mini Gigabit Fiber
module (optional). The LED Indicators are also located on the front panel of the switch.
The Front panel of Ether-GSH2404W
RJ-45 Ports (Auto MDI/MDIX): 24x 10/100/1000 N-way auto-sensing for
10Base-T or 100Base-TX or 1000Base-T connections.
In general,
connecting to a workstation or PC. Therefore,
connecting to another Switch or workstation without changing non-crossover or
crossover cabling.
4 MINI GBIC slot: 4 slots for inserting the mini GBIC module that is optional.
means connecting to another Hub or Switch while
MDI
Auto MDI/MDIX
AirLive Ether-GSH2404W User’s Manual
5
means
MDIX
would allow
Page 9
2. Hardware Description
2.3 LED Indicators
The LED Indicators display real-time information of systematic operation status. The
following table provides descriptions of LED status and their meaning.
LED indicators
LED Status Description
GreenPower On
z
Power
Off Power is not connected
LNK/ACT
1000 z
LNK/ACT (Mini GBIC)
GreenThe port is connecting with the device.
z
Blink The port is receiving or transmitting data.
Off No device attached.
GreenIn 1000Mbps connection speed
GreenThe port is connecting with the device.
z
Blink The port is receiving or transmitting data.
Off No device attached
The Description of LED Indicators
AirLive Ether-GSH2404W User’s Manual
6
Page 10
2. Hardware Description
2.4 Rear Panel
The 3-pronged power plug is located at the rear Panel of Ether-GSH2404W as shown
in figure. The switch will work with AC in the range of 100-240V AC, 50-60Hz.
The Rear Panel of Ether-GSH2404W
2.5 Desktop Installation
Set the switch on a sufficiently large flat space with a power outlet nearby. The surface
where you put the switch should be clean, smooth, level and sturdy. Make sure there is
enough clearance around the switch to allow attachment of cables, power cord and
allow air circulation.
2.5.1 Attaching Rubber Pads
A. Make sure mounting surface on the bottom of the switch is grease and dust free.
B. Remove adhesive backing of Rubber Pads.
C. Apply the Rubber Pads to each corner on the bottom of the switch and these
footpads can prevent the switch from shock/vibration.
2.6 Rack-mounted Installation
Ether-GSH2404W come with a rack-mounted kid and can be mounted in an EIA
standard size/19-inch Rack. The switch can be placed in a wiring closet with other
equipment.
Perform the following steps to rack mount the switch:
1. Position one bracket to align with the holes on one side of the switch and secure it
AirLive Ether-GSH2404W User’s Manual
7
Page 11
2. Hardware Description
with the smaller bracket screws. Then attach the remaining bracket to the other
side of the switch.
2. After attached mounting brackets, position the 24 10/100/1000TX plus 4 Mini
GBIC Web Managed switch in the rack by lining up the holes in the brackets with
the appropriate holes on the rack. Secure the switch to the rack with a screwdriver
and the rack-mounting screws.
[NOTE]
For proper ventilation, allow about at least 4 inches (10 cm) of clearance on
the front and 3.4 inches (8 cm) on the back of the Switch. This is especially important
for enclosed rack installation.
2.7 Power On
Connect the power cord to the power socket on the rear panel of the switch. The other
side of power cord connects to the power outlet. The internal power supply of the
switch works with voltage range of AC in the 100-240VAC, frequency 50~60Hz. Check
the power indicator on the front panel to see if power is properly supplied.
AirLive Ether-GSH2404W User’s Manual
8
Page 12
3. Network Application
Chapter 3: Network Application
This section provides few samples of network topology in which the switch used. In
general, Ether-GSH2404W is designed as a segment switch. That is, with its large
address table (8K MAC address) and high performance, it is ideal for interconnecting
networking segments.
PC, workstations and servers can communicate each other by directly connecting with
Ether-GSH2404W. The switch automatically learns nodes address, which are
subsequently used to filter and forward all traffic based on the destination address.
By using Uplink port, the switch can connect with another switch or hub to interconnect
other small-switched workgroups to form a larger switched network. Meanwhile, you
can also use fiber ports to connect switches.
3.1 Small Workgroup
Ether-GSH2404W can be used as a standalone switch for personal computers, server
and printer server which are directly connected to form a small workgroup.
AirLive Ether-GSH2404W User’s Manual
9
Page 13
3. Network Application
3.2 Segment Bridge
For enterprise networks where large data broadcasts are constantly processed, this
switch is an ideal solution for department users to connect to the corporate backbone.
In the illustration below, two Ethernet switches with PCs, print server, and local server
attached, are both connect to the switch. All the devices in this network can
communicate with each other through the switch. Connecting servers to the switch
allow other users to access the data on server.
AirLive Ether-GSH2404W User’s Manual
10
Page 14
3. Network Application
3.3 Internet café / Campus / FTTH
Ether-GSH2404W supports Rate control, QoS, and VLAN features can be used for
Internet Café / Campus / FTTH network.
This Ether-GSH2404W switch is an ideal solution for File/Intranet Server, Game/Video
Server, Network DV Device, PC, Notebook, Multi-Media PC, Wireless Point and
Broadband Router which are directly connected to form a complicated network.
11
AirLive Ether-GSH2404W User’s Manual
Page 15
4. Web-Based Management
Chapter 4: Web-Based Management
This section introduces the configuration and functionality of the Web-Based
management of the certain switch.
4.1 About Web-based Management
On the CPU board of the switch there is an embedded HTML web site residing in flash
memory, which offers advanced management features and allow users to manage the
switch from anywhere in the network through a standard browser such as Microsoft
Internet Explorer.
The Web-Based Management supports Internet Explorer 5.0. And, it is applied with
Java Applets for reducing network bandwidth consumption, enhance access speed
and present an easy viewing screen.
[NOTE]
sockets. In fact, the user has to explicitly modify the browser setting to enable Java
Applets to operate network ports.
By default, IE5.0 or later version does not allow Java Applets to activate
4.2 System Login
The default value as listed below:
IP Address:
Subnet Mask:
192.168.10.1
255.255.255.0
Default Gateway:
Password:
1. Launch the Internet Explorer
2. Key in “http://” + “IP Address of Ether-GSH2404W, ” and then press “
For example http://192.168.10.1
AirLive Ether-GSH2404W User’s Manual
”airlive”
192.168.10.254
12
Enter
”
Page 16
3. Login screen will appear right after
4. Web-Based Management
4. Key in the password as
5. Click
Apply
, and then configuration is ready to be set up
”airlive”
Main Interface
4.3 System Configuration
Display system parameters information as listed below, and the other parameters of
system can be configured as well.
MAC Address: the unique hardware address assigned by manufacturer (default)
S/W Version: the Software Version of Kernel
H/W Version: the Hardware Version of Switch
Active IP Address: Current IP Address
Active Subnet Mask: Current IP Subnet Mask
Active Gateway: Current Gateway
DHCP Server: DHCP Server IP Address
Lease Time Left: DHCP lease time. After 50% of the lease time has passed, the
client/switch will attempt to renew the lease with the original DHCP server that it
obtained the lease from using a DHCPREQUEST message. Any time the
client/switch boots and the lease is 50% or more passed, the client/switch will
AirLive Ether-GSH2404W User’s Manual
13
Page 17
4. Web-Based Management
attempt to renew the lease. At 87.5% of the lease completion, the client/switch will
attempt to contact any DHCP server for a new lease.
DHCP Enable:
Fallback IP Address:
Enable DHCP Client Function
192.168.10.1
Fallback Subnet Mask:
Fallback Gateway:
192.168.10.254
Management VLAN:
SNMP, and Web browse can be used to managed the switch from remote side
only when the port of VLAN group ID is equal to the Management VLAN ID)
AirLive Ether-GSH2404W User’s Manual
System Configuration Interface
Assigning the Switch IP address. The default IP is
Assigning the Switch IP Subnet Mask
Assigning the Switch Gateway. The default value is
It is used for Remote Management Security(in fact, the
14
Page 18
4. Web-Based Management
Name:
Password:
Inactivity Timeout:
Click
Or, Click
The name of the switch
Web GUI login password(The default password is root)
timeout time for the web connection
Apply
to activate the configuration
Refresh
to reset the configuration before applying
4.4 Port Configuration
Configure the Status of Ports
Link:
which the system will auto detects the connecting speed
Mode:
“Down” means “No Link”. User can select the link speed or auto speed
Set the speed, full-duplex or half-duplex mode of the ports
Flow control:
Set Flow Control Function as “enable” or “disable” in Full Duplex
mode
MaxFrame(1518 ~ 9600):
the Maximum Frame Size that in bytes from frames
received on the port. Tagged frames are allowed to be 4 Bytes longer than the
Maximum Frame size
Drop frames after excessive collisions:
When the collision packets over the
limit, then the frame will be dropped
Click
Or, click
Apply
Refresh
to apply the configuration
to reset the configuration before applying
15
AirLive Ether-GSH2404W User’s Manual
Page 19
4. Web-Based Management
AirLive Ether-GSH2404W User’s Manual
Port Configuration interface
16
Page 20
4. Web-Based Management
4.5 VLAN Setting
A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain,
which would allows user to isolate network traffic so only the members of VLAN will
receive traffic from the same members of VLAN. Basically, creating a VLAN from a
switch is logically equivalent of reconnecting a group of network devices to another
Layer 2 switch. However, all the network devices are still plugged into the same switch
physically.
Assigning the VLAN ID by inputting a number (from 1~4095) into the VID text-box
Grouping the members of VLAN by checking the check-box to make the selection
Click
Apply
to bring up the configuration interface as below:
VLAN Setting interface
17
AirLive Ether-GSH2404W User’s Manual
Page 21
4. Web-Based Management
4.5.1 VLAN Port Setting
Click
VLAN Port Setting
to bring up the configuration interface for adjusting the
VID Setting
PVID:
Awareness:
Enter the Port VLAN ID
¾ Enable: Transmit to the PVID group that the same with the packets’ VID.
¾ Disable: Transmit to the PVID group that the same with the incoming port’s
PVID.
Frame Type:
¾ Tag: Only allow tagged frame pass the port.
¾ All: Allow all type of frames pass through.
Click
Or, click
Apply
Refresh
to apply the configuration
to reset the configuration before applying
AirLive Ether-GSH2404W User’s Manual
18
Page 22
4. Web-Based Management
VLAN Port Setting interface
4.6 Aggregation
Port trunk allows multiple links to be bundled together and act as a single physical link
for increased throughput. It provides load balancing and redundancy of links in a
switched inter-network. Actually, the link does not have an inherent total bandwidth
equal to the sum of its component physical links. Traffic in a trunk is distributed across
an individual link within the trunk in a deterministic method that called a hash algorithm.
Traffic pattern on the network should be considered carefully before applying it. When
AirLive Ether-GSH2404W User’s Manual
19
Page 23
4. Web-Based Management
a proper hash algorithm is used, traffic is kind of randomly decided to be transmitted
across either link within the trunk and load balancing will be seen.
Select the group members( Normal means the port is not the trunk port)
Click
Or, click
Apply
Refresh
to apply the configuration
to reset the configuration before applying
Aggregation interface
4.7 LACP Setting
The Link Aggregation Control Protocol (LACP) provides a standardized which means
for exchanging information between Partner Systems on a link to allow their Link
Aggregation Control instances to reach agreement on the identity of the Link
Aggregation Group to which the link belongs, move the link to that Link Aggregation
Group, and enable its transmission and reception functions in an orderly manner. Link
aggregation allow user grouping up to eight consecutive ports into a single dedicated
connection. This feature can expand bandwidth to a device on the network.
operation requires full-duplex mode,
802.3ad.
more detail information refers to IEEE
LACP
AirLive Ether-GSH2404W User’s Manual
20
Page 24
4. Web-Based Management
Protocol Enabled:
Key Value:
together
Click
Or, click
Apply
LACP Setting interface
To enable the LACP protocol of the port
The LACP key determines which ports potentially can be aggregated
to apply the configuration
Refresh
to reset the configuration before applying
AirLive Ether-GSH2404W User’s Manual
21
Page 25
4. Web-Based Management
4.8 Rapid Spanning Tree
The Rapid Spanning Tree Protocol (RSTP) is an evolution of the Spanning Tree
Protocol and provides the faster spanning tree convergence after the topology change.
The system also supports STP and the system will auto detect the connected device
that is running STP or RSTP protocol.
4.8.1 RSTP System Configuration
System Priority:
The bridge with the lowest value has the highest priority and is
selected as the root whenever the value is changed, the system must be rebooted
for assigning the priority number of paths. The value must be multiple of 4096
according to the protocol standard rule.
Hello Time (1-10):
The scale of 1~10 sec will be set as a period of time that how
often the switch broadcasts hello messages to other switches
Max Age (6-40):
The number of seconds (from 6~ 40) which determines the
amount of time that protocol information received on a port is stored by the switch.
Forward Delay Time (4-30):
The number of seconds (from 4 ~ 30) which
determines how long each of the listening and learning states will last before the
port begins forwarding.
Force version:
Select the RSTP default protocol. Normal means RSTP protocol.
Compatible means compatible with STP protocol.
AirLive Ether-GSH2404W User’s Manual
22
Page 26
4. Web-Based Management
RSTP Configuration interface
AirLive Ether-GSH2404W User’s Manual
23
Page 27
4. Web-Based Management
4.8.2 RSTP Port Configuration
Protocol Enabled:
Edge:
The port directly connected to end stations cannot create bridging loop in
the network. To configure the port as an edge port, mark the port
Path Cost:
The cost of the path to the other bridge from this transmitting bridge at
To Enable or disable the port protocol
the specified port. Enter a number 1 through 200000000
Click
Or, click
Apply
Refresh
to apply the configuration
to reset the configuration before applying
4.9 802.1X Configuration
802.1x is an IEEE authentication feature which allows a client connecting to a wireless
access point or wired switch, however, prevents the client from gaining access to the
Internet until it provides credentials, like a user name and password that are verified by
a separated server.
Mode:
RADIUS IP:
RADIUS UDP Port:
To disable or enable 802.1x protocol
Set the Radius Server IP address
Set the UDP destination port for authentication requests to
the specified Radius Server
RADIUS Secret:
Set an encryption key for use during authentication sessions
with the specified radius server. This key must match the encryption key used on
the Radius Server
Admin State:
¾
Force Authorized:
Select the state of port
The specified port is required to be held in the
unauthorized state
¾
Force Unauthorized:
The specified port is required to be held in the
authorized state
¾
Auto:
The specified port is set to the authorized or unauthorized state in
accordance with the outcome of an authentication exchange between the
Supplicant and the authentication server
AirLive Ether-GSH2404W User’s Manual
24
Page 28
4. Web-Based Management
802.1X Configuration interface
Re-authenticate:
Force Reinitialize:
Statistics:
Re-authenticate All:
Force reinitialize All:
Click to view each port statistic
Restart authentication process for the port
Restart authentication process for the port
Restart authentication process for all the port
Restart authentication process for all the port
AirLive Ether-GSH2404W User’s Manual
25
Page 29
4. Web-Based Management
Click
Or, click
Apply
Refresh
to apply the configuration
to reset the configuration before applying
4.9.1 Parameters Configuration
Reauthentication Enabled:
Reauthentication period (1~3600 seconds):
clients connected must be re-authenticated
EPA Timeout (1~255 seconds:
supplicant response to an EAP request
Click
Or, click
Apply
Refresh
to apply the configuration
to reset the configuration before applying
Enable the re-authentication mode
Set the period of time the switch waits for a
Set the period of time after which
4.10 IGMP Snooping
The Internet Group Management Protocol (IGMP) is an internal protocol of the Internet
Protocol (IP) suite. IP manages multicast traffic by using switches, routers, and hosts
that support IGMP. Enabling IGMP allows the ports to detect IGMP queries and report
packets and manage IP multicast traffic through the switch.
The switch support IP multicast that IGMP protocol can be enabled on switch then
displays the IGMP snooping information. IP multicast addresses range from 224.0.0.0
AirLive Ether-GSH2404W User’s Manual
26
Page 30
through 239.255.255.255.
4. Web-Based Management
IGMP Enable:
Router Ports:
To enable or disable IGMP function
A static router port. It is a port that has a multicast router, which has
a connection to the internet, attached to it. Selecting a router port will allow
multicast packets coming from the router to be propagated through the network,
as well as allowing multicast messages (IGMP) coming from the network to be
propagated to the router. All IGMP Report packets will be forwarded to the router
port, and IGMP queries (from the router port) will be flooded to all ports. All UDP
multicast packets will be forwarded to the router port because routers do not send
IGMP reports or implement IGMP snooping.
Unregistered IPMC Flooding Enable: To
flooding
enable unregistered IP multicast
IGMP Snooping Enabled: To enable or disable the IGMP protocol of VLAN group
Quick Search VLAN Entry, VLAN ID: Enter the VLAN ID number to quick search
the VLAN group.
Click
Apply
Or, click
to apply the configuration
Refresh
to reset the configuration before applying
IGMP Snooping interface
AirLive Ether-GSH2404W User’s Manual
27
Page 31
4. Web-Based Management
4.11 QoS Setting
Configuring QoS mode of the port, per port priority, TOS and COS priority setting.
Mode:
Port Priority:
Click
Click
Select the QoS mode – port, DSCP or vlantag
select the priority level – low, normal, medium or high
Apply
Refresh
to apply the configuration
to reset the configuration before applying
Click
VLAN tag Mapping
QoS Configuration interface
to enter VLAN tag priority configuration interface.
Select the VLAN tap priority level 0~7
AirLive Ether-GSH2404W User’s Manual
28
Page 32
4. Web-Based Management
Click
Or, click
Apply
Refresh
to apply the configuration
to reset the configuration before applying
Click
QoS VLAN Tag Priority Mapping interface
DSCP Mapping
to enter TOS priority configuration interface
¾
DSCP [0- 63]:
the system provides 0~63 TOS priority level. When the IP
packet is received, the system will check the TOS level value in the IP packet
that has received. For example: user set the TOS level 25 is high. The port 1
is following the TOS priority policy. When the packet received by port 1, the
system will check the TOS value of the received IP packet. If the TOS value of
received IP packet is 25(priority = high), and then the packet priority will have
AirLive Ether-GSH2404W User’s Manual
29
Page 33
4. Web-Based Management
highest priority
¾
Priority:
Click
Or, press
Apply
Refresh
select the priority level – high, medium, low or normal
to apply the configuration
to reset the configuration before applying
QoS DSCP Mapping interface
4.12 Filter Configuration
Filter the specific IP address on port that it can ensure the network security.
Mode:
¾
¾
IP Address:
IP Mask:
DHCP Server Allowed:
Select the mode – DHCP or Static
DHCP:
If the port is DHCP client enabling, the IP Address will automatically
display in IP Address column
Static:
Key in a specific IP Address and IP Mask for filtering
Key in the specific IP Address to filter
Key in the IP Mask of the IP Address
Allowing DHCP server packet to pass through this port
AirLive Ether-GSH2404W User’s Manual
30
Page 34
4. Web-Based Management
Click
Or, press
Apply
Refresh
to apply the configuration
to reset the configuration before applying
Filter Configuration interface
31
AirLive Ether-GSH2404W User’s Manual
Page 35
4. Web-Based Management
4.13 Rate Limiting
Storm Control:
The traffic storm control prevents LAN ports from being disrupted
by a broadcast, multicast, or unicast traffic storm on physical interfaces.
9
ICMP Rate:
9
Learn Frames Rate:
Select the ICMP traffic storm control rate
The learn frame rate is that the packet rate is learned
and unicast. Learn Frames Rate is to find the Ethernet transfer rate but for the
un-learn and flooding packets rate are no effect.
9
Broadcast Rate:
9
Multicast Rate:
9
Flooded unicast Rate:
Policer:
Sharper:
Click
Or, press
Enter the port effective egress rate
Enter the port effective ingress rate
Apply
to apply the configuration
Refresh
Select the broadcast traffic storm control rate
Select the multicast traffic storm control rate
Select the unicast traffic rate
to reset the configuration before applying
AirLive Ether-GSH2404W User’s Manual
32
Page 36
4. Web-Based Management
Rate Limit Configuration interface
AirLive Ether-GSH2404W User’s Manual
33
Page 37
4. Web-Based Management
4.14 Port Mirroring
The Port mirroring is a method for monitor traffic in switched networks. Traffic through
ports can be monitored by one specific port. That is, traffic goes in or out monitored
ports will be duplicated into analysis port.
Analysis Port:
It means mirror port can be used to see all monitor port traffic.
( Mirror port can be connected to LAN analyzer or Netxray)
Monitor Port:
the ports which wants to be monitored. All monitor port traffic will be
copied to analysis port. Maximum 23 monitor ports can be selected.
Click
Or, press
Apply
Refresh
to apply the configuration
to reset the configuration before applying
AirLive Ether-GSH2404W User’s Manual
Port Mirroring Configuration interface
34
Page 38
4.15 Statistics Overview
The following information provides the current port statistic information
4. Web-Based Management
Press
Clear
button to clean all counts, and then click
setting information as below:
Refresh
to get the new
Statistics Overview interface
35
AirLive Ether-GSH2404W User’s Manual
Page 39
4. Web-Based Management
4.16 Statistics Detail
The following information provides statistic detail information of statistic on each port,
and simply selecting the port to viewing the statistic information.
Press
Clear
button to clean all counts, and then click
setting information as below:
Refresh
to get the new
AirLive Ether-GSH2404W User’s Manual
Statistics Detail interface
36
Page 40
4. Web-Based Management
4.17 LACP Status
When the LACP aggregator is setup, the related information will be shown as below:
LACP Status interface
AirLive Ether-GSH2404W User’s Manual
37
Page 41
4. Web-Based Management
4.18 Spanning Tree Status
Click
Refresh
to get the newest configuration information. The Rapid Spanning
Tree Protocol information will display as below:
AirLive Ether-GSH2404W User’s Manual
RSTP Status interface
38
Page 42
4.19 IGMP Status
IGMP Snooping information will be shown as below:
4. Web-Based Management
IGMP Status interface
4.20 Warm Restart
Reboot the switch in software reset. All the configurations will be reminded
Yes
Click
to restart the system
System Restart interface
AirLive Ether-GSH2404W User’s Manual
39
Page 43
4. Web-Based Management
4.21 Factory Default
Reset switch to default configuration
Click
Yes
to reset the all configuration to the default value
Factory Default interface
4.22 Firmware Upload
The system provides the Web GUI firmware update function which would allow the
user to update the switch firmware
Click
Browse
to locate the firmware and press
Upload
to update the firmware
Firmware Upload interface
AirLive Ether-GSH2404W User’s Manual
40
Page 44
4.23 Configuration File Transfer
User can restore configuration value through the WEB GUI
4. Web-Based Management
Click
And then, press
Browse
to locate the configuration value file
Upload
to restore the configuration value
Configuration File Transfer interface
To backup the configuration value
Click
Download
, and then follow the system instruction which will guide user
to complete the configuration value download
41
AirLive Ether-GSH2404W User’s Manual
Page 45
5. Troubleshooting
Chapter 5: Troubleshooting
This section is intended to help user to solve the most common problems on the
Ether-GSH2404W 24x10/100/1000TX plus 4 Mini-GBIC Web Managed Switch.
5.1 Incorrect connections
The switch port can auto detect straight or crossover cable when the switch link with
other Ethernet device. For the RJ-45 connector should use correct UTP or STP cable,
10/100Mbps port use 2 pairs twisted cable and Gigabit 1000T port use 4 pairs twisted
cable. If the RJ-45 connector is not correct pin on right position then the link will fail.
For fiber connection, please notice that fiber cable mode and fiber module should be
match.
Faulty or loose cables
Look for loose or obviously faulty connections. If they appear to be OK, make sure the
connections are snug. If that does not correct the problem, try a different cable.
Non-standard cables
Non-standard and miss-wired cables may cause numerous network collisions and
other network problem, and can seriously impair network performance. A category-5
cable tester is a recommended tool for every 100Base-T network installation.
RJ-45 ports:
RJ-45 connections: 100
Category 5 cable for 100Mbps connections. Also be sure that the length of any
twisted-pair connection does not exceed 100 meters (328 feet). Gigabit port should
use Cat-5 or cat-5e cable for 1000Mbps connections. The length does not exceed 100
meters.
use unshielded twisted-pair (UTP) or shield twisted-pair ( STP ) cable for
Ω
Category 3, 4 or 5 cable for 10Mbps connections or 100Ω
AirLive Ether-GSH2404W User’s Manual
42
Page 46
5. Troubleshooting
Improper Network Topologies
It is important to make sure that user have a valid network topology. Common topology
faults include excessive cable length and too many repeaters (hubs) between end
nodes. In addition, user should make sure that network topology contains no data path
loops. Between any two ends nodes, there should be only one active cabling path at
any time. Data path loops will cause broadcast storms that will severely impact network
performance.
5.2 Diagnosing LED Indicators
The switch can be easily monitored through panel indicators to assist in identifying
problems, which describes common problems you may encounter and where user can
find possible solutions.
If the power indicator does turn on when the power cord is plugged in, user may have a
problem with power outlet, or power cord. However, if the switch powers off after
running for a while check for loose power connections, power losses or surges at
power outlet. If the problem still cannot be resolved, contact the local dealer for
assistance.
43
AirLive Ether-GSH2404W User’s Manual
Page 47
6. Technical Specification
Chapter 6: Technical Specification
This section provides the specifications of Ether-GSH2404W 24x10/100/1000TX plus
4 Mini-GBIC Web Managed Switch and the following table lists these specifications.
IEEE 802.3 10BASE-T Ethernet
IEEE 802.3u 100BASE-TX Fast Ethernet
IEEE 802.3ab 1000Base-T
IEEE 802.3z Gigabit Fiber
IEEE 802.3x Flow Control and Back-pressure
Standard
IEEE 802.1d Spanning Tree
IEEE 802.w Rapid Spanning Tree
Network Cable
LED Indicators
IEEE 802.3ad Port trunk with LACP
IEEE 802.1p Class of Service
IEEE 802.1Q VLAN Tag
10BASE-T: 2-pair UTP/STP Cat. 3, 4, 5 cable
EIA/TIA-568 100-ohm (100m)
100BASE-TX: 2-pair UTP/STP CAT. 5 cable
EIA/TIA-568 100-ohm (100m)
Gigabit Copper: 4 pair UTP/STP CAT. 5 cable
EIA/TIA 568 100-ohm (100M)
Per RJ-45 port: 1000 (green), Link/Activity (green)
Per MINI GBIC: Link/Activity (Green)
Per unit: Power
Connector
AirLive Ether-GSH2404W User’s Manual
Gigabit copper: 24 x RJ-45 with Auto-MDIX
MINI GBIC: 4 x MINI GBIC socket (3.3v); shared
with last 4-port RJ-45
44
Page 48
6. Technical Specification
Switch architecture
Jumbo packet
Back-plane
MAC address
Memory Buffer
Power Supply
Power Consumption
(DC)
Store and forward switch architecture
Support 10Kbytes jumbo packet size
48Gbps, 71.42Mpps throughput @64bytes
8K Mac with Auto Learning
500Kbytes
AC 100~240V, 50/60Hz
AC: 65Watt (maximum) DC:19W(maximum)
Dimensions
Operation
Temperature
Operation Humidity
EMI
Safety
440mm x 161mm x 44mm (L x W x H)
0℃ to 45℃ (32℉ to 113℉)
10% to 90% (Non-condensing)
FCC Class A, CE
UL, cUL
45
AirLive Ether-GSH2404W User’s Manual
Page 49
7. Appendix
Chapter 7: Appendix
7.1 Cables
The RJ-45 ports on the switch support automatic MDI/MDI-X operation, so you can use
standard straight-through twisted-pair cables to connect to any other network device
(PCs, servers, switches, routers, or hubs). Please refer to the following table for cable