Safety Instructions Do not attempt to service the product yourself. Any
servicing of this product should be referred to qualified service personal.
To avoid electric shock, do not put your finger, pin, wire, or any other metal
objects into vents and gaps.
To avoid accidental fire or electric shock, do not twist power cord or place it
under heavy objects.
The product should be connected to a power supply of the type described in
the operating instructions or as marked on the product.
To avoid hazard to children, dispose of the product’s plastic packaging
carefully.
Please read all the instructions before using this product.
- 2 -
Safety Notices
These are the safety considerations for using the AirLive ePhone-1000. Read these notices before
installing or using the phone.
Warning This warning symbol means danger. You are in a situation that could cause bodily injury.
Before you work on any equipment, be aware of the hazards involved with electrical circuitry and
be familiar with standard practices for preventing accidents. To see translations of the warnings that
appear in this publication, refer to the Regulatory Compliance and Safety Information document
that accompanied this device.
Warning Read the installation instructions before you connect the s yste m to i ts p ow e r so urc e.
Warning Ultimate disposal of this product should be handled according to all national laws and
regulations.
Warning Do not work on the system or connect or disconnect cables during periods of lightning
activity.
Warning To avoid electric shock, do not connect saf ety extra low voltage (SELV) circuits to
telephone network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports
contain TNV circuits. Some LAN and WAN ports use RJ-45 connectors. Use caution when
connecting cables.
The next warning applies when you use an external power supply.
- 3 -
Warning This product relies on the building's installation for short-circuit (over current) protection.
Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 10A
international) is used on the phase conductors (all current-carrying conductors).
Warning The device is designed to work with TN power systems.
- 4 -
Table of Contents
SAFETY NOTICES 3
TABLE OF CONTENTS 5
PRODUCT SPECIFICATIONS 7
PACKAGE CONTENTS 8
AIRLIVE EPHONE-1000 FUNCTIONS 9
Front Panel ................................................................................................................................................ 9
Rear and Back Panel ................................................... ........................................................................... 10
Function Keys .........................................................................................................................................11
HARDWARE INSTALLATION 12
CONFIGURING THE AIRLIVE EPHONE-1000 WITH THE KEYPAD 13
Configuring for DHCP..........................................................................................................................................14
Configuring for Static IP.......................................................................................................................................14
Configuring for PPPoE ........................................................................................................................................15
Other Settings ........................... .............................................................................................................. 19
To make a phone call ............................... ..............................................................................................39
Review call record ..................................................................................................................................39
Hold .......................................................................................... ................................................ ................ 40
APPENDIX 41
FREQUENTLY ASKED QUESTIONS 43
- 6 -
Product Specifications
Voice
Call Control Protocol SIP (RFC-3261) or H.323 V4
Voice Compression G.711 A/µ -Law, G.723.1, G.729A/B/AB
Echo Cancellation G.165 16ms
Delay (Point to Point) < 100ms
Average Bandwidth Requirement 10-12k bit/s
Network Protocol RT P/RTCP, UDP/TCP
Support Silence Suppression
VAD, CNGAcoustic Echo CancellationJitter Buffering
DTMF tone detection
E.164 Dial plan
Network Interface
Interface 10 Base-T Ethernet
Connectors Type RJ-45 connector
Configuration Tools
IP Address Support PPPoE, DHCP client/Static IP
Firmware Upgrade FTP/HTTP
Other Information
Headset Connection InterfaceFirmware Upgrade
NAT Pass-through (SIP with STUN)
Speaker phoneHoldMuteRedialSpeed Dial
Received Calls Misse d CallsDialed CallsCall
StatusVo lume Adjustment Voice Response Web
ConfigurationLED indicator, etc..
- 7 -
Package Contents
The AirLive ePhone-1000 Series VoIP phone package contains:
• One AirLive ePhone-1000 VoIP phone
• One power adaptor
• One RJ-45 Ethernet cable
• Quick Installation Guide
• Installation CD
- 8 -
AIRLIVE EPHONE-1000 Functions
Front Panel
- 9 -
Rear and Back Panel
Power Jack10 Base T Ethernet RJ-45 Jack
Microphone Jack
Wall Mount
Microphone
Earphone Jack
Handset Cord Jack
- 10 -
Function Keys
Keys Function
These keys function with the handset hung
Called
Press the Called key to display the IP address and phone number of the last call
placed.
Ans. Press the Ans. key to display the IP address and phone number of an incoming call.
Miss Press the Miss key to get local IP address of the phone to consult the missed call
number. In addition, dial # to dial this number.
Phone Press the Phone key to get the phone number of the phone. Press again will show
the data in the phone book.
IP With handset hung, press the IP key to get local IP address of the phone.
Mask With handset hung, press the Mask button to get the subnet mask of the AirLive
ePhone-1000.
GATE IP With handset hung, press the GATE IP button to get the gateway IP address in
LAN.
SER .IP With handset hung, press the SER. IP to get the service server IP address.
Hand Free Press this key to turn on the speaker phone.
These keys function at all times
SPD./HOLD Speed Dial; Hold
REDIAL/MUTE Redial; Mute
Vol - Decreases the volume of the handset or speaker; turns the recording back.
Vol + Increases the volume of the handset or speaker; turns the recording back.
- 11 -
Hardware Installation
Plug the power cord into the Power jack of the AirLive ePhone-1000 VoIP
Plug the RJ-45 Ethernet cable into the Ethernet jack.
Plug the other end of other cable into the HUB, Router, ADSL Modem, or other
Phone.
broadband device.
After installing the AirLive ePhone-1000, follow the configuration instructions
in the next chapters.
- 12 -
Configuring the AIRLIVE EPHONE-1000 with the Keypad
AirLive ePhone-1000 can be configured with its keypad or on a web page.
The table below illustrates Configuration Function keys:
Keys Function
SPD./HOLD Change Settings
REDIAL/MUTE Main Menu Options
Vol - Next Page
Vol + Previous Page
Enter Confirm Setting
The Main Menu of the Keypad LCD screen is shown below:
- 13 -
Configuring Network Settings
Network settings allow the AirLive ePhone-1000 to connect to a specific network
environment.
DHCP is the default setting for the AirLive ePhone-1000. This setting enables internet
connections with any DHCP environment.
If either PPPoE or Static IP are used, change the default network setting of AirLive ePhone-1000 to one of these network environments.
Using the keypad you can select DHCP, Sta t ic IP or PPPoE for your network environment
Each of these three options is described below.
Configuring for DHCP
Connect the power adaptor of AirLive ePhone-1000 and connect the PPPoE network
to the RJ-45 port.
Press 1, 2, 3, 4, # (Hold the “#” key)
Enter a [Password]
Press 1, 2, 3, 4 and Enter Æ Network Settings appears.
Press Enter Æ enter the [iptype]
Press SPD/Hold
When the Blinking Cursor appears press 1 and press Enter (1 sets the networking
settings to DHCP).
Configuring for Static IP
Connect the power adaptor to the AirLive ePhone-1000
Connect the PPPoE network to the RJ-45 port.
Press1, 2, 3, 4, # (Hold the “#” key) →enter a [Password]
Press 1, 2, 3, 4 and Enter→ Network Settings appears.
Press Enter→ [iptype] →
Press SPD/Hold→ a Blinking Cursor appears
- 14 -
Loading...
+ 32 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.