AirLive ePhone-1000S User Manual

AirLive ePhone
VOIP IP Phone
User’s manual
1000
Safety Instructions Do not attempt to service the product yourself. Any servicing of this product should be referred to qualified service personal.
To avoid electric shock, do not put your finger, pin, wire, or any other metal objects into vents and gaps.
To avoid accidental fire or electric shock, do not twist power cord or place it under heavy objects.
The product should be connected to a power supply of the type described in the operating instructions or as marked on the product.
To avoid hazard to children, dispose of the product’s plastic packaging carefully.
Please read all the instructions before using this product.
- 2 -
Safety Notices
These are the safety considerations for using the AirLive ePhone-1000. Read these notices before installing or using the phone.
Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. To see translations of the warnings that appear in this publication, refer to the Regulatory Compliance and Safety Information document that accompanied this device.
Warning Read the installation instructions before you connect the s yste m to i ts p ow e r so urc e.
Warning Ultimate disposal of this product should be handled according to all national laws and
regulations.
Warning Do not work on the system or connect or disconnect cables during periods of lightning activity.
Warning To avoid electric shock, do not connect saf ety extra low voltage (SELV) circuits to telephone network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some LAN and WAN ports use RJ-45 connectors. Use caution when connecting cables.
The next warning applies when you use an external power supply.
- 3 -
Warning This product relies on the building's installation for short-circuit (over current) protection.
Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 10A international) is used on the phase conductors (all current-carrying conductors).
Warning The device is designed to work with TN power systems.
- 4 -
Table of Contents
SAFETY NOTICES 3
TABLE OF CONTENTS 5
PRODUCT SPECIFICATIONS 7
PACKAGE CONTENTS 8
AIRLIVE EPHONE-1000 FUNCTIONS 9
Front Panel ................................................................................................................................................ 9
Rear and Back Panel ................................................... ........................................................................... 10
Function Keys .........................................................................................................................................11
HARDWARE INSTALLATION 12
CONFIGURING THE AIRLIVE EPHONE-1000 WITH THE KEYPAD 13
Configuring Network Settings......... ... ... ..... ... .. ...... .. ... ..... ... ... .. ...... .. ... ..... ... ... ..... ... .. ...... .. ... ..... .. ............ 14
Configuring for DHCP..........................................................................................................................................14
Configuring for Static IP.......................................................................................................................................14
Configuring for PPPoE ........................................................................................................................................15
Protocol Settings .................................................................................................................................... 16
Audio Settings................................. ........................................................ ................................................18
Other Settings ........................... .............................................................................................................. 19
Speed Dial Settings .................................................................................. ..............................................20
Revert Back to Factory Default ............................................................................................. ................ 21
Storing Settings ........................................... ...........................................................................................22
- 5 -
Editing Settings............................ ...........................................................................................................23
Saving Settings............................ ... ..... ... .. ...... .. ...... .. ... ..... ... ..... ... ... ..... ... ..... ... .. ...... .. ... ........................... 24
Exit Settings ................................. ...........................................................................................................24
WEB CONFIGURATION 25
NETWORK PARAMETERS 27
PROTOCOL PARAMETERS 28
PHONE PARAMET E RS 32
AUDIO PARAMETERS 35
OTHER PARAMETERS 36
SAVE/REBOOT PARAMETERS 37
Registration Message.............................................................................................................................38
USING AIRLIVE EPHONE-1000 39
To make a phone call ............................... ..............................................................................................39
Review call record ..................................................................................................................................39
Speed Dial................................................................................................................................................39
Mute.......... ................................................................................................................................................40
Hold .......................................................................................... ................................................ ................ 40
APPENDIX 41
FREQUENTLY ASKED QUESTIONS 43
- 6 -
Product Specifications
Voice Call Control Protocol SIP (RFC-3261) or H.323 V4 Voice Compression G.711 A/µ -Law, G.723.1, G.729A/B/AB Echo Cancellation G.165 16ms Delay (Point to Point) < 100ms Average Bandwidth Requirement 10-12k bit/s Network Protocol RT P/RTCP, UDP/TCP Support Silence Suppression
VAD, CNGAcoustic Echo CancellationJitter Buffering DTMF tone detection E.164 Dial plan Network Interface Interface 10 Base-T Ethernet Connectors Type RJ-45 connector Configuration Tools IP Address Support PPPoE, DHCP client/Static IP Firmware Upgrade FTP/HTTP Other Information
Power
Power Consumption 3W
Working Environment
Certification CE, FCC
Other
Web BrowserPhone SettingLCD Monitor
100 – 240VAC, 50 – 60Hz 5VDC, 1A
Operating T emperature0 - 40 (32° - 104°F) Storage T emperature-30 - 6 5 (-22° - 149°F) Relative Humidity10 – 95% Non-Condensing
Headset Connection InterfaceFirmware Upgrade NAT Pass-through (SIP with STUN)
Speaker phoneHoldMuteRedialSpeed Dial Received Calls Misse d CallsDialed CallsCall StatusVo lume Adjustment Voice Response Web ConfigurationLED indicator, etc..
- 7 -
Package Contents
The AirLive ePhone-1000 Series VoIP phone package contains:
One AirLive ePhone-1000 VoIP phone
One power adaptor
One RJ-45 Ethernet cable
Quick Installation Guide
Installation CD
- 8 -
AIRLIVE EPHONE-1000 Functions
Front Panel
- 9 -
Rear and Back Panel
Power Jack 10 Base T Ethernet RJ-45 Jack
Microphone Jack
Wall Mount
Microphone
Earphone Jack
Handset Cord Jack
- 10 -
Function Keys Keys Function These keys function with the handset hung Called
Press the Called key to display the IP address and phone number of the last call
placed. Ans. Press the Ans. key to display the IP address and phone number of an incoming call. Miss Press the Miss key to get local IP address of the phone to consult the missed call
number. In addition, dial # to dial this number. Phone Press the Phone key to get the phone number of the phone. Press again will show
the data in the phone book. IP With handset hung, press the IP key to get local IP address of the phone. Mask With handset hung, press the Mask button to get the subnet mask of the AirLive
ePhone-1000. GATE IP With handset hung, press the GATE IP button to get the gateway IP address in
LAN. SER .IP With handset hung, press the SER. IP to get the service server IP address. Hand Free Press this key to turn on the speaker phone. These keys function at all times SPD./HOLD Speed Dial; Hold REDIAL/MUTE Redial; Mute Vol - Decreases the volume of the handset or speaker; turns the recording back. Vol + Increases the volume of the handset or speaker; turns the recording back.
- 11 -
Hardware Installation
Plug the power cord into the Power jack of the AirLive ePhone-1000 VoIP
Plug the RJ-45 Ethernet cable into the Ethernet jack.
Plug the other end of other cable into the HUB, Router, ADSL Modem, or other
Phone.
broadband device.
After installing the AirLive ePhone-1000, follow the configuration instructions
in the next chapters.
- 12 -
Configuring the AIRLIVE EPHONE-1000 with the Keypad
AirLive ePhone-1000 can be configured with its keypad or on a web page.
The table below illustrates Configuration Function keys:
Keys Function SPD./HOLD Change Settings REDIAL/MUTE Main Menu Options Vol - Next Page Vol + Previous Page Enter Confirm Setting
The Main Menu of the Keypad LCD screen is shown below:
- 13 -
Configuring Network Settings
Network settings allow the AirLive ePhone-1000 to connect to a specific network
environment.
DHCP is the default setting for the AirLive ePhone-1000. This setting enables internet
connections with any DHCP environment.
If either PPPoE or Static IP are used, change the default network setting of AirLive ePhone-1000 to one of these network environments.
Using the keypad you can select DHCP, Sta t ic IP or PPPoE for your network environment
Each of these three options is described below.
Configuring for DHCP
Connect the power adaptor of AirLive ePhone-1000 and connect the PPPoE network
to the RJ-45 port.
Press 1, 2, 3, 4, # (Hold the “#” key)
Enter a [Password]
Press 1, 2, 3, 4 and Enter Æ Network Settings appears.
Press Enter Æ enter the [iptype]
Press SPD/Hold
When the Blinking Cursor appears press 1 and press Enter (1 sets the networking
settings to DHCP).
Configuring for Static IP
Connect the power adaptor to the AirLive ePhone-1000
Connect the PPPoE network to the RJ-45 port.
Press1, 2, 3, 4, # (Hold the “#” key) enter a [Password]
Press 1, 2, 3, 4 and Enter Network Settings appears.
Press Enter [iptype]
Press SPD/Hold→ a Blinking Cursor appears
- 14 -
Press 0 and Enter (0 sets the networking settings to Static IP).
Press Enter again enter the IP address [IP]
Press SPD/Hold→ a blinking cursor appears
Enter the IP address (XXX*XXX*XXX*XXX) and press Enter. Press Enter again the Subnet Mask parameter appears Press SPD/Hold when the blinking cursor appears Enter the Subnet Mask information (XXX*XXX*XXX*XXX) and then press Enter.
Press Enter again the Router option appears
Press SPD/Holdthe blinking cursor appears, Enter the Input Default Gateway Information (XXX*XXX*XXX*XXX) and the press
Enter.
Configuring for PPPoE
Connect the power adaptor to the AirLive ePhone-1000. Connect the PPPoE network to the AirLive ePhone-1000 to its RJ-45 port. Press1, 2, 3, 4, # (Hold the “#” key) enter a [Password] Press 1, 2, 3, 4 and Enter the Network Settings option appears. Press Enter enter the [iptype] Press SPD/Hold When the blinking cursor appears Press 1 and then press Enter(1
sets the networking settings PPPoE). Press Enter againEnter the [pppid] Press SPD/Hold Enter the PPPoE Account Number and press Enter. Press Enter→ Enter the [pppin]
Press SPD/Hold
Enter the PPPoE password and press Enter Press Enter again to complete the configuration
Refer to the appendix when entering special Symbols such as @, A, a, B, b, C
- 15 -
Protocol Settings
To Access the Audio Settings Menu
Press 1, 2, 3, 4, # ( Hold the “#” key) Enter a [Password]
Press 1, 2, 3, 4 and press Enter Network Settings appears
Press Vol.- (volume down button) enter the [Protocol Setting].
To Configure Service Settings
Press Enter twice in the [protocol settings] prompt the Service option appears.
¾ Press SPD/Hold, “0” and Enter to disable service.
¾ Press SPD/Hold, “1” and Enter to enable service.
To Configure the Proxy Server registrar location.
Press Enter multiple times in the [protocol settings] prompt
Enter the [service address]
Press SPD/Hold
Enter the IP address of the registrar proxy server (XXX*XXX*XXX*XXX) and press
Enter.
To Enable STUN for NAT pass-through when using SIP protocol:
At the [protocol settings] prompt of press Enter multiple times the [nat traversal]
prompt appears.
Press SPD/Hold press “4” to enable STUN and press Enter Press Enter again [nat addr] appears
Press SPD/Hold
Enter the IP address of the STUN server (XXX*XXX*XXX*XXX) and press Enter.
To Configure the AirLive ePhone-1000 Registration Type
At the [protocol settings] prompt, press Enter once Press Vol. + (the volume up button) multiple times [local type] appears
- 16 -
Press SPD/Hold
Press “0” to input your telephone number for E.164 to register with the server and press Enter.
Press “1” and Enter. Continue with step 7 and 8.
To Configure the AirLive ePhone-1000 server account number
At the [protocol settings] prompt press enter multiple times [account] appears
Press SPD/Hold input server account number (XXX) and then press Enter
To Configure the AirLive ePhone-1000 server Account Password
At the [protocol settings] prompt press Enter multiple times[pin] appears
Press SPD/Hold Enter the Server Password and press Enter.
To Configure the AirLive ePhone-1000 Registration Port
At the [protocol settings] prompt press Enter multiple times→ [register port] appears Press SPD/Hold Enter the required PORT number for registration (XXXX) and then
press Enter.
- 17 -
Audio Settings
To Access the Audio Settings Menu
Press 1, 2, 3, 4, # (Hold the “#” key) [Password] Press 1 2 3 4 and
then press EnterNetwork Settings
Press 1, 2, 3, 4, # (Hold the “#” key) Press Vol.+ 3 times [Audio
Settings] appears.
To Configure the AirLive ePhone-1000 voice compression Codec Type:
At the [audio settings] prompt press Enter once [audio type] appears
press SPD/Hold
Press “0” and Enter to set the Codec to G.729
Press “1” and Enter to set the Codec to G .7231
Press “2” and Enter to set the Codec to G.711u
Press “3” and Enter to set the Codec to G.711a1
Press “4” and Enter to set to auto
Set the AirLive ePhone-1000 handset and speaker phone volumes
At the [audio settings] prompt press Enter 6 times→ [handset in]
appears,
Press SPD/Hold→ enter the volume level of the handset and the speaker
phone (the default setting is 7 and 15 is the highest value) and press Enter.
- 18 -
Other Settings
To Access the Other Settings Menu
Press 1, 2, 3, 4, # (Hold the “#” key) [Password] appears
Press 1, 2, 3, 4 and press Enter Network Settings appears
Press 1, 2, 3, 4, # (Hold the “#” key) →Press Vol.- multiple times→ [other
settings] appears
To Change the User Password
At the [other settings] prompt press Enter once enter the [password] Press SPD/Hold enter a new password and press Enter.
To Change the Administrator Password
At the [other settings] prompt, press Enter twice→ [super password]
appears
Press SPD/Hold
Enter the new password and press Enter.
- 19 -
Speed Dial Settings
To Access the Other Settings Menu
Press 1, 2, 3, 4, # (Hold the “#” key) [Password] appears Press 1, 2, 3, 4 and then press EnterNetwork Settings appears Press 1, 2, 3, 4, # (Hold the “#” key) Press Vol.- multiple times
Enter the [speed dial setting].
To set a Speed Dial number
At the speed dial settings prompt press Enter once→ [memory1]
appears
Press SPD/Hold to select the first speed dial number and press Enter Press Enter again[number1] appears
Press SPD/Hold
Enter the first set of telephone numbers and press Enter.
Repeat step 2 to store more numbers. The AirLive ePhone-1000 can store up
to 100 speed dial phone numbers.
- 20 -
Revert Back to Factory Default
Press 1, 2, 3, 4, # (Hold the “#” key) [Password] appears Press 1, 2, 3, 4 and press Enter Network Settings appear
Press 1, 2, 3, 4, # (Hold the “#” key) Press Vol.- multiple times
[Default Settings] appears
Press Enter→ Are You Sure? Select Yes and [Default ok] appears on the screen
Press Redial/Mute until [Undo Default Settings] is displayed [save
settings] is displayed, press Enter
The phone will reboot itself.
Select No to choose not to revert back to factory default.
- 21 -
Storing Settings
When all settings have been entered to configure the AirLive ePhone-1000
Press 1, 2, 3, 4, # (Hold the “#” key) [Password] appears
Press 1, 2, 3, 4 and press Enter Network Settings appears
Press 1, 2, 3, 4, # (Hold the “#” key) Press Vol.- multiple times [Store Settings] appears Press Enter to Store the current system settings: [Store First
Settings]
Press Enter twice [Store Second Settings]
Press Enter multiple times[Store Third Settings]
Press Enter multiple times[Store Fourth Settings]
Select the appropriate settings and press Enter to store settings.
you will want to store them.
- 22 -
Editing Settings
To change or add settings you have stored you can load and review each of
the parameters that have been set and edit them.
Press 1, 2, 3, 4, # (Hold the “#” key) [Password] appears
Press 1, 2, 3, 4 and press Enter Network Settings appears
Press 1, 2, 3, 4, # (Hold the “#” key) Press Vol.- multiple times [Load Settings] appears
To edit a specific stored setting of the current configuration
Press Enter [Load First Settings] appears
Press Enter again and the last saved setting appears. Enter a new setting and press Enter to return to the next setting. Press Enter twice [Load Second Settings] appears Press Enter again and the last saved setting appears. Enter a new setting and press Enter to return to the next setting. Press Enter multiple times→[Load Third Settings] appears Press Enter again and the last saved setting appears. Enter a new setting and press Enter to return to the next setting. Press Enter multiple times→[Load Fourth Settings] appears Press Enter again and the last saved setting appears.
Enter a new setting and press Enter to return to Main menu.
- 23 -
Saving Settings
When all configurations are complete and confirmed:
Press Redial/Mute until [save settings] appears on the screen press
Enter→ Are You Sure?
Press Enter for Yes and the AirLive ePhone-1000 will reboot and save
the new settings.
Press Redial/Mute again for No, to not save settings and return to Keypad settings.
Exit Settings
Press Redial/Mute until [Exit] appears on the screen Press Enter for Yes, the AirLive ePhone-1000 reboots.
- 24 -
WEB Configuration
As an alternate to Keypad configuration, the AirLive ePhone-1000 series VoIP
Phone can also be configured with a web browser. The AirLive
ePhone-1000 Web configuration page is accessed by entering an assigned
URL, or by pressing the “IP” button from the VoIP Phone keypad to display the
IP address.
Start a Web browser, such as Microsoft’s Internet Explorer (IE)
the AirLive ePhone-1000’s IP address on the web browser Address window.
The AirLive ePhone-1000 login screen is displayed:
, and enter
The AirLive ePhone-1000 web configuration password comes with two
categories: User password and Administrator password.
The default User Password is 1234.
The default Administrator Password is 12345678.
Enter one of the passwords and click the “Login” button.
The AirLive ePhone-1000 web based configuration page is displayed, as
shown below.
- 25 -
You can enter all the configuration parameters for the AirLive ePhone-1000
on this web page. Each of the parameters and its options are described in the
tables that follow. Enter all of the required parameters and select Save/Reboot
to complete the configuration.
- 26 -
Network Parameters
Networking Parameter Values
Fields Description
Set how AirLive ePhone-1000 gets relevant network parameters by selecting corresponding item from drop down list. static Select this option to authorize users to manually configure the IP address, subnet mask and router IP.
iptype
ppp id
ppp pin
local ip
subnet mask
router ip
dhcp Select this option to enable the DHCP server to automatically assign all the r equired network parameters to AirLive ePhone-1000. pppoe Select this option to enable a PPPoE connection. Enter the ppp id and ppp pin with a PPPoE account and Password. The ISP provider will automatically assign all the required IP para m e te r s to A AirLive ePhone-1000. With PPPoE or modem selected in the iptype drop down list, enter the user name in this field. With PPPoE or modem selected in the iptype drop down list, enter the password in this field. With Static selected in the iptype drop down list,, enter the IP address of the AirLive
ePhone-1000 in this field. With S tatic selected in iptype drop down list, enter the Subnet Mask address of the AirLive ePhone-1000 in this field. With S tatic selected in iptype drop down list, enter the router IP address of the AirLive ePhone-1000 in this field.
Dns
dns2
With S tatic selected in iptype drop down list, enter the IP address of the DNS server in this field. With S tatic selected in iptype drop down list, enter the IP addr ess of the backup DNS server in this field.
- 27 -
Protocol Parameters
Protocol Parameter Values Field Description
The AirLive ePhone-1000 supports H.323 and SIP 
protocol
use service
Select one of the phone protocols from the drop down list:
H.323: sets the phone use H.323 protocol SIP: sets the phone use SIP proto col Enable/Disable service by checking/unchecking this box. Services response to
different protocols as follows: If using SIP protocol, check this box and enter the service ad dre ss f ield with the SIP proxy Server IP address of domain name. If using H.323 protocol , the protocol service refers to the Gatekeeper searching the address. To allow AIRLIVE EPHONE-1000Ss to call each other by an E.164 number: check this option and enter the IP address or domain name of corresponding Gatekeeper into the Service Address field. To make point to point calls to another voice gateway: leave this option unchecked and enter the voice gateway’s IP address in the Service Addr. field. To make calls by dialing IP addresses of other AirLive ePhone-1000 or H.323 devices (such as Netmeeting) in the same network segment, leave this optio n unchecked and leave the Service Addr. fi eld blank. Note:
service type
In you are not using Gatekeeper, configure the service port as 1720. Refer to the Service Port configuration for more detailed informa tion. The default service type is common. For other types, select the service type from the drop down list.
- 28 -
Enter the IP address or domain name of the server according to the protocol used: H.323 protocol: If the Use Service option is checked, enter the IP address or the domain name
service addr
service id
nat traversal
address of the gatekeeper. If the Use Service option is not checked, enter the IP address or the domain name address of the voice gateway. SIP protocol: If the Use Service option is checked, ente r the IP address or domain name of the SIP Proxy Server in this field. Enter a service ID required by the system. When using a private IP to traverse the NAT, select one of the conditions from the drop down list: disable When AirLive ePhone-1000 is using public IP, please choose disable. When AirLive ePhone-1000 is using SIP protocol, and using the Outbound Proxy, please choose disable
enable
. If your AirLive ePhone-1000 is using a private IP, select enable. This automatically checks the Public IP of the NAT router and the nat address will automatically activate. Without a special request, enter the nat address 0.0.0.0 in the nat addr field and configure the port on the NAT router accordingly.
nat addr
nat ttl
phone number
account
stun STUN helps the SIP traverse the NAT and locates a public IP address and the type of NAT service for the AirLive ePhone-1000. If this option is selected, enter the IP address of the STUN server in the nat addr field. When using H.323, select Citro n if the service provider did not provide related information When nat traversal or stun is enabled, enter the IP address of the NAT Proxy. Otherwise, keep this field as 0.0.0.0. Defines the amount of time, in seconds, a NAT traversal message is sent to the NAT server. The default setting is 30 seconds. If H.323 or SIP protocol are used, enter the phone number of the AirLive ePhone-1000. If H.323 protocol is selected , enter the H323 ID or H.235 account number. If you select a prefix in the use dialplan drop-down menu, en ter the IS card number, and “#”.
- 29 -
For example 14589653185#.
If SIP protocol selected, enter the SIP Proxy account number. If H323 protocol is used to logon the gatekeeper, enter the password or H.235 authentication password.
pin
register port
signal port
control port
If SIP protocol is used to logon SIP Proxy Server, enter the password into this field. If a prefix is selected in the use dialplan drop-down menu, enter the by ISR card password number, and “#”. For example 3185#. If H.323 protocol is used, If Gatekeeper is used, the register port works as the gatekeeper’s monitor port. The default value is 1719. If the Gatekeeper is used, the register port works as the end point device or the Gatekeeper’s monitor port. The default value is 1720. If SIP protocol is used, the default setting is 5060. If H.323 protocol used, this port is m apped to the Q.931 port. Q.931 calls usually use TCP protocol. The value can be set between 1024 and 65535. If H.323 protocol is used, the control port is the H.2 4 5 por t using TCP protocol. H.245 protocol defines the c all control signal and uses TCP pr oto col. The value can be set between 1024 and 65535. If MGCP or SIP protocol is used, there is no specific request for this por t. You can enter any number. If many AirLive ePhone-1000s are active on the NAT at the same time, ea c h
register ttl
rtp tos
rtp port
local type
AirLive ePhone-1000 cannot be configured to the same port. Defines the number of seconds a register message is se nt to the server. The default setting is 60. Enter the TOS segment of the IP header used by RTP digital follow. For detailed information refer to IP pr otocol. R TP port is the port transferring and receiving voice flow using UDP protocol. Enter an even number in this field between 1024 and 65535. When H.323 protocol is used, this parameter refers to how AirLive ePhone-1000 logs in to Gatekeeper or the SIP Proxy server. Enter the following values.
Phone number Enter a phone number that corresponds to the E.164 and H.323 ID to login to the Gatekeeper.
- 30 -
Account Use account authentication to login. Enter the account name and password into the account and pin fields. H.235 account With H.323 protocol used, if the Gatekeeper supports H.235 protocol, please choose this option. Please also fill up the account name and password into the account and pin fields.
call type
dtmf
Select one of the three items in drop-down list: normal, faststart or advanced. advanced is the recommended value. The DTMF signal method of transmission. Select control string, inband audio, signal keypad or RFC 2833 from drop-down menu. If extensions cannot be dialed, set the dtmf as inband audio.
- 31 -
Phone Parameters
Phone Parameter Values Fields Description
The use dialplan parameter sets how the AirLive ePhone-1000 dials up., either by a
dial plan or by a dial number. The options below set the di a l m ethod.
disable Select disable to not use either dial plan or dial number. enable
Enables the dialing plan. The dialing plan should combine with the Regional Code
use dialplan
dial number
dddcode
iddcode
iddprefix
and Area Code. Follow the E.164 rules to setup the country code, area code and long distance code. dialnum Enables a dial number. If this option is selected, enter the dial prefix into the dial number field. RTP port: Enter an even number from 1024 to 65535 to designate the R TP port of H.323 protocol. prefix hotline Enables hotline feature. The phone will automatically dial to the destination number typed in this blank space when press Enter (Speaker Phone). If dialnum is selected, enter the dial prefix into this field. This must correspond to log in server requirements. If enable or dialnum is selected , enter an area code meeting E.164 dial rules. For example, LA 626. If enable or dialnum is selected, enter a country code meeting E.164 dial rules. For example, Taiwan 886; U.S.A .1. If enable or dialnum is selected, enter an international call prefix according to E.164 dial rules, For example 00.
- 32 -
dddprefix
If enable or dialnum is selected, enter a long distance call prefix according to E.164 dial rules. For example 00. Enable/disable multi-settings by selecting disable or enable from the dropdown list. 000 You can save a maximum of 5 settings.
innerline
local prefix
nonlocal prefix
answer
ring type
disable: disables multi-settings, the phone will call out using the current setting. enable: the designated system places calls switch: enables multi-settings. Enter the prefix switching to backup setting 1 and
backup setting2 in the local prefix and nonlocal prefix fields. If enable or switch is selected in innerline dropdown list, enter the number switching to a backup setting 1, such as 56. If enable or switch is selected in innerline dropdown list, enter the number switching to a backup setting 2, such as 57. The number of seconds before the phone switches to call aut o call forward. Enter a number from 0 to 60. To disable the auto answer function, please set this parameter to 0. Set a ring type from the drop-down menu.
dtmf 0-9: Set the ring as ordinary rings in different frequencies. not disturb: Sets the phone to no ring. pcmring: Sets the ring to music. user define: Sets to music saved by user
use digitmap
Enables/Disables digitmap.
forward number Enter a phone number to forward calls to in this field.
Check this box to forward all calls if the power is off. Enter the forwarding phone
fwd poweroff
number in the forward number field. Check this box to forward all calls without replying. Enter the forwarding phone
fwd noanswer
number in the forward number field. Check this box to forward all calls. Enter the forwarding phone number in the
fwd always
forward number field.. Check this box to forward all calls if busy. Enter the forwarding phone number in the
fwd busy
forward number field.
- 33 -
Audio Parameter Values Fields Description
Select the audio type of the phone by selecting an option from the drop down list.
audio type
audio frames
g.723 high rate
vad
agc
aec
handset in
The options are g.71 1u, g.711a, g.723.1, g.729, g.729a, g.729b and auto.
Sets the audio frames in the RTP package. If the G723 audio codec used, set it as 1; If the G729 audio code is used, set it as 2.
If g.723.1 selected in audio type, enable/disable g.723. 1 hi g h rate (6.3K) by checking / unchecking this option.
Enable/disable VAD (voice activity detection) by checking / unchecking this box.
Enable/disable AGC by checking/unchecking this box.
Enable/disable VEC by checking/unchecking this bo x.
Drag the slider to adjust the volume of handset input. Drag it to the left to reduce the volume; drag it to the right to increase the volume. The range is 1 to 15. Drag the slider to adjust the volume of handset output. Drag it to the left to reduce
handset out
the volume; drag it to the right to increase the volume. The range is 1 to 26.
- 34 -
Audio Parameters
Sets the audio frames in the R TP package. If the G723 audio codec used, set it as
audio frames
g.723 high rate
vad
agc
aec
handset in
handset out
1; If the G729 audio code is used, set it as 2.
If g.723.1 selected in audio type, enable/disable g.723.1 hi g h rate (6.3K) by checking / unchecking this option.
Enable/disable VAD (voice activity detection) by checking / unchecking this box.
Enable/disable AGC by checking/unchecking this box.
Enable/disable VEC by checking/unchecking this box.
Drag the slider to adjust the volume of handset input. Drag it to the left to reduce the volume; drag it to the right to increase the volume. The range is 1 to
15. Drag the slider to adjust the volume of handset output. Drag it to the left to reduce the volume; drag it to the right to increase the volume. The range is 1 to
26.
- 35 -
Other Parameters
Other Parameter Values Field Description
Password
Super password Set the administrator’s password. Maximum 16 digits long
debug
sntp ip
use daylight
upgrade addr
Sets the user’s password. Maximum 16 digits long.
Sets the debug level of the phone.
Disable: Disables bug messages Output: Sends operation information, such as register input. to the phone
window,
Output all: Sends all bug information and data to a test window Remote debug: Saves bug information in SDRAM of AirLive ePhone-1000. No check: Disables checks.
IP address of the time server here.
Enables/Disables daylight sa vings time by checking /unchecking this option.
Enter the IP addre ss or domain name for the IPS of the FTP server that sends updated program informatio n he re.
- 36 -
Save/Reboot Parameters
After you enter all the configuration values, press Save/Reboot. AirLive
ePhone-1000 will save the settings and reboot. If the webpage returns to the
login page, login and configure again. Phone Book
Click on Phone Book to access the AirLive ePhone-1000 phone book page.
You may create a phone book entry by input the necessary information in their
corresponding spaces. Click on Save/Back to save your entries. The Speed
dial function will then be activated after you have saved an entry.
- 37 -
When operating H.323 Protocol, you may enter the IP address instead of a
phone number to create an entry when there is no gatekeeper or a voice
gateway. Please use “*” instead of “.” when inputting an IP address. For
example 192.168.1.21 should be entered as 192*168*1*21.
Nat Traversal Function
AirLive ePhone-1000 Supports Nat Traversal Functions STUN
server addressEnter SIP Server IP address or Domain nat traver salSelect STUN nat addrEnter STUN server IP address or Domain
OutBound Proxy
server address Enter outbound proxy IP or Domain. Fill-in the port number is the UDP port is not 5060. service idEnter SIP proxy IP or Domain nat traver salSelect disable
Registration Message
When the registration for AirLive ePhone-1000 is successful, Ready for Call
will appear on the screen. If the registration is not successful hand Log fail or
Wait Log will appear.
- 38 -
Using AirLive ePhone-1000
To make a phone call
When dialing a call with the AirLive ePhone-1000, press “#” after the phone
Review call record
Press the “Miss” button to review any missed calls. Press “#” to return a
missed call. Press Vol.+ to view the next entry and Press Vol.- to view the
number.
previous entry.
Speed Dial
Press the “Ans” button on to review any received calls. Press “#” to return a
received call. Press Vol.+ to view the next entry and Press Vol.- to view the
previous entry.
Press the “Called” button on to review any dialed calls. Press “#” to redial a
dialed call. Press Vol. + to view the next entry and Press Vol.- to view the
previous entry.
AirLive ePhone-1000 can store a total of 80 Missed, Received and Dialed call
entries. When entries exceed its number, the AirLive ePhone-1000 deletes
the oldest entry automatically. Records will be lost during power outage and
reboot.
The Speed Dial feature can only used when entries are stored in the Speed
Dial Settings or in the phone book on web configuration.
Operating Instructions
Press the entry number and press SPD/Hold to use the speed dial function.
- 39 -
Mute
Hold
Press the “Redial/Mute” button during a conversation to mute the microphone.
Press “SPD/Hold” button during a conversation to hold a call.
- 40 -
Appendix
This table illustrates the conversion of numbers and symbols with the Keypad Keys
Number key Press once Press twice Press 3 times Press 4 times Press 5 times 1 2 3 4 5 6 7 8 9 * # Switch to upper/lower case
/          
A/a B/b C/c D/d E/e F/ f G/g H/h I/i J/j K/k L/l M/m N/n O/o P/p Q/q R/r S/s T/t U/u V/v W/w X/x Y/y Z/z
Space
  
@  
H.323 sample web setting When the AirLive ePhone-1000 is operating using H.323 protoc ol, please change the below parameters. Other settings remain the same.
- 41 -
Contact your service provider for detail information
use servicePlease check the box service typeSelect common unless specified. service addr nat tracersaSelect citron unless specified phone numberEnter the phone number provided by the service provider accountEnter your account number provided by the service providerH.323 ID pinEnter pin number pr ov ided by the service provider Register port 1719 unless specified. Signal port1720 unless specified Control port1722 unless specified Rtp port1722 unless specified Local type account is the usual selection. Please select based upon the parameter provided by your service provider
- 42 -
Frequently Asked Questions
Question Solution
LCD Error
LCD shows Wait Logon or Logon Failed
LCD shows Ready for Call, but unable to dial Loud echo during conversation Static Check all cables to see if they are connected properly.
Revert to factory default setting
Unplug the power supply, wait 5 seconds and then plug the power supply back. Check if the RJ-45 cable is connected properly and also confirm to see if the AirLive ePhone-1000 has successfully obtained an IP address. If an IP address is not obtained check to see if there are errors for network and account settings. Contact your service provider to check account setting. Call your service provider to check account settings.
Press Vol.- to decrease handse t vo lume until there is no echo.
1. Press “1234*”.When “Booting….” Appear on the LED,release the “*” button.
2. When “Page0 running” appears on the LED, release the “*” button and then press “#5*5”. The AirLive ePhone-1000 reboots.
- 43 -
The AirLive ePhone-1000 Phone Tree T ype Menu administration
- 44 -
- 45 -
- 46 -
Loading...