Installation Manual
JSS-1A (A set includes JS-1MD, JS-DA, and power supply)
JS-1HD (Sub monitor station)
Issue date: Oct. 2019 FK2685 A P1019 AQ 61458
Parts names
JS-1MD / JS-1HD
The illustration is JS-1MD.
Door release button
Audio transmit
LED (orange)
Power switch
Talk/Off button
Color LCD screen
Remove protective lm before use, if attached.
Microphone
Monitor button
Screen brightness
control button
Volume control
button
Speaker
JS-DA
Camera-angle
adjustment lever
The camera-angle adjustment lever is
on the back of the door station.
[Back side]
Camera-angle
adjustment lever
Call button
White light LED
Cable inlet holes
Camera
Microphone
Mounting frame
Front panel
Speaker
Location LED (red)
Drainage holes
Included accessories
Installation
manual x1
(this manual)
Information
sheet x1
Mounting bracket x1
(attached to the monitor
station)
NOTES:
Mounting and wood mounting screws not included.
•
For details on the power supply, see the installation manual of the power supply separately.
•
Front panel x1
(attached to the door
station, JSS-1A only)
Caution (Negligence could result in injury to people or damage to property.)
1. Do not install or connect the station with the power on. This may result in electrical shock
or malfunction.
2. Make sure the wiring is correct and there are no wiring shorts before switching on the
station. This may result in re or electrical shock.
3. Install in a place where the station will not get easily bumped. This may result in injury.
4. Do not put your ear close to the speaker when using the station. May cause harm to the
ear if a sudden loud noise is emitted.
Precautions for mounting
1. The monitor station is designed for indoor use only. Do not install at outdoor location.
2. Installing the device in the following locations could cause malfunction:
* Locations under direct sunlight (except door station)
* Locations near heating equipment
* Locations subject to liquid, iron lings, dust, oil, or chemicals
* Locations subject to moisture and humidity extremes
* Locations where the temperature is quite low
* Locations subject to steam or oil smoke
* Sulphurous environments
* Locations close to the sea or directly exposed to sea breeze
3. Installing the station in the following locations as is may affect the clarity of the image:
* Where lights will shine directly into the camera at night time
* Where the sky lls much of the background
* Where the background of the subject is white
* Where sunlight or other strong light sources will shine directly into the camera
Where the sky fills much of
the background
Sky
4. In 50Hz regions, if a strong uorescent light enters directly into the camera, it may cause the
image to icker. Either shield the camera from the light or use an inverter uorescent light.
5. Use a parallel 2 conductor cable to connect the door station.
6. For wiring, separate them for audio/video and door release and keep them more than 10cm
(3-15/16”) away from each other.
7. If exisiting wiring is used, the device may not operate properly. In that case, it will be
necessary to replace the wiring.
8. Do not use any impact driver to fasten screws. Doing so may cause damage to the device.
9. Do not install the product on a recessed wall to avoid interruption of communication.
10. Using a single multi-conductor cable for multiple connections may result in poor image quality.
Where the background of
the subject is white
White
wall
Where sunlight or other
strong light sources will shine
directly into the camera
Wiring method, wiring distance
JS-DA
JS-1MD
JS-1HD
B B
: PS-2420, PS-2420S, PS-2420UL,
PS24
Ø 0.65 mm 22 AWG Ø 0.8-1.2 mm 20-16 AWG
A 50 m 165′ 100 m 330′
B 5 m 16′ 10 m 33′
Installation
Cable
Use PE (polyethylene)-insulated PVC jacket
•
cable.
Parallel or jacketed 2-conductor,
mid-capacitance non-shielded cable is
recommended.
Never use individual conductors, twisted pair cable or coaxial cable.
•
To connect low voltage wires, either crimp them with a crimp sleeve or solder
them, and then insulate by covering with insulating tape.
[Crimping with a crimp sleeve]
1. Line up solid and
stranded conductors,
and crimp them.
Solid conductor
Stranded conductor
[Soldering]
1. Twist the stranded
conductor around the
solid conductor at least
three times.
Solid
conductor
Stranded
conductor
Crimp sleeve
2. Bend the tip and solder it.
Make sure no lead wire
sticks out.
2. Overlap more than half
Soldering
of the width and twist
them at least twice.
Insulating tape
3. Overlap more than half of
the width and twist them at
least twice.
Insulating tape
Precautions
Prohibited
Do not dismantle unit
Be sure to follow
the instruction
Warning (Negligence could result in death or serious injury.)
1. Do not disassemble or modify the station. This may result in re or electrical shock.
2.
Do not use with a power supply rated above the specied voltage. This may result in re or
electrical shock.
3. Do not install two power supplies in parallel to a single input. This may result in re or
electrical shock.
4. Do not connect any terminals on the station directly to an AC power line. This may result in
re or electrical shock.
5.
Use the Aiphone power supply specic for use with the system. This may result in re or
malfunction.
General Precautions
1. Install low-voltage lines at least 30 cm (12”) away from high-voltage lines (AC100V-240V),
especially inverter air conditioner wiring. This may result in interference or malfunction.
2. When installing or using the station, give consideration to the privacy rights of subjects, as it
is the responsibility of the system owner to post signs or warnings in accordance with local
ordinances.
Notice
1. If the station is used in areas where there are business-use wireless devices such as a
transceiver or mobile phones, it may cause malfunction.
2. If the station is installed near a wireless device, interference may occur and could cause a
malfunction.
3. If the station is installed in an area with an extremely strong electrical eld, such as in the
vicinity of a broadcasting station, it may create interference and cause a malfunction.
4. Internal and external temperature difference may cause condensation on the camera.
Plugging cable holes and other gaps is recommended for preventing condensation.
• When using existing cables
Check for short circuit and disconnection before installation.
Ø0.8-1.2mm, 100m (20-16 AWG, 330’)
Loop resistance value: 6Ω or less
Disconnection check (6Ω or less)
Connect the ends of one side and make a measure at the other side with a tester.
Connect the ends of
one side.
Short circuit check: ∞Ω (Innity)
Disconnect
Measure the resistance of this loop.
Installation
Mounting
Installation location of the video door station and image view area
JS-DA
The angle of the camera lens can be adjusted in the range of 15° in the upward,
right, and left directions and in the range of 7° in the downward direction.
The camera angle adjustment lever is at the back of the station.
Downward direction (up to 7°)
Angle adjustment lever
Right direction (up to 15°)
Upward direction (up to 15°)
Adjustment examples
To the center
(default)
The angle can also be adjusted to the right and right upward.
•
The image may be distorted when the angle is set to left upward or right upward.
•
Upward Downward To the left Left upward
• View area at 500 mm (20”) in front of the camera
Approx. 950 mm (3’1”)
Approx.
550 mm
(22”)
Vertical
Camera angle: 0° Camera angle: 15° Camera angle: −7°
Approx. 1,800 mm (5’11”)
Approx.
550 mm (22”)
Approx.
1,250 mm
(4’1”)
500
mm
(20”)
Station
center
1,500 mm
(5’)
Approx. 1,850 mm (6’1”)
Approx.
650 mm (2’2”)
Approx.
1,200 mm
(3’11”)
Left direction (up to 15°)
Station
center
500
mm
(20”)
1,300 mm
(4’3”)
( When the station is installed to
a high position due to a step)
Approx. 1,900 mm (6’3”)
Approx.
600 mm (2’)
Approx.
1,300 mm
(4’3”)
500
mm
(20”)
150 mm
(6”)
Station
center
1,500 mm
(5’)
JS-1MD / JS-1HD
The illustration is JS-1MD.
<Back wiring> <Surface wiring>
Remove the mounting
2
bracket.
(The mounting bracket is
attached to the back of the
station.)
Slide the mounting bracket
downward to remove it.
Release button
Station
Mount the station on
5
the mounting bracket.
Connect wires.
4
1. Press the release button (to insert
or remove the wire).
2. Insert the wire into the terminal.
Release button
Mounting bracket
Slide downward
Wood mounting screw × 2
(not included)
Screw shaft: Ø 4.1 or less
Slotted head: Ø 8.2 or less,
3.0 mm or less in height
Mounting bracket
(attached to the station)
1
9 mm (3/8”)
Center of the
monitor station
17 mm (11/16”)
Center of
the mounting
bracket
Fasten the
3
mounting
bracket to
the wall.
Place “ UP”
upwards
83.5 mm (3-5/16”)
Wires
Mounting height
(center of the
mounting bracket)
1,480 mm (4’ 10’’)
Cut a small round hole
(Ø 50 mm (1-15/16″)) in the wall
for routing wires.
* Cut a hole at a position shifted 17 mm
(11/16”) to the down from the station
center.
Center of the monitor station
83.5 mm
(3-5/16”)
Mounting bracket
The wires can be routed to the top or bottom of the station.
Cut the cable inlet to allow passage of the wiring into the station from the top or bottom
of the station.
If there is a large amount of wiring, strip away the jacket of the wire up to the cable inlet.
Cut the cable inlet at the top or
bottom of the station.
(The gure shows the station with
the bottom inlet removed.)
Station
Wires
When the wood mounting screws cannot be
used for plasterboard walls, concrete walls
and so on, use commercially-available board
anchors or concrete plugs.
(e.g.)
Board anchor Concrete plug
Make sure to leave at least the specied spaces on all sides to prevent malfunction and
•
audio distortion.
Molding
Wood mounting screw × 2
(not included)
Screw shaft: Ø 4.1 or less
Slotted head: Ø 8.2 or less,
3.0 mm or less in height
Use cable moldings for the power wire and the
other wires. The open wire sections between
the station and the cable moldings should be
80mm (3-1/8”) or less.
Molding
Be sure to pass the wood
mounting screws through
the holes at the center.
The station cannot be installed
if the wood mounting screws
are inserted into other holes.
Place “ UP”
upwards
83.5 mm (3-5/16”)
Mounting height
(center of the
mounting bracket)
1,480 mm (4’ 10’’)
Mounting bracket
(attached to the station)
80 mm (3-1/8”)
or less
200 mm (7-7/8”)
Horizontal
Camera angle: 15°
<To the left when facing the camera>
500 mm (20”)
Approx. 750 mm (2’5”)
Approx. 1,000 mm (3’3”)
Approx.
250 mm
(9-13/16”)
Camera angle: 0° Camera angle: 15°
<To the right when facing the camera>
500 mm (20”)
Approx. 950 mm (3’1”)
Approx.
250 mm
(9-13/16”)
Approx. 1,000 mm (3’3”)
Approx. 750 mm (2’5”)
200 mm (7-7/8”)
200 mm (7-7/8”)