Aiphone JPW-BA, JP-8Z User Manual

JP-4MED
HANDS-FREE COLOR VIDEO INTERCOM MASTER STATION
JPW-BA
LONG DISTANCE ADAPTOR
JP-8Z
INSTALLATION MANUAL
JPW-BA
JP-4MED
JP-8Z
Thank you for selecting Aiphone for your communication and security needs. Please read this manual carefully before installation, and keep it in a safe place for future reference. Also read the installation manuals for the other devices included in your system.
Please note that the illustrations in this manual may differ from the actual product.
CONTENTS
PRECAUTIONS ................................ 3
WARNING ........................................... 3
CAUTION ............................................ 3
GENERAL PRECAUTIONS ............... 3
NOTICES ............................................ 3
PACKAGE CONTENTS ................... 4
CONNECTIONS ............................... 4
Notes about handling cables .......... 4
Wiring distance ................................ 5
Selecting power supply method ..... 6
Basic system connection ................ 8
Expanding the system ................... 10
Connecting external devices
(using the option connectors) ...... 12
MOUNTING ................................... 13
Mounting locations ......................... 13
Mounting procedure ....................... 14
SETTINGS AFTER
INSTALLATION ............................. 16
Setting list ........................................ 16
[INSTALL] menu .............................. 16
Setting for inputs and outputs ....... 17
Door release settings
[SET DOOR RELEASE] ................... 18
Initializing station [INITIALIZE] ..... 19
Identifying software version
[SOFTWARE VERSION] ................. 19
TECHNICAL DATA AND
PRECAUTIONS .............................. 19
WARRANTY .................... Back cover
Term defi nition
This manual uses "residential station" as the common term for "master station" and "sub master station".
2
PRECAUTIONS
Prohibited Do not dismantle unit Keep unit away from water
General precautions
WARNING
Negligence could result in death or serious injury.
1. Do not dismantle or alter the unit. Fire or electric shock could result.
2. Keep the unit away from water or any other liquid. Fire or electric shock could result.
3. High voltage is present internally. Do not open the case. Electric shock could result.
4. Do not connect any non-specifi ed power source to the +, - terminals. Also, do not install two power supplies in parallel to a single input. Fire or damage to the unit could result.
5. Do not connect any terminal on the unit to an AC power line. Fire or electric shock could result.
6. Do not use power supply with a voltage other than specifi ed. Fire or electric shock could result.
7. Keep AC cord from being marred or crushed. If the AC cord is damaged, fi re or electric shock could result.
8.
Do not plug or unplug unit with wet hands. Electric shock could result.
9. Insert AC plug completely and securely into AC outlet. Otherwise, fi re or electric shock could result.
10.
Periodically check for and remove dust on the power plug. If dust is left, it could cause the power plug to heat up, resulting in re.
11.
Do not put any metal or fl ammable material into the unit through the openings. Fire, electric shock, or unit trouble could result.
CAUTION
Negligence could result in injury or damage to property.
1.
Do not install or make any wire terminations while power supply is plugged in. It can cause electrical shock or damage to the unit.
2. When mounting the unit on a wall, install the unit in a convenient location, but not where it could be jarred or bumped. Injury could result.
3. Before turning on power, make sure wires are not crossed or shorted. Fire or electric shock could result.
4.
Do not install the unit in locations subject to frequent vibration or impact. It may fall or tip over, resulting in damage to the unit or personal injury.
5. For power supply, use Aiphone power supply model specifi ed for use with system. If non-specifi ed product is used, fi re or malfunction could result.
6. Do not apply high pressure on the screen. If fractured, injury could result.
7. If LCD is punctured, do not touch the liquid crystal inside. Infl ammation could result. If contact should occur, fl ush or rinse area with water thoroughly and consult your doctor.
8. Do not put anything on the unit or cover the unit with cloth, etc. Fire or unit trouble could result.
9. Do not install the unit in any of the following locations. Fire, electric shock, or unit trouble could result.
Places under direct sunlight or near heating equipment that * varies in temperature.
Places subject to dust, oil, chemicals, hydrogen sulfi de (hot * spring).
Places subject to moisture and humidity extremes, such as * bathrooms, cellars, greenhouses, etc.
Places where the temperature is quite low, such as inside a * refrigerated area or in front of an air conditioner.
Places subject to steam or smoke (near heating or cooking * surfaces).
Where noise generating devices such as dimmer switches or * inverter electrical appliances are closeby.
10. Be sure to perform a call test or check the volume with the handset on the hook. If you operate the hook switch with the handset on your ear, a sudden call etc. may arrive causing damage to your ear.
11. The unit must be installed and wired by a qualifi ed technician.
GENERAL PRECAUTIONS
1. Keep the unit more than 1 m (3.3') away from radio or TV sets.
2. Keep the intercom wires more than 30cm (12'') away from AC 100-240V wiring. AC induced noise and/or unit malfunction could result.
3. Comply with all third party manufacturing specifi cations that will be used with this system (sensors, door releases, etc.).
4. If it is used close to a cellular phone, the unit may malfunction.
5. The unit can be damaged if dropped. Handle with care.
6. The unit will not work during power failure.
7. In areas where broadcasting station antennas are close by, the intercom system may be affected by radio frequency interference.
8. All the units, except for door stations, are designed for indoor use only. Do not use at outdoor locations.
9. This product, providing door release, should not be used as a crime prevention device.
10. Please note the LCD panel, though manufactured with very high precision techniques, inevitably will have a very small portion of its image elements always lit or not lit at all. This is not considered a unit malfunction.
11. Environmental sound around the unit may hinder smooth communication, but this is not a malfunction.
12. The unit has audio monitoring function between residential stations. When using this function for baby monitoring, never install the unit within reach of children to prevent strangulation with coil cord or wires.
NOTICES
We will under no conditions be liable for damage occurring due
to the inability to communicate due to malfunctions, problems, or operational errors in this product.
We will under no conditions be liable for any damages or losses
resulting from this product's contents or specifi cations. This manual was created by Aiphone Co., Ltd., all rights reserved.
Copying, in part or in whole, this manual without prior permission from Aiphone Co., Ltd. is strictly forbidden.
Please note that images and illustrations depicted in this manual
may differ from the actual ones. Please note that this manual may be revised or changed without
prior notice. Please note that product specifi cations may be changed for the sake
of improvement without prior notice. This system is not intended for life support or crime prevention. It is
a supplementary means of conveying information. Aiphone will under no conditions be liable for loss of life or property which occurs while the system is being operated.
3
PACKAGE CONTENTS
Verify that the following parts are included.
JP-4MED
The unit 12-pin option connector 4-pin option connector Installation Manual/Operation Manual
JPW-BA JP-8Z
The unit The unit
CONNECTIONS
Notes about handling cables
*
Cables and connectors are not included with the products.
Notes on cables (for door stations, etc.)
Use PE (polyethylene)-insulated PVC jacket cable.
Parallel or jacketed 2-conductor, mid-capacitance, non-shielded cable is recommended.
Never use individual conductors, twisted pair cable, or coaxial cable.
Notes on CAT5e cables (for residential stations)
Do not bend the cables to an extent where the radius is
less than 25 mm (1”). Communication failure could result.
CAT5e cable
25mm (1") or more
CAT5e cable
Less than 25mm (1")
Do not remove the CAT5e cable jacket more than
necessary.
This unit is not a computer peripheral. Do not connect it
to a LAN network.
Arrange the color code of the RJ45 connections in accordance
with EIA/TIA-568A or 568B.
Pair2
Pair3
Pair1
T568B
Pair4
Pair2
Pair4
Pair1
Pair3
12345678 12345678
T568A
Be sure to check the condition of cable connections with a
LAN checker before connecting with a LAN cable.
An RJ45 connector with a cover cannot be connected to the port
for CAT5e. Use a cable without a cover.
Do not pull or put excess strain on CAT5e cables.
Use a straight-through cable for connecting units.
4
Wiring distance
*
The wiring distance between the power supply and each unit differs depending on the power supply method. (
[H]
[I]
[F]
Station-to-station (daisy-chained) wiring
[J]
[A]
Refer to "Selecting power supply method". (P. 6)
or
Jb
PS24
[B]
[C]
or
[D]
PS24
[E]
Home-run wiring
P. 6)
[D]
[C]
PS24
[E]
Ja
PS24PS24
Jc
[G]
[J] = Ja + Jb + Jc + --- + Jh
Jh
[B]
Refer to "Selecting power supply method". (P. 6)
:
Master station
:
Sub master station
::
CAT5e (non-shielded) Power supply
PS24
Wiring distance between each device
Coaxial
Door station - master station - - 50 m (165') 100 m (330') 100 m (330') 100 m (330')
[A]
Door station - long distance adaptor - - 100 m (330') 150 m (490') 200 m (650') 200 m (650')
[B]
Long distance adaptor - master station - - 50 m (165') 75 m (245') 100 m (330') 100 m (330')
[C]
Master station - power supply - - 5 m (16') 5 m (16') 10 m (33') 10 m (33')
[D]
Long distance adaptor - power supply - - 50 m (165') 75 m (245') 100 m (330') 100 m (330')
[E]
Master station - external display 3 m (10') - -
[F]
Long distance adaptor - CCTV camera 15 m (50') - -
[G]
Master station - multiple door release adaptor - - 50 m (165') 75 m (245') 100 m (330') 100 m (330')
[H]
Master station - optional call extension speaker - - 75 m (245') 100 m (330') 150 m (490') 150 m (490')
[I]
Total wiring distance of residential stations - 300 m (980') -
[J]
CAT5e
(24AWG)
Ø0.65 mm
(22 AWG)
Wire diameter
Ø0.8 mm
(20 AWG)
Ø1.0 mm
(18 AWG)
Ø1.2 mm
(16 AWG)
5
Selecting power supply method
The system allows you to select from the following methods for supplying power to the system. The maximum wiring distance differs depending on the power supply method. You can also mix-and-match the methods 1 to 4.
1
Supplying power directly to each unit from a single power supply
CAUTION
Be sure to distribute the output of the power supply close to the power supply.
[B]
[A]
DP
PS24 PS24
The following chart indicates how many units can be powered by a single power supply.
Combination of units Master station Sub master station Long distance adaptor Master and sub master stations 1 4 ­Master and sub master stations with long distance adaptors 1 3 4 Sub master stations only - 6 -
2
Supplying power to sub master stations via wiring with the master station
:
Master station Sub master station
DP
DP
:
:
[D][C]
Distribution point
[B]
[E] [F] [G]
[A] [H] [H]
PS24 PS24PS24
The following chart indicates how many units can be powered by a single power supply.
Combination of units Master station Sub master station Long distance adaptor Master and sub master stations 1 2 ­Master and sub master stations with long distance adaptors 1 2 4 Sub master stations only - 3 -
3
Connecting a power supply to the master and each sub master station individually
[B]
[I] [I]
[A] [J]
PS24 PS24PS24PS24 PS24 PS24 PS24 PS24
6
Loading...
+ 14 hidden pages