Seed Tube Monitor Module
To create a conguration, make the following button presses to start the Conguration Wizard and then follow
the instructions given on the display.
Enter Settings
Conguration Product
Planting
Press to Highlight Conguration
8360,1770,3dr
Planting
Select the
number of
interplant
rows
Select device which will be used to supply ground speed
See Below
Start of Conguration Wizard
Select the number of
standard rows (does
not include interplant
rows)
See Next Page
Congure High and Low population alarms.
Each row can be set independently
Used to manually edit the sensor # that is designated to
a row #
Enable/Disable a sensor
Automatically appoints sensor #1 as row #1, and so on.
(This must be performed for the new conguration to
become active)
Removes individual seed tube sensors
Sets Row Spacing
Quick Reference Guide
2006005-ENG Rev A
1
Seed Tube Monitor Module
To start the Field Operation Wizard and load a conguration:
Conguration
Start Field Operation
Drop down menu (crop type)
Select crop type to be planted (this option
is only used to crops compatible with
Advanced Seed Tube Monitoring)
This value determines how close 2 seeds
must be planted to one another for it to
be determined as a double
This value determines how close 2 seeds
must be planted to one another for it to
be determined as a poorly spaced seed.
To view run screen:
Congure High and Low population arms. Each row can be set independently
Adjusts the displayed planted population
by this factor. Value should be 1 for corn.
Increase for higher population crops, for which
the seed tube sensor may be unable to count
each seed individually
Advanced Seed Monitoring (only available for compatible crop types)
Adjusts the Double Seed Threshold and Poor
Spacing Threshold
Display will alarm when singulation is below
this value: Singulation = % skips + % doubles
Display will alarm when spacing quality is
below this value
Disables alarms that would otherwise occur when planter clutches are commanded to a no-
plant state. This option should typically be enabled
Opens module diagnostics screen
Displays seeds/second and seeds/acre for each seed tube sensor
Quick Reference Guide
2006005-ENG Rev A