Ag Leader EZ-Guide 250 Installation

2202 South Riverside Drive, P.O. Box 2348, Ames, IA 50010
Phone: 515-232-5363 Fax: 232-3595 Internet: http://www.agleader.com
Installation Instructions: NMEA Output Cable – EZ-Guide 250
2. Hold connector with rear grommet facing you.
3. Remove the plastic inserts from cavity’s 5, 6, and 7
4. Insert the Yellow wire of cable p/n 4001444 (TNL p/n 63076) into cavity 5.
5. Insert the Violet wire of cable p/n 4001444 (TNL p/n 63076) into cavity 6.
6. Insert the Green wire of cable p/n 4001444 (TNL p/n 63076) into cavity 7.
Part No. 2005927 Rev A
1
2202 South Riverside Drive, P.O. Box 2348, Ames, IA 50010
Phone: 515-232-5363 Fax: 232-3595 Internet: http://www.agleader.com
7. Push contact straight into connector grommet until a click is felt. A slight tug will confirm that contact is properly locked in place.
8. Once all contacts are in place, reinsert the orange wedgelock. The wedgelock will snap into place.
9. If more length is needed, p/n: 4001541-6 can be used. A null modem cable (p/n: 2000819) is required for connection to an Ag Leader monitor.
Part No. 2005927 Rev A
2
Loading...
+ 1 hidden pages