Agilent Technologies N1022A User Manual

Agilent N1022A Active Probe Adapter User Guide

Notices
© Agilent Technologies, Inc. 2003
No part of this manual may be repro­duced in any form or by any means (including electronic storage and retrieval or translation into a foreign lan­guage) without prior agreement and writ­ten consent from Agilent Technologies, Inc. as governed by United States and international copyright lays.
Manual Part Number
N1022-90001
Edition
First edition, April 2003
Printed in USA
Agilent Technologies, Inc. Lightwave Division 1400 Fountaingrove Parkway Santa Rosa, CA 95403, USA
Warranty
The material contained in this document is provided “as is,” and is subject to being changed, without notice, in future edi­tions. Further, to the maximum extent permitted by applicable law, Agilent dis­claims all warranties, either express or implied, with regard to this manual and any information contained herein, includ­ing but not limited to the implied warran­ties of merchantability and fitness for a particular purpose. Agilent shall not be liable for errors or for incidental or conse­quential damages in connection with the furnishing, use, or performance of this document or of any information con­tained herein. Should Agilent and the user have a separate written agreement with warranty terms covering the mate­rial in this document that conflict with these terms, the warranty terms in the separate agreement shall control.
Technology Licenses
The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license.
Safety Notices
CAUTION
Caution denotes a hazard. It calls attention to a procedure which, if not correctly per­formed or adhered to, could result in damage to or destruction of the product. Do not proceed beyond a caution sign until the indicated conditions are fully understood and met.
WARNING
Warning denotes a hazard. It calls attention to a procedure which, if not correctly per­formed or adhered to, could result in injury or loss of life. Do not proceed beyond a warning sign until the indicated conditions are fully understood and met.
Restricted Rights Legend
If software is for use in the performance of a U.S. Government prime contract or subcontract, Software is delivered and licensed as “Commercial computer soft­ware” as defined in DFAR 252.227-7014 (June 1995), or as a “commercial item” as defined in FAR 2.101(a) or as “Restricted computer software” as defined in FAR
52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Agilent Technologies’ standard commercial license terms, and non-DOD Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR
52.227-19(c)(1-2) (June 1987). U.S. Gov­ernment users will receive no greater than Limited Rights as defined in FAR
52.227-14 (June 1987) or DFAR 252.227­7015 (b)(2) (November 1995), as appli­cable in any technical data.
ii

Contents

N1022A Active Probe Adapter 1
General Safety Considerations 2 Instrument Markings 3
Using the Probe Adapter 4
Inspecting the N1022A 4 Connecting the N1022A 5
Static-Safe Workstation 8
Reducing ESD Damage 9
Specifications and Regulatory Information 10
Specifications 10 Regulatory Information 13 Declaration of Conformity 14
Service 15
Checking Probe Power Outputs 15 Returning the N1022A 16 Agilent Technologies Service Offices 17
Contents 1
Contents
Contents 2

N1022A Active Probe Adapter

N1022A Active Probe Adapter
The N1022A Active Probe Adapter provides the interface to connect an Agilent Infiniimax Active Probe to an Agilent 86100-series Infiniium DCA. To use the N1022A requires that firmware revision A.03.05 or later be installed on the Infiniium DCA.
The Infiniimax Active Probes include the following: 1131A, 1132A, and 1134A.
Other supported active probes include the 1152A, 1156A, 1157A, and 1158A.
CAUTION When using the N1022A, always work at a static-safe work station and wear a
wrist-strap or heel-strap. Refer to “Static-Safe Workstation” on page 8.
CAUTION The probe adapter connections can be damaged if it is dropped from excessive
heights onto a hard surface.
1

General Safety Considerations

General Safety Considerations
This product has been designed and tested in accordance with the standards listed in the Manufacturer’s Declaration of Conformity, and has been supplied in a safe condition. The product documentation contains information and warnings which must be followed by the user to ensure safe operation and to maintain the product in a safe condition.
Before using this product, review the safety information for cautions and warnings.
Use this product according to the enclosure protection provided. This product does not protect against the ingress of water. This product protects against finger access to hazardous parts within the enclosure.
WARNING If this product is not used as specified, the protection provided by the
equipment could be impaired. This product must be used in a normal condition (in which all means for protection are intact) only.
WARNING No operator serviceable parts inside. Refer servicing to qualified
personnel. To prevent electrical shock, do not remove covers.
WARNING To prevent electrical shock, disconnect the Agilent N1022A from
probe power before cleaning. Use a dry cloth to clean the external case parts. Do not attempt to clean internally.
CAUTION Do not use too much liquid in cleaning the product. Water can enter the
adapter, damaging sensitive electronic components.
CAUTION This product is designed for use in INSTALLATION CATEGORY II and
POLLUTION DEGREE 2, per IEC 61010-1 and 664 respectively.
Installation Category: Installation Categories (overvoltage categories) are determined by the transient overvoltage levels that may be expected. CAT I: Mains isolated. CAT II: Line voltage in appliance and to wall outlet. CAT III: Line voltage behind wall outlet to next level of distribution.
2

Instrument Markings

The instruction manual symbol. The product is marked with this warning symbol when it is necessary for the user to refer to the instructions in the manual.
The laser radiation symbol. This warning symbol is marked on prod­ucts which have a laser output.
The AC symbol is used to indicate the required nature of the line module input power.
The Standby symbol is used to mark the position of the instrument power line switch.
The CE mark is a registered trademark of the European Commu­nity.
The CSA mark is a registered trademark of the Canadian Standards Association.
The C-Tick mark is a registered trademark of the Australian Spec­trum Management Agency.
ISM1-A
ICES/NMB-001
This text denotes the instrument is an Industrial Scientific and Medical Group 1 Class A product.
This text indicates product compliance with the Canadian Interference-Causing Equipment Standard.
Instrument Markings
3

Using the Probe Adapter

Using the Probe Adapter
There are a few things to consider when connecting the N1022A Active Probe Adapter to an active probe and the Infiniium DCA.
• The dynamic range of the system will be 3.2 V (6.4 Vp-p), which with probe off­set, covers most digital technologies.
• The Infiniium DCA provides both power and offset control to the active probe adapter through the plug-in module front panel connector.
• Probe offset is changed by adjusting the vertical offset control located on the plug-in module front panel. The control should be adjusted to center your sig­nal within the 5V peak-to-peak (12 volts peak-to-peak for slow signals) dynam­ic range of the probe.
Available Accessories
Cleaning the N1022A
The following accessory is available from Agilent.
8 in-lbs torque wrench: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P/N 8710-1764
If the probe adapter requires cleaning, disconnect it from both the instrument and the probe. Wipe with a soft cloth dampened with a mild soap and water solution. Make sure the adapter is completely dry before reconnecting to the probe and instrument.

Inspecting the N1022A

Inspect the shipping container for damage.
Keep a damaged shipping container or cushioning material until the contents of the shipment have been checked for completeness and the probe adapter has been checked mechanically and electrically.
Inspect the probe adapter.
• If there is mechanical damage or defect, or if the probe adapter does not
operate properly or pass performance tests, notify your Agilent
4