Agilent Technologies 8510C User Manual

The Agilent Technologies 8510C is a modular family of compatible products. For flexibility in specifying a solution that meets your exact needs, a system is typically ordered as separate line items. For those who wish ordering convenience, complete bundled systems are available. Whether ordering individual components or a bundled sys­tem, all 8510C network analyzers include one-year, on-site service. For systems built from individual components, installation may be ordered sepa­rately. A PC running BASIC Rev 6.3 or higher under Windows® (3.1/95/NT) is recommended for installation and service.
Complete systems
Agilent 8510XF family 110 GHz single sweep systems
(45 MHz to 110 GHz) The 8510XF family has two models which are complete single-connection, single-sweep vector network analyzer systems that offer S-parameter measurements over an ultra-broadband frequency in a 1.0 mm coaxial connector. The broadest fre­quency model covers 45 MHz to 110 GHz. A lower frequency model is available covering 45 MHz to 85 GHz. Both systems are designed to facilitate easy connection to wafer probe hardware while still preserving excellent RF measurement perform­ance. In addition, the system can be used to make coaxial measurements (to interface to a coaxial fix­ture or a coaxial DUT) using the same millimeter head configuration.
Agilent E7340A single-connection single-sweep network analyzer system (2 to 85 GHz)
The E7340A is a complete system configured with an 8510C, a 20 GHz and 50 GHz synthesizer, two 85 GHz S-parameter test heads, and a millimeter test set controller. The instruments are integrated in the system rack, the system is fully tested, and a complete system verification is performed prior to shipment from Agilent. Installation is included at no additional charge. The E7340A system does not include calibration kits or test port cable sets. System components include:
8510C network analyzer E7342A millimeter subsystem 83621B synthesizer 83651B synthesizer System rack
Calibration kits and test port cables are not included and must be ordered separately.
Test set options
E7340A-STD Standard configuration
E7340A-005 Add (45 MHz to 2 GHz) low
frequency extension
E7340A-006 Add RF pass thru (provides coupled
output of 50 GHz source for additional test set(s). Additional test set(s) must have Option 001 installed)
E7340A-056 Low frequency extension and RF
pass through
Features
8510C-010 Add time domain
Voltage options
E7340A-115 110/120 V line voltage operation
E7340A-230 220/240 V line voltage operation
Extended service options are available.
Agilent 8510C Network Analyzer Family
45 MHz to 110 GHz
Configuration Guide
2
Agilent E7350A single-connection single-sweep network analyzer system (2 to 110 GHz)
The E7350A is a complete system configured with an 8510C, a 20 GHz and 50 GHz synthesizer, two 110 GHz S-parameter test heads, and a millimeter test set controller. The instruments are integrated in the system rack, the system is fully tested, and a complete system verification is performed prior to shipment from Agilent. Installation is included at no additional charge. The E7350A system does not include calibration kits or test port cable sets.
System components include:
8510C network analyzer E7352A millimeter subsystem 83621B synthesizer 83651B synthesizer System rack
Calibration kits and test port cables are not included and must be ordered separately.
Test set options
E7340A-STD Standard configuration
E7340A-005 Add (45 MHz to 2 GHz) low
frequency extension
E7340A-006 Add RF pass thru (provides
coupled output of 50 GHz source for additional test set(s). Additional test set(s) must have Option 001 installed)
E7340A-056 Low frequency extension and RF
pass through
Features
8510C-010 Add time domain
Voltage options
E7340A-115 110/120 V line voltage operation
E7340A-230 220/240 V line voltage operation
Extended service options are available.
Agilent 85107B network analyzer system
(45 MHz to 50 GHz)
The 85107B is a complete system configured with a 50 GHz synthesizer, 50 GHz S-parameter test set, and 2.4 mm measurement accessories. The instru­ments are integrated in the system rack, the system is fully tested, and a complete system verification is performed prior to shipment from the factory. Installation is included at no additional charge.
System components include:
8510C network analyzer 8517B test set with Option 002 (deleted step attenuators and bias tees) 83651B synthesizer 85056A calibration kit 85133F cable set 85043C rack
Test set options
85107B-STD Standard configuration
85107B-005 Add attenuators and bias network
(not compatible with 85107B-STD)
85107B-007 High power and high dynamic
range configuration (requires 85107B-005)
Source options
85107B-51B Standard 50 GHz synthesized
sweeper, no front panel
85107B-50B 50 GHz synthesized source with
front panel
85107B-50L 50 GHz CW synthesized source
with front panel
Features
8510C-010 Add time domain
Voltage options
85107B-115 110/120 V line voltage operation
85107B-230 220/240 V line voltage operation
Accessories
85107B-002 2.4mm calibration kit and cables
85107B-001 3.5mm calibration kit and cables
85107B-E33 Do not include 2.4mm kit and
cables (not compatible with 85107B-002)
Extended service options are available.
3
Agilent 8510SX network analyzer system
(45 MHz to 26.5 GHz) The 8510SX is a complete system configured with a 26.5 GHz synthesizer, 26.5 GHz S-parameter test set, and a complete set of 3.5 mm measurement accessories. The instruments are integrated in the system rack, the system is fully tested, and a com­plete system verification is performed prior to shipment from the factory. Installation is included at no additional charge.
System components include:
8510C network analyzer 8515A test set 83631B synthesizer 85043C rack 85052C calibration kit 11752D gauge kit 85131F cable set
Features
8510C-010 Add time domain
Voltage options
8510SX-115 110/120 V line voltage operation
8510SX-230 220/240 V line voltage operation
Accessories
8510SX-001 7 mm accessories (85052C and 85132F)
Extended service options are available.
Agilent 8510E network analyzer system
(45 MHz to 20 GHz) The 8510E is a complete unracked system config­ured with a 20 GHz synthesizer, 20 GHz S-parame­ter test set, and 3.5 mm connector accessories. Installation is not included.
System components include:
8510C network analyzer 8514B test set with Option 002
(deleted step attenuators and bias tees) 83621B synthesizer 85052D calibration kit 85131D cable set
Test set attenuation options
• 8510E-STD Standard configuration
8510E-002 Add attenuator and bias network
Features
• 8510C-010 Add time domain
Calibration kit options (select one)
• 8510E-004 3.5mm economy calibration kit
8510E-005 3.5mm precision calibration kit
Extended service options are available.
Agilent 85106D millimeter-wave network analyzer subsystem (33 GHz to 110 GHz)
When combined with the appropriate 85104A series test set modules (see page 6) and 11644A series calibration kits, the 85106D provides a complete system for measurements in the milli­meter-wave frequency range. The instruments are integrated in a 1600 mm system rack. It is fully tested and a complete system verification is per­formed prior to shipment from the factory. Installation is included at no additional charge.
The 85106D system consists of:
8510C network analyzer 85105A test set controller 83621B synthesizer (2 total) 1600 mm rack
Must also order appropriate 85104A series test set modules and 11644A series calibration kit for complete system.
Frequency range (select one)
85106D-STD 33 - 110 GHz
85106D-001 45 MHz - 110 GHz, adds 8517B and
needed accessories
85106D-007 45 MHz - 110 GHz, high power/high
dynamic range
Features
8510C-010 Add time domain
Voltage options
85106D-115 110/120 V line voltage operation
85106D-230 220/240 V line voltage operation
Extended service options are available.
4
Agilent 85108A pulsed-RF network analyzer system
(2 GHz to 20 GHz) Based on an 8510C with Option 008, this system provides the capability to measure the amplitude and phase response of a device or component being driven with a pulsed-RF input signal. The instruments are integrated in a 1600 mm system rack. It is fully tested and a complete system verifi­cation is performed prior to shipment from the factory. Installation is included at no additional charge.
System components include:
8510C network analyzer with Option 008
(pulsed-RF measurement capability) 85110A test set 1600 mm rack 83622B synthesizer with Options 001/004/008 83623L synthesizer with Options 004/008
Calibration kits and test port cables in the appropriate connector interface are not included and must be ordered separately.
Frequency range (select one)
85108A-STD 2 - 20 GHz
85108A-E63 500 MHz - 20 GHz
85108A-F61 2 - 50 GHz with front panel connectors
85108A-F62 45 MHz - 50 GHz
Features
8510C-010 Add time domain
Voltage options
85108A-115 110/120 V line voltage operation
85108A-230 220/240 V line voltage operation
Extended service options are available.
Agilent 85108L pulsed-RF network analyzer system
(45 MHz to 2 GHz) Based on an 8510C with Option 008, this system provides the capability to measure the amplitude and phase response of a device or component being driven with a pulsed-RF input signal. The instruments are integrated in a 1600 mm system rack, the system is fully tested, and a complete sys­tem verification is performed prior to shipment from the factory. Installation is included at no additional charge.
System components include:
8510C network analyzer with Option 008
(pulsed-RF measurement capability) 85110L test set 1600 mm rack 83620B synthesizer with Options
001/004/008/H80 83620B synthesizer with Options 004/008/H80
Calibration kits and test port cables in the appropriate connector interface are not included and must be ordered separately.
Features
8510C-010 Add time domain
Voltage options
85108L-115 110/120 V line voltage operation
85108L-230 220/240 V line voltage operation
Extended service options are available.
Agilent 85122A high frequency device modeling system
(45 MHz to 20 GHz) When combined with the 85190 series high frequency IC-CAP software, along with Cascade probes or ICM fixtures, the 85122A can be used to model BJT, FET, MOS, and diode devices. All instruments are integrated in a 1600 mm system rack prior to shipment from the factory. Installation is included at no additional charge.
System components include:
8510C network analyzer 8514B test set 83621B synthesizer 11612A Option K10/K20 force/sense bias networks 4156C DC source/monitor 85131F cable set 1600 mm rack
Probes, fixtures, calibration kits, 85190 series software, and workstation must be ordered separately.
Option 230 provides system cabinet set up for
220/240 V operation
Custom configurations available to meet other frequency coverage and power requirements.
5
System components
For flexibility in specifying a solution that meets your exact needs, a system can be ordered as sepa­rate line items. A complete system includes the Agilent 8510C network analyzer, a test set, compat­ible source, and measurement accessories.
All major system components (network analyzer, test sets, and sources) include one-year on-site service.
8510C ATO options
8510C-008 Pulsed-RF capability requiring 85110A
or 85110L S-parameter test set
8510C-010 Add time domain
Rack flange kits
8510C-908 Rack flange kit, front handles detached
8510C-913 Rack flange kit, front handles attached
Additional documentation
8510C-910 Extra operating and service manual
set
8510C-916 Extra operating and programming
manual set
Extended service options are available.
Test sets (Choose one)
8514B S-parameter test set (45 MHz to 20 GHz)
With rugged 3.5 mm connector test ports
8515A S-parameter test set (45 MHz to 26.5 GHz)
With rugged 3.5 mm connector test ports
8517B S-parameter test set (45 MHz to 50 GHz)
With rugged 2.4 mm connector test ports
85110A pulsed-RF S-parameter test set (2 to 20 GHz)
For use with 8510C Option 008. Includes rugged
3.5 mm connector test ports and four built-in step attenuators to independently set power level to all four downconverter channels. Requires 8360 series synthesized sources for complete operation (83622B and 83623L).
85110L pulsed-RF S-parameter test set (45 MHz to
2 GHz) For use with 8510C Option 008. Includes rugged 7 mm connector test ports and four built-in step attenuators to independently set power level to all four downconverter channels. Requires two 8360 series synthesized sources for complete operation (83620B-H80, two each).
8511A frequency converter (45 MHz to 26.5 GHz)
3.5 mm connector ports
8511B frequency converter (45 MHz to 50 GHz)
2.4 mm connector ports
Note: Agilent 8511A/B require external, customer­furnished couplers, or signal separating devices to provide complete test set capability. A source with front panel RF power output may be more suitable for 8511-based applications.
Test set options
Option Description 8514B 8515A 8517B 85110A 85110L 8511A/B
STD No IF switching X X
001 Add IF switching for multiple test set operation X X X X X X
002 Delete step attenuators and bias tees X X X
003 High forward dynamic range configuration X
(degrades reverse transmission dynamic range)
003 Add attenuators and bias tees X X
999 Standard input power X
004 High power configuration (moves port 2
attenuator in front of b2 sampler) X
004 Add attenuators and bias tees X
027 High source power X
908 Add rack flange kit X X
913 Add rack flange and handles kit X X X X
910 Extra operating and service manual X X X