5
System components
For flexibility in specifying a solution that meets
your exact needs, a system can be ordered as separate line items. A complete system includes the
Agilent 8510C network analyzer, a test set, compatible source, and measurement accessories.
All major system components (network analyzer,
test sets, and sources) include one-year on-site
service.
8510C ATO options
• 8510C-008 Pulsed-RF capability requiring 85110A
or 85110L S-parameter test set
• 8510C-010 Add time domain
Rack flange kits
• 8510C-908 Rack flange kit, front handles detached
• 8510C-913 Rack flange kit, front handles attached
Additional documentation
• 8510C-910 Extra operating and service manual
set
• 8510C-916 Extra operating and programming
manual set
Extended service options are available.
Test sets (Choose one)
• 8514B S-parameter test set (45 MHz to 20 GHz)
With rugged 3.5 mm connector test ports
• 8515A S-parameter test set (45 MHz to 26.5 GHz)
With rugged 3.5 mm connector test ports
• 8517B S-parameter test set (45 MHz to 50 GHz)
With rugged 2.4 mm connector test ports
• 85110A pulsed-RF S-parameter test set (2 to 20 GHz)
For use with 8510C Option 008. Includes rugged
3.5 mm connector test ports and four built-in
step attenuators to independently set power
level to all four downconverter channels.
Requires 8360 series synthesized sources for
complete operation (83622B and 83623L).
• 85110L pulsed-RF S-parameter test set (45 MHz to
2 GHz)
For use with 8510C Option 008. Includes rugged
7 mm connector test ports and four built-in step
attenuators to independently set power level to
all four downconverter channels. Requires two
8360 series synthesized sources for complete
operation (83620B-H80, two each).
• 8511A frequency converter (45 MHz to 26.5 GHz)
3.5 mm connector ports
• 8511B frequency converter (45 MHz to 50 GHz)
2.4 mm connector ports
Note: Agilent 8511A/B require external, customerfurnished couplers, or signal separating devices to
provide complete test set capability. A source with
front panel RF power output may be more suitable
for 8511-based applications.
Test set options
Option Description 8514B 8515A 8517B 85110A 85110L 8511A/B
STD No IF switching X X
001 Add IF switching for multiple test set operation X X X X X X
002 Delete step attenuators and bias tees X X X
003 High forward dynamic range configuration X
(degrades reverse transmission dynamic range)
003 Add attenuators and bias tees X X
999 Standard input power X
004 High power configuration (moves port 2
attenuator in front of b2 sampler) X
004 Add attenuators and bias tees X
027 High source power X
908 Add rack flange kit X X
913 Add rack flange and handles kit X X X X
910 Extra operating and service manual X X X