1. Hood body
2. Cable suspension
3. Cable support
4. Decorative disc
5. Hanger bolt
6. Dowel
7. Metal filter with ionizer sheet, with spring lock
8. Cable for ionizer sheet
9. Receptacle for wire suspension
Page 2
10. Heat detector
11. Grease collector
12. Halogen lamp 20 Watt
13. Germicidal lamp (UV-C Lamp) EKL
14. Stainless steel filter 586x324 mm incl. activated carbon
15. Power cord outlet
EFA 1020.1/1030 Air Cleaning Center (Ceiling Mounted) with Cable Suspension
EFA 1020.1/1030 Air Cleaning Center (Ceiling Mounted) with Cable Suspension
EFA 1020.1/1030 Air Cleaning Center (Ceiling Mounted) with Cable Suspension EFA 1020.1/1030 Air Cleaning Center (Ceiling Mounted) with Cable Suspension
Installation Instructions
Installation Instructions–––– Instructions for Use
Installation InstructionsInstallation Instructions
In order to be able to use your exhaust hood in the best possible manner, please read these intructions carefully and keep them in case they are needed.
1. Safety and General notes
1. Safety and General notes
1. Safety and General notes1. Safety and General notes
The exhaust hood can only be connected to a properly installed power outlet or connected directly
by a professional. The power outlet mus be as secure as possible directly in the junction box. The electrical data is found on the nameplate, after opening the grease collector (11), behind the stain­less steel filter (14), in the interior of the device.
The connection and commissioning may only be carried out by a professional.
Never use the exhaust hood without a filter (7/14) and open grease collector (11).
Always use gas burners properly.
Accessible parts can become hot while cooking or when they are used with cooking utensils!
The gas burner flames must always be covered with cookware. Strong heat development of open
flames could damage the exhaust hood.
The exhaust hood‘s power supply must be interrupted by pulling the plug before conducting any
cleaning or maintenance work.
Flambee dishes must not be prepared under the exhaust hood. The open flame could cause a fire.
Never leave the pan unsupervised when frying food. The oil could start a fire.
Constant maintenance ensures perfect operation and optimal performance of the exhaust hood.
All contaminated surfaces should be cleaned of debris regularly. The filter must be removed and
cleaned regularly. (see page 11).
Incorrect halogen lamps (12) could ruin the transformer.
The device can swing freely because it is attached to the ceiling with steel cables.
Do not allow the heat sensor to react to a flame.
Keep a minimum distance of 300 mm between the ceiling and the upper side of the hood.
Minimum dstance between the storage surface of the cooking vessels on the hob and the lowest
part of the exhaust hood: This distance must be at least 65 cm if the exhaust hood is installed abo­ve a gas appliance. If the mounting instructions for the hob specify a greater distance, this distance is to be adhered to. This minimum distance also applies to electric stoves.
This unit must not be used by persons, including children with reduced physical, sensory or mental
abilities, or by persons without experience and knowledge unless they are supervised by a person who is responsible for their safety and has been instructed on the use of this equipment.
Children must not be unsupervised in the vicinity of the unit and must not play with the unit under
any circumstances.
Safety Shutdown:
Safety Shutdown:
Safety Shutdown:Safety Shutdown: If one or more filters are removed, the unit switches off automatically. The unit is operational once again only after the the correct positioning of the filter.
CAUTION: Accessible parts may become hot when used with cooking appliances.
!!! Operate this unit only with inserted filters (7/14) and a closed grease collector (11) !!!
3
Instructions for Use
Instructions for Use Instructions for Use
!!! Do not operate this unit without a filter (7/14)
!!! Do not operate this unit without a filter (7/14)
!!! Do not operate this unit without a filter (7/14) !!! Do not operate this unit without a filter (7/14)
(High voltage and UV
(High voltage and UV----C radiation)
Do not look into the illuminated germicide lamp (13) !!!
Do not look into the illuminated germicide lamp (13) !!!
Do not look into the illuminated germicide lamp (13) !!! Do not look into the illuminated germicide lamp (13) !!!
(High voltage and UV (High voltage and UV
C radiation)
C radiation)C radiation)
Page 3
2. Before Installation
2. Before Installation
2. Before Installation2. Before Installation
The following parts are in the package: hood body, stainless steel filter, accessory kit and cleaning
kit (the cable suspensions are in the accessory kit).
Check that the exhaust hood was not damaged during transport. If there is any damage, the unit
must not be installed.
Make sure that the installation and the electrical connections have been conducted by a qualified
technician according to the specifications of the manufacturer and the official regulations.
Make sure that a 3-wire power cable is present on the site which comes from the ceiling on the
right side behind the cable suspension.
Caution: The electrical connection must be performed by a licensed electrician. The plug must be
accessible after installation. A Type 12 or Type 13 power outlet is to be provided. The connection cable is 2.4 metres long.
Caution: If the unit is to be used with as a fixed connection rather than with the plug, a separator belonging to that only must be available.
Caution: The power supply to the hood must be unplugged before conducting maintenance work.
Page 4
3. Installation
3. Installation
3. Installation3. Installation
Caution!!
Caution!! The connection to the 230 Volt network as well as the entire installation of the exhaust hood
Caution!! Caution!! must be at absolute zero potential
1. Workflow:
2. Workflow:
Skizze 1 Skizze 2
3. Workflow: Take four dowels, four hanger bolts and four decorative discs from the accessories kit. Insert the four dowels, screw in the four hanger bolts, and screw the four decorative discs onto the hanger bolts.
4. Workflow: Now unpack the hood body.
5. Workflow: Thread the cable suspension with the cable clamp from above into the hood body. Screw the cable clamp into the mounting and secure with the set screw. One mounting per cable suspension.
6. Workflow: Now screw the four wire cables with the cable supports onto the hanger bolts. Now the steel cable can get twisted but it will ‘untwist‘ during workflow 7.
7. Workflow: The wire cable relaxes and the length of the steel cable can be varied by exerting pressure onto the cable clamp. The hood can be aligned using a water level.
8. Workflow:
9. Uncover the hood after installation only so that no dirt particles can reach the top of the hood.
5
at absolute zero potential and conducted by a professional.
at absolute zero potential at absolute zero potential
Carry the middle of the cooktop to
Draw four drill holes on the ceiling and then drill the four holes. (Sketch 1 = IH EFA 1020.1; Sketch 2 = IH EFA 1030)
Fasten the power cord of the hood to the feed line on site.
The unit can be uncovered again only once the kitchen has been completely set up and the final cleaning has taken place.
middle of the cooktop to the ceiling.
middle of the cooktop to middle of the cooktop to
Page 5
Loading...
+ 11 hidden pages