Installation
When installed. the hood must be not less than 60
cm. above electric burners or 70 cm. above gas or
mixed-fuel burners. In the vented exhaust version
the fumes outlet duct must be 100-120 mm. in
diameter. In the horizontal runs the duct must be
slightly slanted (about 10°) and directed upwards
to vent the air easily from the room to the outside.
Electric connection
Before completing any connection, make sure the
house voltage corresponds with the voltage
indicated on the label affixed inside the hood
The hood may be supplied with a standard plug
Attention
— No food must be cooked flambeau underneath
hood, when it exhausts the air, removes the
ambient air the burners or fireplace need for
combustion.
For safe operation and to prevent discharged
gas from coming back into the room, make
sure there is an air inlet .which may be provided
through air-recycling doors, windows or wall
boxes or by other technical devices.
the hood.
— If the hood is run at the same time as an
ambient-air dependent burner or fireplace (for
example gas, diesel, coal or wood heaters,
water heaters, etc.), be careful, because the
A non-return fume valve is available as an optio-
nal. This fits on the coupling ring (Fig. 4)
Internal recycle system (filtering)
The air is recycled into the room through the front
grid.
Lever F: in position F (fig. 3).
There are two carbon filter models available:
Circular: with bayonet attachment —
rotate in clockwise direction (fig. 5).
Rectangular: fits on the frame G and snaps
into place on the conveyor (fig. 6)
— Fit 3 0,8 mm wall plugs
— Fit 2 5x45 screws on H—do not tighten
Using the hood
It is advisable to switch on the extractor hood a few
minutes before starting cooking and then to leave
it running for approximately 15 minutes afterwards
to ensure that all odours are extracted. On the
front part of the appliance there are the control
switches, which change according to the type of
hood (see electrical sketches enclosed) .
— Now hang the hood (holes H). Tighten the 2
completely
screws and fit the third 5x45 screw in hole I
from inside the cabinet (fig. 8).
To connect the pipe fit the coupling ring “C” in the
outlet selected. Use cover “D” to close the unused
outlet (fig. 1).
Important: When using the rear exhaust outlet
open the hole on the conveyor by pulling the tabs
E (fig. 2).
Lever F: in position A (fig. 3).
Fixing to the wall
— Fit the template to the wall
— Make 3 8 mm Ø holes on the wall. 2 on H, and
the cabinet in the holes on the appliance
1 hole on any of points I, as required.
(fig.7).
at the top “A” and the other at the back “B”.
between contacts of not less than 3 mm.
The manufacturers are not liable for any problems
caused by the user’s failure to observer the above
Fixing to the cabinet
— Make holes at the bottom of the cabinet using
— Fit the 4 4.2x35 screws supplied, from inside
the template supplied
GB
and if so connect it to a correspondingly standard
socket.
If the appliance is not fitted with a plug, either fit a
plug conforming to regulations or a two-pole switch
conforming to regulations with an opening distance
Use
Two systems are available:
• External exhaust system
• Recycle system (filtering)
External exhaust system
The appliance is fitted with 2 exhaust outlets: one
When cleaning the grease filter, wash the grate
too with warm water and biodegradable detergent.
To dismount the filter, open the grid and remove
stop M (fig. 9).
Carbon Filter
This is not washable and can not be reused.
Circular filter:
4) The life of the metal filter is practically unlimited two months with normal use.
and should be washed the same as the synthe-
tic filter once a month and allowed to dry before
reinstalling It.
3) The tin synthetic filter (thickness about 1 mm.) mm.), is changed when the top coloring appears
on the bottom.
without saturation indicator is replaced every
in normal use is washed once a month and
replaced after 5 or 6 washinings.
Let it dry without wringing .
Cleaning
To clean the outside of the hood use a cloth
moistened with denatured alcohol or neutral liquid
detergents. Never use products containing
abrasives.
This appliance meets 87/308 EWG radio and
television noise standards.
screwed in tightly.
The grease filter traps the suspended grease
particles.
It is installed in the exhaust grate and is available
in four different versions: synthetic, thin synthetic
with saturation indicator, thin synthetic without
saturation indicator, and metal.
1) The synthetic filter (thickness about 12-15 mm)
Wash it in warm water a biodegradable detergent.
2) The thin synthetic filter (thickness about 1
Grease filter
hood fails to light up, make sure the bulbs are
— To remove, pull forward from the right hand
(fig. 9)
side and unhook.
pliance and changing and cleaning the filters may
cause fires. Therefore, we recommend observing
these instructions.
Changing the bulbs
— Disconnect the hood from the electricity.
— Remove the grate.
— Always replace burn-out bulbs with olive-sha-
— Before calling for repair service because the
ped max 40 Watt (E14) bulbs.
Maintenance
Before performing any maintenance operation,
disconnect the hood from the electricity.
Grid Opening
— Open the latch L and rotate the grid downwards
— The manufacturers refuse liability for damage
to the hood or its catching on fire because of
failure to observe the above instructions.
Attention
Failure to observe the rules for cleaning the ap-
— The hood must not be connected to fuel exhaust
The use of an unprotected flame is dangerous
for the filters and could cause fires. Therefore,
never use an open flame under the hood.
When frying foods, never leave the pan alone
because cooking oil could flare up.
flues (boilers, heating systems, water heaters,
etc).
— replace every 3/4 months for normal use
Dismounting the filter:
— rotate in anti-clockwise direction
Rectangular filter:
— replace every 6/8 months
Dismounting the filter:
— push the stops N in and pull the filter down
(fig.6).
L 298 Ed. 04/91
Montagevorschrift und Gebrauchsanleitung für die Dunstabzugshaube
Instructions on mounting and use of the cooker hood
Prescriptions de montage et mode d’emploi de la hotte aspirante
Istruzioni di montaggio e d’uso della cappa aspirante-filtrante
Monteringsanvisning og brukerveiledning for ventilator
Loading...