Easytronic Dishwashers with Flow Heater - Fully Integrated, Integrated, Built Under, Freestanding
Technical Data
Components
Interference Filter
The interference filter is connected in the terminal board parallel
to the mains feed.
Pressure Switch
The pressure switch controls the water level.
Without water, contact 11 - 12 is closed.
fNSwitch point with level 65 mm Ws
Reset point with level 45 mm Ws
fSSwitch point with safety level114 mm Ws
Reset point 90 mm Ws
The pressure switch is not adjustable.
fS
fN
16
11
17
12
14
65 mm
fS
fN
16
11
17
12
14
45 mm
Flow Heater
The flow heater heats the water to the required temperature.
During the wash cycle, water is contantly passing through the
flow heater.
H:\H1\GSP\TECHNIK\AEGHB\137201GB.P65
Power output2100 W
Resistor25 Ω
Protector98 °C ± 5 K
Thermal fuse260 °C
04.99
HV 83-N
Dishwasher
NTC-Temperaturfühler
Tem peratur/Widerstand
temperature/resistor
(nur bei vollelektron.
292 1372 4
292 1372 04
Easytronic Dishwashers with Flow Heater - Fully Integrated, Integrated, Built Under, Freestanding
Technical Data
Circulation Pump
The circulation pump is driven by an asynchronous motor with
an auxiliary winding. The auxiliary winding ist in circuit with a 4
mF capacitor. A tacho generator is used for speed control.
There are three speeds for rinsing-1600 1/min
2000 1/min
2800 1/min
Power output 50 W
Drain Pump
The drain pump is driven by a synchronous motor.
Power output 30 W.
Pump rate 15 l/min.
NTC Temperature Sensor
Temp erature sen sor NTC- r esistor
Geschirrspüler)40 °C / 2573
(only for fully electronic dishwasher)50 °C / 1741
H:\H1\GSP\TECHNIK\AEGHB\137201GB.P65
20 °C /6032
25 °C /4829
30 °C /3891
55 °C / 1444
60 °C / 1204
65 °C / 1009
70 °C / 849
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
04.99
HV 83-N
Dishwasher
Easytronic Dishwashers with Flow Heater - Fully Integrated, Integrated, Built Under, Freestanding
Technical Data
Detergent / Rinse Aid Combination Dispenser Unit
Detergent dosage = 20 ml - 30 ml
Rinse Aid capacity 150 ml
Dosage settings1 - 6
Quantity1 cm3 - 6 cm
The detergent dispenser is activated by a release coil. The first
operation adds the detergent, and the second the rinse aid. If
the door is opened, the latching bar is reset to the detergent
dosage position.
3
292 1372 5
292 1372 05
release coil
Input Module
The programs are selected via the input module, which is
mounted in the door. All components are connected to this
module.
Output Module
Depending on models displays are integrated into the output
module.
osalt
orinse aid
owater
ofilter
odisplay
oresidual run time
odelay start
ofault display
owater hardness
oprogram cycle display
H:\H1\GSP\TECHNIK\AEGHB\137201GB.P65
Fully integrated control Panel
1Input module
2Output module
04.99
HV 83-N
12
Dishwasher
Easytronic Dishwashers with Flow Heater - Fully Integrated, Integrated, Built Under, Freestanding
Technical Data
Electronic
On electronic models, a micro processor controls all
components, this is done using triacs. The electronic also
memorizes all programme data.
Drying Fan
292 1372 6292 1372 06
2
The drying fan sucks the humid air from the
tub, and mixes it with dry air which is drawn up
from in between the door panels (1) and blows
it out through a vent situated below the door
handle (2).
During the wash cycle the fan intake vent on
the inside of the door is closed by a
thermoelectric valve (3).
Servo Door Lock
Fully integrated dishwashers have a servo door lock. Once the
program has started the door is locked automatically, however
the door can be openend by using extra effort.
1
3
H:\H1\GSP\TECHNIK\AEGHB\137201GB.P65
04.99
HV 83-N
Dishwasher
Easytronic Dishwashers with Flow Heater - Fully Integrated, Integrated, Built Under, Freestanding
Technical Data
Water Softening
The components required for water softening.
1.softener unit
2.regeneration dosage chamber
The incoming water flows through the softener which works
according to the ion exchange principle. The ion exchanger is
filled with small epoxy resin balls. The resins exchange the
hardness constituents (calcium and magnesium), for sodium
ions.
When all the sodium ions are used up, it is necessary to
regenerate the softener. This is done by flushing a brine
solution through the softener.
2
1
292 1372 7
292 1372 07
Afterwards the softener is washed out with fresh water and is now fully effective.
Depending on the water hardness, regeneration is only necessary after several wash cycles.
The softening system is designed for a water hardness of up to 50 °dH.