ONLINE STATUS DS3
FACEPLATE L EDS
ONLINE LED Description
Off Blown fuse or no power supplied to the shelf Green Online Blinking Green Offline Red Card failure Blinking Red Self-test failure Amber Self-test in progress
DS3 LED Description
Off DS3/DS1 not configured for use Green DS3/DS1 signal present & synchronized;
channel is configured for use Red DS3/DS1 alarm present Blinking Red DS3/DS1 error Amber DS3/DS1 test in progress (includes port
self-test)
STATUS LED Description
Green Active DS3 Module Blinking Green Standby DS3 - redundancy enabled Blinking Red Standby DS3 - cannot automatically become
the active DS3 while the current active DS3 is
installed
The Total Access 4303 DS3 Module requires SCU firmware of C.02 o r greater.
INSTALLATION INFORMATION
• Insert the module into the desired slot (1 through 4 only) (hot insertion permissible).
• The module connects to connectors on the backplane. Connecting the BNC Module (P/N 1200323L1) to the connectors provides t w o dual B NC connectors (see the BNC Module Quick Start, 61200323L1-13A).
• The Total Access 4303 SCU automatically detects the presence of the module. There is no need to reboot.
• Once installed, use the terminal menus to configure and control the module (see the SCU Quick Start, 61200334L1-13A).
• Use the arrow k eys on t he VT100 ter m inal keyboard to move to the Modules menu; press Enter in the Menu column of the appropriate module.
SPECIFICATIONS
Framing M13 or C-Bit Parity Line Coding B3ZS (bipolar 3 zero substitution) Line Build Out 0 to 50 feet (Short)
51 to 450 feet (Long)
Tests Self-test
Local Line and Payload Loopbacks Remote Line and Payload Loopbacks
Line Rate 44.736 Mbps + Terminating
Impedance
75 ohms +
895 bps
5%, unbalanced
Power 9 watts Compliance FCC Part 15, UL 60950 Temperature
Operation: 0 Storage: – 40
o
C to 50oC
o
C to 70oC
Relative Humidity To 95% noncondensing Warranty 10 years
Quick Start Technical Support (800) 726-8663 61200333L1-13B
TOTAL ACCESS® 4303 DS3 MODULE
MENU TREE FOR THE DS3 MODULE TERMINAL MENUS
Part Number Prt Serial Number Clear
DS3 Info CLEI Code Prt ES_L
Board Revision Alarms SES_L DS3 Alarm Status FE Alarms LOSS_L DS3 Perf Rx Framing CV_P (Curr, 15 Min, & 24 Hr) ES_P
Slt Prt SES_P Type DS3 Configuration Port Name UAS_P
Modules Menu Frame
Alarm TX Clock Prt Test LBO LoopBack State DS3 Test Remote LB Prt Rev Remote Status RED CLR
DS1 Alarm Status Prt YELLOW ES DS1 DS0 Status Alarms BLUE BES DS1 DS0 Alarm DS0 Alar m SES DS1 Sig Status SEFS DS1 Perf LOFC (Curr, 15 Min, & 24 Hr) CSS
DS1 Config Port Name
Prt TX Yel
Loc LB TX PRM
Remote LB LB Accept
Pattern Rmt Mgmt
QRSS/RLB ADLP DS1 Test Results Disabled
CLR 1E-03
INJ Module Redundancy 1E-04
Redundancy Minimum Switch Time 1E-06
October 2001
Prt PCV
Frame
Error Threshold 1E-05