OPTI-3 Wallmount Chassis (WMC)
61184001L1-22C
0504
OPTI-3
WMC
CLEI: SOM1500L_ _
P/N 1184001L1
*61184001L1-22C*
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
STATUS
OPTICS
DS3-1
DS3-2
APS
DS3-3
ACO
TEST
ACO
ENABLE
STATUS
OPTICS
DS3-1
DS3-2
APS
DS3-3
ACO
TEST
ENABLE
OPTI-3
11
84
00
2
L
OPTI-3
1
1
8
4
0
0
1
2
L
1
WMC
ACO
Figure 1. OPTI-3 WMC
DESCRIPTION
The OPTI-3 Wallmount Chassis (WMC) mounts to a wall or shelf and hosts two
redundant OPTI-3 Controller Modules (OCM). The WMC provides six BNC
connectors on the chassis backplane, corresponding to the Tx/Rx of the three DS3
interfaces.
The following features are supported on the WMC:
♦ Dimensions: 3.5 inches (2U) H × 6.25 inches W × 11.5 inches D
♦ Provides one OC-3-to-three-DS3 multiplexing capability
♦ Wire wrap pins for three external alarm inputs
♦ Primary and secondary DS1 BITS clock inputs
INSTALLATION
To ins tall the WMC, perform the following steps:
1. Inspect the WMC for damage. If damage is found, file a claim with the carrier
then contact ADTRAN® Customer Support.
2. Position the mounting brackets in an orientation that positions the ears of the
brackets flush with the mounting surface. Attach the brackets to the WMC using
the provided screws and the pre-tapped holes on the sides of the WMC.
3. Using the appropriate screws for the mounting surface to which the WMC will be
attached, mount the WMC in the desired location.
4. Using 14 to 18 gauge wire (14 recommended), make the connection from the
frame ground terminal on the backplane of the WMC to an earth ground.
WARNING: Make the frame ground wire at least the same gauge as the power
wire or heavier.
5. Test the frame ground connection to ensure proper ground: Using a multimeter
set to its lowest resistance range, place one lead on the earth ground and the other
lead on the WMC frame ground terminal. The reading should be less than 0.1
ohms. Greater readings should be investigated.
For more information, refer to the OPTI-3 OCM Installation and Maintenance Practice (P/N 61184002L5-5) available online at www.adtran.com.
POWER CONNECTIONS
NOTE: Use one of the following methods when powering the unit locally:
a) Connect to a reliably grounded –48 VDC source, which is electrically
isolated from the AC source. The branch cir cuit overcurrent protection shall
be a fuse or circuit breaker rated minimum 60 VDC, maximum 15A. A
readily accessible disconnect device (such as a rackmount fuse and alarm
panel that is suitably approved and rated) should be incorporated in the
fixed wiring.
b) Connect to an Approved Class 2 Type (LPS) power supply rated 48 VDC,
maximum 240 VA.
To Provide Power Using a –48 VDC Source:
1. Determine which fuse pairs are to supply power to the shelf.
NOTE: The OPTI-3 WMC will function properly with a single –48 DC power source
connected to either the A or B terminals, or two separate –48 VDC sources
connected to A and B power terminals.
2. Remove the fuses from the A and B slots for the pair.
3. Cut four lengths of 16 or 18 gauge (16 recommended) conductors to reach from
the terminals on the fuse and alarm panel to the power terminals on the WMC.
WARNING: The power wire gauge should not be heavier than the ground wire.
4. Using a crimping tool, connect lugs to both ends of each wire.
5. Using a screwdriver, connect the ends of one wire between the “A” CO –48 VDC
supply to the
6. Connect the three remaining power wires in the same manner:
a. Connect the “A” CO –48 VDC return to
b. Connect the “B” CO –48 VDC supply to
c. Connect the “B” CO –48 VDC return to RET B
To Provide Power Using the OPTI-3 AC to –48 VDC Power Supply:
The OPTI-3 AC to –48 VDC Power Supply Assembly (P/N 4184004L1) includes:
♦ AC to –48 VDC power supply (P/N 1175043L2)
♦ Adapter (P/N 3125069@A)
To use the Power Supply Assembly, perform the following steps:
WARNING: Do not connect the power supply to an AC power source at this point.
1. Connect the end of the adapter with the 4-pin modular connector to the end of the
power supply cord with the 4-pin modular connector.
2. Connect the end of the adapter with the three loose wires to the rear of the WMC:
a. Connect the red wire to
b. Connect the black wire to the adjacent
c. Connect the green wire to the terminal labeled with the ground symbol.
3. For redundant power, repeat step 2 for the
ground, using the wires from the redundant power supply.
NOTE: For redundant power, A and B feeds share the same ground terminals.
–48VA terminal on the WMC backplane.
RET A
–48 VB
–48VA.
RET terminal.
–48VB power terminal, RET, and
OPTI-3 Wallmount Chassis (WMC)
Figure 2. WMC Backplane Connectors
Apply Power and Check Voltage
WARNING: Installing fuses in the fuse and alarm panel or connecting the power supply to an AC
source at this stage provides power to the shelf, the pins on the backplane, and inside
the shelf. Exercise caution to avoid elect ri c s hoc k.
1. Without an OCM installed in the WMC, install 1A fuses in the fuse and alarm panel slots servicing
the OPTI-3 WMC shelf. (If using the AC Power Supply, plug the power supply into an AC outlet.)
2. Using a voltmeter, place the common (normally black) lead on the A
DC volts (normally red) lead on the
–48VA power terminal. The reading should be in the oper ating
range of –42 VDC to –56 VDC, with a nominal value of –48 VDC.
3. If redundant power is supplied, repeat step 2 for the B
RET and –48VB.
4. Remove the fuses from the fuse and alarm panel serving the WMC until power is required.
ADDITIONAL CONNECTIONS
Connect External BITS Clock
If an external BITS clock is to be used, perform the following steps:
1. Determine the +, – and ground wires from the primary CO clock source.
2. Locate the external clock input wire-wrap pins on the backplane of the WMC. There are two sets of
pins labeled
3. Wire-wrap the + wire from the clock source to the pin marked
4. Wire-wrap the – wire from the clock source to the pin marked
5. Wire-wrap the ground wire from the clock source to the pin marked with
symbol.
6. Tie the clock source wires neatly to the frame.
7. If a secondary BITS clock source is to be supplied, repeat steps 1 through 6 for
EXT CLK PRI and EXT CLK SEC.
RET power terminal and the
PRI +.
PRI –.
PRI and the ground
SEC.
PRICING AND AVAILABILITY 800.827.0807
TECH SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61184001L1-22C
Connect DS3 Interface Cabling
Connect the DS3 interface cable to the proper BNC connectors on the rear of the chassis. Each of the
three pairs of BNC connectors are labeled
the BNC connectors) corresponding to which DS3 the connector is mapped.
from the previous network element (NE), and
IN (top) and OUT (bottom) along with the number (between
IN receives the DS3 signal
OUT transmits DS3 signal to the next NE.
Connect Alarm Inputs
There are three auxiliary alarm inputs provided by the OPTI-3 WMC using wire wrap pins, labeled
AUX 1, AUX 2, and AUX 3
NOTE: These inputs only operate when the OCM is installed.
Any on-site equipment that might need to pass an alarm through the network can use these contacts.
The priority of these contacts can be set to Critical, Major, Minor, or None using the OCM menus. An
alarm is triggered when any pair of wire-wrap pins is shorted.
Connect to LAN
The OPTI-3 WMC provides an RJ-45 connection for network management over Ethernet, located on
the backplane and labeled
ETHERNET.
NOTE: The Ethernet Interface is only intended to be connected to intra-building wiring.
Optical Connections
All OC-3 connections are made using the connection points on the OCM. For more information
concerning installing the OCM and making the optical connections, see the OPTI-3 Controller Module
Installation and Maintenance Practice (P/N 61184002L5-5) or Job Aid (P/N 61184002L5-22).
COMPLIANCE
Per GR-1089-CORE October 2002, Section 9, this system is designed and intended only for
installation in a DC-C (common) Bonding and Grounding system. It is not intended or designed for
installation in a DC-I (isolated) Bonding and Grounding system.
The OPTI-3 Wallmount Chassis complies with NEBS Level 3 requirements. The WMC also complies
with the requirements covered under UL 60950, and is intended for installation in restricted access
locations only. The WMC must be installed in accordance with the requirements of NEC NFPA 70.
With one OCM inst alled, the WMC has a power draw of 9 W. With two OCMs installed, the WMC has
a power draw of 16 W. The following table provides the compliance codes for the OPTI-3 WMC.
Code Input Output
Power Code (PC) F C
Telecommunications Code (TC) – –
Installation Code E –
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service.
Warranty information can be found online at www.adtran.com/warranty
.