ADTRAN OCU 45 User Manual

OCU 45 User Manual
Part Number 1200664L1,2,3,4 Document Number 61200664L1-1C
61200664L1-1C January 2005
Trademarks
Any brand names and product names included in this manual are trademarks, registered trademarks, or trade names of their respective holders.
To the Holder of the Manual
The contents of this manual are current as of the date of publication. ADTRAN reserves the right to change the contents without prior notice.
In no event will ADTRAN be liable for any special, incidental, or consequential damages or for commercial losses even if ADTRAN has been advised thereof as a result of issue of this publication.
901 Explorer Boulevard
P.O. Box 140000
Huntsville, AL 35814-4000
Phone: (256) 963-8000
Copyright ©2005, Inc.
All Rights Reserved.
Printed in U.S.A.
Notes provide additional useful information.
Cautions signify information that could prevent service interruption.
Warnings provide information that could prevent damage to the equipment or endangerment to human life.
Safety Instructions
When using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury:
1. Do not use this product near water, such as a bathtub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool.
2. Avoid using a telephone (other than a cordless-type) during an electrical storm. There is a remote risk of shock from lightning.
3. Do not use the telephone to report a gas leak in the vicinity of the leak.
4. Use only the power cord, power supply, and/or batteries indicated in the manual. Do not dispose of batteries in a fire. They may explode. Check with local codes for special disposal instructions.
Save These Important Safety Instructions
3
Federal Communications Commission Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio frequencies. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Shielded cables must be used with this unit to ensure compliance with Class A FCC limits.
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
4
Industry Canada Compliance Information
Notice: The Industry Canada label applied to the product (identified by the Industry Canada logo or the “IC:” in front of the certification/ registration number) signifies that the Industry Canada technical specifications were met.
Notice: The Ringer Equivalence Number (REN) for this terminal equipment is supplied in the documentation or on the product labeling/ markings. The REN assigned to each terminal device indicates the maximum number of terminals that can be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices should not exceed five (5).
Canadian Emissions Requirements
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference­causing equipment standard entitled “Digital Apparatus,” ICES-003 of the Department of Communications.
Cet appareil numérique respecte les limites de bruits radioelectriques applicables aux appareils numériques de Class A prescrites dans la norme sur le materiel brouilleur: “Appareils Numériques,” NMB-003 edictee par le ministre des Communications.
5
Warranty and Customer Service
ADTRAN will repair and return this product within 10 years from the date of shipment if it does not meet its published specifications or fails while in service. For detailed warranty, repair, and return information refer to the ADTRAN Equipment Warranty and Repair and Return Policy Procedure.
Return Material Authorization (RMA) is required prior to returning equipment to ADTRAN.
For service, RMA requests, or further information, contact one of the numbers listed at the end of this section.
LIMITED PRODUCT WARRANTY
ADTRAN warrants that for 10 years from the date of shipment to Customer, all products manufactured by ADTRAN will be free from defects in materials and workmanship. ADTRAN also warrants that products will conform to the applicable specifications and drawings for such products, as contained in the Product Manual or in ADTRAN's internal specifications and drawings for such products (which may or may not be reflected in the Product Manual). This warranty only applies if Customer gives ADTRAN written notice of defects during the warranty period. Upon such notice, ADTRAN will, at its option, either repair or replace the defective item. If ADTRAN is unable, in a reasonable time, to repair or replace any equipment to a condition as warranted, Customer is entitled to a full refund of the purchase price upon return of the equipment to ADTRAN. This warranty applies only to the original purchaser and is not transferable without ADTRAN's express written permission. This warranty becomes null and void if Customer modifies or alters the equipment in any way, other than as specifically authorized by ADTRAN.
EXCEPT FOR THE LIMITED WARRANTY DESCRIBED ABOVE, THE FOREGOING CONSTITUTES THE SOLE AND EXCLUSIVE REMEDY OF THE CUSTOMER AND THE EXCLUSIVE LIABILITY OF ADTRAN AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES (EXPRESSED OR IMPLIED). ADTRAN SPECIFICALLY DISCLAIMS ALL OTHER
6
WARRANTIES, INCLUDING (WITHOUT LIMITATION), ALL WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES, SO THIS EXCLUSION MAY NOT APPLY TO CUSTOMER.
In no event will ADTRAN or its suppliers be liable to the Customer for any incidental, special, punitive, exemplary or consequential damages experienced by either the Customer or a third party (including, but not limited to, loss of data or information, loss of profits, or loss of use). ADTRAN is not liable for damages for any cause whatsoever (whether based in contract, tort, or otherwise) in excess of the amount paid for the item. Some states do not allow the limitation or exclusion of liability for incidental or consequential damages, so the above limitation or exclusion may not apply to the Customer.
7
Customer Service, Product Support Information, and Training
ADTRAN will repair and return this product if within 10 years from the date of shipment the product does not meet its published specification or the product fails while in service.
A return material authorization (RMA) is required prior to returning equipment to ADTRAN. For service, RMA requests, training, or more information, use the contact information given below.
Repair and Return
If you determine that a repair is needed, please contact our Customer and Product Service (CAPS) department to have an RMA number issued. CAPS should also be contacted to obtain information regarding equipment currently in house or possible fees associated with repair.
CAPS Department (256) 963-8722
Identify the RMA number clearly on the package (below address), and return to the following address:
ADTRAN Customer and Product Service 901 Explorer Blvd. (East Tower) Huntsville, Alabama 35806
RMA # _____________
8
Pre-Sales Inquiries and Applications Support
Your reseller should serve as the first point of contact for support. If additional pre-sales support is needed, the ADTRAN Support web site provides a variety of support services such as a searchable knowledge base, latest product documentation, application briefs, case studies, and a link to submit a question to an Applications Engineer. All of this, and more, is available at:
http://support.adtran.com
When needed, further pre-sales assistance is available by calling our Applications Engineering Department.
Applications Engineering (800) 615-1176
Post-Sale Support
Your reseller should serve as the first point of contact for support. If additional support is needed, the ADTRAN Support web site provides a variety of support services such as a searchable knowledge base, updated firmware releases, latest product documentation, service request ticket generation and trouble-shooting tools. All of this, and more, is available at:
http://support.adtran.com
When needed, further post-sales assistance is available by calling our Technical Support Center. Please have your unit serial number available when you call.
Technical Support (888) 4ADTRAN
9
Installation and Maintenance Support
The ADTRAN Custom Extended Services (ACES) program offers multiple types and levels of installation and maintenance services which allow you to choose the kind of assistance you need. This support is available at:
http://www.adtran.com/aces
For questions, call the ACES Help Desk.
ACES Help Desk (888) 874-ACES (2237)
Training
The Enterprise Network (EN) Technical Training Department offers training on our most popular products. These courses include overviews on product features and functions while covering applications of ADTRAN's product lines. ADTRAN provides a variety of training options, including customized training and courses taught at our facilities or at your site. For more information about training, please contact your Territory Manager or the Enterprise Training Coordinator.
Training Phone (800) 615-1176, ext. 7500
Training Fax (256) 963-6700
Training Email training@adtran.com
10

Table of Contents

Chapter 1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Unit Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Front Panel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Figure 1-1. OCU 45 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Rear Panel Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 1-2. OCU 45 Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Chapter 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Unpack and Inspect the Unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Powering the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Table 2-1. DC Connector Symbol Definitions . . . . . . . . . . . . . . . . . . . 18
Figure 2-1. DC Power Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Optical Interface Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
LED and Switch Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 2-2. OCU 45 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Figure 2-3. Electrical Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 2-4. Optical Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Chapter 3 Troubleshooting and Maintenance . . . . . . . . . . . . . . . . 23
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Chapter 4 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Optical Interface - Single-mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Optical Interface - Multi-mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
DS3 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
E3 Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
STS-1 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Agency Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Physical. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
61200664L1-1C OCU 45 User Manual 11
Table of Contents
Appendix A Connector Pin Definitions . . . . . . . . . . . . . . . . . . . . .31
Power Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Alarm Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Figures
Figure 1-1. OCU 45 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Figure 1-2. OCU 45 Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Figure 2-1. DC Power Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Figure 2-2. OCU 45 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Figure 2-3. Electrical Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Figure 2-4. Optical Loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Tables
Table 2-1. DC Connector Symbol Definitions . . . . . . . . . . . . . . . . . . . .18
12 OCU 45 User Manual 61200664L1-1C

Chapter 1 General

UNIT OVERVIEW

The ADTRAN OCU 45 offers transport of DS3/E3/STS-1 services over fiber up to distances of 40 km in the single-mode version and 2 km in the multi-mode version. Measuring only one rack unit high, the OCU 45 can be used stand-alone, wallmounted, or mounted in 19- or 23-inch racks using an optional mounting tray. This compact device gives NSPs a convenient way to extend DS3/E3/STS-1 services from their point of presence to their cus­tomer and provides Enterprise users a powerful tool for extending DS3/E3/ STS-1 services over fiber in a campus environment.
Configuration of the OCU 45 is accomplished through two switches on the front of the unit which configure the metallic interface to DS3, E3, or STS-1 and set the metallic line length to short or long. The OCU 45 has both nor­mally-open and normally-closed alarm relay contacts with a front panel RESET.
Diagnostics include metallic and optical loopbacks, initiated via a front panel switch. Three LEDs are located on the front panel to monitor the sta­tus of both the metallic and optical interfaces.
The OCU 45 is powered from a -48V source. An optional AC to -48 VDC converter is available to allow the unit to be AC powered.
61200664L1-1C OCU 45 User Manual 13
Chapter 1. General

FRONT PANEL FEATURES

The OCU 45 front panel provides switches and LEDs to offer easy configu­ration and troubleshooting (see Figure 1-1). The three switches set the con­figuration for the electrical interface, electrical line length, and loopback test options. The LEDs indicate the status of the power supply, the electrical interface type and line length, loopback diagnostics, and electrical and opti­cal interface status. A brief description of the LEDs is as follows:
•The P
•The
•The L
•The T
•The E
•The O
OWER LED shows that the unit is receiving power.
INTERFACE LED indicates the current electrical interface configura-
tion.
INE LENGTH LEDs indicate the current electrical line length con-
figuration.
EST LEDs indicate that there is an active loopback at the electrical
or optical interface, or that the unit is in normal operation.
LECTRIC LEDs indicate the current status of the electrical inter-
face.
PTICAL LEDs indicate the current status of the optical interface.
Figure 1-1. OCU 45 Front Panel
14 OCU 45 User Manual 61200664L1-1C
Chapter 1. General

REAR PANEL FEATURES

The OCU 45 rear panel provides electrical and optical interface connections, normally-open and normally-closed alarm relay contacts, and a 48V power connection (see Figure 1-2).
The electrical interface connector is provided using dual 75 Ohm BNC female connectors (one for transmit and one for receive). The optical interface of the OCU 45 consists of a standard SC or ST receptacle using two fibers, one for each direction of transmission.
External alarm contacts for critical and non-critical alarms are provided on the rear panel of the OCU 45 using a standard 4-pin terminal block containing nor­mally open, normally closed, common, and ground connections. The DC power supply connector is a standard 3-pin terminal block containing -48V, RETURN, and GROUND. For more information on the above connections, please refer to Installation on page 17.
Figure 1-2. OCU 45 Rear Panel
61200664L1-1C OCU 45 User Manual 15
Chapter 1. General
16 OCU 45 User Manual 61200664L1-1C

Chapter 2 Installation

UNPACK AND INSPECT THE UNIT

Carefully inspect the OCU 45 for any damage that may have occurred in shipment. If damage is suspected, file a claim immediately with the carrier and contact ADTRAN Technical Support (see Customer Service, Product Support Information, and Training on page 8 for contact information). Keep the original shipping container to use for future shipment or verification of damage during shipment.
ADTRAN Shipments Include
The following items are included in ADTRAN shipments of the OCU 45:
•OCU 45 unit
4-position terminal lug connector (alarm)
3-position terminal lug connector (power)
Documentation CD

POWERING THE UNIT

The OCU 45 contains a three-position modular terminal lug connector for supplying DC power to the unit. The modular terminal lug connector allows the user to easily connect and disconnect DC power when replacing rackmount units.
To establish DC power, use 12 to 26 AWG wire to connect the modular connector as follows:
1. Connect the wire lugs on the modular connector which corresponds to the positive (+) and negative (-) terminals on the rear panel to a -48V DC, 0.5A source.
2. Connect the remaining wire lug to the frame ground.
61200664L1-1C OCU 45 User Manual 17
Chapter 2. Installation
3. Once the modular connector is wired, push it firmly into the rear panel power connector.
Use copper conductors only.
Table 2-1 and Figure 2-1 illustrate the DC power connector and give definitions for the three connector symbols.
Table 2-1. DC Connector Symbol Definitions
Symbol Definition
+ Positive side of DC power source (usually ground)
- Negative side of DC power source (usually -48V)
Frame Ground
+
Figure 2-1. DC Power Connector
The following UL requirements must be met during installation of the OCU 45:
1. The unit must be connected to a reliably grounded -48 VDC source which is electrically isolated from the AC source.
2. The branch circuit overcurrent protection should be a fuse or circuit breaker rated -48V, 10A.
3. The unit should be installed in accordance with the requirements of NEC NFPA 70.
4. A readily-accessible disconnect device that is suitably approved and rated should be incorporated in the fixed wiring.
18 OCU 45 User Manual 61200664L1-1C
Chapter 2. Installation

OPTICAL INTERFACE PORT

The OCU 45 optical interface port consists of a single-mode, long-haul or multi-mode, short-haul transceiver module comprised of a transmitter and receiver. The optical interface port supports angled or straight SC or ST type optical connectors and operates in the 1280 nm to 1335 nm wavelength range (1310 nm nominal). The total output power is 8 mW with a 50 mm aperture at 10 cm distance, as defined by IEC. The optical interface uses two fibers, one for each direction of transmission. The long-range optical budget for the optical transceiver (single-mode) is 28 dB, calculated as follows:
Worst case optical transmit power = -5 dBm
Worst case optical receiver sensitivity = -10 dBm to -34 dBm
Calculations:
(34 - 5) dB = 29 dB - 1 dB (optical path penalty) = 28 dB
For the multi-mode optical transceiver, the short-range optical budget is 14 dB and can be calculated using the following equations:
Worst case optical transmit power = -16 dBm
Worst case optical receiver sensitivity = -14 dBm to -31 dBm
Calculations:
(31 - 16) dB = 15 dB - 1 dB (optical path penalty) = 14 dB
The optical interface complies with IEC Class 1 laser safety requirements (under normal operating conditions). The OCU 45 contains an integrated automatic shutdown circuit that disables the laser when it detects transmitter failures giving it an FDA Class 1 laser safety rating. The FITS rating of the internal shutdown circuit is less than 500 FITS.
A removable process plug to cover the optical interface is provided with the OCU 45 unit.
61200664L1-1C OCU 45 User Manual 19
Chapter 2. Installation

LED AND SWITCH DESCRIPTIONS

The OCU 45 has switches to configure the desired electrical interface, electrical line length, and loopback tests. The LEDs indicate the status of the power supply, the electrical interface line type and length, loopback diagnostics, and electrical and optical interface status. A full description of the switches and LEDs follows Figure 2-2.
Figure 2-2. OCU 45 Front Panel
Power Supply
The
POWER LED is active when the unit is on and receiving full power.
Interface Switch and LEDs
The
INTERFACE LEDs reflect the electrical interface switch setting. The
OCU 45 supports DS3, E3, and STS-1 operation.
Line Length Switch and LEDs
The
LINE LENGTH LEDs reflect the electrical line length switch setting.
The line length is the length of coaxial cable between the OCU 45 and the DS3/E3/STS-1 equipment, and is set as follows:
DS3 / STS-1 E3
0 - 225 feet
226 - 450 feet
20 OCU 45 User Manual 61200664L1-1C
SHORT
LONG
N/A
N/A
Chapter 2. Installation
Test Switch and LEDs
The
TEST LEDs reflect the loopback diagnostic switch setting. Two diagnostic
loopbacks are provided: electrical and optical loopback tests. Set to NORM for no loopback testing
Figure 2-3. Electrical Loopback
Figure 2-4. Optical Loopback
61200664L1-1C OCU 45 User Manual 21
Chapter 2. Installation
22 OCU 45 User Manual 61200664L1-1C
Chapter 3 Troubleshooting and
Maintenance
Troubleshooting guidelines and maintenance information are provided in this chapter.

TROUBLESHOOTING

Power
Condition: POWER LED is not illuminated.
If locally powered, verify the power cable installation.
Electric LOS
Condition: ELECTRIC LOS LED is illuminated.
1. Verify that the cable from the network demarcation is connected to the dual BNC connectors (labeled the OCU 45.
2. If all connections seem intact, check the DS3/STS-1 device on the other end of the circuit.
ELECTRICAL) located on the back panel of
Electric Alarm
Condition: ELECTRIC ALARM LED is illuminated.
1. Line coding violations (LCVs) are being received on the electrical interface. Check the electrical interface configuration, and verify the current setting is correct.
2. If the current electrical interface configuration setting is correct, check the DS3/STS-1 device connected to the OCU 45.
61200664L1-1C OCU 45 User Manual 23
Chapter 3. Troubleshooting and Maintenance
3. Alternately, an electric alarm could mean that all 1s are being received on the electrical interface, indicating an AIS alarm being transmitted from the DS3/STS-1 device.
Optical LOS
Condition: OPTICAL LOS LED is illuminated.
1. Verify that the fiber is fully seated in the optical connector interface of the OCU 45 unit.
Optical Alarm
Condition: OPTICAL ALARM LED is illuminated.
1. Line coding violations are being received from the far end OCU 45.
2. Alternately, an optical alarm can indicate that all 1s are being received on the optical interface from the far end device.
3. Verify that the far end OCU 45 is functioning properly.
Alarm Relay Conditions
Condition: ALARM RELAYS are indicating an active alarm.
1. The unit is currently experiencing an signal.
2. The electrical interface is currently not transmitting data.
3. The electrical interface setting is not configured properly (i.e., the interface setting and the data being received are different data rates).
24 OCU 45 User Manual 61200664L1-1C
OPTICAL or ELECTRICAL loss of
Chapter 3. Troubleshooting and Maintenance
Power On - Self Check Failure
Condition: Only the POWER LED is illuminated.
The unit has failed its internal self check. Return the unit to the ADTRAN Customer and Product Service (CAPS) Department as instructed in Customer Service, Product Support Information, and Training on page 8.

MAINTENANCE

The OCU 45 requires no routine maintenance. No repairs should be performed by the customer. Repair services can be obtained by returning the unit to the ADTRAN Customer and Product Service (CAPS) department as instructed in Customer Service, Product Support Information, and Training on page 8.
61200664L1-1C OCU 45 User Manual 25
Chapter 3. Troubleshooting and Maintenance
26 OCU 45 User Manual 61200664L1-1C

Chapter 4 Specifications

OPTICAL INTERFACE - SINGLE-MODE

Connector Standard SC receptacle using two fibers
(one for each direction of transmission)
Tra nsmitt er Class 1 Laser
Operating Wavelength
Cable Type 9/125 µm single-mode
Transmission Code Manchester
Distance Up to 40 km
Transmitter Output -5 dBm
Receiver Sensitivity -10 dBm to -34 dBm
The single-mode optical interface complies with IEC 60825-1 and FDA 21CFR 1040.10 and 1040.11.
1310 nm
61200664L1-1C OCU 45 User Manual 27
Chapter 4. Specifications

OPTICAL INTERFACE - MULTI-MODE

Connector Standard ST receptacle using two fibers
(one for each direction of transmission)
Transmitter ELED
Operating Wavelength
Cable Type 62.5/125 µm multi-mode
Transmission Code Manchester
Distance Up to 2 km
Transmitter Output -16 dBm
Receiver Sensitivity -14 dBm to -31 dBm
The single-mode optical interface complies with IEC 60825-1 and FDA 21CFR 1040.10 and 1040.11.
1310 nm

DS3 INTERFACE

Line Interface Dual 75 Ohm BNC female connectors
Line Rate 44.736 Mbps
Line Code B3ZS
Framing Format M13 and C-Bit Parity
Line Buildout 0 to 225 feet (short)
226 to 450 feet (long)
28 OCU 45 User Manual 61200664L1-1C
Chapter 4. Specifications

E3 INTERFACE

Line Interface Dual 75 Ohm BNC female connectors
Line Rate 34.368 Mbps
Line Code HDB3

STS-1 INTERFACE

Line Interface Dual 75 Ohm BNC female connectors
Line Rate 51.84 Mbps
Line Code B3ZS
Framing Format STS-1
Line Buildout 0 to 225 feet (short)
226 to 450 feet (long)

CONFIGURATION

Metallic Interface DS3, E3, STS-1
Metallic Line Buildout
Short, Long

DIAGNOSTICS

Built-in selftest
Metallic loopback
Optical loopback
61200664L1-1C OCU 45 User Manual 29
Chapter 4. Specifications

ALARMS

External alarm contacts for critical and non-critical alarms
Normally open and normally closed pinouts
Front panel Reset switch

AGENCY APPROVALS

Emissions Part 15, Class A
Bellcore NEBS, Level 3
Safety UL 1950, CUL

ENVIRONMENT

Operating 0°C to 50°C (32°F to 122°F)
Storage -20°C to 70° C (-4°F to 158°F)
Relative Humidity Up to 95 percent, non-condensing

PHYSICAL

Dimensions 1.7 inches H x 6.7 inches W x 9.1 inches D
Weight 2.0 pounds
Power -48 VDC, 5 Watts
30 OCU 45 User Manual 61200664L1-1C

Appendix A Connector Pin Definitions

POWER CONNECTOR

Pin Description
1 - 48 RTN
2- 48
3 Chassis Ground

ALARM RELAY

Pin Description
1 Normally Closed
2 Normally Open
3 Common
4Ground
61200664L1-1C OCU 45 User Manual 31
Appendix A. Connector Pin Definitions
32 OCU 45 User Manual 61200664L1-1C

Index

A
Alarm relay conditions, problems 24 Alarm relay connector, pinout 31
C
Connector, DC Power Supply 15, 18 Connector, electrical interface Connector, optical interface 15
15
D
DC Power Supply connector 15, 18 DC Power Supply, Connecting DS3 Interface, Specifications 28
17
E
E3 Interface, Specifications 29 Electric alarm, problems Electric LED 14 Electric LOS, problems 23 Electrical interface connector Environmental specifications 30 External alarm contacts 15
23
15
F
Front Panel 14
I
Installation 17 Interface LED 14
L
LED, Electric 14 LED, Interface 14 LED, Line Length 14 LED, Optical LED, Power 14 Line Length LED 14 Line, 4-wire
14
29
M
Maintenance 25
O
Optical alarm, problems 24 Optical interface connector 15 Optical Interface, Multimode Optical Interface, Singlemode 27 Optical interface, specifications 27 Optical LED Optical LOS, problems 24
14
28
P
Power Connector, pinout 31 Power LED Power On - Self Check Failure 25 Power, problems 23 Powering the Unit
14
17
R
Rear Panel 15
S
Shipping contents 17 Specifications Specifications, Agency Approvals 30 Specifications, Alarms 30 Specifications, Configuration Specifications, Diagnostics 29 Specifications, DS3 interface 28 Specifications, E3 interface Specifications, Optical interface 27 Specifications, STS-1 interface 29 STS-1 Interface, Specifications
27
29
29
29
T
Test LED 14 Troubleshooting 23
61200664L1-1C OCU 45 User Manual 33
Index
U
UL requirements 18 Unit overview 13
61200664L1-1C OCU 45 User Manual 34