ADTRAN NxT1 HSSI-V.35 User Manual

For more detailed documentation, visit us online at www.adtran.com
NxT1 HSSI/V-35 MODULE P/N 1200346L2
HSSI/V.35
Nx T1 HSSI/V.35
NSTALLATION INSTRUCTIONS
I
T1-1 T1-3T1-2 T1-4
500 Series
1. Remove the cover plate from the appropriate option slot in the ATLAS 550 Base Unit.
2. Slide the Nx T1 HSSI/V-35 Module into the option slot until the module is firmly positioned against the front of the chassis.
3. Secure the thumbscrews at both edges of the module. Tighten with a screwdriver.
4. Connect the cables to the associated device(s).
5. Complete installation of remaining modules and Base Unit as specified in the Installation chapter of the ATLAS 550 System Manual.
PECIFICATIONS
S
HSSI Rate: Up to 11.04 Mbps
V.35 R a te: Up to 5.52 Mbps
T1 Links: HSSI Interface – 1 to 8 Total T1 Links (up to 4 from module T1
interfaces and up to 4 from other T1 modules)
V.35 Interface – 1 to 4 Total T1 Links (in any combination of module T1 interfaces and other T1 modules)
T1 Line Rate: 1.544 Mbps ± 75 bps
T1 Line Framing: D4 or ESF per ANSI t1.403 and AT&T TR 54016
T1 Testing: Line or payload loopback (Local and Remote)
Environmental: Operating Temperature: 0ºC to 50ºC
Storage Temperature: -40ºC to 70ºC
Relative Humidity: 95% non-condensing
Connectors: T1 Interfaces: RJ-48C
HSSI Interface: 50 pin SCSI-II Female
HSSI/V.35 (SCSI-50) P
PIN# (+ side) PIN# (- side) Direction Description
1 26 HSSI SG - Signal Ground 2 27 O HSSI RT - Receive Timing 3 28 O HSSI CA - DCE Available 4 29 O HSSI RD - Receive Data 5 30 O HSSI LC - Loopback Circuit C 6 31 O HSSI ST - Send Timing 7 32 HSSI SG - Signal Ground 8 33 I HSSI TA - DTE Available
9 34 I HSSI TT - Terminal Timing 10 35 I HSSI LA - Loopback Circuit A 11 36 I HSSI SD - Send Data 12 37 I HSSI LB - Loopback Circuit B 13 38 HSSI SG - Signal Ground — 39 Ancillary to DCE (Reserved) 14 I V.35 RTS - Request to Send 15 40 I V.35 TT Terminal Timing 16 41 I V.35 SD Send Data — 42 O V.35 DCD - Data Carrier Detect
17-18 43 Ancillary to DCE (Reserved)
19 44 HSSI SG - Signal Ground 20 45 O V.35 ST - Send Timing 21 46 O V.35 RT - Receive Timing 22 47 O V.35 RD - Receive Data 23 O V.35 CTS - Clear to Send — 48 I V.35 Ground/Present 24 49 O HSSI TM - Test Mode 25 50 HSSI SG - Signal Ground
T1 N
ETWORK CONNECTION PINOUT
Pin Name Description
1 R1 RXDATA Receive data from the network ring 2 T1 RXDATA Receive data from the network tip 3, 6, 7, 8 Unused n/a 4 R TXDATA Send data towards the network ring 5 T TXDATA Send data towards the network tip
INOUT
Quick Start Guide, 61200346L2-13A, February 2002 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright 2002 ADTRAN, All Rights Reserved
NxT1 HSSI/V-35 MODULE P/N 1200346L2
ENU TREE
M
Part Number Prt
Serial Number CLR
Info Assembly Revision ES
Firmware Revision LOS BES
Slt NxT1 HSSI Menus Prt RED SES
Type Alarm Status Alarms YELLOW SEFS
Menu Rx Level BLUE LOFC
Modules Alarm Performance Curr, DS0 Alarm CSS
Test T1 Menus 15Min, and 24Hr UAS
State LCV
Rev Prt PCV
Config Port Name LES
Module Alarms Frame
Code
Tes t Pr t T x Ye l
Loc LB LBO
IMUX Menus Config Prt
Grp Assoc
Scramble
Loopback
Status LA
HSSI Menus LB
Config Tx Clk TA
CA Rx Rate
LC Tx Rate
Quick Start Guide, 61200346L2-13A, February 2002 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright 2002 ADTRAN, All Rights Reserved
Loading...