Adam Equipment NBL 6201e, NBL 8201e, NBL 16001e, NBL 12001e, NBL 22001e Operating Manual

...
© Adam Equipment Company 2015
Adam Equipment
Nimbus NBL Series
Operating Manual
For internal (‘i’) and external (‘e’) calibration models
(P.N. 3016612481, Revision 2.00, Effective Jul 2015)
Software rev.: V3.1145 & above (Force Motor Analytical Models)
EN
© Adam Equipment Company 2015 1 3016612481Rev2.00-Jul15
TABLE OF CONTENTS
1 KNOW YOUR BALANCE ........................................................................................................ 2
2 PRODUCT OVERVIEW .......................................................................................................... 3
3 PRODUCT SPECIFICATIONS ................................................................................................ 4
4 UNPACKING THE BALANCE ............................................................................................... 10
5 LOCATING THE BALANCE .................................................................................................. 10
6 SETTING UP THE BALANCE ............................................................................................... 11
6.1 ASSEMBLING THE BALANCE ...................................................................................... 11
6.1.1 Levelling the balance ............................................................................................... 11
6.1.2 Warm-Up Time ........................................................................................................ 11
6.1.3 Weighing.................................................................................................................. 11
6.2 CALIBRATION .............................................................................................................. 12
6.2.1 Manual Calibration ................................................................................................... 12
6.2.2 Calibration using Internal Calibration mass (if fitted) ................................................ 12
6.2.3 Calibration using External Calibration mass ............................................................. 12
6.2.4 Automatic Calibration ............................................................................................... 12
6.2.5 Calibration Errors ..................................................................................................... 13
7 DISPLAY ............................................................................................................................... 14
7.1 SYMBOLS AND TEXT................................................................................................... 14
8 KEYPAD ............................................................................................................................... 15
8.1 NUMERIC ENTRY METHOD ........................................................................................ 16
9 INPUT/OUTPUT .................................................................................................................... 17
10 OPERATIONS .................................................................................................................... 18
10.1 INITIALISATION ............................................................................................................ 18
10.2 PASSCODES ................................................................................................................ 18
10.3 WEIGHING .................................................................................................................... 19
10.4 FUNCTIONS ................................................................................................................. 20
10.4.1 Parts Counting ..................................................................................................... 21
10.4.2 Percentage Weighing ........................................................................................... 22
10.4.3 Dynamic (Animal) Weighing ................................................................................. 23
10.4.4 Density Determination .......................................................................................... 25
11 RS-232 INTERFACE .......................................................................................................... 27
11.1 HARDWARE ................................................................................................................. 27
11.2 OUTPUT FORMATS ..................................................................................................... 27
11.2.1 SINGLE-LINE OUTPUT FORMAT ....................................................................... 27
11.2.2 STANDARD OUTPUT FORMAT .......................................................................... 28
11.2.3 CUSTOM OUTPUT FORMAT .............................................................................. 28
11.3 INPUT COMMANDS USING REMOTE KEYS ............................................................... 29
11.3.1 Invalid Input Command: ....................................................................................... 29
12 ERROR CHECKING .......................................................................................................... 31
13 SUPERVISOR MENUS ...................................................................................................... 32
13.1 ENABLE WEIGHING UNITS ......................................................................................... 32
13.2 ENABLE WEIGHING MODES ....................................................................................... 32
13.3 ENABLE SERIAL INTERFACE PARAMETERS ............................................................ 32
13.4 FORMAT OF CUSTOM FORMS #1 and #2 ................................................................... 33
13.5 SETUP PARAMETERS ................................................................................................. 34
13.6 CALIBRATION SETUP .................................................................................................. 35
13.7 PASSCODES ................................................................................................................ 35
14 ACCESSORIES & SPARE PARTS .................................................................................... 37
15 SAFETY AND MAINTENANCE .......................................................................................... 39
16 TROUBLE-SHOOTING ...................................................................................................... 40
16.1 TROUBLE-SHOOTING GUIDE. .................................................................................... 41
17 SERVICE INFORMATION .................................................................................................. 43
18 BALANCE MENU STRUCTURE ........................................................................................ 44
19 LANGUAGE TABLE ........................................................................................................... 47
20 WARRANTY INFORMATION ............................................................................................. 48
EN
© Adam Equipment Company 2015 2 3016612481Rev2.00-Jul15
1 KNOW YOUR BALANCE
T
hank you for selecting the Nimbus Balance from Adam Equipment.
This Instruction Manual will familiarise you with the installation, use, general maintenance etc. of the balance, and will guide you through the various applications. It also covers accessories, trouble-shooting, after sales service information, and other important information.
These balances are highly accurate precision instruments and contain sensitive mechanisms and components. They should be transported and handled with care. When in operation, be careful to place loads gently on the weighing surface and do not overload or exceed recommended maximum capacity of the instrument or damage may occur.
Please read this Manual thoroughly before starting operation. If you need any clarifications, feel free to contact your supplier or Adam Equipment.
EN
© Adam Equipment Company 2015 3 3016612481Rev2.00-Jul15
2 PRODUCT OVERVIEW
T
he Nimbus balances are ideal for laboratory and general purpose weighing. They can
also be used for some advanced weighing functions.
FEATURES:
External menu-driven calibration allowing user-selectable range of calibration weights.
Internal calibration (option) for outstanding accuracy without the need for manual calibration.
Mains powered, with some models offering rechargeable battery pack option for cordless use.
Solid die-cast aluminium alloy construction with 304 grade stainless steel pan for durability and
easy cleaning.
Large easy to read LCD display with backlight.
Standard applications include weighing, percentage weighing, parts counting, dynamic (animal)
weighing (not ‘j’ models), and solid and liquid density determination.
Bi-directional RS-232 interface and USB interface as standard.
External display option
Can be configured to print a GLP Compliant report after each calibration to include the time, date,
balance number and a verification of the calibration.
Force-restoration mechanism for supreme accuracy, or alloy load cell technology for stable yet accurate weighing.
Automatic temperature compensation.
Multiple weighing units.
Easy to use, wipe-clean sealed membrane keypad.
Below balance weighing facility (accessory hook required).
Display in a choice of 4 languages – English, German, French & Spanish.
Password protection.
Security locking point.
EN
© Adam Equipment Company 2015 4 3016612481Rev2.00-Jul15
3 PRODUCT SPECIFICATIONS
Nimbus NBL Models
(
Suffix e for external calibration models, Suffix i for internal calibration models)
Model # NBL 84 e/i NBL 124 e/i NBL 164 e/i NBL 214 e/i NBL 254 e/i NBL 214j e/i
Maximum Capacity
80 g 120 g 160 g 210 g 250 g 210 g
Readability (d) 0.0001 g 0.0002 g Number of
intervals n=
800000 1200000 1600000 2100000 2500000 2100000
Min. weight 0.01 g 0.02 g Repeatability
(Std. Dev)
0.00015 g 0.0002 g 0.0004 g
Linearity + 0.0002 g 0.0004 g
Units of Measure
grams, milligrams, carats, grains, Newtons, ounces, troy ounces,
pennyweight, custom
grams,
milligrams,
carats, Stabilization Time
Typically 3 seconds Operating Temp 15ºC to 35ºC recommended, 40 – 60 % RH (non-condensing) Power Supply
External mains power adapter - supplied as standard
(Input Voltage 100–240 VAC, 50/60 Hz) Input Voltage 18 VDC - 830 mA Weighing
mechanism
Force Restoration Balance Motor Calibration Suffix i = internal calibration mechanism, e = external calibration only External
Calibration Mass
Recommended OIML class: E2, ASTM / ANSI class: 1
50 g 100 g 100 g
Display LCD with blue backlight, 7 characters, 20 mm high, and symbols Draft Shield
(w x d x h)
Sliding door Draft Shield (165 x 145 x 240 mm)
Pan Size Round, 90mm diameter Overall
Dimensions (w x d x h)
220 x 310 x 323 mm
8.7 x 12.2 x 12.7 in
Net Weight
5.2 kg / 11 lb 9 oz (external calibration model)
5.9 kg / 13 lb 0 oz (internal calibration model)
EN
© Adam Equipment Company 2015 5 3016612481Rev2.00-Jul15
Model # N
BL 223 e / i NBL 423 e / i
Maximum Capacity 220 g 420 g Readability (d) 0.001 g
Number of intervals n=
220000 420000
Min. 0.02 g 0.02 g Repeatability
(Std. Dev)
0.002 g
Linearity + 0.002 g Units of Measure
grams, milligrams, carats, grains, Newtons, ounces, troy ounces, pennyweight, custom
Stabilization Time Typically 3 seconds Operating Temp 15ºC to 35ºC recommended, 40 – 60 % RH (non-condensing)
Power Supply
External mains power adapter - supplied as standard
(Input Voltage 100–240 VAC, 50/60 Hz)
Factory-fit NiMH battery pack option.
Input Voltage 18 VDC - 830 mA Weighing
mechanism
Precision Load Cell Calibration Suffix i = internal calibration mechanism, e = external calibration only, External Calibration
Mass
Recommended OIML class: E2, ASTM / ANSI class: 2
100 g 200 g
Display LCD with blue backlight, 7 characters, 20 mm high, and symbols Draft Shield
(w x d x h)
Glass Ring Draft Shield With Alloy Lid (180 mm diam. x 90 mm)
Pan Size Round, 120 mm diameter Overall Dimensions
(w x d x h)
220 x 310 x 90 mm without breeze ring
8.7 x 12.2 x 3.5 in
Net Weight
3.1 kg / 6 lb 12 oz (external calibration model)
3.7 kg / 8 lb 8 oz (internal calibration model)
EN
© Adam Equipment Company 2015 6 3016612481Rev2.00-Jul15
Model # N
BL 623 e / i NBL 823 e / i
Maximum Capacity 620 g 820 g Readability (d) 0.001 g
Number of intervals n=
620000 820000
Min. weight 0.02 g 0.02 g Repeatability
(Std. Dev)
0.002 g
Linearity + 0.002 g Units of Measure
grams, milligrams, carats, grains, Newtons, ounces, troy ounces, pennyweight, custom
Stabilization Time Typically 3 seconds Operating Temp 15ºC to 35ºC recommended, 40 – 60 % RH (non-condensing)
Power Supply
External mains power adapter - supplied as standard
(Input Voltage 100–240 VAC, 50/60 Hz) Input Voltage 18 VDC - 830 mA Weighing
mechanism
Force Restoration Balance Motor Calibration Suffix i = internal calibration mechanism, e = external calibration only External Calibration
Mass
Recommended OIML class: E2, ASTM / ANSI class: 2
500 g
Display LCD with blue backlight, 7 characters, 20 mm high, and symbols Draft Shield
(w x d x h)
Glass Ring Draft Shield With Alloy Lid (180 mm diam. x 90 mm)
Pan Size Round, 160 mm diameter Overall Dimensions
(w x d x h)
220 x 310 x 90 mm without breeze ring
8.7 x 12.2 x 3.5 in
Net Weight
4.0 kg / 8 lb 13 oz (external calibration model)
4.8 kg / 10 lb 9 oz (internal calibration model)
EN
© Adam Equipment Company 2015 7 3016612481Rev2.00-Jul15
Model # N
BL 1602 e / i NBL 2602 e / i NBL 3602 e / i NBL 4602 e / i
Maximum Capacity
1600 g 2600 g 3600 g 4600 g
Readability (d) 0.01 g 0.01 g 0.01 g 0.01 g Number of
intervals n=
160000 260000 360000 460000
Min. weight 0.2 g 0.2 g 0.2 g 0.2 g Repeatability
(Std. Dev)
0.02 g Linearity + 0.02 g Units of Measure
grams, carats, grains, Newtons, ounces, troy ounces,
pennyweight, pounds, kilograms, custom
Stabilization Time Typically 3 seconds Operating Temp 15ºC to 35ºC recommended, 40 – 60 % RH (non-condensing)
Power Supply
External mains power adapter - supplied as standard
(Input Voltage 100–240 VAC, 50/60 Hz)
Factory-fit NiMH battery pack option. Input Voltage 18 VDC - 830 mA Weighing
mechanism
Precision Load Cell Calibration Suffix i = internal calibration mechanism, e = external calibration only External
Calibration Mass
Recommended OIML class: F1, ASTM / ANSI class: 3
1 kg 2 kg 2 kg 2 kg
Display LCD with blue backlight, 7 characters, 20 mm high, and symbols Draft Shield
(w x d x h)
None
Pan Size Round, 160 mm diameter Overall
Dimensions (w x d x h)
220 x 310 x 90 mm
8.7 x 12.2 x 3.5 in
Net Weight
3.1 kg / 6 lb 14 oz (external calibration model)
3.9 kg / 8 lb 10 oz (internal calibration model)
EN
© Adam Equipment Company 2015 8 3016612481Rev2.00-Jul15
Model # N
BL 4201e NBL 6201e NBL 8201e
Maximum Capacity
4200g 6200g 8200g
Readability (d) 0.1g 0.1g 0.1g Number of
intervals n=
42000 62000 82000
Min. weight 2 g 2 g 2 g Repeatability
(Std. Dev)
0.1g Linearity + 0.1g Units of Measure
grams, carats, grains, Newtons, ounces, troy ounces,
pennyweight, pounds, kilograms, custom
Stabilization Time Typically 3 seconds Operating Temp 15ºC to 35ºC recommended, 40 – 60 % RH (non-condensing)
Power Supply
External mains power adapter - supplied as standard
(Input Voltage 100–240 VAC, 50/60 Hz)
Factory-fit NiMH battery pack option. Input Voltage 18 VDC - 830 mA Weighing
mechanism
Precision Load Cell Calibration External calibration only External
Calibration Mass
Recommended OIML class: F2, ASTM / ANSI class: 4
2 kg 2 kg
Display LCD with blue backlight, 7 characters, 20 mm high, and symbols Draft Shield
(w x d x h)
None
Pan Size Round, 160 mm diameter Overall
Dimensions (w x d x h)
220 x 310 x 90 mm
8.7 x 12.2 x 3.5 in
Net Weight 3.1 kg / 6 lb 14 oz
EN
© Adam Equipment Company 2015 9 3016612481Rev2.00-Jul15
Model # NBL 12001e NBL 16001e NBL 22001e
Maximum Capacity
12000g 16000g 22000g
Readability (d) 0.1g 0.1g 0.1g Number of
intervals n=
120000 160000 220000
Min. weight 2 g 2 g 2 g Repeatability
(Std. Dev)
0.1g Linearity + 0.1g Units of Measure
grams, carats, grains, Newtons, ounces, troy ounces,
pennyweight, pounds, kilograms, custom
Stabilization Time Typically 3 seconds Operating Temp 15ºC to 35ºC recommended, 40 – 60 % RH (non-condensing)
Power Supply
External mains power adapter - supplied as standard
(Input Voltage 100–240 VAC, 50/60 Hz)
Factory-fit NiMH battery pack option. Input Voltage 18 VDC - 830 mA Weighing
mechanism
Precision Load Cell Calibration External calibration only External
Calibration Mass
Recommended OIML class: F2, ASTM / ANSI class: 4
5 kg 10 kg 10 kg
Display LCD with blue backlight, 7 characters, 20 mm high, and symbols Draft Shield
(w x d x h)
None
Pan Size 390 X 290 mm Overall
Dimensions (w x d x h)
390 x 480 x 100 mm (590 mm tall with pole accessory)
8.7 x 12.2 x 3.5 in
Net Weight 7.6 kg / 16 lb 12 oz
EN
© Adam Equipment Company 2015 10 3016612481Rev2.00-Jul15
4 UNP
ACKING THE BALANCE
Remove the balance from the packing by carefully lifting it out of the box. Inside the box you will find everything needed to start using the balance-
AC mains power adapter & cord
Stainless Steel Top Pan
Alloy sub-pan
Draught shield (for mg models only)
User documentation
Carefully follow the quick setup guide included to assemble the balance.
5 L
OCATING THE BALANCE
The balance should not be placed in a location that will reduce the accuracy.
Avoid extremes of temperature. Do not place in direct sunlight or near air conditioning vents.
Avoid unsuitable tables. The table or floor must be rigid and not vibrate.
Avoid unstable power sources. Do not use near large users of electricity such as welding equipment or large motors.
Do not place near vibrating machinery. Avoid high humidity that might cause condensation.
Avoid direct contact with water. Do not spray or immerse the balances in water.
Avoid air movement such as from fans or opening doors. Do not place near open windows or air-conditioning vents.
Keep the balance clean. Do not stack material on the balances when they are not in use.
Avoid sources of static electricity. This can affect measurement accuracy and may damage sensitive electronics.
EN
© Adam Equipment Company 2015 11 3016612481Rev2.00-Jul15
6 S
ETTING UP THE BALANCE
6.1 ASSEMBLING THE BALANCE
Carefully follow the included quick setup guide to assemble the balance. Ensure that you locate the balance on a solid level surface, free from vibration.
6.1.1 Levelling the balance
After placing the balance in a suitable location, level it by using the spirit level on the front of the balance. To level the balance turn the two adjustable feet at the rear of the balance until the bubble in the spirit level is centred.
6.1.2 Warm-Up Time
Before you start weighing, you should allow the balance to achieve a stable internal t
emperature. For accurate weighing to the manufacturer’s specification it is important to power on the balance and allow to warm up for at least 6 hours for load cell mechanisms, and 12 hours for force motor mechanisms.
6.1.3 Weighing
I
nsert the power supply cable DC connector to the connector on the rear of the balance. Plug the power supply module into the mains and press the power switch on the keypad to turn on the balance. The display will indicate the balance serial number followed by the software revision number, followed by the maximum capacity of the balance. Next the balance will run a self­test by displaying all segments followed by a busy symbol and a line of 7 dashes indicating the balance is in busy mode. Once ready, the display will show a zero weight reading, accompanied by the 0 symbol.
On
ce a suitable warm-up period is complete and you are ready to start weighing, place an item to be weighed on the balance. A stable symbol is shown when the balance is in stable condition. It will turn off if the balance is not stable. Exact zero is shown when the “0“ symbol is visible on the top left of the display area.
EN
© Adam Equipment Company 2015 12 3016612481Rev2.00-Jul15
6.2 CALIBRATION
Units with an ‘i’ suffix can be calibrated using either internal calibration mechanism or by u
sing an external mass. Units with an ‘e’ suffix can only be calibrated with an external mass. Internal calibration option must be enabled in the setup menu options or else external calibration mode will be used when the [Cal] key is pressed.
6.2.1 Manual Calibration
Pressing the [Cal] key will start calibration. Calibration can also be initiated by a change in internal temperature or a set time period as determined by the user.
Pressing [0
/T] will abort the calibration at any time.
Calibration should be performed carefully and in conditions of no vibration, air movement or other disturbance. Make sure the pan is empty, clean, and correctly fitted.
6.2.2 Calibration using Internal Calibration mass (if fitted)
Note: Internal calibration (if fitted) will only initiate if it is enabled as the default calibration method in the Supervisor level calibration setup menu.
On pressing the [Cal] key the display will show the busy symbol and a line of 7 dashes and then after a few seconds will display ‘CALIBRA
CALIBRACALIBRA
CALIBRA’. Then the busy symbol and a line of 7
dashes will reappear, followed by ‘CAL On
CAL OnCAL On
CAL On’. Then ‘CALIbrA
CALIbrACALIbrA
CALIbrA’ will appear again, followed by
the busy symbol and a line of dashes. Finally ‘CAL OFF
CAL OFFCAL OFF
CAL OFF’ will be displayed, followed by a
beep and the busy symbol and a line of dashes. A final beep will sound the end of calibration and the display should return to ‘0
00
0.000
000000
000 g’ or similar. Internal calibration is now
complete and normal operations may proceed.
6.2.3 Calibration using External Calibration mass
Note: Calibration mass used should be a known accurate item, ideally with an OIML o
r ASTM/ANSI classification appropriate to the accuracy of the balance.
On pressing the [Cal] key the display will show the balance setting a new Zero condition by showing “LOAD 0
LOAD 0LOAD 0
LOAD 0”. Make sure the pan is empty then press the [Setup] key to continue
The display will show the busy symbol and a line of dashes and then after a few seconds will display the required calibration mass. For example, for a 213e model the display will
be “LOAd 100
LOAd 100LOAd 100
LOAd 100 g” where 100 g is the required calibration mass.
Place the selected mass on the balance. The balance will automatically continue. The display will show the busy symbol and a line of dashes and after calibration is complete it
will sound a beep and display “vNLOAD
vNLOADvNLOAD
vNLOAD”. Remove the weight. Another beep will be heard
confirming the unloading action. The balance will display the busy symbol and a line of dashes for a few seconds and then sound a beep and return to normal weighing.
6.2.4 Automatic Calibration
The balance will indicate the need for calibration when the balance has automatic ca
libration enabled and the set pre-conditions for automatic calibration have been met.
Conditions that will trigger an automatic calibration are:
EN
© Adam Equipment Company 2015 13 3016612481Rev2.00-Jul15
Internal temperature change greater than a pre-set amount (typically 2ºC for P
recision balances).
Time since last calibration exceeds a pre-set time (typically 4 hours, or 15 minutes after power is applied).
The balance will indicate the need for calibration to be carried out by flashing the “
CAL
symbol on the display. As soon as the balance is calibrated the symbol will be turned off. The Auto calibration feature can be enabled, disabled or changed within the user options
to meet the requirements of the users.
6.2.5 Calibration Errors
Occasionally during calibration an error will be detected. These errors can be caused by:
Unstable readings
Improper calibration weights being used
Large shifts of zero from the factory settings
When an error is found a displayed message will be shown and the calibration must be done again. If the balance has error messages more than once it is possible the mechanics have been damaged.
EN
© Adam Equipment Company 2015 14 3016612481Rev2.00-Jul15
7 DI
SPLAY
The LCD has several areas­A large 7 digit area to display the weight with symbols for common weighing units on its
right and symbols for zero, tare (Net) and stability on the left. Text symbols above the display show the current operation or function being used.
7.1 SYMBOLS AND TEXT
The LCD has unique symbols to indicate the following:
0
Ze
ro
Busy Stable
g,
mg, kg,
ct,
dwt, GN, ozt,
oz,
N, Custom, g/cc, Pcs, %,
Symbols shown for units and modes Battery charge symbol
Indicators:
“CAL”
When calibration is occurring or about to occur
“T”
For a time driven calibration
“ºC”
When a temperature is shown or a temperature driven calibration is to occur
“Net”
When a net weight is shown
Dynamic
When the balance is in the animal weighing mode
Hold
When the balance is in hold mode
“Parts
When the balance is in the Parts counting mode
“Percent
When the balance is in the Percent weighing mode
“Density S
olid
When the balance is in the Solid Density mode
“Density L
iquid
When the balance is in the Liquid Density mode
EN
© Adam Equipment Company 2015 15 3016612481Rev2.00-Jul15
8 KE
YPAD
The keypad has the following keys to operate the balance.
Keys
Primary function
[POWER] To turn the balance to ON or Standby
[0/T]
[0/T] A combined zero and tare function. To escape from setup functions and modes.
[Cal]
[Cal] Starts the calibration function
[Print] [Print] Instructs the balance to print data
[Mode] [Mode] Enters the Mode Selection Menu
[Unit]
[Unit] Selects weighing units by cycling through a set of
enabled units.
[Setup]
[Setup
]
Enters the setup parameters (Supervisor Menus). Enters a function or saves a value while manually entering unit weight or check weighing limits.