A&D SF-SG User Manual 2

S
S
F
F//
S
S
G
G
S
S
e
errii
e
e
s
s
PPrriiccee CCoommppuuttiinngg SSccaallees
s
Instruction Manual
137-1A-IE
SF/SG Series Instruction Manual
Index
Item Number Description Page
Unpacking and Inspecting 2
Specifications 3
Main Operating Components 4
1 Zero Point Adjustment 5
2 Tare Adjustment 5
3 Keypad Tare Entry 6
4 Setting Unit Price 7
5 Storing a Unit Price in Memory 8
6 Recalling a Unit Price from Memory 8
7 Totaling Multiple Items with Unit Prices Stored in PLU Memory 8
8 Clearing Totaling Memory 8
9 Multiplier Function 9
10 Calculating Correct Change for the Customer 10
11 Clear Entry Function 10
12 Automatic Cancellation of Unit Price 11
13 Setting “F” Functions 11
1
Thank You...
Thank you for purchasing our A&D SF/SG Series price computing scale. Before using your new price computing scale, please read the operating instructions.
Warning before connecting power plug:
Do not place a load on the weighing pan before connecting the power supply.
Check the power requirement label next to the power switch on the lower left side of the body
of the SF/SG to confirm that it corresponds to your local power requirements. Or when appropriate, check the AC adapter.
AC ADAPTER
TB-162
91-45273
INPUT: AC100V
OUTPUT: DC7.5V 250 mA
FUSE T 200mA
9V 70mA
Unpacking and inspecting
The SF/SG price computing scales are precision instruments, please handle them with care.
Please inspect your new SF/SG when unpacking, and retain the shipping container in the event
that you need to return the unit to your dealer for repair.
The following items should be included in your shipping container:
SF/SG price computing scale.
AC power adapter (except SF-A).
Optional rechargeable battery (SF-C), if ordered.
Optional RS-232C, if ordered.
Instructional manual
Various models are capable of using rechargeable or 6 D size replaceable batteries. D size replaceable batteries are not shipped with the unit and must be purchased locally:
SF-6KA, 15KA, 30KA AC only
SF-6KB, 15KB, 30KB AC adapter (D size capable)
SF-6KC, 15KC, 30KC AC adapter (rechargeable battery capable)
SG-6KA, 15KA, 30KA AC adapter (D size capable)
A&D Company, Limited
2
SF/SG Series Specifications
Specification Table
Price
Model Capacity Display Type AC Type Battery Lookup Options
Type Capability
SF- 6KA 6kg x 2g VFD Tower AC hardwired No 30 RS-232C SF-15KA 15kg x 5g VFD Tower AC hardwired No 30 RS-232C SF-30KA 30kg x 10g VFD Tower AC hardwired No 30 RS-232C
SF- 6KB 6kg x 2g LCD Tower AC adapter 6 D size 30 RS-232C SF-15KB 15kg x 5g LCD Tower AC adapter 6 D size 30 RS-232C SF-30KB 30kg x 10g LCD Tower AC adapter 6 D size 30 RS-232C
SF- 6KC 6kg x 2g VFD Tower AC adapter Rechargeable* 30 RS-232C SF-15KC 15kg x 5g VFD Tower AC adapter Rechargeable* 30 RS-232C SF-30KC 30kg x 10g VFD Tower AC adapter Rechargeable* 30 RS-232C
SG- 6KA 6kg x 2g LCD Table top AC adapter 6 D size 12 RS-232C SG-15KA 15kg x 5g LCD Table top AC adapter 6 D size 12 RS-232C SG-30KA 30kg x 10g LCD Table top AC adapter 6 D size 12 RS-232C
*Note:
1. Rechargeable batteries are sold as an option.
2. D size batteries are not included with the unit & must be purchased locally.
Numerical Digits
Display:
Weight Display: 5 5 Price Display: 7 7 Unit Price Display: 6 6
LCD Type VFD Type
Resolution:
Sensor:
Character Size:
Weight Display: 18mm 13mm Price Display: 20mm 13mm Unit Price Display: 18mm 13mm
Weighing Pan Size:
300mm x 280mm
Physical Weight of the Scale:
SF Series Approximately 5.5kg SG Series Approximately 4.5kg
Operating Temperature:
-10ºC ~ 40ºC / 14ºF ~ 104 ºF; RH less than 85%
1/3000
Strain gauged load cell
3
SF/SG Series Main Operating Components
Power Switch
turns the power to
the unit on and off.
Standby/Operate
turns displays on and off , but does not control power.
1
8
Memory storage locations
WEIGHT kg UNIT PRICE $/kg
NET
ZERO
88888
88888
88888 88888
9
10
11
12
5
6
7
8
1
2
3
4
888888
888888
888888 888888
CHANGE
7
4
5
1
2
PRICE $
8888888
8888888
88888888888888
8
9
10
6
3
C
O
O
Change
TTL
(
M+
(
X
T
CE
MEM
O
O
M+
*
WEIGHT
88888
88888
88888 88888
Net Zero
PRICE
8888888
8888888
88888888888888
Total M+
kg
$
UNIT PRICE
Multiple displays
• Weight of product
888888 888888
Change
Max. 15kg Min 0.1kg e=0.005kg
SF-15KA
$/
kg
888888
888888
•Zero & Tare
• Price of product
•Memory & total sale
• Unit price of product ($/kg )
•Payment received
•Change required
24
25
26
16
17
9
10
1
2
27
28
18
19
11
12
3
4
29
20
5
30
21
13
14
6
7
22
23
4
15
1
2
7
0
(
8
9
(
X
CE
*
T
MEM
O
M+
5
6
3
C
.
.
.
Change
1~0
C
1
CHANGE
*
M+
STANDBY/OPERATE: Turns the displays on and off (does not turn power off).
Ten numerical keys to enter price and weight values.
CANCEL: Cancels key input, Unit Price, and Total Price entries
CHANGE: Calculates the change due to the customer after payment.
PRINT key
Stores each entry made during a customers purchase, allowing calculation for totals & change.
CE
MEM
0
ZERO
(
MODE
X
T
TARE
CLEAR FROM MEMORY: Clears prices entered by the M+ key.
MEMORY RECALL: Allows access to product prices stored in memory.
ZERO: Zeros the weight display when no weight is on the weigh pan, to provide accurate calculations.
Acts as a TOTAL key to calculate
(
the total price at the end of a sales transaction.
MULTIPLIER key: Calculate the total value of more than one of the same item.
TARE: Subtracts unwanted weight, such as the weight of a container, from price calculations.
4
SF/SG Series Operating Instructions
1. Zero Point Adjustment
The zero point is automatically adjusted when power is turned on. If the display shows a positive or negative weight, the scale must be re-zeroed.
How to re-zero:
1. Assure that nothing is on the weigh pan.
2. Press
3.
0
0
0 0
0
ZERO
should appear on the weight display
Table top type Tower type
NET
ZERO
0.000
0.000
0.0000.000
0.000
0.000
0.0000.000
NET ZERO
2. Tare Adjustment
When weighing with a container, it is necessary to TARE out the weight of the container in order to get an accurate price/weight reading.
How to operate TARE:
1. Place empty container (100g) on the weigh pan. Display reads
2. Press
T
TARE
100
100
100 100
:
3. The weight display display should read:
Table top type Tower type
NET
ZERO
4. When removing the weight from the pan the display reads
0.000
0.000
0.0000.000
0.000
0.000
0.0000.000
NET ZERO
-100
100
100 100
Note:
When a TARE weight has been set, it is not possible to set a new TARE weight of a lower value by the instructions above. It is necessary to delete the previous TARE first, before entering a TARE of lower value.
5
SF/SG Series Operating Instructions
3. Keypad Tare Entry
(
Usually this function is inhibited. If necessary, please ask your dealer.)
In addition to pressing to TARE out an empty container that has been placed on the
weigh pan, it is also possible to enter a TARE value with the numerical 10 key pad.
How to enter TARE using the 10 Key Pad:
Step 1: With no weight on weigh pan, turn on the SF/SG.
Displays will read:
UNIT PRICE
0.000
0.000
0.0000.000
If a unit price has previously been entered, it will be displayed instead of
,
2.00
2.00
2.002.00
Step 2: Enter the new TARE (e.g. 100g) with the 10 key pad
this is OK
.
T
TARE
WEIGHT
0.000
0.000
0.0000.000
NET ZERO
Tower type
0.00 -
0.00 -
0.00 -0.00 -
.
example
(
Unit price display reads:
UNIT PRICE
1.00
1.00
1.001.00
7 8 9
4 5 6
1 2 3
MODE
CE
(
X
MEM
TARE
ZERO
T
0
Step 3: Press TARE button
Weight display shows new tare
0 C
Numerical 10 Key Pad
WEIGHT
-0
-0....100
100
-0-0
100100
NET ZERO
1
CHANGE
Tower type
M+
*
Keyboard Tare continued...
6
SF/SG Series Operating Instructions
Note about keyboard TARE:
1. If you enter a tare weight greater than the weighing capacity of the scale an error message
will display:
2. When a TARE weight has been set, it is not possible to set a new TARE weight of a lower value by the instructions above. It is necessary to delete the previous TARE first, before entering a TARE of lower value.
Example
3. Any previous TARE entries will be cancelled when the
4.
To cancel a TARE weight that has been entered, remove any weight from the weigh pan and press
Err tr
WEIGHT
0.000
0.000
0.0000.000
NET ZERO
UNIT PRICE
------
------
------------
0
ZERO
PRICE
Err tr
key is pressed.
T
TARE
4. Setting Unit Price
1. Enter Unit Price by 10 key pad. Up to 6 digits may be entered.
The example below shows the entry of a unit price of $5.50:
WEIGHT
0.000
0.000
0.0000.000
NET ZERO
2. Unit price entry must be completed within 3 seconds. Any delay beyond 3 seconds will require the unit price to be re-entered.
UNIT PRICE
5.50
5.50
5.505.50
PRICE
0.00
0.00
0.000.00
7
SF/SG Series Operating Instructions
5. Storing a Unit Price in Memory
It is possible to store unit prices in memory for quick recall.
A. The SF model has 30 Price Look-Up keys (PLU). B. The SG model has 12 PLU’s
The following instructions explain how to assign a unit price to a PLU key.
Step 1: Enter desired unit price by the 10 key pad.
Step 3: Press the desired PLU key
within 3 seconds of entering unit price in 10 key pad. ( If you do not select this key within 3 seconds, a beep will sound ).
The unit price is now stored in the selected key.
WEIGHT kg UNIT PRICE $/kg
NET
ZERO
0.000
0.000
0.000 0.000
9
O
10
11
5
1
2
12
6
7
8
3
4
1
5.50
5.50
5.50 5.50
CHANGE
7
8
4
5
6
2
3
Step 2: Press
0.00
0.00
0.00 0.00
9
C
A&D
Max 15kg Min 0.1kg e =0.005kg
(
10
(
CE
.
.
.
Change
*
SG-15KA
SG Model
MEM
PRICE $
X
T
O
M+
6. Recalling a Unit Price from Memory
Step 1: Press the desired PLU key
7. Totaling Multiple Items with Unit Prices Stored in PLU Memory
Example: A. Weight 1000g, Unit Price= $ 5.00 / 100g, PLU key #1
B. Weight 5000g, Unit Price= $10.00 / 100g, PLU key #2
Step 1: With the weigh pan empty, assure that the weight display reads
Step 2: Place the first item on the weigh pan. Step 3: Select desired PLU key (PLU key #1 in this example).
0.000
0.000
0.0000.000
.
MEM
TTL
M+
Step 4: Press to add to purchase total.
M+
Step 5: Remove item from weigh platform, put second item (item b) on weigh pan and repeat
Steps 2~4, using appropriate PLU key.
Continue this process until all of the items have been weighed and the price totals are stored in memory.
Final Step - Recalling TOTAL.
(
Press Using above example, displays read:
(
MODE
8. Clearing Totaling Memory:
WEIGHT
Total
Total
TotalTotal
Totaling Indication
Push when in the TOTAL mode.
Total Number of items calculated
C
UNIT PRICE
2
2
2 2
PRICE
550.00
550.00
550.00550.00
Total Price
Totaling continued...
8
SF/SG Series Operating Instructions
Note about Totaling Items:
A. The 10 key pad, PLU keys, and multiplier key may all be used during a single
X
transaction. (See X key operation below.)
B. An item must be removed from the weigh pan before another item can be weighed & entered
into totaling memory. The weight display must return to zero to re-set for next weighing.
C. The SF/SG have automatic power off capability. If there is a long delay in the middle of a transaction
(
which causes the scale to shut off, press , displays read
displays will show the last total calculated. Additional items may now be calculated into the total.
9. Multiplier Function:
(Max. pieces allowed = 99; Max. unit price = 999999)
Not all purchased items are sold by weight, items like canned goods, milk, apples, etc. may be sold by the piece.
The SF/SG allow the operator to calculate all items purchased, those that require weigh/price calculation and those that are sold by the piece, and provides a total price for both
The Multiplier Function allows the operator to tell the scale how many of a given item he would like to calculate.
s
. Press and the
0
MODE
.
(
Example: A customer is purchasing 10 cans of tuna fish at a cost of $1.00 per can.
Step 1: Enter unit price by the appropriate PLU key, or by 10 key pad. Unit price is displayed.
WEIGHT kg UNIT PRICE $/kg
NET
ZERO
pc 10
pc 10
Step 2: Press
X
is displayed.
PC
PC
PCPC
Step 3: Enter multiplier by 10 key pad.
Example: 10 cans of tuna fish.
Result:
WEIGHT
PC 10
PC 10 1.00
PC 10PC 10
UNIT PRICE
1.00 10.00
1.00 1.00
10.00
10.00 10.00
PRICE
O
pc 10pc 10
9
5
1
2
1.00
1.00
11
4
8
CHANGE
12
1
1.00 1.00
7
8
4
5
6
2
3
10
6
7
3
9
10
C
.
Change
A&D
Max 15kg Min 0.1kg e =0.005kg
10.00
10.00
10.00 10.00
(
(
CE
.
.
*
SG-15KA
PRICE $
X
MEM
M+
T
O
TTL
M+
9
SF/SG Series Operating Instructions
10. Calculating Correct Change for the Customer
The purpose of this function is to allow the operator to determine the correct change to return to the customer once payment has been made.
Example: There have been 4 entries and the total cost of the transaction is $80.00.
(
Step 1: Press . Displays
Step 2: Enter customer payment by 10 key pad (Example: $100)
Step 3: Press . Displays:
Note: Push if an error is made while entering the amount of money received from the customer.
C
11. Clear Entry Function
The CE key is designed to clear the last entry made by the key, which places entries into
memory for totaling.
Step 1: You have entered a value with the M+ key and wish to cancel it.
(
MODE
1
CHANGE
Displays:
WEIGHT
total
total 4
totaltotal
WEIGHT
Rece iu
Rece iu 100.00
Rece iuRece iu
WEIGHT
CE
UNIT PRICE
4 80.00
4 4
UNIT PRICE
100.00 80.00
100.00 100.00
UNIT PRICE
20.00
20.00
20.00 20.00
M+
PRICE
80.00
80.0080.00
PRICE
80.00
80.00 80.00
TOTAL M+
PRICE
CH
CH
CH CH
TOTAL M+
Example: Assume that you entered 3 values totaling $55.00. The last (3rd) entry was $10.00.
(
Step 2: Press the key. Displays:
Step 3: Press the key. Displays:
Note:
A. Only the last M+ entry can be cleared from memory by the CE key.
B. Pressing the key while in the total mode will delete all entries in memory.
C. Pressing the key will
1. Active PLU entries. 1.
2. Active 10 key pad entries.
3. Active key entries.
4. Improper entry of money received from customer.
MODE
CE
(
C
C
X
also delete: Pressing the key will not delete:
WEIGHT
total
total
totaltotal
WEIGHT
total
total 2
totaltotal
UNIT PRICE
3
UNIT PRICE
2 45.00
2 2
WEIGHT
PC
PC 0.00
PC PC
Press key to cancel this operation.
PRICE
3 55.00
55.00
3 3
55.00 55.00
TOTAL M+
PRICE
45.00
45.00 45.00
TOTAL M+
C
UNIT PRICE
0.00 00.00
0.00 0.00
(
(
MODE
PRICE
00.00
00.00 00.00
entries.
10
SF/SG Series Operating Instructions
12. Automatic Cancellation of Unit Price
In very busy applications, it may be more convenient for the Unit Price entry to return to zero after each operation. (F2 should be “0”.)
To do this, press the key while the display is in normal operation.
WEIGHT
Automatically clears unit price.
WEIGHT
Does not automatically clears unit price.
While the display shows the above, press again to change the setting.
ut
1
CHANGE
UNIT PRICE
ut c
c
utut
c c
UNIT PRICE
Ut nc
Ut ncUt nc
PRICE
TOTAL M+
PRICE
Ut nc
TOTAL M+
1
CHANGE
13. Setting “F” Functions
F functions allow the programming of various functions of the SF/SG Price Computing scales. Following is a brief description of these functions and how to program them.
Step 1: Starting with the power off, hold and turn on the power switch
Displays
0
ZERO
WEIGHT
UNIT PRICE
FFFF 1
1 ----••
1 1
PRICE
TOTAL M+
Step 2: Press to select the desired F function group.
*
Step 3: Using the 10 key pad and the key, select and cancel
the various settings for each “F” function. Press
to move to the next “F” function. Settings
Use to store each setting selected.
MEM
F1: Auto display off 0: Yes 1: No F2: Cancellation of unit price 0: Selectable 1: No 2: Yes F3: Output Data 0: Print key mode A 1: Print key mode B
F4: Baud Rate 0: 600 bps 1: 1200 bps
F5: Parity Bit 0: 7 bits (Even) 1: 8 bits (No parity)
C
2: Command mode 3: Stream mode
2: 2400 bps 3: 4800 bps 4: 9600 bps
*
UNIT PRICE
F 1 - 0
F 1 - 0
F 1 - 0F 1 - 0
F1-0
F2-0
F5-0
F3-0
F4-0
11
Loading...