Acu-Rite 1036 User Manual

Professional Weather Center
CONTENTS
Unpacking Instructions ........... 2
Package Contents .................. 2
Product Registration ............... 2
Features & Benets: 5-in-1 ....... 3
Features: Display Unit ............ 4
Back of Display Unit ............... 6
Setup .................................... 7
5-in-1 Sensor Setup ................ 7
Display Unit Setup ................. 8
Set the Time & Date ............... 9
Measurement Units ...............10
Set Language .......................10
5-in-1 Sensor Installation ........ 12
Instruction Manual
model 01036
PC Connect Overview ...........13
PC Connect USB Modes ........13
PC Connect Software ............14
Using the Weather Center .....15
Weather Ticker .....................16
Programmable Alarms ...........18
Troubleshooting ................... 20
Care & Maintenance ............ 23
Calibration .......................... 23
Specications ....................... 25
FCC Information .................. 25
Customer Support ................ 26
Warranty............................. 26
Questions? Contact Customer Support at
(877) 221-1252 or visit www.AcuRite.com.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety
and retain it for future reference.
Unpacking Instructions
Remove the protective lm that is applied to the LCD screen prior to using this product. Locate the tab and peel off to remove.
Package Contents
1. Display unit with tabletop stand
2. 5-in-1 sensor
3. Sensor mounting bracket
4. Mounting hardware
5. Snap-in debris lter for rain collector
6. Power adapter
7. USB cable
8. Instruction Manual
IMPORTANT
PRODUCT REGISTRATION
Register online
to receive 1 year
warranty protection
www.AcuRite.com
PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE
Register a Product
2
Features & Benets
11
6
7
1
2
9
5
43
8
10
5-in-1 SENSOR
1. Rainfall Collector Funnel
2. Solar Cell Panel
Converts sunlight into power to run internal aspirating fan.
Internal Aspirating Fan
(not shown) Draws ambient air into
sensor to reduce solar radiation heating, resulting in more accurate
temperature measurement.
3. A-B-C Switch
ID code that must match display’s A-B-C switch to ensure units synchronize.
4. Battery Compartment
5. Temperature & Humidity Sensors
(internal)
6. Mounting Point
7. Wind Speed Anemometer
8. Wind Direction Vane
9. Mounting Bracket
10. Mounting Hardware
Includes anchors & screws.
Qty Diameter Length 4 #4 1” 2 #6 ½”
11. Debris Filter
Snaps into rain collector to lter out twigs, leaves, etc.
3
Features & Benets
Display Unit
1 32 4 1
41
40 39
38 37 36 35
34 33
32
31
30
29 28
5 6
7 8
9
10 11
12 13
14 15 16 17
18 19
20
26 27 26 23 25 24 23 22 21
4
1. Previous 2 Wind Directions
2. Current Wind Direction
3. Touch Activated Backlight Momentary during battery power,
always on/off for power adapter.
4. Current Wind Speed
5. Current Outdoor Temperature Arrow icon indicates direction
temperature is trending.
6. Outdoor Temperature Alarm On Indicator
7. Current Outdoor Humidity Arrow icon indicates direction
humidity is trending.
8. Outdoor Humidity Alarm On Indicator
9. Current Rainfall Accumulates data during rainfall.
10. Rainfall Alarm On Indicator
11. 12 to 24 Hour Weather Forecast
Self-Calibrating Forecasting pulls data from your 5-in-1 sensor to generate your personal forecast.
12. All-Time Rainfall
13. Current Month Total Rainfall
14. Date
15. Clock
16. Display Low Battery Indicator
17. Selectable Category
18. Record Highs
Shown for current category selected on the display (#17).
19. Record Lows Shown for current category selected
on the display (#17).
20. Weather Ticker™
21. All-Time Records Button Press for all-time low and date
recorded for current category selected on display (#17). Press twice for all-time high and date recorded.
22. Activate Weather Ticker Message
23. “▲“/”▼“ to Select Category (#17) & Adjust Settings
24. Weather Ticker Manual Cycle Press to advance through messages.
25. “ “ Button
for setup preferences.
26. Alarm On/Off Button
Activate alarm; press and hold to adjust alarm values.
27. Deactivate Weather Ticker Message
28. Indicates Deactivated Weather Ticker Message During ticker customization mode.
29. Indicates Active Weather Ticker Message
During ticker customization mode.
30. Programmable Alarm Settings
31. Alarm On/Off Indicator
for Selectable Category (#17).
32. Low Battery Indicator
33. 5-in-1 Sensor Signal Strength
34. Learning Mode Icon
Disappears after weather forecast self-calibration is complete.
35. Weather Select Button Press to change the Weather Select
category data being displayed.
36. Current Barometric Pressure
Arrow icon indicates direction pressure is trending.
37. Weather Select (top to bottom)
Heat index, dew point, wind chill, indoor temperature / humidity, rainfall rate (rain per hour).
38. Storm Alert Alarm On Indicator
39. Average Wind Speed
of all speeds from past 2 minutes.
40. Wind Speed Alarm On Indicator
41. Peak Wind Speed Highest speed from past 60 minutes.
5
Back of Display Unit
6
7
8
9
1
2
3 4
5
BACK OF DISPLAY UNIT
1. Plug-in for Power Adapter
2. Plug-in for USB Cable
3. Integrated Hang Hole
for easy wall mounting
4. MAC ADDRESS 12 digit unique ID required for
online connectivity functions
5. Backup Battery Compartment
6. A-B-C Switch ID code that must match 5-in-1
sensor’s A-B-C switch to ensure units synchronize
10
7. Clear Today
Clears data recorded since 12:00am
8. Clear All
Clears all recorded data without
having to reset time and date
9. Reset
Full reset to factory defaults
10. Power Adapter
11. USB Cable for PC Connection
12. Battery Compartment Cover
(not shown)
6
11
SETUP
5-in-1 Sensor Setup
Set the A-B-C Switch
1
Locate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B or C. You must select the same letter choices for both the sensor and the display unit in order for the units to synchronize.
Install or Replace Batteries
2
Batteries MUST be installed for this product to operate. AcuRite recommends high quality alkaline or lithium batteries for the best product performance. Heavy duty or rechargeable batteries are not
recommended.
The 5-in-1 sensor requires lithium batteries in low temperature conditions. Cold temperatures can
cause alkaline batteries to function improperly. Use lithium batteries in
the 5-in-1 sensor for temperatures
below -4ºF / -20ºC.
1. Slide off the battery
compartment cover.
2. Insert 4 x AA batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery
compartment.
3. Replace the battery cover.
3
Remove Rain Gauge Stabilizer
Locate and remove the rain gauge
stabilizer (plastic tab) taped into
the bottom of the sensor. The rain
gauge will not function until this is
removed.
A-B-C Switch
1
Set to match
display unit
2
A B C
Install Batteries
4 AA Batteries
Rain Gauge Stabilizer
3
Remove and discard
7
Display Unit Setup
Set the A-B-C Switch
1
The A-B-C switch is located inside the battery compartment. It can be set to A, B or C. However, you must select the same letter
choices for both the sensor and
the display unit in order for the units to synchronize.
Plug Power Adapter into
2
Electric Outlet
A-B-C Switch
1
set to match sensor
A B C
3
4
Write Down
3
MAC ADDRESS
12 digit number
Write Down the MAC ADDRESS
12 digit unique ID needed for online connectivity functions.
Install or Replace Backup Batteries (optional)
Insert 6 x AA alkaline batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery
compartment.
Install Backup
4
Batteries
6 AA Batteries (optional)
Plug in Power
2
Adapter
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals.
IMPORTANT: Batteries are a backup power source to preserve records in the event of a power outage. Power adapter is the recommended
primary power source to enjoy the full functionality of this product.
8
Set the Time & Date
The clock and calendar are utilized to time stamp history records and other data, so it is important to set the time and date soon after you power on the display unit.
Set the Time
1. Press the “▲“ or “▼“ buttons until
“SET CLOCK?” is displayed on the Selectable Category part of the display unit.
2. Press the “ ” button to set the clock.
3. Press the “▲“ or “▼“ buttons to adjust the
hour. Note the “AM” and “PM” indicators.
4. Press the “ ” button to conrm hour selection.
5. Press the “▲“ or “▼“ buttons to adjust minutes.
6. Press the “ ” button to conrm minute selection.
The clock is now set.
Note: The “ ” stays in Selectable Categories, even after setup.
Set the Date
1. Press the “▲“ or “▼“ buttons until
“SET DATE?” is displayed on the Selectable Category part of the display unit.
2. Press the “ ” button to set the date.
3. Press the “▲“ or “▼“ buttons to adjust the month.
4. Press the “ ” button to conrm month selection.
5. Press the “▲“ or “▼“ buttons to adjust the
day.
6. Press the “ ” button to conrm day selection.
7. Press the “▲“ or “▼“ buttons to adjust the
year.
8. Press the “ ” button to conrm year selection.
The date is now set.
9
Loading...
+ 19 hidden pages