ACTi KCM-5211 Installation Guide

Page 1
KCM-5211
18x Zoom H.264 4-Megapixel IP D/N PoE Box Camera
(DC 12V / PoE)
Ver. 2014/10/15
Page 2
www.acti.com
KCM-5211 Hardware Manual
Table of Contents
Precautions 3
Safety Instructions ........................................................................... 4
Introduction 6
Package Contents ............................................................................. 6
Physical Description ........................................................................ 7
Basic Connections ......................................................................... 10
Serial Port Connection ................................................................. 11
Accessing the Camera 13
Configure the IP Address ............................................................... 13
Access the Camera ......................................................................... 17
2
Page 3
www.acti.com
KCM-5211 Hardware Manual
Precautions
Read these instructions
You should read all the safety and operating instructions before using this product.
Heed all warnings
You must adhere to all the warnings on the product and in the instruction manual. Failure to follow the safety instruction given may directly endanger people, cause damage to the system or to other equipment.
Servicing
Do not attempt to service this video device yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
Trademarks
All names used in this manual are probably registered trademarks of respective companies.
Liability
Every reasonable care has been taken during the writing of this manual. Please inform your local office if you find any inaccuracies or omissions. We cannot be held responsible for any typographical or technical errors and reserve the right to make changes to the product and manuals without prior notice.
FCC/CE Regulation
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the users will be required to correct the interference at their own expense.
3
Page 4
www.acti.com
KCM-5211 Hardware Manual
Safety Instructions
Don’t use the power supply with other voltages
This device is likely to be damaged or damage other equipments / personnel, if you use a power supply with different voltage than the one included with this device. All warranty of this product will be voided in the situations above.
Don’t open the housing of the product
Cleaning
Disconnect this video product from the power supply before cleaning.
Attachments
Do not use attachments not recommended by the video product manufacturer as they may cause hazards.
Water and Moisture
Do not use this video product near water, for example, near a bathtub, washbowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool and the like.
Don’t use accessories not recommended by the manufacturer
Only install this device and the power supply in a dry place protected from weather
Servicing
Do not attempt to service this video product yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
Damage Requiring service
Disconnect this video product from the power supply immediately and refer servicing to qualified service personnel under the following conditions.
1) When the power-supply cord or plug is damaged
2) If liquid has been spilled, or objects have fallen into the video product.
3) If the video product has been directly exposed to rain or water.
4) If the video product does not operate normally by following the operating Instructions in this manual. Adjust only those controls that are covered by the instruction manual, as an improper adjustment of other controls may result in damage, and will often require extensive work by a qualified technician to restore the video product to its normal
4
Page 5
www.acti.com
KCM-5211 Hardware Manual
operation.
Safety Check
Upon completion of any service or repairs to this video product, ask the service technician to perform safety checks to determine if the video product is in proper operating condition.
5
Page 6
www.acti.com
KCM-5211 Hardware Manual
Introduction
Package Contents
KCM-5211 QIG
Product CD Terminal Blocks for Power, DI/O and
Serial Port
Accessories Warranty Card
*For the mounting block, please attach the flat side towards the front of camera. There are two types of mounting blocks, and this device uses the black version.
6
Page 7
www.acti.com
KCM-5211 Hardware Manual
Physical Description
1) Digital Input / Output
Used in applications like motion detection, event triggering, time lapse recording, alarm notifications, etc., the I/O terminal connector provides the interface to:
2 Transistor Outputs - For connecting external
devices such as relays and LEDs. Connected devices can be activated by Output buttons on the Live View page or through video management software. Connect DO1 and DO2 to their closest 12V pin to activate.
2 Digital Inputs - An alarm input for connecting devices that can toggle between an open
and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. The device will detect the change in digital input and transmit the signal to video surveillance servers. The I/O terminal pins are numbered right to left,
Connect input/output devices to the camera as follows:
1. Attach the cables for the device securely to the supplied green connector block. Connect DI
pins to GND pins, and DO pins to 12V pins. Link pins 1/3, 2/4, 5/7,6/8.
2. Once cables are connected, push connector block into the terminal connector on camera.
7
Page 8
www.acti.com
1 2 3
FUSE 1A
NPN
DC TO DC
DI
DO
3.3V
DC POWER
GND
1 2 3 4
CONVERTER
EARTH GND
DO
DI
RELAY
SW
DIODE
DEVICE
-
+
POWER INPUT
CAMERA
KCM-5211 Hardware Manual
2) Serial Port
This port connects to serial devices via RS-485 or RS-422 protocols. Use the supplied serial port terminal block to connect the wires from the camera to the serial device. See Serial Port Connection on page 11 for connection details.
3) Ethernet Port
The IP device connects to the Ethernet via a standard RJ45 connector. Supporting NWAY, this IP device can auto detect the speed of local network segment (10Base-T/100Base-TX Ethernet).
4) Reset Button
Step 1: Switch off IP device by disconnecting the power cable Step 2: Press and continue to hold the Reset Button (with a sharp tipped object, like a pen.) Step 3: Reconnect the power cable while continuing to hold the reset button. The red
Power LED light will flash on for 3 second first, turn off for about 15 seconds, flash on for another second and turn off again. By this time the reset to default operation is already completed. This will take around 20 seconds from power up. You may then release the reset button. This length of time fluctuates slightly with the environment. The Power LED light will come back on and stay on after a few more seconds. The unit will start up with factory default settings automatically.
8
Page 9
www.acti.com
On (3s)
On
1s
Power On
About 20 Seconds
Stay On
Off (about 15s)
Off (10~15s)
Restore to Default
Complete
KCM-5211 Hardware Manual
5) Audio Input / Output
The IP device supports audio input and output with earphone jack
6) Micro SDHC Card Slot
Insert your Micro SDHC card here for local recording on camera
7) Power LED
This LED light will indicate current camera status.
8) Power Input
If you use Power Adaptor to run the device, please connect the power adaptor to the terminal block in the way shown below.
9
Page 10
www.acti.com
KCM-5211 Hardware Manual
Basic Connections
Follow the procedures below to connect the IP device to the respective apparatuses.
If you have a PoE(Power over Ethernet) supported switch or injector:
1) Connect your IP Box Camera to the Switch / Injector by CAT5 or CAT6 cables with RJ45 connector.
2) Connect your Switch / Injector to PC with another CAT5 / CAT6 network cable.
If your switch does not support PoE, and you are powering the camera with power adaptor:
1) Connect the power adaptor to IP Box Camera
2) Connect IP devices Ethernet port to Network switch (via RJ45 connectors).
Connect a PC to the Ethernet switch (via RJ45 connectors)
Please refer to our PoE Guide for more details on Power over Ethernet related concepts.
10
Page 11
www.acti.com
Terminal Block
Wire Mapping
Pin Number / Label
Camera Pin
PT Scanner Pin
1
TX +
TX +
DATA +
2
TX -
TX -
DATA -
3
RX+
-
4
Rx-
-
Terminal Block
Wire Mapping
Pin Number / Label
Camera Pin
PT Scanner Pin
1
TX +
TX +
RX +
2
TX -
TX -
RX -
3
RX+
RX +
TX +
4
Rx-
RX -
TX -
KCM-5211 Hardware Manual
Serial Port Connection
The zoom camera can be connected to a Pan-Tilt (PT) Scanner (Pan-Tilt Head) using the serial port connector. This allows the zoom camera to do pan and tilt using the Pelco-D protocol. Most PT scanners accept Pelco-D and Pelco-P protocol commands via RS-485 or RS-422 connection, which are both supported by your camera.
Check the connection available on the PT scanner and connect it to your camera following the procedures below.
1. Map the wires from the PT scanner to your camera using the supplied terminal block according to one of the tables below.
Via RS-485 Connection
Via RS-422 Connection
NOTE: The pins of the PT Scanner may be labeled differently depending on the location or
country where the scanner is purchased. For example, some devices may have RS-485 DATA+ pins labeled as “TX+”, “RX+”, "A” or “485+”, etc. Refer to the scanner documentation or contact the manufacturer to verify the corresponding pin labels and ensure proper wiring connection.
CAUTION: Incorrect wiring may cause damage to the connected devices.
DISCLAIMER: ACTi will not be responsible for any damage caused by improper wiring.
2. Connect a ground wire to one of the GND terminal pins of your camera (via Power or DI/O terminals) to complete the connection.
11
Page 12
www.acti.com
KCM-5211 Hardware Manual
For more information on connecting PT scanners, please refer to the Knowledge Base article:
Pan and Tilt Scanner for ACTi Zoom Cameras (http://www.acti.com/support/KnowledgeBase/outside/detail.asp?KB_ID=KB20110120001)
available on the website.
12
Page 13
www.acti.com
KCM-5211 Hardware Manual
Accessing the Camera
Configure the IP Address
In order to be able to communicate with the camera from your PC, both the camera and the PC have to be within the same network segment. In most cases, it means that they both should have very similar IP addresses, where only the last number of the IP address is different from each other. There are 2 different approaches to IP Address management in Local Area Networks – by DHCP Server or Manually.
Using DHCP server to assign IP address
If you have connected the computer and the camera into the network that has a DHCP server running, then you do not need to configure the IP addresses at all – both the camera and the PC would request a unique IP address from the DHCP server automatically. In such case, the camera will immediately be ready for the access from the PC. The user, however, might not know the IP address of the camera yet. It is necessary to know the IP address of the camera in order to access it using a Web browser.
The quickest way to discover the cameras in the network is to use the simplest network search, built in the Windows system – just by pressing the Network icon, all the cameras of the local area network will be discovered by Windows, thanks to the UPnP function support of our cameras. In the example below, the camera that has just been connected to the network is successfully found.
When the left mouse is clicked on the camera model name, the default browser of the PC is automatically launched and the IP address of the target camera is already filled in the address bar of the browser.
13
Page 14
www.acti.com
KCM-5211 Hardware Manual
If you work with our cameras regularly, then there is even a better way to discover the cameras in the network – by using IP Utility. The IP Utility is a light software tool that can not
only discover the cameras, but also list lots of valuable information, such as IP and MAC addresses, serial numbers, firmware versions, etc, and allows quick configuration of multiple devices at the same time.
The IP Utility can be downloaded for free from http://www.acti.com/IP_Utility When you launch IP Utility, the list of connected cameras in the network will be shown. See sample illustration below:
You can quickly notice the camera model in the list. Click on the IP address to automatically launch the default browser of the PC with the IP address of the target camera already filled in the address bar of the browser.
14
Page 15
www.acti.com
1
2
3
4
KCM-5211 Hardware Manual
Use the default IP address of the camera
If there is no DHCP server in the given network, the user may have to manually assign the IP addresses to both the PC and the camera to make sure they are in the same network segment.
When the camera is plugged into the network and it does not detect any DHCP services, it will automatically assign itself a default IP:
192.168.0.100
Whereas the default port number would be 80. In order to access that camera, the IP address of the PC has to be configured to match the network segment of the camera.
Manually adjust the IP address of the PC
In the following example, based on Windows 7, we will configure the IP address to
192.168.0.99 and set Subnet Mask to 255.255.255.0 by using the steps below:
15
Page 16
www.acti.com
KCM-5211 Hardware Manual
Manually adjust the IP addresses of multiple cameras
If there are more than one camera to be used in the same local area network and there is no DHCP server to assign unique IP addresses to each of them, all of the cameras would then have the initial IP address of 192.168.0.100, which is not a proper situation for network devices – all the IP addresses have to be different from each other. The easiest way to assign cameras the IP addresses is by using IP Utility:
With the procedure shown above, all the cameras will have unique IP addresses, starting from
192.168.0.101. In case there are 20 cameras selected, the last one of the cameras would have
the IP 192.168.0.120.
Later, by pressing the Refresh button of the IP Utility, you will be able to see the list of cameras with their new IP addresses.
Please note that it is also possible to change the IP addresses manually by using the Web browser. In such case, please plug in only one camera at a time, and change its IP address by using the Web browser before plugging in the next one. This way, the Web browser will not be confused about two devices having the same IP address at the same time.
16
Page 17
www.acti.com
Functionality
Internet Explorer
Live Video
Yes
Live Video Area Resizable
Yes
PTZ Control
Yes
Capture the snapshot
Yes
Video overlay based configuration (Motion Detection regions, Privacy Mask regions)
Yes
All the other configurations
Yes
KCM-5211 Hardware Manual
Access the Camera
Now that the camera and the PC both have their unique IP addresses and are under the same network segment, you can use Microsoft Internet Explorer on the PC to access the camera.
Note: Only Microsoft Internet Explorer is supported by the camera at the time of writing this documentation. Please refer to our website (www.acti.com) for future upgrades.
Internet Explorer supports the following functionalities:
The ActiveX control for video stream management will be downloaded from the camera directly – the user has to accept the use of such control when prompted so. No other third party utilities are required to be installed in such case.
Assuming that the cameras IP address is 192.168.0.100, you can access it by opening the Web browser and typing the following address into the Web browsers address bar:
http://192.168.0.100
17
Page 18
www.acti.com
KCM-5211 Hardware Manual
Upon successful connection to the camera, the user interface called Web Configurator would appear together with the login page. The HTTP port number was not added behind the IP address since the default HTTP port of the camera is 80, which can be omitted from the address for convenience.
Before logging in, you need to know the factory default Account and Password of the camera.
Account: Admin
Password: 123456
For further operations, please refer to the Firmware User Manual.
18
Loading...