Acroprint Relay Kit Instruction manual

R
Acroprint Relay Kit Instruction.
The Signal and Access Relay Box is designed for use with Acroprint's badge reading terminals. It has two independent types
of switching circuits, a switched AC power line circuit and a mechanical relay circuit. Either circuit may be used to control AC powered bells, alarms, horns, or door access electric strikes. DC and all low voltage powered devices MUST use the mechanical relay contacts (an external power source is required).
For direct AC power line switched circuits use CON1:
- Direct switching means that the input voltage on CON5 is directly switched to CON1
- If you are using the badge terminal's Bell signal, slide the SW2 switch to side marked BELL.
- If you are using the badge terminal's Access signal, slide the SW2 switch to side marked ACCESS.
For mechanical dry contact relay switching use CON2:
- Connect the device to the CON2 terminal strip using NO and COM connection points. Wires should be stripped ¼ inch.
- If you are using the badge terminal's Bell signal, slide the SW1 switch to side marked BELL.
- If you are using the badge terminal's Access signal, slide the SW1 switch to side marked ACCESS.
Notes:
1. Existing External Card Readers can be connected to CON4
2. SEE REVERSE SIDE FOR GRAPHICAL DEPICTION OF ELECTRICAL CONNECTIONS
Specifications:
Input Voltage: 120VAC/240VAC 50/60 Hz Input Current: 2 Amps Maximum AC Output: 120VAC/240VAC 50/60 Hz Relay Circuit: 5A at 250AC or 30VDC Operating Temp. 0 to 50 degrees C Humidity: 0 to 90% RH Non Condensing Dimensions: 8 ¾" x 6" x 2"
WARNING:
Your installation must meet all National and Local electric codes. A licensed electrician should perform installation.
p.t.o
06-0211-000 Rev.C
12:00
HORN
3/4"
CON 4
CON 5
CON 3
NEU
GND
SW2
BELL
AC OUT
ACCESS
LINE
DELAY
BELL
ACCESS
F1 2 AMP 250V
SW1
RELAY
F2 5 AMP 250V
GND
NO
NEU
COM
OUT
NC
AC
CON1
K1
CON 2
EXTERNAL
READER
SLOT
3/8"
ELECTRIC
STRIKE
DC
POWER
SUPPLY
DOOR