Accurex XUEB-200 Operator’s Manual

Page 1
Document 470312
Model XUEB - Series 100 and 200
Centrifugal Utility Fans
Installation, Operation and Maintenance Manual
Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage!
General Safety Information
Only qualified personnel should install this fan. Personnel should have a clear understanding of these instructions and should be aware of general safety precautions. Improper installation can result in electric shock, possible injury due to coming in contact with moving parts, as well as other potential hazards. Other considerations may be required if seismic activity is present. If more information is needed, contact a licensed professional engineer before moving forward.
1. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the National Fire Protection Agency (NFPA), where applicable. Follow the Canadian Electric Code (CEC) in Canada.
2. The rotation of the wheel is critical. It must be free to rotate without striking or rubbing any stationary objects.
3. Motor must be securely and adequately grounded.
4. Do not spin fan wheel faster than max cataloged fan RPM. Adjustment to fan speed significantly affects motor load. If the fan RPM is changed, the motor current should be checked to make sure it is not exceeding the motor nameplate amps.
5. Do not allow the power cable to kink or come in contact with oil, grease, hot surfaces or chemicals. Replace cord immediately if damaged.
6. Verify that the power source is compatible with the equipment.
7. Never open access doors to a duct while the fan is running.
DANGER
Always disconnect, lock and tag power source before installing or servicing. Failure to disconnect power source can result in fire, shock or serious injury.
CAUTION
When servicing the fan, motor may be hot enough to cause pain or injury. Allow motor to cool before servicing.
CAUTION
Precaution should be taken in explosive atmospheres.
DANGER
Pour écarter les risques d’incendie, de choc électrique ou de blessure grave, veiller à toujours débrancher, verrouiller et étiqueter la source de courant avant l’installation ou l’entretien.
ATTENTION
Lors de toute intervention sur la soufflante, le moteur peut être suffisamment chaud pour provoquer une douleur voire une blessure. Laisser le moteur refroidir avant toute maintenance.
ATTENTION
Faire preuve de précaution dans les atmosphères explosives.
Centrifugal Utility Fans 1
Page 2
Table of Contents
General Safety Information .................... 1
Receiving, Unpacking, Storage, Inspection ....... 3
Installation
Discharge Positions ........................ 4
UL/cUL 762 for Restaurant Exhaust ............. 4
Effect of Installation on Performance ............ 5
Pre-Starting Checks
Alignment of Pulleys and Belts ................ 5
Wheels and Wheel Rotation .................. 6
Mounting for Severe Duty Installation ............ 7
Maintenance Tapered Bushing Hub Installation and Removal ... 8
Bearing Lubrication Schedule ................. 9
Motor Maintenance ......................... 8
Wheel and Fastener Maintenance ............. 9
Belt Maintenance .......................... 9
Installation of Motor, Drives and Belt(s) ......... 10
Parts List ................................. 11
Troubleshooting ............................ 12
Our Commitment ........................... 12
Centrifugal Utility Fans2
Page 3
Receiving
Upon receiving the product, check to ensure all items are accounted for by referencing the delivery receipt or packing list. Inspect each crate or carton for shipping damage before accepting delivery. Alert the carrier of any damage detected. The customer will make a notation of damage (or shortage of items) on the delivery receipt and all copies of the bill of lading which is countersigned by the delivering carrier. If damaged, immediately contact your Accurex Representative. Any physical damage to the unit after acceptance is not the responsibility of Accurex LLC.
Unpacking
Verify that all required parts and the correct quantity of each item have been received. If any items are missing, report shortages to your local representative to arrange for obtaining missing parts. Sometimes it is not possible that all items for the unit be shipped together due to availability of transportation and truck space. Confirmation of shipment(s) must be limited to only items on the bill of lading.
Storage
Fans are protected against damage during shipment. If the unit cannot be installed and operated immediately, precautions need to be taken to prevent deterioration of the unit during storage. The user assumes responsibility of the fan and accessories while in storage. The manufacturer will not be responsible for damage during storage. These suggestions are provided solely as a convenience to the user.
Indoor -
fans and accessories is indoors, above grade, in a low humidity atmosphere which is sealed to prevent the entry of blowing dust, rain or snow. Temperatures should be evenly maintained between 30° to 110°F (-1° to 43°C), wide temperature swings may cause condensation and “sweating” of metal parts. All accessories must be stored indoors in a clean, dry atmosphere.
Remove any accumulations of dirt, water, ice, or snow and wipe dry before moving to indoor storage. To avoid “sweating” of metal parts allow cold parts to reach room temperature. To dry parts and packages use a portable electric heater to remove any moisture build up. Leave coverings loose to permit air circulation and to allow for periodic inspection.
The unit should be stored at least 3½ inches off the floor on wooden blocks covered with moisture proof paper or polyethylene sheathing. Aisles between parts and along all walls should be provided to permit air circulation and space for inspection.
The ideal environment for the storage of
(89 mm)
Outdoor - Fans designed for outdoor applications may
be stored outdoors, if absolutely necessary. Roads or aisles for portable cranes and hauling equipment are needed.
The fan should be placed on a level surface to prevent water from leaking into the fan. The fan should be elevated on an adequate number of wooden blocks so it is above water and snow levels and has enough blocking to prevent it from settling into soft ground. Locate parts far enough apart to permit air circulation, sunlight and space for periodic inspection. To minimize water accumulation, place all fan parts on blocking supports so rain water will run off.
Do not cover parts with plastic film or tarps as these cause condensation of moisture from the air passing through heating and cooling cycles. Fan wheels should be blocked to prevent spinning caused by strong winds.
Inspection and Maintenance During Storage
While in storage, inspect fans once per month. Keep a record of inspection and maintenance performed.
If moisture or dirt accumulations are found on parts, the source should be located and eliminated. At each inspection, rotate the wheel by hand ten to fifteen revolutions to distribute lubricant in motor and bearings. If paint deterioration begins, consideration should be given to touch-up or repainting. Fans with special coatings may require special techniques for touch-up or repair.
Machined parts coated with rust preventive should be restored to good condition promptly if signs of rust occur. Immediately remove the original rust preventive coating with petroleum solvent and clean with lint­free cloths. Polish any remaining rust from surface with crocus cloth or fine emery paper and oil. Do not destroy the continuity of the surfaces. Thoroughly wipe clean with Tectyl® 506 (Ashland Inc.) or the equivalent. For hard to reach internal surfaces or for occasional use, consider using Tectyl® 511M Rust Preventive, WD-40® or the equivalent.
Removing From Storage
As fans are removed from storage to be installed in their final location, they should be protected and maintained in a similar fashion until the fan equipment goes into operation.
Centrifugal Utility Fans 3
Page 4
Installation
Inspect the unit for any damage and report it to the shipper immediately. Also, check to see that all accessory items are accounted for.
Move the fan to the desired location and fasten securely through mounting holes provided in the base angles. The unit must be set level (shimming may be necessary). Flexible duct connections and vibration isolators should be used where noise is a factor.
The motor voltage and ampere rating must be checked for compatibility with the electrical supply prior to final electrical connection. Supply wiring to the fan must be properly fused, and conform to local and national electrical codes.
The discharge is factory set as specified by customer order, however, it can be rotated to other discharge positions in the field if necessary. Removal of the housing bolts allows the discharge to be rotated to the clockwise positions below. For TAD, DB and BAD discharge positions, a portion of the frame angle must be removed.
Clockwise rotation shown. Counterclockwise discharge positions are a mirror image of those shown. Fan rotation is always specified from the drive side of the housing.
Discharge Positions
Installation of UL/cUL 762 Listed Fans for Restaurant Exhaust
The UL/cUL 762 listing for restaurant exhaust is available on model XUEB Series 200, sizes 206 - 224, with a weatherhood.
UL/cUL 762 fans are listed for a maximum operating temperature of 375°F door and 1inch
(191°C)
(25.4mm)
outlet guard is strongly recommended when the fan discharge is accessible. An upblast discharge is recommended. The fan discharge must be a minimum of 40 inches
(1016 mm)
exhaust duct must be fully welded to a distance of 18inches
40 in.**
(1016 mm)
**Per NFPA 96 the fan discharge must be a minimum of 40 in. (1016 mm) above the roof surface.
This drawing is for dimensional information only. See the latest edition of NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations for detailed installation instructions, materials, duct connections and clearances.
(457mm)
Upblast Discharge
Weatherhood
above the roof surface.
and includes an access
drain connection. An
above the roof line and the
XUEB Series 200 models are listed for grease removal (UL/cUL 762) File no. MH11745
Optional Companion Flange
3 Wheel
Diameters
Duct from
kitchen
hood
18 in.*
(457 mm)
*Per NFPA 96 the duct must be of all-welded construction to a minimum distance of 18 inches (457 mm) above the roof surface.
CW BH CW BAU CW TAUCW UB
CW TH CW TAD
CW DB
CW BAD
Centrifugal Utility Fans4
Page 5
Effect of Installation on Performance
Restricted or unstable flow at the fan inlet can cause pre-rotation of incoming air or uneven loading of the fan wheel, yielding large system losses, increased sound levels and structural failure of the fan wheel. Free discharge or turbulent flow in the discharge ductwork will also result in system effect losses.
These examples show the system layout and inlet and discharge configurations which can affect fan performance.
7o MAX.
POOR
POOR
POOR
POOR
Turning
Varies
FAIR
POOR
FAIR
FAIR
One
Impeller
Dia.
GOOD
FAIR
Should be at least 1/2 Impeller Dia.
GOOD
GOOD
Pre-Starting Checks
DANGER
Always disconnect, lock and tag power source before installing or servicing. Failure to disconnect power source can result in fire, shock or serious injury.
CAUTION
When servicing the fan, motor may be hot enough to cause pain or injury. Allow motor to cool before servicing.
CAUTION
Precaution should be taken in explosive atmospheres.
DANGER
Pour écarter les risques d’incendie, de choc électrique ou de blessure grave, veiller à toujours débrancher, verrouiller et étiqueter la source de courant avant l’installation ou l’entretien.
ATTENTION
Lors de toute intervention sur la soufflante, le moteur peut être suffisamment chaud pour provoquer une douleur voire une blessure. Laisser le moteur refroidir avant toute maintenance.
ATTENTION
Faire preuve de précaution dans les atmosphères explosives.
Alignment of Pulleys and Belts
Check pulleys and belts for proper alignment to avoid unnecessary belt wear, noise, vibration and power loss. Motor and drive shafts must be parallel and pulleys in line as shown in Figure 1.
CORRECT WRONG WRONG WRONG
POOR
POOR
Not Greater than
o
60
Including Angle
FAIR
Figure 1
The adjustable motor pulley is set at the factory for the fan RPM specified by the customer. Fan RPM can be increased by closing or decreased by opening the adjustable motor pulley. Multigroove variable pitch pulleys must be adjusted an equal number of turns open or closed. Any increase in fan speed represents a substantial increase in load on the motor.
To avoid motor overheating and possible burnout, motor load amperes should always be checked and compared to nameplate rating when fan speed is increased.
Centrifugal Utility Fans 5
Page 6
R
o
t
a
t
i
o
n
R
o
t
a
t
i
o
n
R
o
ta
t
io
n
R
o
ta
t
io
n
Backward Inclined
Forward Curved
Airflow
Airflow
Backward Inclined Forward Curved
Airflow
These are the original drawings on the Illustrator file when I opened it. The IOM had the wheel layered on top of the scroll. I will incorporate the wheel on the scroll without creating an additional layer in the InDesign file.
R
o
t
a
t
i
o
n
R
o
t
a
t
i
o
n
Airflow
Airfoil
Wheels
Gap
Wheel
Radial Gap
Overlap
Wheel
Wheels must rotate freely and not rub on the inlet venturi. Model XUEB wheels overlap the inlet venturi as shown in Figure 2.
Refer to the Approximate Wheel Clearance Dimensions table for the proper dimensions for wheel overlap and radial gap.
Approximate Wheel Clearance Dimensions
(10)
(10)
(11)
(13)
(13)
(16)
(16)
(18)
(19)
Overlap
Tolerance
inches (mm)
1
4
1
4
1
4
1
4
1
4
3
(10)
8
3
(10)
8
3
(10)
8
3
(10)
8
XUEB
Series 100
XUEB
Series 200
Overlap
106 206 — 107 207 — 108 208
3
110 210
212 113 213 115 215 116 216 118 218 120 220
222 124 224
Method for Centering Wheel
On belt drive units, centering can be accomplished
8
3
8
7
16
1
2
1
2
5
8
5
8
11
16
3
4
by (a) loosening the inlet cone bolts to move the inlet cone or by (b) loosening the bearings in order to move the shaft. Wheel and inlet cone overlap can be adjusted by loosening the wheel hub set screws and moving the wheel to the desired position. For wheel hubs and shaft pulleys utilizing a tapered bushing interface, reference page 8 for the tapered bushing removal and move the wheel to the desired position. Tighten all fasteners and set screws securely and realign drive pulleys after adjustment.
(6)
(6)
(6)
(6)
(6)
Figure 2
Radial
Gap
5
(4)
32
5
(4)
32
5
(4)
32
5
(4)
32
5
(4)
32
5
(4)
32
5
(4)
32
5
(4)
32
5
(4)
32
Wheel Rotation
Rotation direction of the wheel is critical and incorrect rotation will result in reduced air performance, increased motor loading and possible motor burnout.
Check wheel rotation by momentarily energizing the unit and noting if rotation is in the same direction as the airflow at the outlet and conforms to the rotation decal affixed to the unit.
Wheels as viewed from the drive side:
n
o
i
t
a
t
o
R
Backward Inclined
Airflow
Centrifugal Utility Fans6
Page 7
Mounting for Severe Duty Installation
Isolator Anchoring
One fastener per isolator anchoring. Four isolators required.
1/2 inch (13 mm) - 13 Bolt
1/2 inch (13 mm) - 13 Bolt (Four Locations)
(Four Locations)
Equipment Support Anchoring
Two fasteners per equipment support. Three supports required for model sizes 20 and larger.
5/8 inch (16 mm) Lag Screw
5/8 inch (16 mm) Lag Screw Min. 1-1/2 inch (38 mm) Thread Engagement
Min. 1-1/2 inch (38 mm) Thread Engagement (Two per Equipment Support)
(Two per Equipment Support)
18 Ga. Galvanized G90 with Wood Nailer
Three Supports Required for Sizes 20 and larger
Min. 5 inch
(127 mm)
Isolator Anchoring
3/8 inch (10 mm) S.S. Hilti Kwik Bolt
3/8 inch (10 mm) S.S. Hilti Kwik Bolt Three Expansion Anchors
Three Expansion Anchors Min. 2-1/2 inch (64 mm) Engagement
Min. 2-1/2 inch (64 mm) Engagement
2000 Min. PSI Concrete
Concrete
Deck Anchoring
5/16 inch (8 mm) Self-Drilling Screw Min. 1/2 inch (13 mm) of Threads Through
Steel
Deck Anchoring
Roof Truss 1/8 inch (3 mm) Thick or 12 Gauge Min.
Wood Timber Min. 4 inch (102 mm) Min. G = 0.42
Equipment Support Anchoring
7/16 inch (11 mm) Lag Bolt Min. 3-1/4 inch (83 mm) Thread Engagement
Timber Anchoring
Centrifugal Utility Fans 7
Page 8
Maintenance
Bushing
Washers
Cap Screws
Hub
Tapered Bushing Hub Installation and Removal
For wheel hubs and shaft pulleys utilizing a tapered bushing interface, follow this procedure for installation and removal. There are two possible set ups for the tapered bushing, both have the same procedure, but orientation of the hub varies.
Tapered Bushing Removal:
1. If present, loosen the setscrew holding the bushing and shaft key in place.
2. Loosen and remove the socket head cap screws which fasten the bushing to the hub as shown in the section views and examples of Figures 3-6.
Standard Mounting Reverse Mounting
Figure 3 Figure 4
Bushing
Hub
Washers
Cap Screws
Hub
Bushing
Washers
Cap Screws
3. Standard Mounting - Take the two socket head cap screws that were removed and install them into the visibly threaded holes on the wheel hub. Reverse Mounting - Install the two socket head cap screws into the visibly threaded holes of the bushing flange.
4. Once both socket head cap screws are installed, tighten them an eighth of a turn at a time, alternating between the two until the hub comes loose from the bushing.
Bushing Installation:
1. Clean all surfaces of hub and bushing to remove any oil or residue present and do not use any lubricant to install bushing into the hub. For both standard and reverse mounting styles, the socket head cap screws are adjustable from the inlet of the fan.
2. Standard Mounting: Slide the bushing and shaft key onto the fan shaft followed by the wheel and hub assembly. If present, use the keyway setscrew to hold the shaft key and bushing in place but DO NOT overtighten as this can damage the bushing. Align the unthreaded holes of the hub with the threaded holes of the tapered bushing. Reverse Mounting: Slide the wheel and hub assembly onto the fans shaft followed by the bushing and shaft key. If present, use the keyway setscrew to hold the shaft key and bushing in place but DO NOT overtighten as this can damage the bushing. Align the unthreaded holes of the tapered bushing with the threaded holes of the hub.
3. Install the two bushing socket head cap screws into the aligned holes by hand (or without excessive torque) until the heads of the socket head cap screws are seated against the mating surface.
4. Adjust the height of the wheel in the fan relative to the inlet venturi then tighten the two socket head cap screws an eighth turn at a time in an alternating fashion and to a torque of 10 ft-lbs.
Figure 5
Standard Bushing Orientation
Centrifugal Utility Fans8
Figure 6
Reverse Bushing Orientation
Page 9
Bearing Lubrication Schedule
Shaft bearings are the most critical moving part of a fan. Therefore, special attention should be given to keeping the bearings clean and well lubricated. Proper lubrication provides for reduction in friction and wear, transmission and dissipation of heat, extended bearing life and prevention of rust.
In order for a lubricant to fulfill these tasks, the proper grease applied at regular intervals is required. See the recommended bearing lubrication schedule below.
If unusual conditions exist (temperatures below 32°F or above 200°F), moisture or contaminants - more frequent lubrication is required.
Recommended Bearing Lubrication Schedule
Fan
RPM
To 250 12 12 12 12 12
500 12 12 11 10 8
750 12 9 8 7 6 1000 12 7 6 5 4 1250 12 6 5 4 3 1500 12 5 4 3 2 2000 12 3 3 2 1 2500 12 2 2 1 0.5 3000 12 2 1 0.5 0.25 3500 12 1 0.5 0.25 ­4000 12 0.5 0.25 - ­5000 12 0.25 - - -
Number of Shots
Lubrication interval is based on 12 hour per day
operation and maximum 160°F housing temperature. For 24 hour per day operation, the interval should be cut in half.
• Lubricant should be added with the shaft rotating and until clean grease is seen purging from the bearing. The lubrication interval may be modified based on the condition of the purged grease. If bearing is not visible to observe purged grease, lubricate with number of shots indicated in chart for bore size.
• For conditions including high temperatures, moisture, dirt or excessive vibration, consult the factory for a specific lubrication interval for your application.
• Lubricant should be a high quality lithium complex grease conforming to NLGI Grade 2. Factory recommends Mobilux EP-2.
• The use of synthetic lubricants will increase lubrication intervals by approximately 3 times.
In addition to lubricating the bearings at specified intervals, set screws in the bearing collars should be checked for tightness. A bearing collar which has loosened will cause premature failure of the fan shaft. Fasteners attaching the bearings to the drive frame should also be checked.
Relubrication Schedule in Months
Standard Grease
Bearing Bore (inches)
1/2 -1 11⁄8 - 11⁄2 15⁄8 - 17⁄8 115⁄16 - 23⁄16 27⁄16 - 3
4 8 8 10 16
Motor Maintenance
Motor maintenance is generally limited to cleaning and lubrication (where applicable). Cleaning should be limited to exterior surfaces only. Removing dust and grease buildup on the motor housing assures proper motor cooling. Use caution and do not allow water or solvents to enter the motor or bearings. Under no circumstances should motors or bearings be sprayed with steam, water or solvents.
Many fractional horsepower motors are permanently lubricated for life and require no further lubrication. Motors supplied with grease fittings should be greased in accordance with the manufacturer’s recommendations.
Wheel and Fastener Maintenance
Wheels require very little attention when exhausting clean air, however, air heavily laden with grease or dirt will tend to accumulate on the wheel causing unbalance. Wheels exhausting dirty or grease-laden air require frequent cleaning to assure smooth and safe operation.
All fasteners, including set screws in the bearing collars, should be checked for tightness each time maintenance checks are performed.
A proper maintenance program will help preserve the performance and reliability designed into the fan.
Belt Maintenance)
Belts tend to stretch after a period of time. They should be periodically checked for tension and wear. When replacing belts, use the same type as supplied with the unit. Replacement of belts should be accomplished by loosening the tensioning “L-Bolts” so the belts may be removed by hand. Do not force belts on or off as this may cause breakage of cords and lead to premature belt failure.
Belt tension should be adjusted to allow 1/64 in. of belt deflection per 1 in. of belt span. For example, a 16 in. belt span should have 16/64 in. or 1/4 in. of deflection with moderate thumb pressure at mid-point between the pulleys. (Figure 7).
Belt Span
Belt Span
Figure 7
Deflection =
64
Centrifugal Utility Fans 9
Page 10
Motor and Drive Installation Instructions
For model XUEB units that are shipped from stock without motors or drives.
1. Adjust motor pulley to its closed position for maximum fan speed or increments of 1/2 turn open (maximum of 5 turns open) for reduced fan speed. Tighten set screw on flat area only.
4. Install shaft pulley to fan shaft.
2. Install motor pulley to the motor shaft and install motor to the motor plate. Pre-punched holes are provided for most common motor frame sizes.
3. If supplied, install taperlock bushing into shaft pulley.
Centrifugal Utility Fans10
5. Install drive belt(s). Belts should not be forced over pulleys. Align motor and shaft pulleys. Tighten all set screws.
6. Adjust belt tension. See page 9 for belt tensioning instructions.
Page 11
Parts List
Each fan bears a manufacturer’s nameplate with model number and serial number embossed. This information will assist the local Accurex representative and the factory in providing service and replacement parts. Before taking any corrective action, make certain unit is not capable of operation during repairs.
CAUTION
A fan manufactured with an explosion resistant motor does not certify the entire unit to be explosion proof. Refer to ULListing Mark for the fans approved usage.
7
8
9
10
14
CAUTION
La présence d’un moteur antidéflagrant sur un ventilateur ne garantit pas que tout l’appareil est antidéflagrant. Pour connaître les emplois autorisés de l’appareil, voir son marquage de conformité UL.
1
5
6
4
11
13
12
Available Replacement Parts:
1. Scroll housing
2. Drive frame - base angle
3. Intake support panel
4. Inlet ring and cone
5. Wheel (specify rotation)
6. Drive frame assembly
7. Pillow block bearings
2
3
8. Fan shaft
9. Shaft pulley
10. Belt
11. Motor pulley
12. Belt tensioning bolts
13. Motor plate
14. Motor
Centrifugal Utility Fans 11
Page 12
Troubleshooting
WARNING
Before taking any corrective action, make certain unit is not capable of operation during repairs.
Avant d’entreprendre toute action corrective, s’assurer que l’appareil ne pourra pas fonctionner
AVERTISSEMENT
durant les réparations.
PROBLEM CAUSE CORRECTIVE ACTION
Adjust wheel and/or inlet cone. Tighten wheel hub or bearing collars on shaft. Tighten sheaves on motor/fan shaft. Adjust belt tension. Align sheaves properly (see page 5). Replace worn belts or sheaves. Replace defective bearing(s). Lubricate bearings. Tighten collars and fasteners. Clean all dirt off wheel. Check wheel balance, rebalance in place if necessary.
Excessive Noise
Low CFM
Wheel Rubbing Inlet
V-Belt Drive
Bearings
Wheel Unbalance
Fan Check wheel for correct rotation. Increase fan speed.* Duct System See page 5, Effect of Installation on Performance Fan Resize ductwork. Access door, filters, grills not installed.
High CFM
Duct System
Change obstructions in system. Use correction factor to adjust for temperature/altitude. Resize ductwork. Clean filters/coils. Change fan
speed.* Static Pressure Wrong
High Horsepower
Fan Doesn’t Operate
Duct system has more or less restriction than
Check rotation of wheel. Adjust fan speed.
anticipated Fan Check rotation of wheel. Reduce fan speed.
Duct System
Electrical Supply
Resize ductwork. Check proper operation of face and bypass dampers.
Check filters and access doors.
Check fuses. Check for circuit breakers in the off position. Check for
correct supply voltage.
Drive Check for broken belts. Tighten loose pulleys. Motor Assure motor is correct horsepower and not tripping overload protector.
Overheated Bearing
Lubrication Check for excessive or insufficient grease in the bearing.
Mechanical
Replace damaged bearing. Relieve excessive belt tension. Align
bearings. Check for bent shaft. * Always check motor amps and compare to nameplate rating. Excessive fan speed may overload the motor
and result in burnout.
Our Commitment
As a result of our commitment to continuous improvement, Accurex reserves the right to change specifications without notice.
Specific Accurex product warranties are located on accurex.com within the product area tabs and in the Library under Warranties.
P.O. Box 410 Schofield, WI 54476
Phone: 800.333.1400 • Fax: 715.241.6191
Parts: 800.355.5354 • www.accurex.com
12
470312 • XUEB, Rev. 10, July 2016 Copyright 2016 © Accurex, LLC12
Loading...