100A, 600Y/347V, 480V ∆ Thermal-magnetic
Dimensions 3P Fixed Version 5.12H x 3.00W x 2.76D
2.34 (Ibs)
Weight
T1
General
The T1 breaker family ranges from 15 through 100 amperes. The T1 trip units are non-interchangeable and use the very latest technology in electromagnetic relays for overcurrent trip protection. Thermal overload protection is provided by heat sensitive bimetals. Short circuit protection for the breaker is accomplished using a precise magnetic coil. State of the art construction in contacts and arcing chambers aid in limiting damaging fault currents through the protected circuits.
Standards
The UL489/CSA 22.2 version of T1 also carries an IEC-60947-2 rating.
Versions
The T1 frame is available in two versions: T = Thermal-magnetic, xed D = Molded case switch
Performance levels
The T1 breaker has two performance levels available: B = Basic single pole N = Normal three pole
Number of poles
The T1 molded case circuit breaker is available in single, three and four pole versions. Estimate 4 pole pricing by adding 35% to the 3 pole price and contact your ABB sales person for details.
Molded case switches
UL489 switches include no overcurrent protection except for a high instantaneous trip mechanism for self protection.
UL489 / CSA C22.2 Interrupting capacity (kA RMS)
240VAC 15 – 100A
347VAC
480VAC ∆
600Y/347VAC 15 – 100A 10
250VDC 2 pole series 15 – 100A 25
500VDC 3 pole series 15 – 100A 25
15A
20 – 100A
15A 2
20 – 100A
10 14
— —
50 1
— —
14 22
IEC 60947-2 Interrupting capacity (kA RMS)
230VAC 15 – 100A
415VAC 15 – 100A 36
690VAC 15 – 100A 6
500VDC 2 pole series 15 – 100A 36
25 3
50
16
1 In 15A 35kA @ 240VAC. 2 15A available in 480/277 VAC only. 3 Interrupting capacity for 16-20A is 16kA
Low Voltage Products & Systems 16.5
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202
T1
Tmax
MCCBs
T1B TMF — Single pole thermal magnetic xed 1
Breaker
277VAC trip catalog number price
10kA 15A 1000A T1B015TL-1 20A 1000A T1B020TL-1
25A 1000A T1B025TL-1 30A 1000A T1B030TL-1 $ 230 40A 1000A T1B040TL-1 T1B 18kA 50A 1500A T1B050TL-1 60A 1500A T1B060TL-1
70A 1500A T1B070TL-1 80A 1500A T1B080TL-1 90A 1500A T1B090TL-1 100A 1500A T1B100TL-1
T1N TMF — 3 pole thermal magnetic xed
Breaker
480VAC trip catalog number price
14kA 15A 1000A T1N015TL 2 20A 1000A T1N020TL
25A 1000A T1N025TL 30A 1000A T1N030TL 40A 1000A T1N040TL $ 402 T1N 22kA 50A 1500A T1N050TL 60A 1500A T1N060TL
70A 1500A T1N070TL 80A 1500A T1N080TL 90A 1500A T1N090TL 100A 1500A T1N100TL
IC at
IC at
100A, 600Y/347V, 480V ∆ Thermal-magnetic/Molded Case Switch
Rating
Rating
Magnetic 1 pole, 277VAC List
Magnetic 3 pole, 600Y/347VAC/500VDC List
262
479
T1N TMF — 100% Rated thermal-magnetic
16
Breaker
T1N 22kA
IC at
480VAC
14kA
Rating
15 1
20 1000A T1NQ020TL 25 1000A T1NQ025TL 30 1000A T1NQ030TL 40 1000A T1NQ040TL 50 1500A T1NQ050TL 60
70 80 1500A T1NQ080TL 90 1500A T1NQ090TL
100 1500A T1NQ100TL
Magnetic
trip
1000A T1NQ015TL
1500A T1NQ060TL 1500A T1NQ070TL
3 pole 600Y/347 500VDC
catalog number
T1N-D — Molded case switch
Breaker
capacity 3 trip catalog number price
T1-D 240V, 50kA 100A 1000A T1N100DL $ 431
Interrupting
Rating
Magnetic 480VAC/500VDC List
List
price
$ 442