ABB Starters General Product Line Information

Starters
Across the line Combination Reduced voltage
Starters
3
3
Low Voltage Products & Systems 3.1
ABB Inc. • 888-385-1221 • www.abb-control.com 1SXU 000 023 C0201
Starters
3
General information
Field modifi cation kits A Starters
Start-Stop pushbutton kit – dual element
Starter Catalog List size number price
3
A9 – A750 MPSSK $ 38 For fi eld installation on NEMA 1 enclosures. Kit includes one dual element
pushbutton and hardware.
Start-Stop pushbutton kit
Starter Catalog List size number price
A9 – A750 MP4SSK4 $ 48 For fi eld installation on all enclosures. Kit includes two momentary pushbuttons
and hardware. 1
Fwd-Rev-Stop pushbutton kit
Starter Catalog List size number price
A9 – A750 MPFRK-4 $ 120 For fi eld installation on all enclosures. Kit includes three momentary pushbuttons
and hardware. 1
2 Position selector switch kit
Starter Catalog List size number price
A9 – A750 MPSL2K-4 $ 90 For fi eld installation on all enclosures. Labels for ON-OFF are included. Kits
include mounting hardware. 1
3 Position selector switch kit
Starter Catalog List size number price
A9 – A750 MPSL3K-4 $ 90 For fi eld installation on all enclosures. Labels for HAND-OFF-AUTO are included.
Kits include mounting hardware. 1
Pilot light kits
Starter size number price
120 MPPLK-41 A9 – A750 240 MPPLK-42 $ 90 480V MPPLK-44
For fi eld installation on all enclosures. 1
Catalog List
Voltage
Reset button kits
Starter Catalog List size number price
A9 – A750 KPR3-104B $ 14 For fi eld installation on all enclosures. 1
1 For use with UL Type 3R, 4, 4X, 12 & 13.
3.2 Low Voltage Products & Systems
1SXU 000 023 C0201 ABB Inc. • 888-385-1221 • www.abb-control.com
Discount schedule FM
General information
Factory modifi cations
Starters
3
Control cover accessories – A9-A750
Control Description 1 NEMA 1 3R
4, 4X & 12
Start-stop pushbutton A $ 72 Fwd-rev-stop pushbutton B 360 2 position selector switch (Std. ON-OFF) C 72 3 position selector switch (Std. HAND-OFF-AUTO) D 72 Pilot light, Red, RUN (Std.) E 135 Pilot light, Green, RUN R 135 Pilot light suffi x + V= Neon bulb V Pilot light suffi x + X= LED bulb X Start-stop pushbutton & pilot light F 207 Fwd-rev-stop pushbutton & pilot light G 496 2 position selector switch & pilot light H 207 3 position selector switch & pilot light J 207 Fast-slow-stop pushbuttons K 360 Fast-slow-stop pushbuttons & pilot light L 495 Fast-slow-off-auto selector switch M 150 Emergency stop P 100 F suffi x + 1NO & 1NC auxiliary contact T 237 J suffi x + 1NO & 1NC auxiliary contact U 237 Pushbutton (standard START) Y 36
suffi x
List price
adder
Special modifi cations
Contact Suffi x List price confi guration code 1 adder
Contactor Coil surge suppressor S $ 75
Auxiliary relays
Type N control relay (4 pole) CR 225 Electronic timer
1.5 – 30, On Delay TN30 300 5 – 100, On Delay TN100 300
1.5 – 30, Off Delay TF30 300 5 – 100, Off Delay TF100 300 Phase failure phase reversal with over and undervoltage relays PFPR 525 Ground fault protection GFP 2250
For multi-speed controllers
Compelling relay CPR 600 Accelerating relay ACR 600 Decelerating relay DCR 600
Meters & metering
Current transformer CT 375 Ammeter (including C.T.) AM 705 Ammeter & ammeter switch AMS 1800 Voltmeter VM 1200 Voltmeter & voltmeter switch VMS 1800 Elapsed time meter ETM 375 Operation counter OC 560 Wattmeter WM 3650
Miscellaneous
Lightning arrestor LA 320 Space heater, 100W with thermostat SH 600
Control circuit transformer (standard VA) – A9 - A750 2
Primary Secondary Hz suffi x size VA price
A9 A40 45 A9 A40 50 360 200/208V 110V 50/60 0 A50 – A75 75 435 220/240V 110/120V 50/60 7 A95 – A110 100 560
440/480V 110/120V 50/60 8 A145 – A185 150 720 550/600V 110/120V 50/60 9 A210 – A300 250 795 A400 – A460 150 720 4
A580 – A750 250 795 4 Control circuit transformers do include two primary fuses and one secondary fuse.
1 Add this suffi x to the last digit of the catalog number. 2 Consult factory if additional VA is required. 3 Does not include primary fusing. 4 A400 - A750 utilizes the AF wide range coil with a lower coil consumption than A210 - A300.
Low Voltage Products & Systems 3.3
ABB Inc. • 888-385-1221 • www.abb-control.com 1SXU 000 023 C0201
Standard size with fused secondary
Coil Starter CCT List
Discount schedule – Always applied to the applicable starter discounts
Additional auxiliary contact blocks — A9 – A750
Suffi x A9 – A110 A145 – A750
1 N.O. 10 $ 20 1 N.C. 01 20 – 2 N.O. 20 30 – 1 N.O. & 1 N.C. 11 30 $ 30 2 N.C. 02 30 – 4 N.O. 40 60 – 3 N.O. & 1 N.C. 31 60 – 2 N.O. & 2 N.C. 22 60 60 1 N.O. & 3 N.C. 13 60 – 4 N.C. 04 60 – 3 N.O. & 3 N.C. 33 90 90
Contact
confi guration
code list price list price
1 adder adder
Reduced voltage & multi-speed starters — price adders
Non-fusible Fusible MCCB or Starter switch switch MCP size price price price adder adder adder
A9 $ 990 $ 1008 $ 1287 A12 990 1008 1287 A16 990 1008 1287 A26 990 1008 1287 A30 990 1224 1350 A40 990 1224 1350 A50 1152 1224 1350 A63 1230 1350 1785 A75 1494 1602 1809 A95 – A110 2310 2565 2982 A145 3042 3366 4158 A185 3300 3735 4533 A210 3450 3825 6000 A260 3744 4068 6849 A300 4200 6000 8750 A400 6600 9450 9030 A460 8200 11,100 9475 A580 8400 11,800 10,200 A750 9000 12,450 12,900
Hazardous location enclosure accessories, NEMA 7 & 9
3
$ 300
Catalog 1 No.
3R Breather/drain A $ 80 Start PB green B 180 Stop PB red C 180 St/St dual PB D 360 Em. Stop mush momentary E 220 Em. Stop mush maintained F 460 Black PB N.O. auxiliary G 180 Black PB N.C. auxiliary H 180 Pilot light J 180 Illuminated PB K 460 Push-to-test pilot light L 450 Potentiometer M 460 2-Pos Selector Maintained N 260 2-Pos Selector spring L to R P 280 2-Pos Selector spring R to L Q 280 3-Pos Selector sw. main. R 260 3-Pos Selector spring L to R S 280 3-Pos Selector spring R to L T 280 3-Pos Selector spring to C U 280 2-Pos Selector key operated V 450 3-Pos Selector key operated W 450
Suffi x
Item
List
price
3
Loading...
+ 7 hidden pages