ABB Starters Accessories Catalog

General information
Factory modifi cations
Starters
3
Control cover accessories – A9-A750
Control Description 1 NEMA 1 3R
4, 4X & 12
suffi x
List price
adder
Special modifi cations
Contact Suffi x List price confi guration code 1 adder
Contactor Coil surge suppressor S $ 75
Auxiliary relays
Type N control relay (4 pole) CR 225 Electronic timer
1.5 – 30, On Delay TN30 300 5 – 100, On Delay TN100 300
1.5 – 30, Off Delay TF30 300 5 – 100, Off Delay TF100 300 Phase failure phase reversal with over and undervoltage relays PFPR 525 Ground fault protection GFP 2250
For multi-speed controllers
Compelling relay CPR 600 Accelerating relay ACR 600 Decelerating relay DCR 600
Meters & metering
Current transformer CT 375 Ammeter (including C.T.) AM 705 Ammeter & ammeter switch AMS 1800 Voltmeter VM 1200 Voltmeter & voltmeter switch VMS 1800 Elapsed time meter ETM 375 Operation counter OC 560 Wattmeter WM 3650
Miscellaneous
Lightning arrestor LA 320 Space heater, 100W with thermostat SH 600
Control circuit transformer (standard VA) – A9 - A750 2
Primary Secondary Hz suffi x size VA price
A9 A40 45 A9 A40 50 360 200/208V 110V 50/60 0 A50 – A75 75 435 220/240V 110/120V 50/60 7 A95 – A110 100 560
440/480V 110/120V 50/60 8 A145 – A185 150 720 550/600V 110/120V 50/60 9 A210 – A300 250 795 A400 – A460 150 720 4
A580 – A750 250 795 4 Control circuit transformers do include two primary fuses and one secondary fuse.
1 Add this suffi x to the last digit of the catalog number. 2 Consult factory if additional VA is required. 3 Does not include primary fusing. 4 A400 - A750 utilizes the AF wide range coil with a lower coil consumption than A210 - A300.
Low Voltage Products & Systems 3.3
ABB Inc. • 888-385-1221 • www.abb-control.com 1SXU 000 023 C0201
Standard size with fused secondary
Coil Starter CCT List
Discount schedule – Always applied to the applicable starter discounts
Additional auxiliary contact blocks — A9 – A750
Suffi x A9 – A110 A145 – A750
1 N.O. 10 $ 20 1 N.C. 01 20 – 2 N.O. 20 30 – 1 N.O. & 1 N.C. 11 30 $ 30 2 N.C. 02 30 – 4 N.O. 40 60 – 3 N.O. & 1 N.C. 31 60 – 2 N.O. & 2 N.C. 22 60 60 1 N.O. & 3 N.C. 13 60 – 4 N.C. 04 60 – 3 N.O. & 3 N.C. 33 90 90
Contact
confi guration
code list price list price
1 adder adder
Reduced voltage & multi-speed startersprice adders
Non-fusible Fusible MCCB or Starter switch switch MCP size price price price adder adder adder
A9 $ 990 $ 1008 $ 1287 A12 990 1008 1287 A16 990 1008 1287 A26 990 1008 1287 A30 990 1224 1350 A40 990 1224 1350 A50 1152 1224 1350 A63 1230 1350 1785 A75 1494 1602 1809 A95 – A110 2310 2565 2982 A145 3042 3366 4158 A185 3300 3735 4533 A210 3450 3825 6000 A260 3744 4068 6849 A300 4200 6000 8750 A400 6600 9450 9030 A460 8200 11,100 9475 A580 8400 11,800 10,200 A750 9000 12,450 12,900
Hazardous location enclosure accessories, NEMA 7 & 9
3
$ 300
Catalog 1 No.
3R Breather/drain A $ 80 Start PB green B 180 Stop PB red C 180 St/St dual PB D 360 Em. Stop mush momentary E 220 Em. Stop mush maintained F 460 Black PB N.O. auxiliary G 180 Black PB N.C. auxiliary H 180 Pilot light J 180 Illuminated PB K 460 Push-to-test pilot light L 450 Potentiometer M 460 2-Pos Selector Maintained N 260 2-Pos Selector spring L to R P 280 2-Pos Selector spring R to L Q 280 3-Pos Selector sw. main. R 260 3-Pos Selector spring L to R S 280 3-Pos Selector spring R to L T 280 3-Pos Selector spring to C U 280 2-Pos Selector key operated V 450 3-Pos Selector key operated W 450
Suffi x
Item
List
price
3
1
Across the line
1
contactors
CAL5-11 CA5-10
Accessories
for A/AF/AL & AE contactors
Auxiliary contact blocks – Standard
Positioning
of contact blocks Description number price
4 blocks: A9 – A26 1 N.O. CA5-10 AE9 – AE26 1 N.C. CA5-01 Front mounting AL9 – AL26 (single pole) 5 blocks: A30, A40, AE30, AE40, AL30, AL40 1 N.O. Early make CC5-10 $ 15 6 blocks: A45 – A110 1 N.C. Late break CC5-01 AE45 - AE110 AF45 - AF110
Front mounting 1 block: (4 pole) 4 N.C. CA5-04E 2 N.O./2 N.C.
3 N.O. & 1 N.C. CA5-31M 1 block: A9 – A40-30-10 2 N.O. & 2 N.C. CA5-22M AL9 – AL40-30-10 1 N.O. & 3 N.C. CA5-13M 30 4 N.C. CA5-04M 4 N.O. CA5-40N 2 N.O./2 N.C.
2 blocks: A9 – A75, AE9-AE45 1 block: AE50 – AE75, AL9 – AL40
Side mounting 1 block: A/AE/AF95 - A/AE/AF110 1 N.O. & 1 N.C. CAL18-11 (2 pole)
2 blocks: A145 – A300, AF145-AF1650 1 N.O. & 1 N.C. (outside, L or R) CAL18-11B
Maximum number Contact Catalog List
A9 – A26-40-00 A30 – A110 AE9 – AE110
2 blocks: A145 – A300, AF145-AF1650 1 N.O. & 1 N.C. (inside L or R) CAL18-11
4 N.O. CA5-40E
3 N.O. & 1 N.C. CA5-31E
2 N.O. & 2 N.C. CA5-22E
1
CA5-11/11E
1
CA5-11/11M
1 N.O. & 1 N.C. CAL5-11
Auxiliary contact blocks – Front mounting, switching low voltage and low current
Positioning
of contact blocks Description protection number price
1 N.O. IP40 CE5-10D0.1 Front mounting AE9 – AE26 1 N.O. IP40 CE5-10D2
(single pole) AL9 – AL26 1 N.C. 5 blocks: A30, A40, AE30, AE40, AL30, AL40
6 blocks: A45 – A110 1 N.C. AE45 - AE110 1 N.O. AF45 - AF110 1 N.C.
Maximum number Contact Degree of Catalog List
4 blocks: A9 – A26 1 N.C. IP40 CE5-01D0.1
IP40 CE5-01D2
1 N.O. IP67 CE5-10W0.1
IP67 CE5-01W0.1 IP67 CE5-10W2
IP67 CE5-01W2
$ 38
42
1 Includes 1 N.O. & 1 N.C. overlapping
1.16 Low Voltage Products & Systems
1SXU 000 023 C0201 ABB Inc. • 888-385-1221 • www.abb-control.com
Discount schedule ABA
RV 5/50
RC 5-1/150
Across the line
Accessories
Surge suppressors for A/AE/AL/EK contactors
contactors
1
1
Surge suppression device
Mounting Voltage Catalog List on range number price
12 32 VDC RT5/32 25 65 VDC RT5/65 AE9 to AE110 50 – 90 VDC RT5/90 AL9 to AL40 77 – 150 VDC RT5/150 150 264 VDC RT5/264
24 50 VAC/VDC RV5/50 A9 to A110; AE9 to AE110 50 – 133 VAC/VDC RV5/133 AL9 to AL40 110 – 250 VAC/VDC RV5/250 250 440 VAC/VDC RV5/440 $ 30
24 50 VAC RC5-1/50 A9 to A40 50 – 133 VAC RC5-1/133 110 250 VAC RC5-1/250 250 440 VAC RC5-1/440
24 – 50 VAC RC5-2/50 A45 to A300 50 – 133 VAC RC5-2/133 110 250 VAC RC5-2/250 250 440 VAC RC5-2/440
EK110 to EK210 24 – 48 VAC RC-EH250/48 110 415 VAC RC-EH250/415
EK370 to EK550 48 – 110VAC RC-EH800/110 26 EK110 to EK550 24 – 125VDC RC-EH800/110 EK370 to EK550 220 – 600VAC RC-EH800/600
Technical data
Type Control Opening time Residual overvoltage Remarks circuit growth factor or clipping voltage
RT 5 /... transil diode Advantages • Good energy absorption 32 DC 50 V • Unpolarized system 65 DC 100 V • Simple, reliable system 90 DC 2.5 to 3 150 V Drawback • A certain delay on drop out which does not 150 DC 210 V 264 DC 390 V
Varistor RV 5/... 50 AC/DC 132 V • Unpolarized system
133 AC/DC 1.1 to 1.5 270 V
250 AC/DC 480 V Drawback • Clipping as from U 440 AC/DC 825 V this point
RC 5-1/... or RC 5-2/... see table AC Advantages • Very fast clipping RC-EH 300/...
• No operating delays Varistor + RC RC-EH ... Advantages • High energy absorption: good damping
800/110 AC/DC 800/600 AC 1100 V • The RC system damps the voltage
*Uvdr = Varistor operating voltage
Advantages • High energy absorption; good damping
above
1.2 to 3 2 to 3 x Uc • Attenuation of steep fronts and thus of
205 V • Unpolarized system
1.1 to 1.5
(voltage dependent resistor), tolerance ± 10%
however reduce contactor breaking capacity.
, thus voltage front up to
vdr
high frequencies
front under the Uvdr* threshold.
Low Voltage Products & Systems 1.21