Package Level 1 Gross Weight:
Rated Operational Voltage:
Rated Impulse Withstand Voltage
(U
imp
):
Rated Insulation Voltage (Ui):
Number of Main Contacts NC:
Number of Main Contacts NO:
Rated Operational Current AC-1 (Ie):
Rated Operational Power AC-3 (Pe):
Rated Short-time Withstand Current
(Icw):
Number of Auxiliary Contacts NC:
Number of Auxiliary Contacts NO:
B7-40-00-85 Mini Contactor 380-415V 40-450Hz
The B7-40-00 mini contactor is a compact 4 pole contactor with screw terminals. They are
ideally suited for applications where reliability is a must and space is at a premium. Mini
contactors are used in residential buldings, commercial buildings and industrial applications
for the control of single or three-phase loads up to 5.5 kW (AC-3) and 20 A / 690 V (AC-1) or
switching of control signals. Further features are the silent coil, a switch position indication
and the integrated possibility for rail or wall mounting.
Products » Low Voltage Products and Systems » Control Products » Contactors » Mini Contactors
Main Circuit 12 ... 690 V AC/DC
Main Circuit 690 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit DC
690 V
acc. to UL/CSA 600 V
(220 / 240 V) 40 °C 20 A
(220 / 240 V) 55 °C 16 A
(380 / 440 V) 40 °C 20 A
(380 / 440 V) 55 °C 16 A
(690 V) 40 °C 6 A
(690 V) 55 °C 6 A
(220 / 230 / 240 V) 3 kW
(400 V) 5.5 kW
(400 V) Three Phase 5.5 kW
(440 V) 5.5 kW
(500 V) 5.5 kW
(690 V) 3 kW
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A
0
Conventional Free-air Thermal
Current (Ith):
Rated Control Circuit Voltage (Uc):
Minimum Switching Capacity:
Maximum Electrical Switching
Frequency:
Connecting Capacity Main Circuit:
Connecting Capacity Auxiliary
Circuit:
Connecting Capacity Control Circuit:
Maximum Operating Altitude
Permissible:
Resistance to Shock acc. to IEC
60068-2-27:
Resistance to Vibrations acc. to IEC
60068-2-6:
Full Load Amps Motor Use:
Horsepower Rating UL/CSA:
General Use Rating UL/CSA:
Connecting Capacity Main Circuit
UL/CSA:
Connecting Capacity Auxiliary
Circuit UL/CSA:
Tightening Torque UL/CSA:
Maximum Operating Voltage
UL/CSA:
Instructions and Manuals:
Main Circuit 20 A
380 ... 415 V AC
(acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Control Circuit Terminals IP20
Main Circuit Terminals IP20
AC-1 300 cycles per hour
AC-15 360 cycles per hour
AC-3 600 cycles per hour
DC-1 600 cycles per hour
DC-13 360 cycles per hour
DC-3 600 cycles per hour
Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Control Circuit 0.8 ... 1.1 N·m
Main Circuit 0.8 ... 1.1 N·m
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
at Rated Operating Conditions per Pole 2 W
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
5g / 5 ... 150 Hz
Following EU Directive 2002/95/EC August 18, 2005 and amendment
Operation -25 ... +55 °C
Storage -40 ... +80 °C
(240 V AC) Single Phase 10 A
(440 ... 480 V AC) Three Phase 7.6 A
(208 V AC) Three Phase 3 Hp
(220 ... 240 V AC) Single Phase 1.5 Hp
(220 ... 240 V AC) Three Phase 3 Hp
(440 ... 480 V AC) Three Phase 5 Hp
(550 ... 600 V AC) Three Phase 5 Hp
Control Circuit 7 in·lb
Main Circuit 7 in·lb
Certificates and Declarations (Document Number)