ABB AF16-30-22, AF16Z-30-22 Catalog Page

Technical Datasheet 25/03/11
CE
cULus
CCC
GOST
C-Tick
1SBC101409D0201
AF16-30-22-.. / AF16Z-30-22-.. 2-stack 3-pole Contactors
AC / DC Operated - with Screw Terminals
AF16(Z) contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads.
AF..(Z) contactors include an electronic coil interface providing reduced – pull-in and holding consumption, particularly for AC control circuits Only four coils are needed to cover control voltages between 24...500 V – 50/60 Hz or 20...500 V DC. AF..(Z) offer extended operating limits and are suitable worldwide for different control voltages. e.g.: the coil 100...250 V 50/60 Hz - DC is suitable for Europe (230 V 50 Hz) and for North America (120 V 60 Hz and 208 V 60 Hz). AF..(Z) contactors can manage large control voltage variations AF..Z contactors equipped with a 24...60 V 50/60 Hz - 20...60 V DC coil – allow direct control by 24 V DC 500 mA PLC-output AF..Z contactors withstand short voltage dips and voltage sags (SEMI – F47-0706 compliance) AF..(Z) contactors have built-in surge protection and do not require – additional surge suppressors 2-stack contactors are mounted with a non-removable auxiliary contact – block. They have mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1, including the "Mechanically Linked" symbol on their side N.C. auxiliary contacts are mirror contacts in compliance with Annex F of – IEC 60947-4-1.
3D CAD outline drawings available on «Control Product 3D» portal
7.5 kW
10 hp
Ordering Details
power
400 V AC-3 480 V 1 piece
kW hp V 50/60 Hz V DC
3-phase motor rating
Uc min. ... Uc max.
contacts
Auxiliary contacts fitted
Type Order code EAN Weight
(ing)
Pack
kg
2-stack 3-pole Contactors
7.5 10 24...60 20...60 3 0 2 2
48...130 48...130 3 0 2 2
100...250 100...250 3 0 2 2
250...500 250...500 3 0 2 2
Note: AF16-30-22-11 not suitable for a direct control by PLC-output. AF16-30-22-11 available in some countries: please consult your ABB representative.
AF16-30-22-11 1SBL 177 001 R1122 AF16-30-22-12 1SBL 177 001 R1222 AF16-30-22-13 1SBL 177 001 R1322 AF16-30-22-14 1SBL 177 001 R1422
3471523110816 0.320 3471523110823 0.320 3471523110830 0.320 3471523110847 0.360
2-stack 3-pole Contactors - Low Consumption
7.5 10 - 12...20 3 0 2 2
24...60 20...60 3 0 2 2
48...130 48...130 3 0 2 2
100...250 100...250 3 0 2 2
Note: Only AF..Z contactors with DC control voltage 12...20 V DC need to respect the connection polarities indicated close to the coil terminals: A1+ for the positive pole and A2- for the negative pole
AF16Z-30-22-20 1SBL 176 001 R2022 AF16Z-30-22-21 1SBL 176 001 R2122 AF16Z-30-22-22 1SBL 176 001 R2222 AF16Z-30-22-23 1SBL 176 001 R2322
3471523114005 0.360 3471523114012 0.360 3471523114029 0.360 3471523114036 0.360
Certifications and Approvals
ABB | Technical Datasheet 1SBC101409D0201 1
2 Technical Datasheet 1SBC101409D0201 | ABB
Main Pole - Utilization Characteristics according to IEC
M
3
M
3
Standards IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 Rated operational voltage Ue max. 690 V Rated frequency limits 25 ... 400 Hz Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C
with conductor cross-sectional area 6 mm²
AC-1 Utilization category
for air temperature close to contactor
Ie / AC-1 rated operational current
Ue max. ≤ 690 V, 50/60 Hz
θ ≤ 40 °C θ ≤ 60 °C θ ≤ 70 °C
with conductor cross-sectional area 6 mm²
AC-3 Utilization category
for air temperature close to contactor θ ≤ 60 °C
(for 1500 r.p.m., 50 Hz or 1800 r.p.m., 60 Hz, 3-phase motors)
Ie / AC-3 max. rated operational current
3-phase motors
AC-3 rated operational power
1500 r.p.m. 50 Hz 1800 r.p.m. 60 Hz 3-phase motors
220-230-240 V
380-400 V
220-230-240 V
380-400 V
Rated making capacity AC-3 10 x Ie AC-3 acc. to IEC 60947-4-1 Rated breaking capacity AC-3 8 x Ie AC-3 acc. to IEC 60947-4-1 AC-8a Utilization category
(without thermal overload relay - Ue 400 V - θ ≤ 40 °C)
Ie / AC-8a rated operational current 22 A AC-8a rated operational power 11 kW
Short-circuit protection for contactors
without thermal O/L relay - Motor protection excluded
Ue ≤ 500 V AC - gG type fuse
Rated short-time withstand current Icw
at 40 °C ambient temperature, in free air from a cold state
Maximum breaking capacity
cos φ = 0.45
Heat dissipation per pole
at 440 V
at 690 V Ie / AC-1 Ie / AC-3
Max. electrical switching frequency
AC-2, AC-4
415 V 440 V 500 V 690 V
415 V 440 V 500 V 690 V
1 s 10 s 30 s
1 min
15 min
AC-1 AC-3
35 A
30 A 30 A 26 A
18 A 18 A 18 A 18 A 15 A
10.5 A 4 kW
7.5 kW 9 kW 9 kW 9 kW 9 kW
32 A 300 A 150 A 80 A 60 A 35 A 250 A 106 A
1.2 W
0.35 W 600 cycles/h 1200 cycles/h 300 cycles/h
ABB | Technical Datasheet 1SBC101409D0201 3
Built-in Auxiliary Contacts according to IEC
Rated operational voltage Ue max. 690 V Conventional free air thermal current Ith - θ ≤ 40 °C 16 A Rated frequency limits 25 ... 400 Hz Rated operational current Ie / AC-15
acc. to IEC 60947-5-1
Making capacity AC-15 10 x Ie AC-15 acc. to IEC 60947-5-1 Breaking capacity AC-15 10 x Ie AC-15 acc. to IEC 60947-5-1 Rated operational current Ie / DC-13
acc. to IEC 60947-5-1
Short-circuit protection gG type fuse 10 A Rated short-time withstand current Icw
Minimum switching capacity 12 V / 3 mA
with failure rate acc. to IEC 60947-5-4
Non-overlapping time between N.O. and N.C. contacts ≥ 2 ms Heat dissipation per pole at 6 A 0.1 W Max. electrical switching frequency
24-127 V 50/60 Hz 220-240 V 50/60 Hz 400-440 V 50/60 Hz
500 V 50/60 Hz 690 V 50/60 Hz
24 V DC 48 V DC
72 V DC 110 V DC 125 V DC 220 V DC 250 V DC 400 V DC 500 V DC 600 V DC
for 1.0 s
for 0.1 s
AC-15 DC-13
6 A 4 A 3 A 2 A 2 A
6 A / 144 W
2.8 A / 134 W 1 A / 72 W
0.55 A / 60 W
0.55 A / 69 W
0.27 A / 60 W
0.27 A / 68 W
0.15 A / 60 W
0.13 A / 65 W
0.1 A / 60 W
100 A 140 A
-7
10
1200 cycles/h 900 cycles/h
Main Pole - Utilization Characteristics according to UL / NEMA / CSA
Standards UL 508, CSA C22.2 N°14 Rated operational voltage Ue max. 600 V NEMA size ­NEMA continuous amp rating NEMA maximum H.P. ratings 1-phase, 60 Hz
NEMA maximum H.P. ratings 3-phase, 60 Hz
UL General use rating
600 V AC 30 A With conductor cross-sectional area AWG 10 80 V DC - 1-pole 30 A With conductor cross-sectional area AWG 10
UL maximum 1-phase motor rating
Amp-rating
Motor power
UL maximum 3-phase motor rating
Amp-rating
Motor power
(for 1500 r.p.m., 50 Hz or 1800 r.p.m., 60 Hz 3-phase motors)
Short-circuit protection
for contactors without thermal O/L relay - Motor protection excluded
Fuse rating 60 A Fuse type, 600 V NTD
Max. electrical switching frequency
for general use 600 cycles/h for motor use 1200 cycles/h
thermal current
115 V AC 230 V AC 200 V AC 230 V AC 460 V AC 575 V AC
120 V AC 240 V AC 120 V AC 240 V AC
200-208 V AC 220-240 V AC 440-480 V AC 550-600 V AC 200-208 V AC 220-240 V AC 440-480 V AC 550-600 V AC
20 A 17 A 1-1/2 hp 3 hp
17.5 A
15.2 A 14 A 17 A 5 hp 5 hp 10 hp 15 hp
Loading...
+ 5 hidden pages