A9 – AF1650
Non-reversing, mechanically interlocked, reversing
NEMA rated, AC operated, 3 phase
A26N1-30-10-84 A145N4-30-11-84 AF400N6-30-11-70
Across the line
contactors
1
1
NEMA Continuous
size current
00 9 1.5 1.5 2 1 0 A9N00-30-10-84 $ 78 A9N00M-10-84 $ 255 A9N00R-10-84 $ 315
0 18 3 3 5 1 0 A16N0-30-10-84 102 A16N0M-10-84 345 A16N0R-10-84 413
1 27 7.5 7.5 10 1 0 A26N1-30-10-84 183 A26N1M-10-84 405 A26N1R-10-84 480
2 45 10 15 25 1 1 A50N2-30-11-84 330 A50N2M-11-84 713 A50N2R-11-84 810
3 90 25 30 50 1 1 A75N3-30-11-84 413 A75N3M-11-84 1155 A75N3R-11-84 1298
4 135 40 50 100 1 1 A145N4-30-11-84 825 A145N4M-11-84 2235 A145N4R-11-84 2250
5 270 75 100 200 1 1 A260N5-30-11-84 1815 A260N5M-11-84 4485 A260N5R-11-84 4500
6 540 150 200 400 1 1 AF460N6-3011-70 4425 AF460N6M-11-70 13,275 AF460N6R-11-70 13,290
7 810 — 300 600 1 1 AF750N7-3011-70 7200 AF750N7M-11-70 19,725 AF750N7R-11-70 19,740
8 1215 — 450 900 1 1 AF1650N83011-70 10,230 — — — —
Maximum motor Standard
horsepower ratings
200V 230V 460/575V NO NC
number price number price number price
Coil voltage selection – A contactors
All AC operated catalog numbers include a 120VAC coil. To select other coil
voltages, substitute the code from the Coil Voltage Selection Chart for the two
digits after the last dash in the catalog number.
Ex.: A 240V coil is required for an A75 contactor: A75-30-11-80
Coil voltage selection – wide range AC/DC coils
All catalog numbers include a 100-250V AC/DC coil. To select other coil voltages,
substitute the code from the Coil Voltage Selection Chart for the two digits after the
last dash in the catalog number.
Ex.: A 24V coil is required for a AF145 contactor: AF145N4-30-11-68
Auxiliary contact blocks
For additional auxiliary contact blocks, see catalog number explanation on page
1.2. Add $ 20 to list price for each additional auxiliary, and see page 1.18 for
available combinations.
Mechanical interlock
Mechanically interlocked contactors are designed for reversing, 2 speed, reduced
voltage, etc. type starter applications. The complete assembly consists of two
mechanically and electrically interlocked contactors mounted as follows with line
and load terminals:
• A9 - A16 — mounted on 35mm DIN rail
• A26 - A750 — mounted on common baseplate
Power wiring is not included.
For A9 - A110 contactors the NC electrical interlock is provided with the
mechanical interlock.
R
Aux. contacts Non-reversing Mechanically interlocked Reversing
Catalog List Catalog List Catalog List
NEMA rated
Reversing
Reversing contactors are designed for reversing type starter applications. The
complete assembly consists of two mechanically and electrically interlocked
contactors mounted as follows with line and load terminals:
• A9 - A16 — mounted on 35mm DIN rail
• A26 - A750 — mounted on common baseplate
For A9 - A750 contactors the NC electrical interlock is provided with the
mechanical interlock.
Coil voltage selection – A contactors
Cntr
Hz
type 12 24 48 110 120 125 208 220 240 277 380 415 440 480 500 600
60 A 81 83 84 84 34 36 80 42 86 86 51 53 55
50 A 81 83 84 80 85 86 55
For other voltages, see page 1.26.
Volts
Coil voltage selection – AF50 to AF1650
AC/DC VOLTS, 40 - 60 HZ
24 - 60 DC 20 - 60 DC 48 - 130 AC/DC 100 - 250 AC/DC
68 1 72 2 69 70
1 AF400 – AF750, DC only.
2 AF50 – AF300, DC only.
Low Voltage Products & Systems 1.11
ABB Inc. • 888-385-1221 • www.abb-control.com AC 1000 - 11/03
Discount schedule AA - A9 - A110
Discount schedule AEA - A145 - AF750