ABB A40, A50, A63, A75, A95 Technical Data

...
IEC Technical data
Across the line
1
Contactors
A/E/L40, A/E/F50...A/F110, 3-pole Utilization characteristics
Contactor types
AC operated DC operated
A40 A50 A63 A75 A95 A110 AL40 AE50 AE63 AE75 – TAL40 TAE50 TAE75
AC / DC operated
Standards Rated operational voltage Ue max. Rated frequency (without derating)
AF50 AF63 AF75 AF95 AF110
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 690 V 1000 V (690 V for AF.. contactors) 1000 V 50/60 Hz
Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C
65 A 100 A 125 A 125 A 145 A 160 A
With conductor cross-sectional area 16 mm² 35 mm² 50 mm² 50 mm² 50 mm² 70 mm²
AC-1 Utilization category
For air temperature close to contactor
Ie / Rated operational current AC-1
Ue max. ≤ 690 V, 50/60 Hz
θ ≤ 40 °C θ ≤ 55 °C
θ ≤ 70 °C (3)
60 A 100 A 115 A 125 A 145 A 160 A 60 A 85 A 95 A 105 A 135 A 145 A 42 A 70 A 80 A 85 A 115 A 130 A
With conductor cross-sectional area 16 mm² 35 mm² 50 mm² 50 mm² 50 mm² 70 mm²
AC-3 Utilization category
For air temperature close to contactor θ ≤ 55 °C
Ie / Max. rated operational current AC-3 (1)
220-230-240 V
380-400 V
M
3-phase motors
3
40 A 53 A 65 A 75 A 96 A 110 A 37 A 50 A 65 A 75 A 96 A 110 A
415 V
37 A 50 A 65 A 75 A 96 A 110 A
440 V
37 A 45 A 65 A 70 A 93 A 100 A
500 V
33 A 45 A 55 A 65 A 80 A 100 A
690 V
25 A (4) 35 A 43 A 46 A 65 A 82 A
1000 V
23 A (6) 25 A (6) 28 A (6) 30 A 30 A
Rated operational power AC-3 (1)
M
3
1500 r.p.m. 50 Hz 1800 r.p.m. 60 Hz 3-phase motors
Rated making capacity AC-3 Rated breaking capacity AC-3 AC-8a Utilization category
(without thermal overload relay - Ue 400 V 50/60 Hz - θ ≤ 40 °C)
Ie / Rated operational current AC-8a Rated operational power AC-8a
220-230-240 V
380-400 V
11 kW 15 kW 18.5 kW 22 kW 25 kW 30 kW
18.5 kW 22 kW 30 kW 37 kW 45 kW 55 kW
415 V
18.5 kW 25 kW 37 kW 40 kW 55 kW 59 kW
440 V
22 kW 25 kW 37 kW 40 kW 55 kW 59 kW
500 V
22 kW 30 kW 37 kW 45 kW 55 kW 59 kW
690 V
22 kW (4) 30 kW 37 kW 40 kW 55 kW 75 kW
1000 V
30 kW (6) 33 kW (6) 37 kW (6) 40 kW 40 kW 10 x Ie AC-3 acc. to IEC 60947-4-1 8 x Ie AC-3 acc. to IEC 60947-4-1
50 A 63 A 85 A 95 A 120 A 140 A 22 kW 30 kW 45 kW 45 kW 55 kW 75 kW
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded (2) Ue ≤ 500 V AC - gG type fuse
Rated short-time withstand current Icw
at 40 °C ambient temperature,
in free air from a cold state
63 A 100 A 125 A 160 A 160 A 200 A
1 s
600 A 1000 A 1320 A
10 s
400 A 650 A 800 A
30 s
225 A 370 A 500 A
1 min
150 A 250 A 350 A
15 min
65 A 110 A 135 A 135 A 160 A 175 A
Maximum breaking capacity
cos φ = 0.45 (cos φ = 0.35 for Ie > 100 A)
Power dissipation per pole
Max. electrical switching frequency
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see "Motor rated operational powers and currents". (2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices". (3) Unauthorized for TAL.., TAE.. contactors. (4) AC-3, 690 V values for AL40 and TAL40 contactors: 18.5 kW, Ie = 21 A. (5) Max. breaking capacity for AL40 and TAL40 contactors: 470 A at 440 V, 175 A at 690 V. (6) AF contactors excluded.
at 440 V
at 690 V Ie / AC-1 Ie / AC-3
AC-1 AC-3
AC-2, AC-4
820 A (5) 1300 A 1160 A 340 A (5) 630 A 800 A 3 W 5 W 6.5 W 7 W 6.5 W 7.5 W
1.3 W 1.3 W 1.5 W 2 W 2.7 W 3.6 W 600 cycles/h 600 cycles/h (300 for AF.., AE.., TAE..) 300 cycles/h 1200 cycles/h 600 cycles/h (300 for AF.., AE.., TAE..) 300 cycles/h 300 cycles/h 150 cycles/h
1.84 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
UL/NEMA/CSA Technical data
C1
Across the line
1
Contactors
Main pole - Utilization characteristics according to UL / NEMA / CSA
Contactor types
Standards Max. operational voltage NEMA size NEMA continuous amp rating NEMA maximum horse power ratings 1-phase, 60 Hz
NEMA maximum horse power ratings 3-phase, 60 Hz
UL / CSA general use rating
600 V AC 60 A 80 A 90 A 105 A 125 A 150 A With conductor cross-sectional area AWG 6 AWG 4 AWG 3 AWG 2 AWG 1 AWG 1/0
UL / CSA maximum 1-phase motor rating
Full load current
Horse power rating
UL / CSA maximum 3-phase motor rating
Full load current (1)
Horse power rating (1)
Max. electrical switching frequency
For general use 600 cycles/h 600 cycles/h (300 for AF.., AE..) 300 cycles/h For motor use 1200 cycles/h 600 cycles/h (300 for AF.., AE..) 300 cycles/h
(1) For the corresponding kW/A or hp/A values of 1500 r.p.m, 50 Hz or 1800 r.p.m, 60 Hz, 3-phase motors, see “Motor rated operational powers and currents”.
A/E/L40; A/E/F50...A/F110, A/E/F50N2...A/E/F75N3, 3-pole Utilization characteristics
AC operated DC operated
AC / DC operated
Thermal current
115 V AC 230 V AC
200 V AC 230 V AC 460 V AC 575 V AC
120 V AC 240 V AC 120 V AC 240 V AC
200-208 V AC 220-240 V AC 440-480 V AC 550-600 V AC 200-208 V AC 220-240 V AC 440-480 V AC 550-600 V AC
A40 A50 A63 A75 A95 A110 AL40, TAL40 AE50, TAE50 AE63 AE75, TAE75 – – AF50 AF63 AF75 AF95 AF110
UL 508, CSA C22.2 N°14 600 V
2 3 – – 45 A 90 A
3 hp – – 7-1/2
10 hp 25 hp – – 15 hp 30 hp – – 25 hp 50 hp – – 25 hp 50 hp
34 A 34 A 56 A 80 A 80 A 100 A 40 A 40 A 50 A 68 A 88 A 110 A 3 hp 3 hp 5 hp 7.5 hp 7.5 hp 10 hp
7.5 hp 7.5 hp 10 hp 15 hp 20 hp 25 hp
32.2 A 48.3 A 62.1 A 78.2 A 92 A 92 A 42 A 54 A 68 A 80 A 80 A 104 A 40 A 52 A 77 A 77 A 77 A 96 A 41 A 52 A 77 A 77 A 77 A 99 A 10 hp 15 hp 20 hp 25 hp 30 hp 30 hp 15 hp 20 hp 25 hp 30 hp 30 hp 40 hp 30 hp 40 hp 60 hp 60 hp 60 hp 75 hp 40 hp 50 hp 75 hp 75 hp 75 hp 100 hp
General technical data
Contactor types
Rated insulation voltage Ui
acc. to IEC 60947-4-1 1000 V acc. to UL 600 V
Rated impulse withstand voltage Uimp. Electromagnetic compatibility Ambient air temperature close to contactor
Operation Fitted with thermal overload relay -25...+55 °C
Without thermal overload relay -40…+70 °C (
Storage -60...+80 °C -40...+70 °C
Climatic withstand
Maximum operating altitude (without derating) Mechanical durability
Number of operating cycles 10 millions operating cycles (5 millions for AE.. and TAE..) Max. switching frequency 3600 cycles/h (300 for AF contactors)
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
A
(2) These values are not valid for rail mounting with contactors A95 ... A110 and AF95 ... AF110.
B1
A
B2
C2
AC operated DC operated
AC / DC operated
Shock direction
A B1 B2 C1 C2
A40 A50 A63 A75 A95 A110 AL40, TAL40 AE50, TAE50 AE63 AE75, TAE75 – – AF50 AF63 AF75 AF95 AF110
8 kV AF contactors complying with IEC 60947-1 / EN 60947-1 - Environment A
55 °C max. for TAL.., and TAE.. contactor
acc. to IEC 60068-2-30 and 60068-2-11
)
acc. to IEC 60068-2-30
UTE C 63-100 specification II 3000 m
1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position (2) 20 g 10 g closed position / 5 g open position
15 g
20 g 20 g
For AL40, TAL40 A : 20 g closed position / 10 g open position B1 : 15 g closed position / 5 g open position B2 : 10 g closed position / 10 g open position C1 : 20 g closed position / 8 g open position C2 : 14 g closed position / 8 g open position
1.88 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
General technical data
Pos
Across the line
1
Contactors
Magnet system characteristics
Contactor types Coil operating limits
acc. to IEC 60947-4-1
AC control voltage
50/60 Hz
DC control voltage
Drop-out voltage Voltage sag immunity
acc. to SEMI F47
Dips withstand Operating time
Between coil energization and:
Between coil de-energization and:
Rated control circuit voltage Uc 48…250 V 50/60 Hz Coil consumption
Rated control circuit voltage Uc 20…250 V DC Coil consumption
Mounting characteristics and conditions for use
Contactor types Mounting positions
AF50...AF110, 3-pole Coil & mounting characteristics
AC / DC operated
AC or DC supply
Average pull-in value
Average holding value
Average pull-in value
Average holding value
N.O. contact closing N.C. contact opening N.O. contact opening
N.C. contact closing
AC / DC operated
AF50 AF63 AF75 AF95 AF110
At θ ≤ 70 °C 0.85 x Uc min...1.1 x Uc max. Please also refer to "Mounting characteristics and conditions for use"
210 VA 350 VA 7 VA / 2.8 W 7 VA / 3.5 W
190 W 400 W
2.8 W 2 W 55 % of Uc min. Conditions of use on request
≥ 20 ms
30…100 ms 30…80 ms 27…95 ms 27…77 ms 30…110 ms 55…125 ms 35…115 ms 60…130 ms
AF50 AF63 AF75 AF95 AF110
. 2
+30° -30°
Control voltage / Ambient temperature
Mounting positions
Mounting distances Fixing
On rail according to IEC 60715, EN 60715 35 x 15 mm or 75 x 25 mm – By screws (not supplied) 2 x M6 screws placed diagonally
1, 1±30°, 2, 3, 4, 5 6 Unauthorized
at θ ≤ 70 °C
Pos. 4
Max. built-in and add-on N.O. or N.C. auxiliary contacts: see accessory fitting details for 3-pole contactor AF50 ... AF110
0.85 x Uc min…1.1 x Uc max.
The contactors can be assembled side by side
Pos. 1
Pos. 3
Pos. 1 ± 30°
Pos. 5
Pos. 6
1.94 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
Connecting characteristics
Contactor types
Main terminals
General technical data
A/E/L40, A/E/F50...A/F110, 3-pole
Terminal characteristics
AC operated DC operated
AC / DC operated
A40 A50 A63 A75 A95 A110 AL40 AE50 AE63 AE75 – TAL40 TAE50 TAE75 – – AF50 AF63 AF75 AF95 AF110
Across the line Contactors
1
Screw terminals with double connector
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid Solid (≤ 4 mm²)
Stranded (≥ 6 mm²)
Flexible with ferrule
Bars or lugs
L
l
Connection capacity acc. to UL/CSA (solid/stranded) Tightening torque Recommended 2.30 Nm / 20 lb.in 4.00 Nm / 35 lb.in 8 Nm / 71 lb.in
Max. 2.60 Nm 4.50 Nm 9 Nm
Auxiliary conductors
(built-in auxiliary terminals + coil terminals)
Rigid solid
Flexible with ferrule
Lugs
L
l
Connection capacity acc. to UL/CSA (solid/stranded)
Tightening torque
Coil terminals Recommended 1.00 Nm / 9 lb.in
Max. 1.20 Nm
Built-in auxiliary terminals Recommended 1.00 Nm / 9 lb.in
Max. 1.20 Nm
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals IP20 IP10 Coil terminals IP20 Built-in auxiliary terminals IP20
Screw terminals
Main terminals M5 M6 M8
Coil terminals M3.5
Built-in auxiliary terminals M3.5
(1) A(F)95 / A(F)110: use exible without ferrule. (2) With LW110 enlargement piece, see “Accessories”.
Screwdriver type
Screwdriver type
Screwdriver type
2 x (5.6 x 6.5 mm)
1 x
2.5...16 mm² 6...50 mm² 10...95 mm²
2 x
2.5...16 mm² 6...25 mm² 6...35 mm²
1 x
2.5...10 mm² 6...35 mm² 10…70 mm² (1)
2 x
2.5...10 mm² 6...16 mm² 6…35 mm² (1)
L ≤
30 mm (2)
l >
6 mm
1 or 2 x
AWG 8…4 AWG 8…1 AWG 6…2/0
1 x
1…4 mm² 0.75…2.5 mm²
2 x
1…4 mm² 0.75…2.5 mm²
1 x
0.75…2.5 mm² 1…2.5 mm² 0.75…2.5 mm²
2 x
0.75…2.5 mm²
L ≤
8 mm
l >
3.7 mm
1 or 2 x
AWG 18...14
Delivered in open position, screws of unused terminals must be tightened
Flat Ø 6.5 / Pozidriv 2 Hexagon socket (s = 4 mm)
Flat Ø 5.5 / Pozidriv 2
Flat Ø 5.5 / Pozidriv 2 –
Screw terminals with single connector
(13 x 10 mm)
Screw terminals with single connector
(14 x 14 mm)
Low Voltage Products & Systems 1.99
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
IEC/UL/CSA Technical data
!
R6
R4
8
Across the line
1
Contactors
Contactor types
Standards Rated operational voltage Ue max. Rated frequency (without derating) Conventional free-air thermal current Ith
acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C
With conductor cross-sectional area 35 mm² 35 mm² 50 mm²
AC-1 Utilization category
For air temperature close to contactor
Ie / Rated operational current AC-1
Ue max. ≤ 690 V, 50/60 Hz
With conductor cross-sectional area 25 mm² 35 mm² 50 mm²
Short-circuit protection device for contactors
without thermal overload relay - Motor protection excluded Ue ≤ 500 V AC - gG type fuse
Rated short-time withstand current Icw
At 40 °C ambient temperature,
in free air from a cold state
Power dissipation per pole Max. electrical switching frequency
(1) Unauthorized for TAE.. contactors
A/E/F45...A/E/F75, 4-pole Utilization characteristics
AC operated DC operated
AC / DC operated
θ ≤ 40 °C θ ≤ 55 °C
θ ≤ 70 °C (1) 50 A 70 A 85 A
Ie / AC-1
A45 A50 A75 AE45 AE50 AE75 TAE45 TAE50 TAE75 AF45 AF50 AF75
IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 1000 V (690 V for AF.. contactors) 50 / 60 Hz
100 A 100 A 125 A
70 A 100 A 125 A 60 A 85 A 105 A
80 A 100 A 160 A
1 s
1000 A
10 s
650 A
30 s
370 A
1 min
250 A
15 min
110 A 110 A 135 A
2.5 W 5 W 7 W
AC-1
600 cycles/h (300 for AF.., AE.., TAE..)
Main pole - Utilization characteristics according to UL / CSA
Contactor types
Standards Max. operational voltage UL / CSA general use rating
600 V AC 65 A 80 A 105 A With conductor cross-sectional area AWG 6 AWG 4 AWG 2
Max. electrical switching frequency
For general use 600 cycles/h (300 for AF.., AE.. TAE..)
Remark for 4-pole contactors fitted with 2 N.O. + 2 N.C. main poles
7
R5
R3
1
These contactors are suitable for controlling 2 separate circuits, i.e. 2 loads with 2 separate supplies, or 1 circuit comprising 2 separate loads with a single supply (see diagrams below). When the contactor operates there is no mechanical overlapping between the N.O. poles and the N.C. poles: BREAK before MAKE.
Block diagrams
– Single supply and 2 separate loads – 2 separate supplies and 2 separate loads
A1
1
AC operated DC operated
A45 A50 A75 AE45 AE50 AE75 TAE45 TAE50 TAE75
AC / DC operated
AF45 AF50 AF75
UL 508, CSA C22.2 N°14
600 V
These contactors are not suitable for a reversing starter or for controlling a single load from 2 separate supplies.
Main
supply
Back-up
supply
7
R5
R3
1
R3
Supply
R5
7
A1
2
A2
Load
Load
R4
2
A2
Load
Load
8
R6
8
R6
R4
1.124 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
Magnet system characteristics
Pos
Contactor types Coil operating limits
acc. to IEC 60947-4-1
AC control voltage
50/60 Hz
DC control voltage
Drop-out voltage Voltage sag immunity
acc. to SEMI F47
Dips withstand Operating time
Between coil energization and:
Between coil de-energization and:
Rated control circuit voltage Uc 48…250 V Coil consumption
Rated control circuit voltage Uc 20…250 V DC Coil consumption
General technical data
AF45...AF75
Coil & mounting characteristics
AC / DC operated
AC or DC supply
Average pull-in value
Average holding value
Average pull-in value
Average holding value
N.O. contact closing N.C. contact opening N.O. contact opening
N.C. contact closing
AF45 AF50 AF75
At θ ≤ 70 °C 0.85 x Uc min...1.1 x Uc max. Please also refer to "Mounting characteristics and conditions for use"
210 VA 7 VA / 2.8 W
190 W
2.8 W 55 % of Uc min.
Conditions of use on request
≥ 20 ms
30…100 ms 27…95 ms 30…110 ms 35…115 ms
Across the line Contactors
1
Mounting characteristics and conditions for use
Contactor types Mounting positions
Control voltage / Ambient temperature
Mounting 1, 1±30°, 2, 3, 4, 5 positions 6 Unauthorized
Mounting distances Fixing
On rail according to IEC 60715, EN 60715 35 x 15 mm or 75 x 25 mm By screws (not supplied) 2 x M6 screws placed diagonally
AC / DC operated
at θ ≤ 70 °C
AF45 AF50 AF75
. 2
Pos. 4
Pos. 1
Pos. 5 unauthorized for AF45-22-00, AF75-22-00 contactors
Max. and add-on N.O. or N.C. auxiliary contacts: see accessory fitting details for 4-pole con­tactor AF45 ... AF110
0.85 x Uc min…1.1 x Uc max.
The contactors can be assembled side by side
Pos. 3
+30° -30°
Pos. 1 ± 30°
Pos. 5
Pos. 6
Low Voltage Products & Systems 1.129
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
General technical data
C1
Across the line
1
Contactors
General technical data
Contactor types
Rated insulation voltage Ui
acc. to IEC 60947-4-1 1000 V acc. to UL / CSA 600 V
Rated impulse withstand voltage Uimp. Electromagnetic compatibility Ambient air temperature close to contactor
Operation -40...+70 °C (1) Storage -60...+80 °C
Climatic withstand Maximum operating altitude (without derating) Mechanical durability
Number of operating cycles 10 millions operating cycles (5 millions for AE... and TAE... contactors) Max. switching frequency 3600 cycles/h (300 for AF...)
Shock withstand
acc. to IEC 60068-2-27 and EN 60068-2-27
Mounting position 1
A
(1) 55 °C max. for TAE... contactors. (2) 3 g in open position for AF 45-22, AE 45-22, AF 75-22 and AE 75-22. (3) 10 g for AF 45-22, AE 45-22, AF 75-22 and AE 75-22.
B1
A
B2
C2
A/E/F45...A/E/F75, 4-pole
AC operated DC operated
AC / DC operated
Shock direction
4 N.O. Main poles
2 N.O. + 2 N.C. Main poles
A B1 B2 C1 C2
A B1 B2 C1 C2
A45 A50 A75 AE45 AE50 AE75 TAE45 TAE50 TAE75 AF45 AF50 AF75
8 kV AF contactors complying with IEC 60947-1 / EN 60947-1 - Environment A
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II 3000 m
1/2 sinusoidal shock for 11 ms: no change in contact position, closed or open position 20 g 10 g closed position / 5 g open position 15 g 20 g 20 g 20 g 10 g closed position / 5 g open position (2) 15 g (3) 20 g 20 g
1.132 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
General technical data
A/E/F45...A/E/F75
Terminal characteristics
Connecting characteristics
Contactor types
Main terminals
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid Solid (≤ 4 mm²)
Stranded (≥ 6 mm²)
Flexible with ferrule
Bars or lugs
L
l
Connection capacity acc. to UL/CSA (Sol/Str) Tightening torque Recommended 4.00 Nm / 35 lb.in
Max. 4.50 Nm
Auxiliary conductors
(built-in auxiliary terminals + coil terminals)
Rigid solid
Flexible with ferrule
Lugs
L
l
Connection capacity acc. to UL/CSA (Sol/Str) Tightening torque Recommended 1.00 Nm / 9 lb.in
Max. 1.20 Nm
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529
Main terminals IP10 Coil terminals IP20
Screw terminals
Main terminals M6
Coil terminals M3.5
AC operated DC operated
AC / DC operated
1 x 2 x 1 x 2 x L ≤
l >
1 or 2 x
1 x 2 x 1 x 2 x L ≤
l >
1 or 2 x
Screwdriver type
Screwdriver type
A45 A50 A75 AE45 AE50 AE75 TAE45 TAE50 TAE75 AF45 AF50 AF75
Screw terminals with single connector
(13 x 10 mm)
6…50 mm² 6…25 mm² 6…35 mm² 6…16 mm²
-
­AWG 8…1
1…4 mm² 1…4 mm² 1…2.5 mm²
0.75…2.5 mm² 8 mm
3.7 mm AWG 18…14
Delivered in open position, screws of unused terminals must be tightened
Flat Ø 6.5 / Pozidriv 2
Flat Ø 5.5 / Pozidriv 2
Across the line Contactors
1
Low Voltage Products & Systems 1.135
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A
IEC technical data
Across the line
1
Contactors
General
The arc switching on d.c. is more difcult than on a.c.
• For selecting a contactor it is essential to determine the current, the voltage and the L/R time constant of the controlled load.
• For information, typical time constant values are quoted hereafter: non-inductive loads such as resistance furnaces (L/R ~ 1 ms), inductive loads such as shunt motors (L/R ~ 2 ms) or series motors (L/R ~ 7.5 ms).
• The addition of a resistor in parallel with an inductive winding helps in the elimination of the arcs.
• All the poles required for breaking must be connected in series between the load and the source polarity not linked to earth (or chassis).
a.c. operated contactors A9 A12 A16 A26 A30 A40 A45 A50 A63 A75 GA75 a.c. / d.c. operated (electronic coil interface) AF45 AF50 AF63 AF75 – d.c. operated contactors AE9 AE12 AE16 AE26 AE30 AE40 AE45 AE50 AE63 AE75 GAE75
Utilization category DC-1, L/R < 1 ms
≤ 72 V A 25 27 30 45 55 60 70 100 110 120 120 110 V A 10 15 20 120 220 V A 120
440 V A – – – – – – – – – – 100
600 V A 75 ≤ 72 V A 25 27 30 45 55 60 70 100 110 120 110 V A 25 27 30 45 55 60 70 100 110 120 220 V A 10 15 20 ≤ 72 V A 25 27 30 45 55 60 70 100 110 120 110 V A 25 27 30 45 55 60 70 100 110 120 220 V A 25 27 30 45 55 60 70 100 110 120 ≤ 72 V A 25 27 30 45 70 100 120 110 V A 25 27 30 45 70 100 120 220 V A 25 27 30 45 70 100 120 440 V A 10 15 20
Utilization category DC-3, L/R < 2 ms
≤ 72 V A 25 27 30 45 55 60 70 100 110 120 120 110 V A 6 7 8 120 220 V A 100 440 V A 85 ≤ 72 V A 25 27 30 45 55 60 70 100 110 120 110 V A 25 27 30 45 55 60 70 100 110 120 220 V A 6 7 8 ≤ 72 V A 25 27 30 45 55 60 70 100 110 120 110 V A 25 27 30 45 55 60 70 100 110 120 220 V A 25 27 30 45 55 60 70 100 110 120 ≤ 72 V A 25 27 30 45 70 100 120 110 V A 25 27 30 45 70 100 120 220 V A 25 27 30 45 70 100 120 440 V A 6 7 8
Utilization category DC-5, L/R < 7.5 ms
≤ 72 V A 9 12 16 25 30 40 50 50 63 75 85 110 V A 4 4 4 85 220 V A 85 440 V A 35 ≤ 72 V A 25 27 30 45 55 60 70 100 110 120 110 V A 10 15 20 30 45 50 70 80 90 100 220 V A 4 4 4 ≤ 72 V A 25 27 30 45 55 60 70 100 110 120 110 V A 25 27 30 45 55 60 70 100 110 120 220 V A 9 12 16 25 30 40 50 50 63 75 ≤ 72 V A 25 27 30 45 70 100 120 110 V A 25 27 30 45 70 100 120 220 V A 10 15 20 30 70 70 100
440 V A 4 4 4 – – – – – – – –
A/E/L9...A/E/F75, GA/E75, 3 & 4-pole
DC Circuit switching
1.138 Low Voltage Products & Systems
1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage
Across the line
IEC Technical data
Contactors
A/F95...AF750, B/C6...B/C7, 3-pole
DC circuit switching
Technical Data
• The tables indicate for the standard contactors the Ie max. operating currents depending on: the utilization category (i.e. L/R) DC-1, DC-3, DC-5 as dened in the IEC 60947-4-1 publication, the operating voltage Ue and the pole coupling details. See page 1.81.
Ampere values quoted in the tables below are valid for a -25 … +70 °C temperature close to the contactors, as long as the AC-1 Ampere values (see pages 1.45 - 146)
for the corresponding ambient temperature are not exceeded.
• Max. switching frequency: 300 ops/h.
• For switching higher d.c. ratings, we recommend the use of bar mounted contactors, R series (63 … 2000 A).
The selection table for AE 50 ... AE 110 contactors can be used for the TAE 50 ... TAE 110 types.
a.c. operated contactors A95 A110 A145 A185 A210 A260 A300 – – a.c. / d.c. operated (electronic coil interface) AF95 AF110 AF145 AF185 AF210 AF260 AF300 AF400 AF460 AF580 AF750 d.c. operated contactors – – – – – – – – – – –
Utilization category DC-1, L/R < 1 ms
<110 V A 600 700 800 1050
<110 V A 145 160 250 275 350 400 450 600 700 800 1050
220 V A 600 700 800 1050 <110 V A 145 160 250 275 350 400 450 600 700 800 1050 220 V A 145 160 250 275 350 400 450 600 700 800 1050 440 V A 600 700 800 1050 600 V A 600 700 800 1050
Utilization category DC-3, L/R ≤ 2.5 ms
1
<110 V A 600 700 800 1050
<110 V A 145 160 250 275 350 400 450 600 700 800 1050
220 V A 600 700 800 1050 <110 V A 145 160 250 275 350 400 450 600 700 800 1050 220 V A 145 160 250 275 350 400 450 600 700 800 1050 440 V A 600 700 800 1050 600 V A 600 700 800 1050
Utilization category DC-5, L/R ≤ 15 ms
<110 V A 600 700 800 1050
<110 V A 145 160 250 275 350 400 450 600 700 800 1050
220 V A 600 700 800 1050 <110 V A 145 160 250 275 350 400 450 600 700 800 1050 220 V A 145 160 250 275 350 400 450 600 700 800 1050 440 V A 600 700 800 1050 600 V A 600 700 800 1050
D.C. Power circuit switching
Utilization category DC-1 DC-3 DC-5
L/ R ≤ 1 ms L/R ≤ 2 ms L/R ≤ 7.5 ms 24 V A
48 V A 16.0 8.0 2.0
60 V A 16.0 4.0 1.25 110 V A 7.0 1.5 0.4
220 V A 0.8 0.25 0.2 24 V A
48 V A 16.0 16.0 16.0
60 V A 16.0 15.0 12.0 110 V A 16.0 7.0 2.0
220 V A 5.0 1.5 0.5 24 V A
48 V A 16.0 16.0 16.0
60 V A 16.0 16.0 16.0 110 V A 16.0 15.0 8.0
220 V A 14.0 4.0 2.0
16.0 16.0 16.0
16.0 16.0 16.0
16.0 16.0 16.0
Low Voltage Products & Systems 1.139
ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 1SXU000023C0202 Rev. A