ABB 8037 Application Manual

Page 1
Application Guide
AG/AI–024_4
Cation Bed
Reduction of
positively
charged
solids
Anion
Exchange
Bed
Reduction of
negatively
charged
solids
Sodium Monitoring
in Water Treatment Processes
Mixed Bed
Further reduction of any remaining concentrations of
both positively and
negatively
charged dissolved
solids to produce pure
water
High Purity Water Out
Sample
to sodium Monitor
Raw
Water
In
The illustration above shows a simple demineralisation plant where anions are exchanged with hydroxyl ions and cations are exchanged with hydrogen ions
Sample
to sodium Monitor
8037 Sodium Monitor
Typical Range: 0.1ppb to 10ppm
Normal sodium concentration: 100ppb
(dependent upon type of exchange and raw water quality)
8037 Sodium Monitor
Typical Range: 0.01ppb to 1.0ppm
Normal sodium concentration: 1.0ppb
(by the use of ion exchange resins) to produce pure, mineral-free water. ABB sodium monitors are used for continuous monitoring of sodium in the process water.
Page 2
Sodium Monitoring in Water Treatment Processes
AG/AI-024_4

Why use Sodium Monitoring in Water Treatment Processes?

Why use a Sodium Monitor?

The customer needs:
To detect sodium breakthrough and to ensure the process water is pure.
To ensure the plant operates at the maximum efficiency.
To allow the plant to be maintained to specified standards.
Wide sample and ambient temperature tolerances as standard minimise the need for additional conditioning equipment.
The 8037 is a pumpless system which requires minimum maintenance.
Detachable cables ensure rapid electrode replacement.
Our system can use non-carcinogenic, non-pressurised ammonia reagent.
Sample driven 'entrainment' reagent addition removes:
the need for pumps or diffusion tubing,
the need for additional maintenance normally required by such
systems.
We supply full details of reagents to ensure the most cost-effective procurement options.
Our integral constant head design eliminates the effects of sample pressure and flow rate variations and minimises sample transport time.
Our patented calibration solution technique ensures thermal equilibrium.
In addition, ABB offer greater security at a lower cost by having:
A worldwide network of companies and agents to ensure backup in most countries.
Proven reliability – over 100 years of process instrumentation experience.

Associated Instrumentation Products from ABB

Full installation, commissioning and routine servicing facilities available.
Analytical applications
pH monitors and associated electrode systems.
Conductivity monitors and associated measuring cells.
Silica monitors.
Industrial applications
Recorders and recorder/controllers.
Flow applications
MagMaster flowmeters.
Differential pressure transmitters.
2
Page 3
Sodium Monitoring in Water Treatment Processes
8241 Silica
Monitor
4600 Series Conductivity Transmitters
Portable Rack
(can also be fixed)
8037 Sodium Monitor

Installation

8037 Transmitter unit
Standard solution bottle, mounted on shelf level with the top of the liquid handling (sensor) unit
AG/AI-024_4
ABB Sodium monitors are normally located inside the Water Treatment Plant on a rack – preferably in an air-conditioned room.
Samples are normally at ambient temperatures so sample cooling should
not be necessary (even the polishing plant will be below 55°C).
Fit a needle valve upstream to control the sample flow within required limits.
Conveniently site the standard solution bottles on the top of the liquid handling section of the monitor.
8037 Liquid handling (sensor) unit
Drain
Model 8037 Sodium monitor – wall-mounted
Turbine
Make-up
Water
Extraction
Demineralisation
plant
* Condensate Polishing Plant
Condenser
Pump
Sodium monitor in typical rack-mounted arrangement
Generator
Economiser
*CPP LP Heaters Deaerator HP Feed
Pump
8037 Sodium Monitor Range: 0.01ppb to 1.0ppm Normal sodium concentration = 1ppb (approx.)
HP Heaters
Simplified schematic of 'once-through' boiler system showing location on CPP
3
Page 4
Sodium Monitoring in Water Treatment Processes
AG/AI-024_4

Process Description

Basic Measurement/ Analysis Theory
All on-line sodium monitors are based on the use of a sodium ion selective electrode and a reference electrode. The measurement is very similar to that of pH, with the electrode pair also responding to hydrogen ions and changes in sample temperature.
The hydrogen ion interference is controlled by raising the pH of the sample (reducing the hydrogen ion concentration). This is achieved by adding an alkali – usually ammonia gas or a volatile amine. Temperature effects are reduced by monitoring temperature and carrying out automatic temperature compensation. The monitor is calibrated by use of solutions of known sodium ion concentration, with the electrode pair producing a millivolt output proportional to the sodium ion concentration.
Cation Exchange Bed
Cations are exchanged for hydrogen ions in this bed until all the hydrogen ions in the bed have been removed. At this stage (known as resin bed exhaustion) the levels of dissolved solids in the water will increase and the resin will need to be regenerated by passing acid (usually sulphuric or hydrochloric) to reinstate the hydrogen ions in the resin.
Mixed Bed
The mixed bed contains a mixture of both cation and anion exchange resins to further reduce the dissolved solids content, and thus produce the quality of make-up water required.

Measuring Points

Condensate Polishing Plant (CPP)
This type of plant is used mainly on once-through type boilers. It takes the condensate from the steam turbine/condenser and purifies or polishes it to reduce the concentrations of any impurities such as sodium chloride, sulphate etc., which may have entered the system via condenser tube leaks. Condensate polishing plants (CPP's – see figure on previous page) only normally remove small levels of contaminants, therefore only have a mixed bed stage.
Cation Bed Outlet
Monovalent cations such as sodium (Na cation resin exhaustion occurs. The ability of the sodium monitor to detect very low levels of sodium makes it a much more sensitive method of detecting resin exhaustion than conductivity.
Mixed Bed Outlet
Here again, sodium monitors are used to check the quality of the final water and detect exhaustion of the cation exchange resin within the mixed bed. It is essential that the sodium concentration in the final water is kept as low as possible to minimize thermal losses due to blowdown.
Condensate Polishing Plant (CPP) Outlet
As with the complete demineralisation plant, the CPP has a sodium monitor on the outlet from the mixed bed unit to detect exhaustion of the cation resin. This is particularly important on once-through boilers as any sodium in the feed water after the CPP is deposited in the boiler, causing corrosion and potentially, the premature shutdown of the system.
+
) are the first ions to breakthrough when
4
Page 5
AG/AI–024 Issue 4
ABB has Sales & Customer Support expertise in over 100 countries worldwide
www.abb.com
ABB Limited
Oldends Lane, Stonehouse Gloucestershire GL10 3TA UK Tel: +44 (0)1453 826661 Fax: +44 (0)1453 827856
ABB Inc.
125 E. County Line Road Warminster PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183
The Companys policy is one of continuous product improvement and the right is reserved to modify the
information contained herein without notice.
Printed in UK (12.03)
© ABB 2003
Loading...