3M™ Particulate Respirator,
8293, P100
Key Features
• NIOSH approved P100 rating
• Adjustable buckles
• Foam Faceseal
• Cool Flow
• Individually packaged
Material Composition
• Straps – Braided Polyisoprene &
Cotton/Polyester
• Buckles - Polypropylene
• Nose Clip – Aluminum
• Faceseal – Polyvinyl Chloride Foam
• Filter – Polypropylene
• Shell – Polyester
• Coverweb - Polypropylene
• Valve – Polypropylene & Polyisoprene
• This respirator contains no components made
from natural rubber latex
• Approximate weight of product: 0.95 oz
Country of Origin
Made in USA with Globally Source Materials.
Use For
• Use for solid particulates and liquid mists in
concentrations not exceeding 10X PEL/OEL
• Use for oil based particles from sprays that do
not also emit vapors
• Always follow
manners as indicated
™
Exhalation Valve
User Instructions
and use in
Do Not Use For
• DO NOT use for gases and vapors, asbestos,
or abrasive blasting
• DO NOT use for particulate concentrations
exceeding 10X PEL/OEL
• DO NOT use in any manner not indicated in
User Instructions
the
Approvals and Standards
• NIOSH approved P100 particulate respirator
• Meets NIOSH 42 CFR 84 P100 requirements
for a minimum 99.97% filtration efficiency
against solid and liquid aerosols, including
those that contain oil.
• NIOSH approval number: TC-84A-2561
• OSHA Assigned Protection Factor
(APF) 10
Ordering Information
Description UPC ID # Respirators/Bag Bags/Case Each/Case
Respirator
Find Quality Products Online at: sales@GlobalTestSupply.com
50051138543360 70-0707-5747-4 1 20 20
www.GlobalTestSupply.com

Acceptable with this
product?
Time Use Limitation
Replace the respirator when it becomes dirty,
damaged, or difficult to breathe through. If used in
environments containing oil aerosols, dispose of
respirator after 40 hours or 30 days of use, whichever
occurs first.
Shelf Life and Storage
• 5 years from the date of manufacture
• Store respirators in the original packaging,
away from contaminated areas, dust,
sunlight, extreme temperatures, excessive
moisture, and damaging chemicals
• Store in temperatures between -4°F
(-20°C) and +86°F (+30°C) and not
exceeding 80% RH
WARNING!
This respirator helps reduce exposures to certain
airborne contaminants. Before use, the wearer
must read and understand the
provided as a part of the product packaging.
Follow all local regulations. In the U.S., a written
respiratory protection program must be
implemented meeting all the requirements of
OSHA 1910.134, including training, fit testing and
medical evaluation. In Canada, CSA standard
Z94.4 requirements must be met and/or
requirements of the applicable jurisdiction, as
appropriate. Misuse may result in sickness or
death. For correct use, consult supervisor and the
User Instructions,
Service in USA at 1-800-243-4630 and in
Canada at 1-800-267-4414.
User Instructions
or call 3M PSD Technical
Acceptable Fit Test Protocols
Fit Test Protocol*
Saccharin ☒
Qualitative
Protocols
Smoke
Quantitative Protocols** ☒
*Refer to OSHA 1910.134
**A probed model – 8293Q (70-0707-9982-3) is