3M 70070757474 User manual

Particulate
8293
3M™ Particulate Respirator, 8293, P100
Key Features
NIOSH approved P100 rating
Foam Faceseal
Cool Flow
Individually packaged
Material Composition
Straps – Braided Polyisoprene &
Cotton/Polyester
Buckles - Polypropylene
Nose Clip – Aluminum
Faceseal – Polyvinyl Chloride Foam
Filter – Polypropylene
Shell – Polyester
Coverweb - Polypropylene
Valve – Polypropylene & Polyisoprene
This respirator contains no components made
from natural rubber latex
Approximate weight of product: 0.95 oz
Country of Origin
Made in USA with Globally Source Materials.
Use For
Use for solid particulates and liquid mists in
concentrations not exceeding 10X PEL/OEL
Use for oil based particles from sprays that do
not also emit vapors
Always follow
manners as indicated
Exhalation Valve
User Instructions
and use in
Do Not Use For
DO NOT use for gases and vapors, asbestos,
or abrasive blasting
DO NOT use for particulate concentrations
exceeding 10X PEL/OEL
DO NOT use in any manner not indicated in
User Instructions
the
Approvals and Standards
NIOSH approved P100 particulate respirator
Meets NIOSH 42 CFR 84 P100 requirements
for a minimum 99.97% filtration efficiency against solid and liquid aerosols, including those that contain oil.
NIOSH approval number: TC-84A-2561
OSHA Assigned Protection Factor
(APF) 10
Ordering Information
Description UPC ID # Respirators/Bag Bags/Case Each/Case
Respirator
Find Quality Products Online at: sales@GlobalTestSupply.com
50051138543360 70-0707-5747-4 1 20 20
www.GlobalTestSupply.com
Acceptable with this
product?
BitrexTM
Irritant
Isoamyl Acetate
Time Use Limitation
Replace the respirator when it becomes dirty, damaged, or difficult to breathe through. If used in environments containing oil aerosols, dispose of respirator after 40 hours or 30 days of use, whichever occurs first.
Shelf Life and Storage
5 years from the date of manufacture
Store respirators in the original packaging,
away from contaminated areas, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals
Store in temperatures between -4°F
(-20°C) and +86°F (+30°C) and not exceeding 80% RH
WARNING!
This respirator helps reduce exposures to certain airborne contaminants. Before use, the wearer must read and understand the provided as a part of the product packaging. Follow all local regulations. In the U.S., a written respiratory protection program must be implemented meeting all the requirements of OSHA 1910.134, including training, fit testing and medical evaluation. In Canada, CSA standard Z94.4 requirements must be met and/or requirements of the applicable jurisdiction, as appropriate. Misuse may result in sickness or death. For correct use, consult supervisor and the
User Instructions,
Service in USA at 1-800-243-4630 and in Canada at 1-800-267-4414.
User Instructions
or call 3M PSD Technical
Acceptable Fit Test Protocols
Fit Test Protocol*
Saccharin
Qualitative
Protocols
Smoke
Quantitative Protocols**
*Refer to OSHA 1910.134
**A probed model – 8293Q (70-0707-9982-3) is available for quantitative fit testing
☒ ☒