On replacement installations, mount the new thermostat in place of the
On replacement installations, mount the new thermostat in place of the
old one if possible.
old one if possible.
On new Installations, follow the guidelines listed below.
On new Installations, follow the guidelines listed below.
Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the
Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the
floor, and in a room that is used often.
floor, and in a room that is used often.
Do not install it where there are unusual heating conditions, such as: in
Do not install it where there are unusual heating conditions, such as: in
direct sunlight; near a lamp, radio, television, radiator register, or
direct sunlight; near a lamp, radio, television, radiator register, or
fireplace; near hot water pipes in a wall; near a stove on the other side
fireplace; near hot water pipes in a wall; near a stove on the other side
of a wall.
of a wall.
Good
Good
5ft.
5ft.
(1.5m)
(1.5m)
turn electricity back on until work is completed.
turn electricity back on until work is completed.
Do not short (jumper) across electric terminals at
Do not short (jumper) across electric terminals at
control on furnace or air conditioner to test the system.
control on furnace or air conditioner to test the system.
This will damage the thermostat and void your warranty.
This will damage the thermostat and void your warranty.
All wiring must conform to local codes and ordinances.
All wiring must conform to local codes and ordinances.
This thermostat is designed for use with 24 volt AC and
This thermostat is designed for use with 24 volt AC and
millivolt systems. The thermostat should be limited to a
millivolt systems. The thermostat should be limited to a
Operation 8082
Operation 8082
MENU
RESET
C A U T I O N
C A U T I O N
Your thermostat is a precise instrument.
Your thermostat is a precise instrument.
Please handle it with care.
Please handle it with care.
Turn off electricity to the appliance before installing or
Turn off electricity to the appliance before installing or
servicing thermostat or any part of the system. Do not
servicing thermostat or any part of the system. Do not
To avoid electrical shock and to prevent damage to the furnace, air conditioner,
To avoid electrical shock and to prevent damage to the furnace, air conditioner,
and thermostat, disconnect the power supply before beginning work.
and thermostat, disconnect the power supply before beginning work.
Caution
Caution
This can be done at the circuit breaker, or at the appliance.
This can be done at the circuit breaker, or at the appliance.
Tools
Tools
1 Location
1 Location
On replacement installations, mount the new
On replacement installations, mount the new
PROGRAM
thermostat in place of the old one if possible.
thermostat in place of the old one if possible.
On new Installations, follow the guidelines listed
On new Installations, follow the guidelines listed
below.
below.
Locate the thermostat on an inside wall, about 5 ft.
Locate the thermostat on an inside wall, about 5 ft.
(1.5m) above the floor, and in a room that is used
(1.5m) above the floor, and in a room that is used
often.
often.
Do not install it where there are unusual heating
Do not install it where there are unusual heating
You will
You will need #1 Phillips screwdriver
(small) and
Reset
button
TEMP
Up/Down
Dial
Target
Temp
Time
Front Cover
1006-017
AAA
PROGRAM HOLDCOPY REVIEW FILTER
EPA
TIME SLOT
TIME SET
8
Covers removed
PROG2
SET CLOCK
7
R C
G A
3 4 5 6
Operation 3M-25
TARGET TEMP
HEAT
SET CLOCK
PROGRAM
EPA
HEAT
PROG2
TIME SLOT
COPY
Visit our website www.radiothermostat.com/filtrete
Set Clock
Set day of the week -
• Press SET CLOCK once
TARGET TEMP
SET CLOCK
PROG2
to set the day of the week.
The day of the week display
flashes. (Initially SU for Sunday)
• Press <TIME or TIME>
TIMETIME
to select the day.
HEAT
AAA
TIME SLOT
EPA
PROGRAM HOLDCOPY REVIEW FILTER
AAA
Set time of day -
• Press SET CLOCK again to set the time. The time display will flash.
• Press <TIME or TIME> to set the time. Press and hold to set the time
in the fast mode.
• Press HOME to store your settings.
Energy Saving Program
This Thermostat comes preprogrammed
TIMETIME
HEAT
All Days 70oF 62oF 70oF
COOL
All Days 78oF 85oF 78oF
MORN
6:00am
MORN
6:00am
DAY
8:00am
DAY
8:00am
EVEN
6:00pm
EVEN
6:00pm
AAA
C B O W2W Y Y2R H
Customer Support: 888-607-5824 or
TARGET TEMP
1
2
with an energy saving program. This program is recommended for energy
efficiency. We strongly recommend that you use this program for one week,
and see if it works for you. If it does not fit your needs you can always input a
custom program.
• To Run the energy saving program, select HEAT or COOL
with the mode switch. The unit is now running the energy
saving
program. To return to the energy saving program
press
EPA.
• One of the TIME SLOT icons
MORN, DAY, EVEN, NITE
comes
target
temp
TARGET TEMP
on, this indicates the TIME SLOT active in the energy
program. For program details refer to the energy
saving
saving program chart above.
PG
3
time
day
Fan
Switch
Statement of use:
The 3M-25 can be
used with - millivolt,
24V single and
2-stage
conventional
systems,
gas/oil/electric heat,
1-stage heat
pumps, 2 -stage
heat pumps, zoned
hot water (2 or 3
wire), zoned forced
air, single and
2-stage cooling, and
hybrid systems.
ENGLISH
Control Panel
Heat/Cool
Mode Switch
TIME SET
TER
FIL
REVIEW
HOLD
Battery
Compartment
TIME SET
time
slot
mode
PG
NIGHT
10:00pm
NIGHT
10:00pm
temp
HEAT
2
FOLD
LINE
Program
NOTE: 60 Second Rule-During programming, if a button is not
pushed within 60 seconds, the unit will go out of the set mode.
Everything you have input in this programming will automatically be saved.
• Select HEAT with the HEAT/Cool MODE switch.
• To select the DAY you want to program: Press PROGRAM to enter
programming mode. The PROGRAM icon will come on. The day icon will show
SU (Sunday). Press
day again to advance the day selection.
DAY
• Select the TIME SLOT you want to program: To change the TIME SLOT
(MORN, DAY, EVEN, NITE) press the
NEXT button. The display will cycle
NEXT
through the time periods in sequence. Select MORN.
• Select the desired temperature for that TIME SLOT : To change the
temperature for that TIME SLOT turn the TEMP +/- dial.
PG
• Select the time of day you want that TIME SLOT to represent:
To set the time when
MORN will begin , press the <TIME or TIME> buttons
TIME TIME
to move the set point forward or backward in time.
•
Select the next TIME SLOT and program temp and time:
NEXT>
Press
the display will show
NEXT
Select the remaining TIME SLOT's,
DAY
. Repeat setting temp and time.
EVEN
and
NITE.
Program their temp and
time info. Repeat the above procedures for each day of the week.
DAY
DAY>
Push
button to cycle through the days.
To COPY the program of the current day to another day, press COPY
program once. COPY will display on the LCD. The day icon for the source
day will go solid and the day icon for the destination day will flash. Use day
button to select the destination day. Press COPY again to confirm the copy.
If you decide you don't want to copy, press HOME to exit.
PG
4
5
Program cont.
PROG 2: An alternative program can be used for holidays, shift work, etc.
Access by pushing the PROG 2 button. PROG 2 will then be active until you
shut it off by touching the PROG 2 button again. The main program will then
DAY
DAY
again be active. To change PROG 2 press
until PROG 2 is displayed
and repeat the programming procedure.
•
When finished with your custom program, either wait 60 sec or press HOME
to save and run your program.
To program for COOL, select COOL with the Heat/Cool MODE switch and
repeat the above procedure.
To REVIEW the program you have entered:Press PROGRAM once to enter
programming mode.Then press FILTER/REVIEW once.
PG
6
The display will cycle through the programmed times and temps, showing
each program for 12 seconds. Starting from Sunday;
Saturday;
NITE. The programmed temperature is shown on the left of the
MORN and ending on
LCD, the programmed time, day and time slot are shown on the right and the
right top of the LCD respectfully.
•
Press HOME to leave program REVIEW mode and run the program.
Special Features - Swing
SWING setting determines the temperature
difference from ON to OFF that the 3M-25 will command the HVAC system to run.
• With the MODE switch in HEAT or COOL, press the
•
The
SWING icon is displayed. The current setting of temp swing is shown on the
display (default at .5
To change the swing, press the
o
F).
TIME TIME
or
cycle more at the lower numbers as it tries to keep your set point constant.
To complete the swing setting, push the
HOME
button.
button.
TIME
buttons. The furnace will
PG
7
Spec. Featr. cont.
Manual
• With the MODE switch in HEAT or COOL,
temp control dial
to temporarily change the control
turn
TEMP control
dial
warmer
temperature by 1 degree per step.
NOTE: to avoid accidental setting changes intial
cooler
touch is delayed .5sec. After that all functions are
instant.
• The OVERRIDE icon flashes to shows the displayed temperature may be
different from the programmed setting.
• The OVERRIDE is canceled at the start of the next time period,
or when the MODE switch is moved, or if
TEMP HOLD
is pressed twice.
Temp HOLD
To change and hold the temperature until you return.
•
Open the door and push the
HOLD
button. The HOLD icon comes on.
Turn the temp control dial to set the hold temperature.
•
HOLD is canceled if the MODE switch is moved, or press
HOLD
again.
Lock
Allows you to lock the 3M-25 (to prevent any changes in custom settings)
•
To enable or disable the program lock, press the following buttons one at
a time,in this sequence.
<tim then
TIME
FILTER
, then
SET CLOCK
, and last
HOME
.
The LOCK icon (a key) appears when the system is locked.
•
Repeat to unlock
PG
TARGET TEMP
PG
8
9
Filter
The life of a HVAC filter varies depending on many factors, furnace run time,
and this will vary from the filter life noted on the filter media. The 3M-25 has a
feature that keeps track of actual furnace run time and reminds you to
periodically replace your system's air filter.
•
Press the FILTER button once to review the current filter record.
The
FILTER
and
WKS
icons come on with filter run-weeks being displayed.
•
Press
TIME
to clear the record. Press again to recover old run-time.
• To SET or see the LIMIT FILTER setting, press and hold the FILTER button
for two seconds. The default filter limit is set to 0 weeks and the max setting is
99 weeks. Use the buttons to set the filter limit. The LIMIT
TIME
TIME
FILTER must be set to get a FILTER warning on the HOME screen when the
filter needs service.
To leave the filter display, press
HOME
or wait 60 seconds.
Low Battery
•
When the batteries are low, the battery icon will come on and flash.
The two AAA Batteries in the unit need to be replaced. In some
installations your heater system will stop functioning when the thermosat
loses power. Replace batteries as soon as you see this warning. The
thermostat programs will remain for 30 seconds while the batteries are
removed and replaced.
•
Do not take longer than 30 sec to change the batteries in your unit
or you will lose all custom settings and all programming. Only the Energy
Saving program will remain. Once the batteries are replaced, the system will
return to normal in 2 seconds.
PG
PG
10
11
C or F display HEAT PUMP AUX only
Celsius / Fahrenheit selection. The C/F jumper is on the top left of the 3M-25:
With the jumper OFF 3M-25 displays Fahrenheit.
When changed, the thermostat must be reset to activate the change. When
If you have a heat pump with auxiliary heat, and the heat pump is not
working properly, your thermostat will still keep your room temperature
within about 2F of the target temperature.
resetting, all custom settings and programming will be erased and only the
energy saving program will remain.
12/24 hour
The thermostat can display time in 12 or 24 hour
12/24hr
jumper
o
C -oF jumper
formats. The 12/24 jumper is on the top of the
3M-25. With the jumper OFF the 6025 displays
12 hour time, 24 hour time with the jumper ON.
When changed, the thermostat must be
PG
Calibration
NOTE: Your thermostat comes from the factory calibrated to + or - 1oF actual
temperature. It is an accurate instrument. If you want your thermostat to
display the same temperature as another thermometer in your home, you can
adjust its calibration.
To change the calibration:
12
• To select Auxiliary ONLY heat by temporally moving the HEAT PUMP
[Jumper 5] jumper to the AUX ONLY position [Jumper 6]. This will keep your
room temperature within the swing setting of the target temperature.
•Be sure to restore it to PUMP when the pump
is again operational as aux heat is more
expensive than pump heat.
3M-25 Features
This thermostat can be used with all millivolt and 24VAC heating and cooling
systems. It cannot be used with line voltage systems. This thermostat is digital
and your desired heat or cool temperatures can easily be set on the large
screen with the +/- dial. A minimum 4 minute off time protects heating and
cooling systems from damage.
Mode switch of the unit must be in the HEAT or COOL position.
Press the <Time button.
Turn the Temp +/- dial to adjust the offset temperature reading.
TIME
TARGET TEMP
Press HOME to save the new setting.
HEAT
PG
13
HEAT PUMP
3 4 5 6
G A
7
8
This thermostat uses a new technique
called sequential staging for more
comfort with faster reaction to requested
HEAT
OFF
COOL
temperature changes when controlling 2
FAN
ON
stage systems.
AUTO
AUX only
PG
14
PG